Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Analyst ; 141(13): 4035-43, 2016 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-27124266

RESUMEN

A number of reports have been made in recent times on label-free detection of nucleic acid sequences. However, most of these studies deal with ensemble measurements, therefore lacking in molecular level resolution. These assays have usually employed ssDNA sensor probes, and often suffered from problems of irreproducibility and poor sequence-selectivity. Herein, the applicability of surface-anchored single stranded locked nucleic acid (ssLNA) probes has been assessed in the detection of target DNA sequences, as an alternative to the DNA-based assay. Importantly, the effectiveness of the LNA-based assay in identifying different types of single nucleobase mismatches has been tested. Since the duplex melting temperature is an indicator of duplex stability, the ensemble on-surface Tm values of the surface-confined LNA-DNA duplexes have been compared to the duplex unbinding force values obtained from atomic force spectroscopy (AFS) experiments. A common mismatch discrimination pattern elicited by both the ensemble and the molecular level AFS approach could be identified. Apart from quantitative delineation of the different types of mismatches, the label-free AFS analysis confirms different degrees of efficiency of the purine and pyrimidine bases, present on the LNA backbone, in discriminating different nucleobase mismatch types. Importantly, the LNA-based AFS analysis can distinguish between the disease-relevant gene fragments, e.g., multidrug-resistant Mycobacterium tuberculosis (MTB) mutation, and the wild type. Since LNA probes are nuclease-resistant, these findings could potentially pave way to diagnostic applications of the LNA-based AFS assay.


Asunto(s)
ADN de Cadena Simple/química , ADN/análisis , Sondas de Ácido Nucleico/química , Proteínas Bacterianas/genética , ARN Polimerasas Dirigidas por ADN/genética , Mycobacterium tuberculosis/genética , Espectrofotometría Atómica , Tuberculosis Resistente a Múltiples Medicamentos/microbiología
2.
Biochimie ; 213: 168-175, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37211256

RESUMEN

High mobility group B1 (HMGB1) is an architectural protein that recognizes the DNA damage sites formed by the platinum anticancer drugs. However, the impact of HMGB1 binding on the structural alterations of the platinum drug-treated single dsDNA molecules has remained largely unknown. Herein, the structural alterations induced by the platinum drugs, the mononuclear cisplatin and it's analog the trinuclear BBR3464, have been probed in presence of HMGB1, by atomic force microscopy (AFM) and AFM-based force spectroscopy. It is observed that the drug-induced DNA loop formation enhanced upon HMGB1 binding, most likely as a result of HMGB1-induced increase in DNA conformational flexibility that allowed the drug-binding sites to come close and form double adducts, thereby resulting in enhanced loop formation via inter-helix cross-linking. Since HMGB1 enhances DNA flexibility, the near-reversible structural transitions as observed in the force-extension curves (for 1 h drug treatment), generally occurred at lower forces in presence of HMGB1. The DNA structural integrity was largely lost after 24 h drug treatment as no reversible transition could be observed. The Young's modulus of the dsDNA molecules, as estimated from the force-extension analysis, increased upon drug treatment, due to formation of the drug-induced covalent cross-links and consequent reduction in DNA flexibility. The Young's modulus increased further in presence of HMGB1 due to HMGB1-induced enhancement in DNA flexibility that could ease formation of the drug-induced covalent cross-links. To our knowledge, this is the first report that shows an increase in the stiffness of the platinum drug-treated DNA molecules in presence of HMGB1.


Asunto(s)
Antineoplásicos , Proteína HMGB1 , Platino (Metal)/farmacología , Proteína HMGB1/química , Proteína HMGB1/metabolismo , ADN/química , Cisplatino/farmacología , Antineoplásicos/farmacología , Antineoplásicos/química , Conformación de Ácido Nucleico
3.
ACS Omega ; 7(18): 15296-15307, 2022 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-35571783

RESUMEN

The strategies for nucleic acid sensing based on nucleic acid hybridization between the target sequence and the capture probe sequence are considered to be largely successful as far as detection of a specific target of known sequence is concerned. However, when compared with other complementary methods, like direct sequencing, a number of results are still found to be either "false positives" or "false negatives". This suggests that modifications in these strategies are necessary to make them more accurate. In this minireview, we propose that one way toward improvement could be replacement of the DNA capture probes with the xeno nucleic acid or XNA capture probes. This is because the XNAs, especially the locked nucleic acid, the peptide nucleic acid, and the morpholino, have shown better single nucleobase mismatch discrimination capacity than the DNA capture probes, indicating their capacity for more precise detection of nucleic acid sequences, which is beneficial for detection of gene stretches having point mutations. Keeping the current trend in mind, this minireview will include the recent developments in nanoscale, fluorescent label-free applications, and present the cases where the XNA probes show clear advantages over the DNA probes.

4.
RSC Adv ; 12(15): 9263-9274, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35424880

RESUMEN

Nucleic acid-based biosensors, where the capture probe is a nucleic acid, e.g., DNA or its synthetic analogue xeno nucleic acid (XNA), offer interesting ways of eliciting clinically relevant information from hybridization/dehybridization signals. In this respect, the application of XNA probes is attractive since the drawbacks of DNA probes might be overcome. Within the XNA probe repertoire, peptide nucleic acid (PNA) and morpholino (MO) are promising since their backbones are non-ionic. Therefore, in the absence of electrostatic charge repulsion between the capture probe and the target nucleic acid, a stable duplex can be formed. In addition, these are nuclease-resistant probes. Herein, we have tested the molecularly resolved nucleic acid sensing capacity of PNA and MO capture probes using a fluorescent label-free single molecule force spectroscopy approach. As far as single nucleobase mismatch discrimination is concerned, both PNA and MO performed better than DNA, while the performance of the MO probe was the best. We propose that the conformationally more rigid backbone of MO, compared to the conformationally flexible PNA, is an advantage for MO, since the probe orientation can be made more upright on the surface and therefore MO can be more effectively accessed by the target sequences. The performance of the XNA probes has been compared to that of the DNA probe, using fixed nucleobase sequences, so that the effect of backbone variation could be investigated. To our knowledge, this is the first report on molecularly resolved nucleic acid sensing by non-ionic capture probes, here, MO and PNA.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA