Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
2.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
JAMA ; 319(13): 1331-1340, 2018 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-29525821

RESUMEN

Importance: The effects of loading doses of statins on clinical outcomes in patients with acute coronary syndrome (ACS) and planned invasive management remain uncertain. Objective: To determine if periprocedural loading doses of atorvastatin decrease 30-day major adverse cardiovascular events (MACE) in patients with ACS and planned invasive management. Design, Setting, and Participants: Multicenter, double-blind, placebo-controlled, randomized clinical trial conducted at 53 sites in Brazil among 4191 patients with ACS evaluated with coronary angiography to proceed with a percutaneous coronary intervention (PCI) if anatomically feasible. Enrollment occurred between April 18, 2012, and October 6, 2017. Final follow-up for 30-day outcomes was on November 6, 2017. Interventions: Patients were randomized to receive 2 loading doses of 80 mg of atorvastatin (n = 2087) or matching placebo (n = 2104) before and 24 hours after a planned PCI. All patients received 40 mg of atorvastatin for 30 days starting 24 hours after the second dose of study medication. Main Outcomes and Measures: The primary outcome was MACE, defined as a composite of all-cause mortality, myocardial infarction, stroke, and unplanned coronary revascularization through 30 days. Results: Among the 4191 patients (mean age, 61.8 [SD, 11.5] years; 1085 women [25.9%]) enrolled, 4163 (99.3%) completed 30-day follow-up. A total of 2710 (64.7%) underwent PCI, 333 (8%) underwent coronary artery bypass graft surgery, and 1144 (27.3%) had exclusively medical management. At 30 days, 130 patients in the atorvastatin group (6.2%) and 149 in the placebo group (7.1%) had a MACE (absolute difference, 0.85% [95% CI, -0.70% to 2.41%]; hazard ratio, 0.88; 95% CI, 0.69-1.11; P = .27). No cases of hepatic failure were reported; 3 cases of rhabdomyolysis were reported in the placebo group (0.1%) and 0 in the atorvastatin group. Conclusions and Relevance: Among patients with ACS and planned invasive management with PCI, periprocedural loading doses of atorvastatin did not reduce the rate of MACE at 30 days. These findings do not support the routine use of loading doses of atorvastatin among unselected patients with ACS and intended invasive management. Trial Registration: clinicaltrials.gov Identifier: NCT01448642.


Asunto(s)
Síndrome Coronario Agudo/tratamiento farmacológico , Atorvastatina/administración & dosificación , Enfermedades Cardiovasculares/prevención & control , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/terapia , Anciano , Atorvastatina/efectos adversos , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/mortalidad , Método Doble Ciego , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/efectos adversos , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Infarto del Miocardio con Elevación del ST/terapia
4.
Circulation ; 131(18): 1566-74, 2015 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-25753535

RESUMEN

BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.


Asunto(s)
Endocarditis Bacteriana/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Infecciones Relacionadas con Prótesis/etiología , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Endocarditis Bacteriana/mortalidad , Endocarditis Bacteriana/cirugía , Enterococcus , Contaminación de Equipos , Femenino , Infecciones por Bacterias Grampositivas/etiología , Infecciones por Bacterias Grampositivas/cirugía , Insuficiencia Cardíaca/etiología , Mortalidad Hospitalaria , Humanos , Incidencia , Intubación Intratraqueal/efectos adversos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Modelos de Riesgos Proporcionales , Infecciones Relacionadas con Prótesis/mortalidad , Infecciones Relacionadas con Prótesis/cirugía , Sistema de Registros , Estudios Retrospectivos , Riesgo , Infecciones Estafilocócicas/etiología , Infecciones Estafilocócicas/cirugía , Resultado del Tratamiento
5.
Artículo en Inglés | MEDLINE | ID: mdl-39362818

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established treatment for symptomatic patients with aortic stenosis. Yet, the impact of sex differences and public vs. private procedural setting on TAVI outcomes remain uncertain. METHODS: The RIBAC-NT (Brazilian Registry for Evaluation of Transcatheter Aortic Valve Replacement Outcomes) dataset included 3194 TAVI patients from 2009 to 2021. This retrospective analysis explored disparities in baseline characteristics, procedural and in-hospital outcomes stratifying patients by sex and procedural setting. Temporal trends were also investigated. RESULTS: We included 1551 (49 %) female and 1643 (51 %) male patients. Women were older (83 [78-87] vs. 81 [75-85] years; p < 0.01) but had a lower prevalence of diabetes mellitus (30.2 % vs. 36.3 %, p < 0.01) and coronary artery disease (39.0 % vs. 52.2 %, p < 0.01). However, women had a 3-fold higher higher risk of life-threatening bleeding (6.1 % vs. 2.4 %, p < 0.01). Women presented higher procedural and in-hospital mortality rates (4.4 % vs. 2.5 % and 7.7 % vs. 4.5 %, all p < 0.01, respectively). Although public hospitals presented ~2-fold higher procedural mortality rate compared with private settings (5.0 % vs. 2.7 %, p < 0.01), after multivariable analysis procedural setting was not independently associated with in-hospital mortality. CONCLUSIONS: Women had higher procedural and in-hospital mortality rates after TAVI as compared with men, while facing higher life-threatening bleeding and adverse events rates. Although public hospitals exhibited higher mortality rates than private centers, procedural setting was not independently associated with in-hospital mortality.

6.
JACC Case Rep ; 10: 101762, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36974043

RESUMEN

An 89-year-old woman with severe aortic regurgitation and an aneurysmal interventricular membranous septum extending into the aortic annulus underwent successful transcatheter aortic valve replacement. A challenging case because of the risk of valve mispositioning complications attributed to the co-occurrence of pure aortic regurgitation (very low calcium burden) with an aneurysmal interventricular membranous septum. (Level of Difficulty: Intermediate.).

7.
Arq Bras Cardiol ; 120(4): e20210462, 2023.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37132671

RESUMEN

BACKGROUND: Major advances have been seen in techniques and devices for performing percutaneous coronary interventions (PCIs) for chronic total occlusions (CTOs), but there are limited real-world practice data from developing countries. OBJECTIVES: To report clinical and angiographic characteristics, procedural aspects, and clinical outcomes of CTO PCI performed at dedicated centers in Brazil. METHODS: Included patients underwent CTO PCI at centers participating in the LATAM CTO Registry, a Latin American multicenter registry dedicated to prospective collection of these data. Inclusion criteria were procedures performed in Brazil, age 18 years or over, and presence of CTO with PCI attempt. CTO was defined as a 100% lesion in an epicardial coronary artery, known or estimated to have lasted at least 3 months. RESULTS: Data on 1196 CTO PCIs were included. Procedures were performed primarily for angina control (85%) and/or treatment of moderate/severe ischemia (24%). Technical success rate was 84%, being achieved with antegrade wire approaches in 81% of procedures, antegrade dissection and re-entry in 9%, and retrograde approaches in 10%. In-hospital adverse cardiovascular events occurred in 2.3% of cases, with a mortality rate of 0.75%. CONCLUSIONS: CTOs can be treated effectively in Brazil by using PCI, with low complication rates. The scientific and technological development observed in this area in the past decade is reflected in the clinical practice of dedicated Brazilian centers.


FUNDAMENTO: Tem sido observado um grande avanço nas técnicas e nos dispositivos para a realização de intervenções coronárias percutâneas (ICP) em oclusões totais coronarianas crônicas (OTC), mas existem poucos dados da prática do mundo real em países em desenvolvimento. OBJETIVOS: Relatar as características clínicas e angiográficas, os aspectos dos procedimentos e os resultados clínicos da ICP de OTC em centros dedicados a esse procedimento no Brasil. MÉTODOS: Os pacientes incluídos foram submetidos à ICP de OTC em centros participantes do LATAM CTO Registry, um registro multicêntrico latino-americano dedicado à coleta prospectiva desses dados. Os critérios de inclusão foram procedimentos realizados no Brasil, idade acima de 18 anos e presença de OTC com tentativa de ICP. A definição de OTC foi lesão de 100% em uma artéria coronária epicárdica, conhecida ou estimada como tendo pelo menos 3 meses de evolução. RESULTADOS: Foram incluídos dados de 1.196 ICPs de OTC. Os procedimentos foram realizados principalmente para controle da angina (85%) e/ou tratamento de uma grande área isquêmica (24%). A taxa de sucesso técnico foi de 84% e foi alcançada com técnicas de fios anterógrados em 81%, dissecção/reentrada anterógrada em 9% e retrógrada em 10% dos procedimentos. Os eventos cardiovasculares adversos intra-hospitalares ocorreram em 2,3% dos casos, sendo a mortalidade de 0,75%. CONCLUSÕES: As OTC podem ser tratadas no Brasil por intervenção coronária percutânea de forma efetiva e com baixas taxas de complicações. O desenvolvimento científico e tecnológico observado nessa área na última década reflete-se na prática clínica de centros brasileiros dedicados a essa técnica.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Adolescente , Brasil , Oclusión Coronaria/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Enfermedad Crónica , Sistema de Registros
8.
Am J Cardiol ; 172: 90-97, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35387738

RESUMEN

Scarce data exist on mitral valve (MV) infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This multicenter study included a total of 579 patients with a diagnosis of definite IE after TAVI from the IE after TAVI International Registry and aimed to evaluate the incidence, characteristics, management, and outcomes of MV-IE after TAVI. A total of 86 patients (14.9%) had MV-IE. These patients were compared with 284 patients (49.1%) with involvement of the transcatheter heart valve (THV) only. Two factors were found to be associated with MV-IE: the use of self-expanding valves (adjusted odds ratio 2.49, 95% confidence interval [CI] 1.23 to 5.07, p = 0.012), and the presence of an aortic regurgitation ≥2 at discharge (adjusted odds ratio 3.33; 95% CI 1.43 to 7.73, p <0.01). There were no differences in IE timing and causative microorganisms between groups, but surgical management was significantly lower in patients with MV-IE (6.0%, vs 21.6% in patients with THV-IE, p = 0.001). All-cause mortality rates at 2-year follow-up were high and similar between patients with MV-IE (51.4%, 95% CI 39.8 to 64.1) and patients with THV-IE (51.5%, 95% CI 45.4 to 58.0) (log-rank p = 0.295). The factors independently associated with increased mortality risk in patients with MV-IE were the occurrence of heart failure (adjusted p <0.001) and septic shock (adjusted p <0.01) during the index hospitalization. One of 6 IE episodes after TAVI is localized on the MV. The implantation of a self-expanding THV and the presence of an aortic regurgitation ≥2 at discharge were associated with MV-IE. Patients with MV-IE were rarely operated on and had a poor prognosis at 2-year follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Endocarditis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Catéteres/efectos adversos , Endocarditis/epidemiología , Endocarditis/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Can J Cardiol ; 38(1): 102-112, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34688853

RESUMEN

BACKGROUND: Staphylococcus aureus (SA) has been extensively studied as causative microorganism of surgical prosthetic-valve infective endocarditis (IE). However, scarce evidence exists on SA IE after transcatheter aortic valve replacement (TAVR). METHODS: Data were obtained from the Infectious Endocarditis After TAVR International Registry, including patients with definite IE after TAVR from 59 centres in 11 countries. Patients were divided into 2 groups according to microbiologic etiology: non-SA IE vs SA IE. RESULTS: SA IE was identified in 141 patients out of 573 (24.6%), methicillin-sensitive SA in most cases (115/141, 81.6%). Self-expanding valves were more common than balloon-expandable valves in patients presenting with early SA IE. Major bleeding and sepsis complicating TAVR, neurologic symptoms or systemic embolism at admission, and IE with cardiac device involvement (other than the TAVR prosthesis) were associated with SA IE (P < 0.05 for all). Among patients with IE after TAVR, the likelihood of SA IE increased from 19% in the absence of those risk factors to 84.6% if ≥ 3 risk factors were present. In-hospital (47.8% vs 26.9%; P < 0.001) and 2-year (71.5% vs 49.6%; P < 0.001) mortality rates were higher among patients with SA IE vs non-SA IE. Surgery at the time of index SA IE episode was associated with lower mortality at follow-up compared with medical therapy alone (adjusted hazard ratio 0.46, 95% CI 0.22-0.96; P = 0.038). CONCLUSIONS: SA IE represented approximately 25% of IE cases after TAVR and was associated with very high in-hospital and late mortality. The presence of some features determined a higher likelihood of SA IE and could help to orientate early antibiotic regimen selection. Surgery at index SA IE was associated with improved outcomes, and its role should be evaluated in future studies.


Asunto(s)
Endocarditis Bacteriana/epidemiología , Prótesis Valvulares Cardíacas/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Sistema de Registros , Infecciones Estafilocócicas/epidemiología , Staphylococcus aureus/aislamiento & purificación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Endocarditis Bacteriana/microbiología , Femenino , Estudios de Seguimiento , Salud Global , Prótesis Valvulares Cardíacas/microbiología , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Masculino , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos , Factores de Riesgo , Infecciones Estafilocócicas/diagnóstico , Infecciones Estafilocócicas/microbiología , Tasa de Supervivencia/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
10.
J Am Coll Cardiol ; 79(8): 772-785, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35210032

RESUMEN

BACKGROUND: The optimal treatment of patients developing infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is uncertain. OBJECTIVES: The goal of this study was to investigate the clinical characteristics and outcomes of patients with TAVI-IE treated with cardiac surgery and antibiotics (IE-CS) compared with patients treated with antibiotics alone (IE-AB). METHODS: Crude and inverse probability of treatment weighting analyses were applied for the treatment effect of cardiac surgery vs medical therapy on 1-year all-cause mortality in patients with definite TAVI-IE. The study used data from the Infectious Endocarditis after TAVI International Registry. RESULTS: Among 584 patients, 111 patients (19%) were treated with IE-CS and 473 patients (81%) with IE-AB. Compared with IE-AB, IE-CS was not associated with a lower in-hospital mortality (HRunadj: 0.85; 95% CI: 0.58-1.25) and 1-year all-cause mortality (HRunadj: 0.88; 95% CI: 0.64-1.22) in the crude cohort. After adjusting for selection and immortal time bias, IE-CS compared with IE-AB was also not associated with lower mortality rates for in-hospital mortality (HRadj: 0.92; 95% CI: 0.80-1.05) and 1-year all-cause mortality (HRadj: 0.95; 95% CI: 0.84-1.07). Results remained similar when patients with and without TAVI prosthesis involvement were analyzed separately. Predictors for in-hospital and 1-year all-cause mortality included logistic EuroSCORE I, Staphylococcus aureus, acute renal failure, persistent bacteremia, and septic shock. CONCLUSIONS: In this registry, the majority of patients with TAVI-IE were treated with antibiotics alone. Cardiac surgery was not associated with an improved all-cause in-hospital or 1-year mortality. The high mortality of patients with TAVI-IE was strongly linked to patients' characteristics, pathogen, and IE-related complications.


Asunto(s)
Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis Bacteriana/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Procedimientos Quirúrgicos Cardíacos , Terapia Combinada , Endocarditis Bacteriana/etiología , Femenino , Humanos , Masculino , Infecciones Relacionadas con Prótesis/etiología , Infecciones Estafilocócicas/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA