Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Physiol ; 602(1): 73-91, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38041645

RESUMEN

Vascular production of nitric oxide (NO) regulates vascular tone. However, highly permeable NO entering the cardiomyocyte would profoundly impact metabolism and signalling without scavenging mechanisms. The purpose of this study was to establish mechanisms of cardiac NO scavenging. Quantitative optical studies of normoxic working hearts demonstrated that micromolar NO concentrations did not alter mitochondria redox state or respiration despite detecting NO oxidation of oxymyoglobin to metmyoglobin. These data are consistent with proposals that the myoglobin/myoglobin reductase (Mb/MbR) system is the major NO scavenging site. However, kinetic studies in intact hearts reveal a minor role (∼9%) for the Mb/MbR system in NO scavenging. In vitro, oxygenated mitochondria studies confirm that micromolar concentrations of NO bind cytochrome oxidase (COX) and inhibit respiration. Mitochondria had a very high capacity for NO scavenging, importantly, independent of NO binding to COX. NO is also known to quickly react with reactive oxygen species (ROS) in vitro. Stimulation of NO scavenging with antimycin and its inhibition by substrate depletion are consistent with NO interacting with ROS generated in Complex I or III under aerobic conditions. Extrapolating these in vitro data to the intact heart supports the hypothesis that mitochondria are a major site of cardiac NO scavenging. KEY POINTS: Cardiomyocyte scavenging of vascular nitric oxide (NO) is critical in maintaining normal cardiac function. Myoglobin redox cycling via myoglobin reductase has been proposed as a major NO scavenging site in the heart. Non-invasive optical spectroscopy was used to monitor the effect of NO on mitochondria and myoglobin redox state in intact beating heart and isolated mitochondria. These non-invasive studies reveal myoglobin/myoglobin reductase plays a minor role in cardiac NO scavenging. A high capacity for NO scavenging by heart mitochondria was demonstrated, independent of cytochrome oxidase binding but dependent on oxygen and high redox potentials consistent with generation of reactive oxygen species.


Asunto(s)
Mioglobina , Óxido Nítrico , Mioglobina/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Óxido Nítrico/metabolismo , Complejo IV de Transporte de Electrones/metabolismo , Cinética , Miocitos Cardíacos/metabolismo , Oxidación-Reducción , Mitocondrias Cardíacas/metabolismo , Consumo de Oxígeno
2.
Proc Natl Acad Sci U S A ; 114(18): 4805-4810, 2017 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-28373558

RESUMEN

The artery wall is equipped with a water permeation barrier that allows blood to flow at high pressure without significant water leak. The precise location of this barrier is unknown despite its importance in vascular function and its contribution to many vascular complications when it is compromised. Herein we map the water permeability in intact arteries, using coherent anti-Stokes Raman scattering (CARS) microscopy and isotopic perfusion experiments. Generation of the CARS signal is optimized for water imaging with broadband excitation. We identify the water permeation barrier as the endothelial basolateral membrane and show that the apical membrane is highly permeable. This is confirmed by the distribution of the AQP1 water channel within endothelial membranes. These results indicate that arterial pressure equilibrates within the endothelium and is transmitted to the supporting basement membrane and internal elastic lamina macromolecules with minimal deformation of the sensitive endothelial cell. Disruption of this pressure transmission could contribute to endothelial cell dysfunction in various pathologies.


Asunto(s)
Acuaporina 1/metabolismo , Arterias , Permeabilidad Capilar , Endotelio Vascular , Microscopía Óptica no Lineal , Animales , Arterias/diagnóstico por imagen , Arterias/metabolismo , Endotelio Vascular/diagnóstico por imagen , Endotelio Vascular/metabolismo , Masculino , Ratas , Ratas Sprague-Dawley
3.
J Microsc ; 260(2): 180-93, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26224257

RESUMEN

This paper investigates a postprocessing approach to correct spatial distortion in two-photon fluorescence microscopy images for vascular network reconstruction. It is aimed at in vivo imaging of large field-of-view, deep-tissue studies of vascular structures. Based on simple geometric modelling of the object-of-interest, a distortion function is directly estimated from the image volume by deconvolution analysis. Such distortion function is then applied to subvolumes of the image stack to adaptively adjust for spatially varying distortion and reduce the image blurring through blind deconvolution. The proposed technique was first evaluated in phantom imaging of fluorescent microspheres that are comparable in size to the underlying capillary vascular structures. The effectiveness of restoring three-dimensional (3D) spherical geometry of the microspheres using the estimated distortion function was compared with empirically measured point-spread function. Next, the proposed approach was applied to in vivo vascular imaging of mouse skeletal muscle to reduce the image distortion of the capillary structures. We show that the proposed method effectively improve the image quality and reduce spatially varying distortion that occurs in large field-of-view deep-tissue vascular dataset. The proposed method will help in qualitative interpretation and quantitative analysis of vascular structures from fluorescence microscopy images.


Asunto(s)
Microscopía Fluorescente , Microvasos/ultraestructura , Algoritmos , Animales , Artefactos , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Microscopía Intravital/métodos , Ratones , Microscopía Fluorescente/instrumentación , Microscopía Fluorescente/métodos , Modelos Teóricos , Músculo Esquelético/irrigación sanguínea , Músculo Esquelético/ultraestructura , Fantasmas de Imagen , Fotones , Reproducibilidad de los Resultados
4.
Biochim Biophys Acta Bioenerg ; 1864(2): 148934, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36379270

RESUMEN

The catalytic cycle of cytochrome c oxidase (COX) couples the reduction of oxygen to the translocation of protons across the inner mitochondrial membrane and involves several intermediate states of the heme a3-CuB binuclear center with distinct absorbance properties. The absorbance maximum close to 605 nm observed during respiration is commonly assigned to the fully reduced species of hemes a or a3 (R). However, by analyzing the absorbance of isolated enzyme and mitochondria in the Soret (420-450 nm), alpha (560-630 nm) and red (630-700 nm) spectral regions, we demonstrate that the Peroxy (P) and Ferryl (F) intermediates of the binuclear center are observed during respiration, while the R form is only detectable under nearly anoxic conditions in which electrons also accumulate in the higher extinction coefficient low spin a heme. This implies that a large fraction of COX (>50 %) is active, in contrast with assumptions that assign spectral changes only to R and/or reduced heme a. The concentration dependence of the COX chromophores and reduced c-type cytochromes on the transmembrane potential (ΔΨm) was determined in isolated mitochondria during substrate or apyrase titration to hydrolyze ATP. The cytochrome c-type redox levels indicated that soluble cytochrome c is out of equilibrium with respect to both Complex III and COX. Thermodynamic analyses confirmed that reactions involving the chromophores we assign as the P and F species of COX are ΔΨm-dependent, out of equilibrium, and therefore much slower than the ΔΨm-insensitive oxidation of the R intermediate, which is undetectable due to rapid oxygen binding.


Asunto(s)
Complejo IV de Transporte de Electrones , Mitocondrias Cardíacas , Complejo IV de Transporte de Electrones/metabolismo , Mitocondrias Cardíacas/metabolismo , Citocromos c/metabolismo , Análisis Espectral , Oxígeno/metabolismo , Hemo/metabolismo
5.
Opt Lett ; 35(12): 2046-8, 2010 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-20548381

RESUMEN

Interferometric synthetic aperture arrays (SAA) can be refocused at any range via digital processing of the raw data, called the visibility function. Such systems are sensitive, however, to ranging errors in digital refocusing. They, therefore, exhibit a limited depth of focus, because these errors are equivalent to introducing defocus in the system. We derive an analytical expression for the Strehl ratio of synthetic aperture arrays, which accounts for both the antenna voltage pattern and the focal shift factor encountered in imaging systems with a low Fresnel number. Assessment of the depth of focus of short-range imaging arrays is allowed and is illustrated for common array designs.

6.
PLoS One ; 13(8): e0203319, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30161240

RESUMEN

Hard x-ray lenses are useful elements in x-ray microscopy and in creating focused illumination for analytical applications such as x-ray fluorescence imaging. Recently, polymer compound refractive lenses for focused illumination in the soft x-ray regime (< 10 keV) have been created with nano-printing. However, there are no such lenses yet for hard x-rays, particularly of short focal lengths for benchtop microscopy. We report the first instance of a nano-printed lens for hard x-ray microscopy, and evaluate its imaging performance. The lens consists of a spherically focusing compound refractive lens designed for 22 keV photon energy, with a tightly packed structure to provide a short total length of 1.8 mm and a focal length of 21.5 mm. The resulting lens technology was found to enable benchtop microscopy at 74x magnification and 1.1 µm de-magnified image pixel size at the object plane. It was used to image and evaluate the focal spots of tungsten-anode micro-focus x-ray sources. The overall system resolution with broadband illumination from a tungsten-anode x-ray tube at 30 kV and 10 mm focal distance was measured to be 2.30±0.22 µm.


Asunto(s)
Lentes , Microscopía/instrumentación , Nanoestructuras , Impresión Tridimensional , Radiografía/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Tungsteno , Rayos X
7.
J Histochem Cytochem ; 63(1): 8-21, 2015 01.
Artículo en Inglés | MEDLINE | ID: mdl-25362141

RESUMEN

Using the intrinsic optical properties of collagen and elastin, two-photon microscopy was applied to evaluate the three-dimensional (3D) macromolecular structural development of the mouse thoracic aorta from birth to 60 days old. Baseline development was established in the Scavenger Receptor Class B Type I-Deficient, Hypomorphic Apolipoprotein ER61 (SR-BI KO/ApoeR61(h/h)) mouse in preparation for modeling atherosclerosis. Precise dissection enabled direct observation of the artery wall in situ. En-face, optical sectioning of the aorta provided a novel assessment of the macromolecular structural development. During aortic development, the undulating lamellar elastin layers compressed consistent with the increases in mean aortic pressure with age. In parallel, a net increase in overall wall thickness (p<0.05, in day 60 compared with day 1 mice) occurred with age whereas the ratio of the tunicas adventitia and media to full aortic thickness remained nearly constant across age groups (~1:2.6, respectively). Histochemical analyses by brightfield microscopy and ultrastructure validated structural proteins and lipid deposition findings derived from two-photon microscopy. Development was associated with decreased decorin but not biglycan proteoglycan expression. This non-destructive 3D in situ approach revealed the aortic wall microstructure development. Coupling this approach with the intrinsic optical properties of the macromolecules may provide unique vascular wall 3D structure in many pathological conditions, including aortic atherosclerosis, dissections and aneurysms.


Asunto(s)
Aorta Torácica/crecimiento & desarrollo , Microscopía de Fluorescencia por Excitación Multifotónica , Animales , Aorta Torácica/citología , Aorta Torácica/metabolismo , Apolipoproteínas E/deficiencia , Apolipoproteínas E/genética , Antígenos CD36/deficiencia , Antígenos CD36/genética , Técnicas de Inactivación de Genes , Imagenología Tridimensional , Ratones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA