Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-30249698

RESUMEN

One of the critical elements of antimicrobial stewardship programs is the ability to measure the quality of antibiotic prescriptions. The aims of the present study were to evaluate the performance properties of a set of previously developed quality indicators (QIs) and to identify the potential room for improvement in antibiotic use in our setting. A monthly cross-sectional point prevalence survey was conducted in a 400-bed acute care teaching hospital, from June to November 2015. All adult patients treated for ≥24 hours with antibiotic therapy for a suspected hospital- or community-acquired bacterial infection were included. Performance scores (adherence, room for improvement, interobserver reliability, and applicability) were calculated for 8 QIs. A total of 362 patients were evaluated. Adherence to the whole set of QIs was accomplished for 14.1% of evaluable patients. The QIs with greater room for improvement were adequate request for blood cultures (60.6%), therapeutic drug monitoring (TDM) (59.1%), sequential antibiotic therapy within 72 hours (48.2%), and empirical antibiotic therapy according to local guidelines (30.4%). The percentage of patients receiving unnecessary antibiotic treatment in the absence of clinical or microbiological evidence of infection after 5 days was 12.2%. All indicators scored kappa values of ≥0.6, suggesting good interobserver reliability. Low applicability (6.1% of reviewed patients) was found only for the TDM QI. The QIs analyzed were found to be applicable, showed good interobserver reliability, and were useful tools to identify areas with potential room for improvement in antibiotic use.


Asunto(s)
Antibacterianos/uso terapéutico , Programas de Optimización del Uso de los Antimicrobianos , Infecciones Bacterianas/tratamiento farmacológico , Hospitales de Enseñanza , Indicadores de Calidad de la Atención de Salud/estadística & datos numéricos , Adulto , Infecciones Bacterianas/microbiología , Infecciones Bacterianas/patología , Cultivo de Sangre/estadística & datos numéricos , Infecciones Comunitarias Adquiridas , Estudios Transversales , Monitoreo de Drogas/métodos , Femenino , Humanos , Masculino , Guías de Práctica Clínica como Asunto , Uso Excesivo de Medicamentos Recetados/estadística & datos numéricos , España
2.
Clin Nucl Med ; 47(7): 618-624, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35605055

RESUMEN

BACKGROUND: Point of injection scatter (SPI) confounds breast cancer sentinel lymph node detection. Round flat lead shields (FLSs) incompletely reduce SPI, requiring repositioning. We designed lead shields that reduce SPI and acquisition time. METHODS: Two concave lead shields, a semioval lead shield (OLS) and a semispherical lead alloy shield (SLS), were created with a SICNOVA JCR 1000 3D printer to cover the point of injection (patent no. ES1219895U). Twenty breast cancer patients had anterior and anterior oblique imaging, 5 minutes and 2 hours after a single 111 MBq nanocolloid in 0.2 mL intratumoral or periareolar injection. Each acquisition was 2 minutes. Absolute and normalized background corrected scatter counts (CSCs) and scatter reduction percentage (%SR) related to the FLS were calculated. Repositionings were recorded. Differences between means of %SR (t test) and between means of CSC (analysis of variance) with Holm multiple comparison tests were determined. RESULTS: Mean %SR was 91.8% with OLS and 92% using SLS in early images (P = 0.91) and 87.2%SR in OLS and 88.5% in late images (P = 0.66). There were significant differences between CSC using FLS and OLS (P < 0.001) and between FLS and SLS (P < 0.001), but not between OLS and SLS (P = 0.17) in early images, with the same results observed in delayed studies (P < 0.001 in relation to FLS and P = 0.1 between both curved lead shields). Repositioning was required 14/20 times with FLS, 4/20 times with OLS, and 2/20 times with SLS. CONCLUSIONS: We designed 2 concave lead shields that significantly reduce the SPI and repositioning with sentinel lymph node lymphoscintigraphy.


Asunto(s)
Neoplasias de la Mama , Neoplasias de la Mama/patología , Femenino , Humanos , Ganglios Linfáticos/patología , Metástasis Linfática/patología , Cintigrafía , Radiofármacos , Biopsia del Ganglio Linfático Centinela/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA