Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 30(7): 3692-3701, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32166492

RESUMEN

OBJECTIVE: To determine the potential impact of on-site CT-derived fractional flow reserve (CT-FFR) on the diagnostic efficiency and effectiveness of coronary CT angiography (CCTA) in patients with obstructive coronary artery disease (CAD) on CCTA. METHODS: This observational cohort study included patients with suspected CAD who had been randomized to cardiac CT in the CRESCENT I and II trials. On-site CT-FFR was blindly performed in all patients with at least one ≥ 50% stenosis on CCTA and no exclusion criteria for CT-FFR. We retrospectively assessed the effect of adding CT-FFR to the CT protocol in patients with a stenosis ≥ 50% on CCTA in terms of diagnostic effectiveness, i.e., the number of additional tests required to determine the final diagnosis, reclassification of the initial management strategy, and invasive coronary angiography (ICA) efficiency, i.e., ICA rate without ≥ 50% CAD. RESULTS: Fifty-three patients out of the 372 patients (14%) had at least one ≥ 50% stenosis on CCTA of whom 42/53 patients (79%) had no exclusion criteria for CT-FFR. CT-FFR showed a hemodynamically significant stenosis (≤ 0.80) in 27/53 patients (51%). The availability of CT-FFR would have reduced the number of patients requiring additional testing by 57%-points compared with CCTA alone (37/53 vs. 7/53, p < 0.001). The initial management strategy would have changed for 30 patients (57%, p < 0.001). Reserving ICA for patients with a CT-FFR ≤ 0.80 would have reduced the number of ICA following CCTA by 13%-points (p = 0.016). CONCLUSION: Implementation of on-site CT-FFR may change management and improve diagnostic efficiency and effectiveness in patients with obstructive CAD on CCTA. KEY POINTS: • The availability of on-site CT-FFR in the diagnostic evaluation of patients with obstructive CAD on CCTA would have significantly reduced the number of patients requiring additional testing compared with CCTA alone. • The implementation of on-site CT-FFR would have changed the initial management strategy significantly in the patients with obstructive CAD on CCTA. • Restricting ICA to patients with a positive CT-FFR would have significantly reduced the ICA rate in patients with obstructive CAD on CCTA.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Aprendizaje Automático , Anciano , Cateterismo Cardíaco , Estudios de Cohortes , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Manejo de la Enfermedad , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
2.
Eur Radiol ; 29(11): 6109-6118, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31016447

RESUMEN

OBJECTIVE: To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA). METHODS: One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups. RESULTS: Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001). CONCLUSION: Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media. KEY POINTS: • The contrast enhancement in coronary CT angiography is independent of the iodine concentration when contrast media are injected at body temperature (37 °C) with the same iodine delivery rate. • Iodine concentration does not influence the change in heart rate when contrast media are injected at identical iodine delivery rates. • For a fixed iodine delivery rate and contrast temperature, the viscosity of the contrast medium affects the injection pressure.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/farmacocinética , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Yodo/metabolismo , Yohexol/farmacocinética , Medios de Contraste/administración & dosificación , Enfermedad de la Arteria Coronaria/metabolismo , Femenino , Humanos , Inyecciones Intravenosas , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Yopamidol/administración & dosificación , Yopamidol/análogos & derivados , Yopamidol/farmacocinética , Masculino , Persona de Mediana Edad
3.
Radiology ; 286(1): 71-80, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28809582

RESUMEN

Purpose To show that equal coronary lumen opacification can be achieved with iso- and low-osmolar contrast media when it is injected at the same iodine delivery rate with contemporary cardiac computed tomographic (CT) protocols and to investigate the cardiovascular effect of iso-osmolar contrast media and the image quality achieved. Materials and Methods Institutional review board approval and written informed consent were obtained for the Effect of Iso-osmolar Contrast Medium on Coronary Opacification and Heart Rhythm in Coronary CT Angiography, or IsoCOR, trial. Between November 2015 and August 2016, 306 patients (167 [55%] women) at least 18 years old (weight range, 50-125 kg), were prospectively randomized to receive iso-osmolar iodixanol 270 or low-osmolar iopromide 300 contrast media. All coronary segments were assessed for intraluminal opacification and image quality and were compared by using the Student t test. Heart rate, arrhythmia, patient discomfort, and adverse events also were monitored. Results Mean measured coronary attenuation values ± standard deviation were comparable between the iodixanol 270 and iopromide 300 contrast media groups (469 HU ± 167 vs 447 HU ± 166, respectively [P = .241]; 95% confidence interval: -15.1, 60.0), including those from subanalyses. Adjusted for the lower iodine concentration, the mean iodixanol 270 bolus was larger compared with that of iopromide 300 (76.8 mL ± 11.6 vs 69.7 mL ± 10.8, respectively; P < .001). The higher injection rate was associated with higher pressure (777 kPa ± 308 vs 630 kPa ± 252, respectively; P < .001). Although in the iodixanol 270 group patients experienced less heat discomfort (72% vs 86%, respectively; P < .001), no differences in heart rate or rhythm were observed. Conclusion If injected at comparable iodine delivery rates, the iso-osmolar contrast medium iodixanol 270 is not inferior to low-osmolar contrast medium iopromide 300 for assessment of coronary opacification. Iodixanol 270 was associated with less heat discomfort, but did not affect heart rate differently compared with iopromide 300. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste/uso terapéutico , Angiografía Coronaria , Yohexol/análogos & derivados , Ácidos Triyodobenzoicos/uso terapéutico , Adulto , Presión Sanguínea/efectos de los fármacos , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Medios de Contraste/efectos adversos , Angiografía Coronaria/métodos , Angiografía Coronaria/estadística & datos numéricos , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Yohexol/efectos adversos , Yohexol/uso terapéutico , Masculino , Persona de Mediana Edad , Factores de Riesgo , Ácidos Triyodobenzoicos/efectos adversos
4.
Eur Radiol ; 28(5): 2169-2175, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29247351

RESUMEN

OBJECTIVE: To assess the image quality of coronary CT angiography (CCTA) for suspected acute coronary syndrome (ACS) outside office hours. METHODS: Patients with symptoms suggestive of an ACS underwent CCTA at the emergency department 24 hours, 7 days a week. A total of 118 patients, of whom 89 (75 %) presented during office hours (weekdays between 07:00 and 17:00) and 29 (25 %) outside office hours (weekdays between 17:00 and 07:00, weekends and holidays) underwent CCTA. Image quality was evaluated per coronary segment by two experienced readers and graded on an ordinal scale ranging from 1 to 3. RESULTS: There were no significant differences in acquisition parameters, beta-blocker administration or heart rate between patients presenting during office hours and outside office hours. The median quality score per patient was 30.5 [interquartile range 26.0-33.5] for patients presenting during office hours in comparison to 27.5 [19.75-32.0] for patients presenting outside office hours (p=0.043). The number of non-evaluable segments was lower for patients presenting during office hours (0 [0-1.0] vs. 1.0 [0-4.0], p=0.009). CONCLUSION: Image quality of CCTA outside office hours in the diagnosis of suspected ACS is diminished. KEY POINTS: • Quality scores were higher for coronary-CTA during office hours. • There were no differences in acquisition parameters. • There was a non-significant trend towards higher heart rates outside office hours. • Coronary-CTA on the ED requires state-of-the-art scanner technology and sufficiently trained staff. • Coronary-CTA on the ED needs preparation time and optimisation of the procedure.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Unidades de Cuidados Coronarios , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
5.
Eur Radiol ; 27(6): 2309-2316, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27704198

RESUMEN

OBJECTIVES: To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). METHODS: Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. RESULTS: Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. CONCLUSIONS: Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. KEY POINTS: • The transmural perfusion ratio from dynamic CT-MPI predicts functional obstructive coronary artery disease • Performance of the transmural perfusion ratio is inferior to quantified myocardial blood flow • The incremental value of the transmural perfusion ratio is limited.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Hemodinámica/fisiología , Imagen de Perfusión Miocárdica/métodos , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos
6.
Eur Radiol ; 27(4): 1416-1423, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27541354

RESUMEN

OBJECTIVES: The aim of this study is to assess the effect of blood pressure (BP) on coronary computed tomography angiography (CTA) derived computational fractional flow reserve (CTA-FFR). MATERIALS AND METHODS: Twenty-one patients who underwent coronary CTA and invasive FFR were retrospectively identified. Ischemia was defined as invasive FFR ≤0.80. Using a work-in-progress computational fluid dynamics algorithm, CTA-FFR was computed with BP measured before CTA, and simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg respectively. Correlation between CTA-FFR and invasive FFR was assessed using Pearson test. The repeated measuring test was used for multiple comparisons of CTA-FFR values by simulated BP inputs. RESULTS: Twenty-nine vessels (14 with invasive FFR ≤0.80) were assessed. The average CTA-FFR for measured BP (134 ± 20/73 ± 12 mmHg) was 0.77 ± 0.12. Correlation between CTA-FFR by measured BP and invasive FFR was good (r = 0.735, P < 0.001). For simulated BPs of 60/50, 90/60, 110/70, 130/80, 150/90, and 180/100 mmHg, the CTA-FFR increased: 0.69 ± 0.13, 0.73 ± 0.12, 0.75 ± 0.12, 0.77 ± 0.11, 0.79 ± 0.11, and 0.81 ± 0.10 respectively (P < 0.05). CONCLUSION: Measurement of the BP just before CTA is preferred for accurate CTA-FFR simulation. BP variations in the common range slightly affect CTA-FFR. However, inaccurate BP assumptions differing from the patient-specific BP could cause misinterpretation of borderline significant lesions. KEY POINTS: • The blood pressure (BP) affects the CTA-FFR computation. • Measured BP before CT examination is preferable for accurate CTA-FFR simulation. • Inaccurate BP assumptions can cause misinterpretation of borderline significant lesions.


Asunto(s)
Presión Sanguínea/fisiología , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Anciano , Algoritmos , Femenino , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
7.
Eur Heart J ; 37(15): 1232-43, 2016 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-26746631

RESUMEN

AIMS: To compare the effectiveness and safety of a cardiac computed tomography (CT) algorithm with functional testing in patients with symptoms suggestive of coronary artery disease (CAD). METHODS AND RESULTS: Between April 2011 and July 2013, 350 patients with stable angina, referred to the outpatient clinic of four Dutch hospitals, were prospectively randomized between cardiac CT and functional testing (2 : 1 ratio). The tiered cardiac CT protocol included a calcium scan followed by CT angiography if the Agatston calcium score was between 1 and 400. Patients with test-specific contraindications were not excluded from study participation. By 1 year, fewer patients randomized to cardiac CT reported anginal complaints (P = 0.012). The cumulative radiation dose was slightly higher in the CT group (6.6 ± 8.7 vs. 6.1 ± 9.3 mSv; P < 0.0001). After 1.2 years, event-free survival was 96.7% for patients randomized to CT and 89.8% for patients randomized to functional testing (P = 0.011). After CT, the final diagnosis was established sooner (P < 0.0001), and additional downstream testing was required less frequently (25 vs. 53%, P < 0.0001), resulting in lower cumulative diagnostic costs (€369 vs. €440; P < 0.0001). CONCLUSION: For patients with suspected stable CAD, a tiered cardiac CT protocol offers an effective and safe alternative to functional testing. Incorporating the calcium scan into the diagnostic workup was safe and lowered diagnostic expenses and radiation exposure.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Electrocardiografía , Prueba de Esfuerzo/métodos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/estadística & datos numéricos , Dosis de Radiación , Factores de Riesgo , Encuestas y Cuestionarios , Resultado del Tratamiento , Calcificación Vascular/fisiopatología , Calcificación Vascular/terapia
8.
Radiology ; 274(3): 674-83, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25322342

RESUMEN

PURPOSE: To validate an on-site algorithm for computation of fractional flow reserve (FFR) from coronary computed tomographic (CT) angiography data against invasively measured FFR and to test its diagnostic performance as compared with that of coronary CT angiography. MATERIALS AND METHODS: The institutional review board provided a waiver for this retrospective study. From coronary CT angiography data in 106 patients, FFR was computed at a local workstation by using a computational fluid dynamics algorithm. Invasive FFR measurement was performed in 189 vessels (80 of which had an FFR ≤ 0.80); these measurements were regarded as the reference standard. The diagnostic characteristics of coronary CT angiography-derived computational FFR, coronary CT angiography, and quantitative coronary angiography were evaluated against those of invasively measured FFR by using C statistics. Sensitivity and specificity were compared by using a two-sided McNemar test. RESULTS: For computational FFR, sensitivity was 87.5% (95% confidence interval [CI]: 78.2%, 93.8%), specificity was 65.1% (95% CI: 55.4%, 74.0%), and accuracy was 74.6% (95% CI: 68.4%, 80.8%), as compared with the finding of lumen stenosis of 50% or greater at coronary CT angiography, for which sensitivity was 81.3% (95% CI: 71.0%, 89.1%), specificity was 37.6% (95% CI: 28.5%, 47.4%), and accuracy was 56.1% (95% CI: 49.0%, 63.2%). C statistics revealed a larger area under the receiver operating characteristic curve (AUC) for computational FFR (AUC, 0.83) than for coronary CT angiography (AUC, 0.64). For vessels with intermediate (25%-69%) stenosis, the sensitivity of computational FFR was 87.3% (95% CI: 76.5%, 94.3%) and the specificity was 59.3% (95% CI: 47.8%, 70.1%). CONCLUSION: With use of a reduced-order algorithm, computation of the FFR from coronary CT angiography data can be performed locally, at a regular workstation. The diagnostic accuracy of coronary CT angiography-derived computational FFR for the detection of functionally important coronary artery disease (CAD) was good and was incremental to that of coronary CT angiography within a population with a high prevalence of CAD.


Asunto(s)
Algoritmos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
9.
Circ Cardiovasc Imaging ; 11(6): e007217, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29914866

RESUMEN

BACKGROUND: Coronary computed tomographic angiography (CTA) is a reliable modality to detect coronary artery disease. However, CTA generally overestimates stenosis severity compared with invasive angiography, and angiographic stenosis does not necessarily imply hemodynamic relevance when fractional flow reserve (FFR) is used as reference. CTA-based FFR (CT-FFR), using computational fluid dynamics (CFD), improves the correlation with invasive FFR results but is computationally demanding. More recently, a new machine-learning (ML) CT-FFR algorithm has been developed based on a deep learning model, which can be performed on a regular workstation. In this large multicenter cohort, the diagnostic performance ML-based CT-FFR was compared with CTA and CFD-based CT-FFR for detection of functionally obstructive coronary artery disease. METHODS AND RESULTS: At 5 centers in Europe, Asia, and the United States, 351 patients, including 525 vessels with invasive FFR comparison, were included. ML-based and CFD-based CT-FFR were performed on the CTA data, and diagnostic performance was evaluated using invasive FFR as reference. Correlation between ML-based and CFD-based CT-FFR was excellent (R=0.997). ML-based (area under curve, 0.84) and CFD-based CT-FFR (0.84) outperformed visual CTA (0.69; P<0.0001). On a per-vessel basis, diagnostic accuracy improved from 58% (95% confidence interval, 54%-63%) by CTA to 78% (75%-82%) by ML-based CT-FFR. The per-patient accuracy improved from 71% (66%-76%) by CTA to 85% (81%-89%) by adding ML-based CT-FFR as 62 of 85 (73%) false-positive CTA results could be correctly reclassified by adding ML-based CT-FFR. CONCLUSIONS: On-site CT-FFR based on ML improves the performance of CTA by correctly reclassifying hemodynamically nonsignificant stenosis and performs equally well as CFD-based CT-FFR.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Aprendizaje Profundo , Reserva del Flujo Fraccional Miocárdico , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Anciano , Asia , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estados Unidos
10.
JACC Cardiovasc Imaging ; 11(11): 1625-1636, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29248657

RESUMEN

OBJECTIVES: This study sought to assess the effectiveness, efficiency, and safety of a tiered, comprehensive cardiac computed tomography (CT) protocol in comparison with functional testing. BACKGROUND: Although CT angiography accurately rules out coronary artery disease (CAD), incorporation of CT myocardial perfusion imaging as part of a tiered diagnostic approach could improve the clinical value and efficiency of cardiac CT in the diagnostic work-up of patients with angina pectoris. METHODS: Between July 2013 and November 2015, 268 patients (mean age 58 years; 49% female) with stable angina (mean pre-test probability 54%) were prospectively randomized between cardiac CT and standard guideline-directed functional testing (95% exercise electrocardiography). The tiered cardiac CT protocol included a calcium scan, followed by CT angiography if calcium was detected. Patients with ≥50% stenosis on CT angiography underwent CT myocardial perfusion imaging. RESULTS: By 6 months, the primary endpoint, the rate of invasive coronary angiograms without a European Society of Cardiology class I indication for revascularization, was lower in the CT group than in the functional testing group (2 of 130 [1.5%] vs. 10 of 138 [7.2%]; p = 0.035), whereas the proportion of invasive angiograms with a revascularization indication was higher (88% vs. 50%; p = 0.017). The median duration until the final diagnosis was 0 (0 of 0) days in the CT group and 0 (0 of 17) in the functional testing group (p < 0.001). Overall, 13% of patients randomized to CT required further testing, compared with 37% in the functional testing group (p < 0.001). The adverse event rate was similar (3% vs. 3%; p = 1.000), although the median cumulative radiation dose was higher for the CT group (3.1 mSv [interquartile range: 1.6 to 7.8] vs. 0 mSv [interquartile range: 0.0 to 7.1]; p < 0.001). CONCLUSIONS: In patients with suspected stable CAD, a tiered cardiac CT protocol with dynamic perfusion imaging offers a fast and efficient alternative to functional testing. (Comprehensive Cardiac CT Versus Exercise Testing in Suspected Coronary Artery Disease 2 [CRESCENT2]; NCT02291484).


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada por Rayos X , Anciano , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Vasos Coronarios/fisiopatología , Electrocardiografía , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Países Bajos , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Índice de Severidad de la Enfermedad
11.
Clin Case Rep ; 5(8): 1252-1254, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28781835

RESUMEN

ST-T segment depression during right-sided endovascular catheter ablation is not only caused by obstructive coronary artery disease or (induced) tachycardia. Clinicians should also consider coronary artery spasms evoked by manipulation of nearby catheters, especially in patients with abnormal coronary artery anatomy.

12.
Circ Cardiovasc Imaging ; 10(2)2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28174196

RESUMEN

BACKGROUND: Cardiac computed tomography (CT) represents an alternative diagnostic strategy for women with suspected coronary artery disease, with potential benefits in terms of effectiveness and cost-efficiency. METHODS AND RESULTS: The CRESCENT trial (Calcium Imaging and Selective CT Angiography in Comparison to Functional Testing for Suspected Coronary Artery Disease) prospectively randomized 350 patients with stable angina (55% women; aged 55±10 years), mostly with an intermediate coronary artery disease probability, between cardiac CT and functional testing. The tiered cardiac CT protocol included a calcium scan followed by CT angiography if the Agatston calcium score was between 1 and 400. Patients with test-specific contraindications were not excluded from study participation. Sex differences were studied as a prespecified subanalysis. Enrolled women presented more frequently with atypical chest pain and had a lower pretest probability of coronary artery disease compared with men. Independently of these differences, cardiac CT led in both sexes to a fast final diagnosis when compared with functional testing, although the effect was larger in women (P interaction=0.01). The reduced need for further testing after CT, compared with functional testing, was most evident in women (P interaction=0.009). However, no sex interaction was observed with respect to changes in angina and quality of life, cumulative diagnostic costs, and applied radiation dose (all P interactions≥0.097). CONCLUSIONS: Cardiac CT is more efficient in women than in men in terms of time to reach the final diagnosis and downstream testing. However, overall clinical outcome showed no significant difference between women and men after 1 year. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01393028.


Asunto(s)
Angina Estable/etiología , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Disparidades en Atención de Salud , Calcificación Vascular/diagnóstico por imagen , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Supervivencia sin Enfermedad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Países Bajos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Factores Sexuales , Factores de Tiempo , Calcificación Vascular/complicaciones
13.
JACC Cardiovasc Imaging ; 10(7): 760-770, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28109933

RESUMEN

OBJECTIVES: The aim of this study was to investigate the individual and combined accuracy of dynamic computed tomography (CT) myocardial perfusion imaging (MPI) and computed tomography angiography (CTA) fractional flow reserve (FFR) for the identification of functionally relevant coronary artery disease (CAD). BACKGROUND: Coronary CTA has become an established diagnostic test for ruling out CAD, but it does not allow interpretation of the hemodynamic severity of stenotic lesions. Two recently introduced functional CT techniques are dynamic MPI and CTA FFR using computational fluid dynamics. METHODS: From 2 institutions, 74 patients (n = 62 men, mean age 61 years) planned for invasive angiography with invasive FFR measurement in 142 vessels underwent CTA imaging and dynamic CT MPI during adenosine vasodilation. A patient-specific myocardial blood flow index was calculated, normalized to remote myocardial global left ventricular blood flow. CTA FFR was computed using an on-site, clinician-operated application. Using binary regression, a single functional CT variable was created combining both CT MPI and CTA FFR. Finally, stepwise diagnostic work-up of CTA FFR with selective use of CT MPI was simulated. The diagnostic performance of CT MPI, CTA FFR, and CT MPI integrated with CTA FFR was evaluated using C statistics with invasive FFR, with a threshold of 0.80 as a reference. RESULTS: Sensitivity, specificity, and accuracy were 73% (95% confidence interval [CI]: 61% to 86%), 68% (95% CI: 56% to 80%), and 70% (95% CI: 62% to 79%) for CT MPI and 82% (95% CI: 72% to 92%), 60% (95% CI: 48% to 72%), and 70% (63% to 80%) for CTA FFR. For CT MPI integrated with CTA FFR, diagnostic accuracy was 79% (95% CI: 71% to 87%), with improvement of the area under the curve from 0.78 to 0.85 (p < 0.05). Accuracy of the stepwise approach was 77%. CONCLUSIONS: CT MPI and CTA FFR both identify functionally significant CAD, with comparable accuracy. Diagnostic performance can be improved by combining the techniques. A stepwise approach, reserving CT MPI for intermediate CTA FFR results, also improves diagnostic performance while omitting nearly one-half of the population from CT MPI examinations.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica/métodos , Adenosina/administración & dosificación , Anciano , Área Bajo la Curva , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Humanos , Londres , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Países Bajos , Valor Predictivo de las Pruebas , Curva ROC , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Vasodilatadores/administración & dosificación
14.
J Clin Imaging Sci ; 6: 44, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27833784

RESUMEN

PURPOSE: This study aims to compare image quality, radiation dose, and the influence of the heart rate on image quality of high-pitch spiral coronary computed tomography angiography (CCTA) using 128-slice (second generation) dual-source CT (DSCT) and a 192-slice DSCT (third generation) scanner. MATERIALS AND METHODS: Two consecutive cohorts of fifty patients underwent CCTA by high-pitch spiral scan mode using 128 or 192-slice DSCT. The 192-slice DSCT system has a more powerful roentgen tube (2 × 120 kW) that allows CCTA acquisition at lower tube voltages, wider longitudinal coverage for faster table speed (732 m/s), and the use of iterative reconstruction. Objective image quality was measured as the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was evaluated using a Likert scale. RESULTS: While the effective dose was lower with 192-slice DSCT (1.2 ± 0.5 vs. 0.6 ± 0.3 mSv; P < 0.001), the SNR (18.9 ± 4.3 vs. 11.0 ± 2.9; P < 0.001) and CNR (23.5 ± 4.8 vs. 14.3 ± 4.1; P < 0.001) were superior to 128-slice DSCT. Although patients scanned with 192-slice DSCT had a faster heart rate (59 ± 7 vs. 56 ± 6; P = 0.045), subjective image quality was scored higher (4.2 ± 0.8 vs. 3.0 ± 0.7; P < 0.001) compared to 128-slice DSCT. CONCLUSIONS: High-pitch spiral CCTA by 192-slice DSCT provides better image quality, despite a higher average heart rate, at lower radiation doses compared to 128-slice DSCT.

15.
J Cardiovasc Comput Tomogr ; 10(2): 105-13, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26747231

RESUMEN

BACKGROUND: Recently several publications described the diagnostic value of coronary CT angiography (coronary CTA) derived fractional flow reserve (CTA-FFR). For a recently introduced on-site CTA-FFR application, detailed methodology and factors potentially affecting performance have not yet been described. OBJECTIVE: To provide a methodological background for an on-site CTA-FFR application and evaluate the effect of patient and acquisition characteristics. METHODS: The on-site CTA-FFR application utilized a reduced-order hybrid model applying pressure drop models within stenotic regions. In 116 patients and 203 vessels the diagnostic performance of CTA-FFR was investigated using invasive FFR measurements as a reference. The effect of several potentially relevant factors on CTA-FFR was investigated. RESULTS: 90 vessels (44%) had a hemodynamically relevant stenosis according to invasive FFR (threshold ≤0.80). The overall vessel-based sensitivity, specificity and accuracy of CTA-FFR were 88% (CI 95%:79-94%), 65% (55-73%) and 75% (69-81%). The specificity was significantly lower in the presence of misalignment artifacts (25%, CI: 6-57%). A non-significant reduction in specificity from 74% (60-85%) to 48% (26-70%) was found for higher coronary artery calcium scores. Left ventricular mass, diabetes mellitus and large vessel size increased the discrepancy between invasive FFR and CTA-FFR values. CONCLUSIONS: On-site calculation of CTA-FFR can identify hemodynamically significant CAD with an overall per-vessel accuracy of 75% in comparison to invasive FFR. The diagnostic performance of CTA-FFR is negatively affected by misalignment artifacts. CTA-FFR is potentially affected by left ventricular mass, diabetes mellitus and vessel size.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Tomografía Computarizada Multidetector , Pruebas en el Punto de Atención , Calcificación Vascular/diagnóstico por imagen , Anciano , Artefactos , Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Humanos , Hidrodinámica , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Pronóstico , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Calcificación Vascular/fisiopatología
16.
Int J Cardiovasc Imaging ; 32(2): 301-307, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26498478

RESUMEN

Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
17.
J Am Coll Cardiol ; 67(1): 16-26, 2016 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-26764061

RESUMEN

BACKGROUND: It is uncertain whether a diagnostic strategy supplemented by early coronary computed tomography angiography (CCTA) is superior to contemporary standard optimal care (SOC) encompassing high-sensitivity troponin assays (hs-troponins) for patients suspected of acute coronary syndrome (ACS) in the emergency department (ED). OBJECTIVES: This study assessed whether a diagnostic strategy supplemented by early CCTA improves clinical effectiveness compared with contemporary SOC. METHODS: In a prospective, open-label, multicenter, randomized trial, we enrolled patients presenting with symptoms suggestive of an ACS at the ED of 5 community and 2 university hospitals in the Netherlands. Exclusion criteria included the need for urgent cardiac catheterization and history of ACS or coronary revascularization. The primary endpoint was the number of patients identified with significant coronary artery disease requiring revascularization within 30 days. RESULTS: The study population consisted of 500 patients, of whom 236 (47%) were women (mean age 54 ± 10 years). There was no difference in the primary endpoint (22 [9%] patients underwent coronary revascularization within 30 days in the CCTA group and 17 [7%] in the SOC group [p = 0.40]). Discharge from the ED was not more frequent after CCTA (65% vs. 59%, p = 0.16), and length of stay was similar (6.3 h in both groups; p = 0.80). The CCTA group had lower direct medical costs (€337 vs. €511, p < 0.01) and less outpatient testing after the index ED visit (10 [4%] vs. 26 [10%], p < 0.01). There was no difference in incidence of undetected ACS. CONCLUSIONS: CCTA, applied early in the work-up of suspected ACS, is safe and associated with less outpatient testing and lower costs. However, in the era of hs-troponins, CCTA does not identify more patients with significant CAD requiring coronary revascularization, shorten hospital stay, or allow for more direct discharge from the ED. (Better Evaluation of Acute Chest Pain with Computed Tomography Angiography [BEACON]; NCT01413282).


Asunto(s)
Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/diagnóstico por imagen , Angiografía Coronaria , Servicio de Urgencia en Hospital , Tomografía Computarizada por Rayos X , Troponina/sangre , Síndrome Coronario Agudo/terapia , Anciano , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Países Bajos , Estudios Prospectivos
18.
Invest Radiol ; 49(12): 801-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25014013

RESUMEN

OBJECTIVES: Quantitative myocardial perfusion imaging by computed tomography (CT) was recently introduced to calculate myocardial blood flow (MBF). Because absolute MBF thresholds may be affected by technique, methodology, and the microvasculature, we investigated whether a relative measure of MBF improves accuracy to identify hemodynamically significant coronary stenosis. MATERIALS AND METHODS: In this prospective study, 42 patients (mean [SD] age, 62.3[8.7] years; 8 women) with suspected or known coronary disease underwent dynamic CT myocardial perfusion imaging using adenosine vasodilation, before invasive angiography (coronary angiography) with fractional flow reserve (FFR). Within each myocardial territory MBF, the MBF relative to remote myocardium (MBFratio) was calculated and compared with coronary angiography and FFR. RESULTS: Of the 91 vessels interrogated by FFR (median, 0.81; interquartile range, 0.73-0.94), 45 vessels (49%) had an FFR value lower than 0.8 and were considered hemodynamically significant. Hyperemic MBF was lower in ischemic territories: 75.6 ± 22.5 mL per 100 mL/min versus 98.3 ± 23.1 mL per 100 mL/min (P < 0.0001). The MBFratio correlated better with FFR (P = 0.76) than the absolute MBF did (P = 0.52). Receiver operating curve analysis showed better discrimination by MBFratio: area under the curve of 0.85 versus 0.75 (P = 0.02). The MBF of remote myocardium varied between 60.7 and 167.2 mL per 100 mL/min and was lower in patients without heart rate acceleration (P = 0.0035). CONCLUSIONS: The MBFratio seems to better identify hemodynamically significant coronary artery disease than does the absolute MBF determined by dynamic CT perfusion imaging. This may be caused by microvascular status or related to the methodology.


Asunto(s)
Angiografía Coronaria/métodos , Circulación Coronaria/fisiología , Estenosis Coronaria/diagnóstico por imagen , Hemodinámica/fisiología , Flujo Sanguíneo Regional/fisiología , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Eur Heart J Cardiovasc Imaging ; 15(11): 1231-7, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24939941

RESUMEN

AIMS: Non-culprit plaques are responsible for a substantial number of future events in patients with acute coronary syndrome (ACS). In this study, we evaluated the prognostic implications of non-culprit plaques seen on coronary computed tomography angiography (CTA) in patients with ACS. METHODS AND RESULTS: Coronary CTA was performed in 169 patients (mean 59 ± 11 years, 129 males) admitted with ACS. Data sets were assessed for the presence of obstructive non-culprit plaques (>50% luminal narrowing), segment involvement score, and quantitative measures of plaque burden, after censoring initial culprit plaques. Follow-up was performed for the occurrence of major adverse cardiovascular events (MACEs) unrelated to the initial culprit plaque; cardiac death, second ACS, or coronary revascularization after 90 days. After a median follow-up of 4.8 (IQR 2.6-6.6) years, MACE occurred in 36 (24%) patients: 6 cardiac deaths, 16 second ACS, and 14 coronary revascularizations. Dyslipidaemia (hazard ratio [HR] 3.1 [95% confidence interval 1.5-6.6]) and diabetes mellitus (HR 4.8 [2.3-10.3]) were univariable clinical predictors of MACE. Patients with remaining obstructive non-culprit plaques (HR 3.66 [1.52-8.80]) and higher plaque burden index (HR 1.22 [1.01-1.48]) had a more risk of MACE. In multivariate analysis, with diabetes, dyslipidaemia, and plaque burden index, obstructive non-culprit plaques (HR 3.76 [1.28-11.09]) remained an independent predictor of MACE. CONCLUSION: Almost a quarter of the study population experienced a new event arising from a non-culprit plaque during a follow-up of almost 5 years. ACS patients with remaining obstructive non-culprit plaques or high plaque burden have an increased risk of future MACE.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico por imagen , Angiografía Coronaria/métodos , Placa Aterosclerótica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Síndrome Coronario Agudo/mortalidad , Biomarcadores/análisis , Comorbilidad , Medios de Contraste , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/mortalidad , Valor Predictivo de las Pruebas , Pronóstico , Interpretación de Imagen Radiográfica Asistida por Computador , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA