1.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38483647

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Resultado del Tratamiento , Aneurisma Intracraneal/cirugía , Aneurisma Intracraneal/etiología , Embolización Terapéutica/efectos adversos , Puntaje de Propensión , Estudios Retrospectivos , Estudios de Cohortes , Procedimientos Endovasculares/efectos adversos
2.
Neurosurg Rev ; 47(1): 374, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39083214

RESUMEN

The Woven EndoBridge (WEB) device is primarily used for treating wide-neck intracranial bifurcation aneurysms under 10 mm. Limited data exists on its efficacy for large aneurysms. We aim to assess angiographic and clinical outcomes of the WEB device in treating large versus small aneurysms. We conducted a retrospective review of the WorldWide WEB Consortium database, from 2011 to 2022, across 30 academic institutions globally. Propensity score matching (PSM) was employed to compare small and large aneurysms on baseline characteristics. A total of 898 patients were included. There was no significant difference observed in clinical presentations, smoking status, pretreatment mRS, presence of multiple aneurysms, bifurcation location, or prior treatment between the two groups. After PSM, 302 matched pairs showed significantly lower last follow-up adequate occlusion rates (81% vs 90%, p = 0.006) and higher retreatment rates (12% vs 3.6%, p < 0.001) in the large aneurysm group. These findings may inform treatment decisions and patient counseling. Future studies are needed to further explore this area.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal , Puntaje de Propensión , Humanos , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/cirugía , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Adulto , Embolización Terapéutica/métodos
3.
J Stroke Cerebrovasc Dis ; 33(11): 107897, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39069148

RESUMEN

INTRODUCTION: The Woven EndoBridge (WEB) device is emerging as a novel therapy for intracranial aneurysms, but its use for off-label indications requires further study. Using machine learning, we aimed to develop predictive models for complete occlusion after off-label WEB treatment and to identify factors associated with occlusion outcomes. METHODS: This multicenter, retrospective study included 162 patients who underwent off-label WEB treatment for intracranial aneurysms. Baseline, morphological, and procedural variables were utilized to develop machine-learning models predicting complete occlusion. Model interpretation was performed to determine significant predictors. Ordinal regression was also performed with occlusion status as an ordinal outcome from better (Raymond Roy Occlusion Classification [RROC] grade 1) to worse (RROC grade 3) status. Odds ratios (OR) with 95 % confidence intervals (CI) were reported. RESULTS: The best performing model achieved an AUROC of 0.8 for predicting complete occlusion. Larger neck diameter and daughter sac were significant independent predictors of incomplete occlusion. On multivariable ordinal regression, higher RROC grades (OR 1.86, 95 % CI 1.25-2.82), larger neck diameter (OR 1.69, 95 % CI 1.09-2.65), and presence of daughter sacs (OR 2.26, 95 % CI 0.99-5.15) were associated with worse aneurysm occlusion after WEB treatment, independent of other factors. CONCLUSION: This study found that larger neck diameter and daughter sacs were associated with worse occlusion after WEB therapy for aneurysms. The machine learning approach identified anatomical factors related to occlusion outcomes that may help guide patient selection and monitoring with this technology. Further validation is needed.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal , Aprendizaje Automático , Uso Fuera de lo Indicado , Humanos , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Factores de Riesgo , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Prótesis Vascular , Diseño de Prótesis , Técnicas de Apoyo para la Decisión , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Adulto , Toma de Decisiones Clínicas , Medición de Riesgo
4.
Radiology ; 304(2): 372-382, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35438564

RESUMEN

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Aneurisma Roto/terapia , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
5.
J Stroke Cerebrovasc Dis ; 29(11): 105240, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33066881

RESUMEN

BACKGROUND: Gender differences are often reported in the field of ischemic stroke, although most of such discrepancies were observed in randomized trials involving highly selected populations. We therefore explored gender differences regarding 90-day outcomes in large vessel occlusion (LVO) strokes receiving endovascular treatment in a real world setting. METHODS: This prospective registry included anterior and/or posterior circulation LVO strokes admitted between January 2014 and December 2019 who received mechanical thrombectomy up to 24 hours from symptoms onset or last known to be well. We explored sex-related differences in rates of functional independence (modified Rankin Scale, mRS, ≤2) at 90 days. Secondary outcomes included "National Institutes of Health Stroke Scale" (NIHSS) at 24 hours, successful reperfusion defined as modified Thrombolysis in Cerebral Infarction (mTICI) scale 2b/3, death, and symptomatic intracranial hemorrhage (sICH). RESULTS: A total of 288 LVO stroke patients comprised the study population, involving 148 (51.4%) women. Females were older (71.4±15.7 vs. 66.1±14.0 years, p=0.003) and had lower rates of coronary artery disease (15% vs. 24%, p=0.05). The median time from symptoms onset to hospital arrival was 315 min (IQR 139.5-495.0) in females and 255.0 (IQR 117.0-405.0) in males (p=0.052). Rates of mRS ≤2 at 90 days were comparable (females 46% vs. males 49%, p=0.50). Successful reperfusion was achieved in 82% of females and 89% of males (p=0.10). Rates of sICH (females 10% vs. males 13%, p=0.47) and death (females 18% vs. males 21%, p=0.50) at 90 days were similar. NIHSS at 24 hours was the strongest predictor of functional independence at 90 days (area under ROC curve 0.92 (95%CI 0.87; 0.95)]. CONCLUSIONS: Our prospective registry involving a real world setting suggests that females are equally likely to achieve good outcomes after endovascular treatment despite being older and having delayed hospital arrival compared to males. In addition, we found that NIHSS at 24 hours was the strongest predictor of functional independence at 90 days, sICH, and death.


Asunto(s)
Isquemia Encefálica/terapia , Procedimientos Endovasculares , Disparidades en el Estado de Salud , Accidente Cerebrovascular/terapia , Factores de Edad , Anciano , Anciano de 80 o más Años , Argentina , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/mortalidad , Isquemia Encefálica/fisiopatología , Evaluación de la Discapacidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recuperación de la Función , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/fisiopatología , Factores de Tiempo , Tiempo de Tratamiento , Resultado del Tratamiento
6.
Stroke ; 53(2): e47-e49, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34915737
7.
Interv Neuroradiol ; : 15910199241231018, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689478

RESUMEN

BACKGROUND: The PEDESTRIAN registry demonstrated high rates of complete long-term occlusion and good clinical outcomes among patients with intracranial aneurysms treated with the pipeline embolization device. The pipeline flex embolization device with shield technology was introduced to minimize thromboembolic complications. In this study, we investigated the safety and effectiveness of pipeline embolization device with shield technology among all patients treated for intracranial aneurysms at our center. METHODS: This was a single-arm retrospective study of prospectively collected data of patients treated with pipeline embolization device with shield technology at our high-volume center between January 2018-January 2021. The primary efficacy endpoint was complete occlusion as measured by a class 1 Raymond-Roy score at 1-year and 2-year follow-up. The primary safety endpoint was major morbidity and neurological mortality up to 1 year following intervention. RESULTS: A total of 328 patients (mean age 56.1 ± 14.7 years; 81.1% female), 80 of whom were previously included in PEDESTRIAN, with 396 aneurysms, were analyzed. A total of 378 devices were deployed, with 93.9% (372/396) of aneurysms requiring only one device. Follow-up angiography was available for 90.2% (296/328) of the procedures after a mean time of 14.0 ± 8.2 months. Complete occlusion was demonstrated for 78.5% (132/168) of aneurysms at 12 months and 90.7% (98/108) at 24 months. The overall rates of major morbidity and neurological mortality after 2 years were 1.5% (5/328) and 0.6% (2/328), respectively. CONCLUSION: Our results demonstrate high rates of complete long-term occlusion among patients treated with pipeline embolization device with shield technology. We also observed low rates of mortality and morbidity consistent with fewer thromboembolic complications with pipeline embolization devices with shield technology.

8.
Sci Transl Med ; 16(747): eadl4497, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38748771

RESUMEN

Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography (nOCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The nOCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using nOCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. nOCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.


Asunto(s)
Arterias Cerebrales , Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Humanos , Arterias Cerebrales/diagnóstico por imagen , Microscopía/métodos , Miniaturización , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos
9.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862717

RESUMEN

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Stents
10.
J Neurosurg ; 141(4): 992-999, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38701528

RESUMEN

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.


Asunto(s)
Procedimientos Endovasculares , Aneurisma Intracraneal , Inhibidores de Agregación Plaquetaria , Tromboembolia , Humanos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/uso terapéutico , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Tromboembolia/prevención & control , Tromboembolia/etiología , Anciano , Procedimientos Endovasculares/métodos , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Adulto
11.
J Neurosurg ; : 1-11, 2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39393093

RESUMEN

OBJECTIVE: The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors' objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS: The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS: The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS: This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.

12.
J Neurointerv Surg ; 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38238006

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

13.
Interv Neuroradiol ; : 15910199241267320, 2024 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-39127463

RESUMEN

BACKGROUND: Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond-Roy classification 1 or 2) remains challenging. OBJECTIVE: Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. METHODS: We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. RESULTS: A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535-0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024-0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer-Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/. CONCLUSION: The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.

14.
AJNR Am J Neuroradiol ; 45(7): 906-911, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977286

RESUMEN

BACKGROUND AND PURPOSE: Despite the numerous studies evaluating the occlusion rates of aneurysms following WEB embolization, there are limited studies identifying predictors of occlusion. Our purpose was to identify predictors of aneurysm occlusion and the need for retreatment. MATERIALS AND METHODS: This is a review of a prospectively maintained database across 30 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB who had available intraprocedural data and long-term follow-up. RESULTS: We studied 763 patients with a mean age of 59.9 (SD, 11.7) years. Complete aneurysm occlusion was observed in 212/726 (29.2%) cases, and contrast stasis was observed in 485/537 (90.3%) of nonoccluded aneurysms. At the final follow-up, complete occlusion was achieved in 497/763 (65.1%) patients, and retreatment was required for 56/763 (7.3%) patients. On multivariable analysis, history of smoking, maximal aneurysm diameter, and the presence of an aneurysm wall branch were negative predictors of complete occlusion (OR, 0.5, 0.8, and 0.4, respectively). Maximal aneurysm diameter, the presence of an aneurysm wall branch, posterior circulation location, and male sex increase the chances of retreatment (OR, 1.2, 3.8, 3.0, and 2.3 respectively). Intraprocedural occlusion resulted in a 3-fold increase in the long-term occlusion rate and a 5-fold decrease in the retreatment rate (P < .001), offering a specificity of 87% and a positive predictive value of 85% for long-term occlusion. CONCLUSIONS: Intraprocedural occlusion can be used to predict the chance of long-term aneurysm occlusion and the need for retreatment after embolization with a WEB device. Smoking, aneurysm size, and the presence of an aneurysm wall branch are associated with decreased chances of successful treatment.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/cirugía , Masculino , Femenino , Persona de Mediana Edad , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Anciano , Factores de Riesgo
15.
Medicina (B Aires) ; 83(5): 705-718, 2023.
Artículo en Español | MEDLINE | ID: mdl-37870328

RESUMEN

INTRODUCTION: The start of the COVID-19 pandemic forced the implementation of changes in the emergency services care system. Concomitantly, at our institution, we implemented the artificial intelligence (AI) software, RAPID.AI, for image analysis in ischemic stroke (IS). Our objective was to evaluate the impact of the use of AI together with the changes in the triage during the COVID-19 pandemic in patients with stroke due to large vessel occlusion (LVO). METHODS: We included patients with IS due to LVO treated with intravenous reperfusion therapy plus endovascular or direct endovascular therapy. RESULTS: Two groups were created. Group 1: patients from January 2019 to June 2020; Group 2: patients from July 2020 to December 2021, studied with RAPID.AI. Clinical data and temporal metrics were analyzed. They were compared according to arrival time from 08:00 to 20:00 (daytime) vs 20:01 to 7:59 (night). RESULTS: We included 286 patients, 153 in group 1 and 133 in group 2. In group 2, door-image metric and image duration were lower, with shorter door-image onset and door-recanalization times; patients who arrived at night had higher NIHSS and longer time from onset-to-door with lower proportion of functional independence at 90 days (mRS = 2). CONCLUSIONS: The use of AI for image analysis along with a shorter door to end of image time allowed to reduce the interval to groin puncture. In the analysis by hours during the pandemic, patients admitted in daytime hours had significantly lower door to image, image time acquisition, and door to recanalization metrics.


Introducción: El inicio de la pandemia COVID-19, obligó a implementar cambios en el sistema de atención de los servicios de emergencia. Coincidentemente, en nuestra institución, implementamos el software de inteligencia artificial (IA), RAPID.AI, para el análisis de imágenes en el ataque cerebrovascular isquémico (ACVi). Nuestro objetivo fue evaluar el impacto del uso de la IA junto a los cambios en el triage durante la pandemia por COVID-19 en pacientes con ACVi por oclusión de gran vaso cerebral (OGVC). Métodos: Se crearon 2 grupos de pacientes con ACVi por OGVC tratados con terapia de reperfusión endovenosa más endovascular o terapia endovascular directa. Grupo 1: pacientes de enero 2019 a junio 2020; Grupo 2: pacientes de julio 2020 a diciembre de 2021, estudiados con RAPID.AI. Se analizaron datos clínicos, y métricas temporales. Se compararon según hora de arribo de 08:00 a 20:00 h (diurno) vs. 20:01 a 7:59 h (nocturno). Resultados: El grupo 1 comprendió 153 pacientes y el grupo 2 133. En el grupo 2 la métrica puerta-imagen y adquisición de la imagen fueron menores, con menor tiempo puerta-inicio de imagen y puerta-recanalización; los pacientes en horario nocturno presentaron mayor NIHSS y tiempos inicio-ingreso con menor proporción de independencia funcional a 90 días. Conclusiones: El uso de la IA para el análisis de imágenes junto a un menor tiempo puerta-fin de imagen, permitió acortar el intervalo hasta la punción inguinal. En el análisis por horarios durante la pandemia, los pacientes ingresados en horario diurno presentaron métricas puerta-imagen, tiempo de imagen y puertarecanalización significativamente menores.


Asunto(s)
Isquemia Encefálica , COVID-19 , Accidente Cerebrovascular , Humanos , Pandemias , Trombectomía/métodos , Inteligencia Artificial , Accidente Cerebrovascular/terapia , Accidente Cerebrovascular/epidemiología , Resultado del Tratamiento , Tiempo de Tratamiento , Isquemia Encefálica/terapia , Estudios Retrospectivos
16.
J Neurointerv Surg ; 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38124177

RESUMEN

BACKGROUND: The aim of this study was to evaluate the overall rates of braid changes associated with flow diverter (FD) treatment for intracranial aneurysms (IAs). Additionally, we sought to provide an overview of the currently reported definitions related to these complications. METHODS: A systematic search was conducted from the inception of relevant literature up to April 2023, encompassing six databases. The included studies focused on patients with IAs treated with FDs. We considered four main outcome measures as FD braid changes: (1) fish-mouthing, (2) device braid narrowing, (3) device braid collapsing, and (4) device braid deformation. The data from these studies were pooled using a random-effects model. RESULTS: A total of 48 studies involving 3572 patients were included in the analysis. Among them, 14 studies (39%) provided definitions for fish-mouthing. However, none of the included studies offered specific definitions for device braid narrowing, collapsing, or deformation, despite reporting rates for these complications in six, five, and three studies, respectively. The pooled rates for braid changes were as follows: 3% (95% CI 2% to 4%, I2=27%) for fish-mouthing, 7% (95% CI 2% to 20%, I2=85%) for narrowing, 1% (95% CI 0% to 3%, I2=0%) for collapsing, and 1% (95% CI 1% to 4%, I2=0%) for deformation. CONCLUSION: The findings of this study suggest that FD treatment for IAs generally exhibits low rates of fish-mouthing, device braid narrowing, collapsing, and deformation. However, the lack of standardized definitions hinders the ability to compare device outcomes objectively, emphasizing the need for uniform definitions for FD braid changes in future prospective studies on FD.

17.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35868856

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Resultado del Tratamiento , Procedimientos Endovasculares/métodos , Estudios Retrospectivos , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/cirugía , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Embolización Terapéutica/métodos
18.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36066701

RESUMEN

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
19.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35483912

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Asunto(s)
Enfermedades de las Arterias Carótidas , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Enfermedades de las Arterias Carótidas/terapia
20.
J Neurointerv Surg ; 14(5)2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34862267

RESUMEN

Surgical ventriculoperitoneal shunting remains standard treatment for communicating hydrocephalus, despite persistently elevated infection and revision rates. A novel minimally invasive endovascular cerebrospinal fluid (CSF) shunt was developed to mimic the function of the arachnoid granulation which passively filters CSF from the central nervous system back into the intracranial venous sinus network. The endovascular shunt is deployed via a femoral transvenous approach across the dura mater into the cerebellopontine angle cistern. An octogenarian with intractable hydrocephalus following subarachnoid hemorrhage underwent successful endovascular shunting, resulting in swift intracranial pressure reduction from 38 to <20 cmH2O (<90 min) and resolution of ventriculomegaly. This first successful development of a percutaneous transluminal venous access to the central nervous system offers a new pathway for non-invasive treatment of hydrocephalus and the potential for intervention against neurological disorders.


Asunto(s)
Biomimética , Hidrocefalia , Anciano de 80 o más Años , Ángulo Pontocerebeloso/cirugía , Derivaciones del Líquido Cefalorraquídeo/métodos , Humanos , Hidrocefalia/diagnóstico por imagen , Hidrocefalia/etiología , Hidrocefalia/cirugía , Imagen por Resonancia Magnética/métodos , Derivación Ventriculoperitoneal/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA