Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Appl Psychophysiol Biofeedback ; 47(3): 213-222, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35704121

RESUMEN

Pulse rate variability is a physiological parameter that has been extensively studied and correlated with many physical ailments. However, the phase relationship between inter-beat interval, IBI, and breathing has very rarely been studied. Develop a technique by which the phase relationship between IBI and breathing can be accurately and efficiently extracted from photoplethysmography (PPG) data. A program based on Lock-in Amplifier technology was written in Python to implement a novel technique, Dynamic Phase Extraction. It was tested using a breath pacer and a PPG sensor on 6 subjects who followed a breath pacer at varied breathing rates. The data were then analyzed using both traditional methods and the novel technique (Dynamic Phase Extraction) utilizing a breath pacer. Pulse data was extracted using a PPG sensor. Dynamic Phase Extraction (DPE) gave the magnitudes of the variation in IBI associated with breathing [Formula: see text] measured with photoplethysmography during paced breathing (with premature ventricular contractions, abnormal arrhythmias, and other artifacts edited out). [Formula: see text] correlated well with two standard measures of pulse rate variability: the Standard Deviation of the inter-beat interval (SDNN) (ρ = 0.911) and with the integrated value of the Power Spectral Density between 0.04 and 0.15 Hz (Low Frequency Power or LF Power) (ρ = 0.885). These correlations were comparable to the correlation between the SDNN and the LF Power (ρ = 0.877). In addition to the magnitude [Formula: see text], Dynamic Phase Extraction also gave the phase between the breath pacer and the changes in the inter-beat interval (IBI) due to respiratory sinus arrythmia (RSA), and correlated well with the phase extracted using a Fourier transform (ρ = 0.857). Dynamic Phase Extraction can extract both the phase between the breath pacer and the changes in IBI due to the respiratory sinus arrhythmia component of pulse rate variability ([Formula: see text], but is limited by needing a breath pacer.


Asunto(s)
Arritmia Sinusal Respiratoria , Procesamiento de Señales Asistido por Computador , Electrocardiografía , Frecuencia Cardíaca/fisiología , Humanos , Fotopletismografía/métodos , Frecuencia Respiratoria
2.
Rev Sci Instrum ; 91(8): 084102, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32872917

RESUMEN

The bone material strength index (BMSi), as measured by the OsteoProbe, is significantly correlated with Vickers hardness and Rockwell (RW) hardness measurements on conventional materials. The Vickers and RW measurements were carried out according to American Society for Testing and Materials standard test methods, and OsteoProbe measurements followed published standardized testing methods. The correlations between the BMSi and RW hardness, r = 0.93, and between the BMSi and Vickers hardness, r = 0.94, are comparable with the correlation between RW and Vickers hardness, r = 0.87. The correlation between the BMSi and RW is significant at p < 0.01, and the correlation between the BMSi and Vickers hardness is significant at p < 0.01. These results show that the indentation measurement performed by the OsteoProbe may be considered as a type of hardness measurement comparable to widely used conventional methods, with specific applications targeted by its portable and narrow design.


Asunto(s)
Materiales Biocompatibles , Huesos , Ensayo de Materiales/instrumentación , Fenómenos Mecánicos , Dureza
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA