RESUMEN
We attempted to improve the loop-mediated isothermal amplification (LAMP) method for malaria diagnosis by using a simple DNA extraction procedure, and a portable device performing both the amplification and detection of LAMP in one platform. Additionally, the device served as a heating block for the DNA preparation. We refer this method as LAMP-Tube scanner, and evaluated using 209 microscopically positive malaria samples and compared them to RDTs and LAMP-Thermocycler. Two most common human infecting Plasmodium species were detected. The LAMP-Tube scanner method is found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was closely less than 60 min. Sensitivity and specificity of LAMP-Tube scanner in detecting Plasmodium falciparum were 95% and 93.3%, compared to microscopy and 98.3% and 100% respectively, compared to standard LAMP-Thermocycler. In addition, it showed a detection limit of 10 and 40 copies of the parasitemia for Plasmodium vivax and P. falciparum. Accordingly, in comparison to the results obtained by microscopy, the LAMP-Tube scanner had a less divergence in sensitivity and specificity, and yielded results similar to those of LAMP-Thermocycler. This method has the great potential as a field usable molecular tool for the diagnosis of malaria and is an alternative to conventional PCR-based diagnostic methods for field use.
Asunto(s)
ADN Protozoario/aislamiento & purificación , Malaria/diagnóstico , Técnicas de Amplificación de Ácido Nucleico/métodos , Plasmodium falciparum/genética , Plasmodium vivax/genética , ADN Protozoario/sangre , Humanos , Malaria/parasitología , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/normas , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Especificidad de la EspecieRESUMEN
Hepatitis B virus is a highly infectious blood borne microbial pathogen that causes several hepatic complications like liver cirrhosis and hepatocellular carcinoma. Several methods are available for the detection of HBV, but every method has their own merits and demerits, which restrict their use in clinical laboratories. The aim of this present study is the development of rapid, inexpensive, sensitive, and specific loop-mediated isothermal amplification followed by lateral flow device (LFD) for detection of HBV in blood specimens. METHODS: HBV standard plasma panels and donor plasma specimens were used to evaluate the assay. HBV DNA was extracted by using QiAamp DNA Blood Mini Kit. Amplification was carried out at constant temperature 63 °C for 60 min. LAMP end products were analyzed by using ESE LAMP tube scanner, gel electrophoresis, UV-lamp, and lateral flow device. RESULTS: HBV-LAMP-LFD assay revealed sensitivity of 92% (138/150) of HBV positive plasma specimens. Specificity of HBV-LAMP-LFD was calculated 100%. CONCLUSION: Our study concludes that HBV-LAMP-LFD is rapid, easy to use, sensitive, and specific point-of-care diagnostic assay for the detection of hepatitis B virus in blood samples. This assay can be used in resource-limited settings as well as in HBV endemic areas.
Asunto(s)
Virus de la Hepatitis B , Hepatitis B , Hepatitis B/diagnóstico , Virus de la Hepatitis B/genética , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico/métodos , Sensibilidad y EspecificidadRESUMEN
Malaria is a fatal life-threatening parasitic infection and a leading cause of morbidity and mortality. The present study was aimed to evaluate simple, inexpensive, accurate, reliable, easily available better diagnostic for rapid detection of malaria at point of care (POC). The study includes 1403 samples collected from the patients, of which 1227 were clinically suspected cases and 176 from consecutive feverish patients. Among the suspected cases only 338 samples were confirmed positive and 889 samples were negative for Plasmodium species by PCR. All the 889 samples showed negative result for plasmodium species by microscopy, Malarial Ag rapid kits but only 867 samples were confirmed negative with malarial Ab rapid kits. Of the 338 PCR positive samples, 337 samples were confirmed positive by microscopy and Malarial Ag rapid kits, but only 284 samples were confirmed positive using malarial Ab rapid kits. Overall the microscopy and the malaria antigen-based lateral flow assay exhibited similar sensitivity, specificity, PPV, NPV and efficiency, respectively, whereas the PCR assay had 100% sensitivity, specificity, PPV, NPV and efficiency. But the evolutionary data for malaria antibody lateral flow assay has 92.81% sensitivity, 94.13% specificity, 84.02% PPV, 97.52% NPV and 93.80% efficiency. The developed Malaria pf/pv antigen and antibody field-deployable kits are simple, rapid, accurate, reliable, inexpensive, user friendly, POC. In addition the kits are highly sensitive and species-specific. The pf/pv antigen kit is found to be more accurate with 99.7% sensitivity and 100% specificity than to Malaria pf/pv antibody rapid kits. Of the two rapid kits developed, Malaria pf/pv antigen kit is found be more accurate with 99.7% sensitivity and 100% specificity than to Malaria pf/pv antibody rapid kits.
RESUMEN
The Mycobacterium avium subspecies paratuberculosis (MAP) causes paratuberculosis (Johne's disease), a systemic and chronic inflammation of intestine that affects bovine, small ruminants like goat and sheep. The disease has a greater economic importance in cattle and in small ruminants. But its effective control is impeded due to lack of rapid and accurate diagnostics. The present study is aimed at developing a LAMP-coupled lateral flow device (LFD) for rapid detection of paratuberculosis in livestock animal species such as cattle and in small ruminants at resource-limited areas. LAMP primers with biotin and FITC end tags were designed for IS900 gene specific for MAP. To determine sensitivity of LAMP assay, 10-fold serial dilutions were made from 10 ng/µl MAP stock DNA and were compared with PCR. The detection limits of LAMP-coupled LFD were defined and reactions were repeated for reproducibility. The specificity was evaluated using other infectious bacteria such as M. bovis, M. tuberculosis, Brucella abortus, Leptospira interrogan, Yersinia enterocolitica, Salmonella typhimurium, Listeria monocytogens, and Staphylococcus aureus. A total of 95 samples turned positive for LAMP-coupled LFD out of 389 fecal samples. All the cultural-positive and PCR-positive samples showed positive in LAMP-coupled LFD. Nine samples with negative cultures turned positive in LAMP assay. The overall sensitivity and specificity of the LAMP-coupled LFD assays were 100% and 97.02% respectively in comparison with the culture as the gold standard method. The sensitivity detection limit of developed assay was 10 fg/µl and specificity was 100%. This assay successfully detected MAP not only by using bacterial DNA but also in clinical fecal samples. The clear band formation at control and test positions was observed on LAMP-coupled LFD. The developed assay is a simple, rapid, easy to perform, and is very useful in early diagnosis of Mycobacterium avium subsp. paratuberculosis at point of care resource-limited areas.
Asunto(s)
Mycobacterium avium subsp. paratuberculosis/aislamiento & purificación , Técnicas de Amplificación de Ácido Nucleico/métodos , Paratuberculosis/microbiología , Animales , Bovinos , Enfermedades de los Bovinos/diagnóstico , Enfermedades de los Bovinos/microbiología , Cartilla de ADN/genética , Enfermedades de las Cabras/diagnóstico , Enfermedades de las Cabras/microbiología , Cabras , Mycobacterium avium subsp. paratuberculosis/clasificación , Mycobacterium avium subsp. paratuberculosis/genética , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Paratuberculosis/diagnóstico , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Ovinos , Enfermedades de las Ovejas/diagnóstico , Enfermedades de las Ovejas/microbiologíaRESUMEN
The present study aims to develop a method for rapid diagnosis of malaria using loop-mediated isothermal amplification (LAMP) combined with a lateral flow device (LFD). By adding the biotin-labeled and fluorescein amidite-labeled loop primers to the LAMP reaction solution, the end product can be visualized on a LFD. The entire procedure takes approximately 42 minutes to complete, LAMP assay exhibited high sensitivity, as the detection limit was 0.01 pg/µL for all five Plasmodium species. It was demonstrated that all Plasmodium knowlesi (N = 90) and Plasmodium vivax (N = 56) were positively amplified by LAMP-LFD assay, whereas healthy donor samples (N = 8) were negative. However, not all mixed infections were positive, and other infected nonmalaria samples were negative. Loop-mediated isothermal amplification-LFD represents a robust approach with potential suitability for use in resource-constrained laboratories. We believe that LAMP-LFD has a potential to be developed as point-of-care diagnostic tool in future.