Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pacing Clin Electrophysiol ; 40(10): 1129-1138, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28842918

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) is associated with reduction in arrhythmic mortality. However, at the time of generator replacement (GR) some patients had not experienced therapies and had a different clinical profile. Therefore, the risk-benefit ratio of ICD may have changed. Our aim was to determine the proportion of patients with ICD implanted in primary prevention that maintain guideline-derived indications at the time of GR and assess predictors of therapies in the postreplacement period. We evaluate the long-term benefit of ICD after GR in nonischemic cardiomyopathy (NICM) versus ischemic cardiomyopathy (ICM). METHODS: We included 141 patients undergoing GR from 11/2009 to 7/2015. Patients were divided into: G1 - guideline congruent indication for ICD at the time of GR (left ventricular ejection fraction [LVEF] ≤ 35% or appropriate therapies) and G2 - guideline incongruent indication (patients without appropriate therapies and LVEF >35%). We also compared ICD benefit between ICM and NICM patients. RESULTS: Maintenance of guideline-driven indications for ICD (G1) was present in 68% of patients and 32% had recovery of LVEF and no ICD therapies at the time of GR (G2). After GR, G2 patients showed a lower rate of appropriate therapies (3% vs 33%, P < 0.01). LVEF ≤ 35% was the only independent predictor of appropriate therapies (OR 12.0, P < 0.01). In multivariate analysis, etiology of heart failure did not predict the arrhythmic risk. CONCLUSION: At the time of GR, a significant proportion of patients no longer met guideline indications for ICD and their need for therapies is reduced. The etiology of heart failure did not predict freedom from therapies.


Asunto(s)
Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/terapia , Desfibriladores Implantables , Anciano , Arritmias Cardíacas/complicaciones , Cardiomiopatías/complicaciones , Remoción de Dispositivos , Femenino , Adhesión a Directriz , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
3.
Rev Port Cardiol (Engl Ed) ; 38(2): 117-124, 2019 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-30879895

RESUMEN

INTRODUCTION: Oral anticoagulants have proved to be highly effective in preventing atrial fibrillation (AF)-related strokes. The occurrence of stroke despite oral anticoagulation is unexpected and little is known about the mechanisms responsible. The aim of this study was to assess possible mechanisms for stroke occurrence, such as poor treatment adherence and inappropriate dosage, in patients chronically anticoagulated for AF. METHODS: We performed a prospective observational study of 60 consecutive patients with non-valvular AF, chronically medicated with an oral anticoagulant and admitted due to ischemic stroke. Treatment adherence was assessed through the Brief Medication Questionnaire (BMQ) and the Medição da Adesão ao Tratamento (MAT) scales. Patient characteristics, stroke etiology, and appropriacy of anticoagulant dosage were also assessed. RESULTS: Patients' mean age was 78.6±8.0 years, and 51.7% were male. Overall, the proportion of patients with good adherence to anticoagulants was 63.3%. Adherent patients were more frequently illiterate (26.3% vs. 4.5%, p=0.012). The proportion of patients under vitamin K antagonists (VKAs) with good treatment adherence was significantly higher than that of patients under novel oral anticoagulants (NOACs) (83.3% vs. 54.8%, respectively, for BMQ, p=0.035). However, 91.7% of patients under VKAs presented an admission INR <2. Subtherapeutic prescriptions were found in 43% of patients under NOACs. CONCLUSION: In the majority of patients, stroke occurrence despite chronic anticoagulation appears to be explained by subtherapeutic dosage, poor treatment adherence or non-cardioembolic etiology, and not by inefficacy of the anticoagulants.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/complicaciones , Isquemia Encefálica/etiología , Terapia Trombolítica/métodos , Administración Oral , Anciano , Fibrilación Atrial/tratamiento farmacológico , Coagulación Sanguínea , Isquemia Encefálica/sangre , Isquemia Encefálica/prevención & control , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Prospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X
4.
Int J Cardiovasc Imaging ; 33(3): 311-312, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27832420

RESUMEN

Strut disruption of bioresorbable vascular scaffold is a known potential concern, although uncommon when adequate lesion preparation is achieved and nominal size of the scaffold is respected. It is usually difficult to detect with angiography and/or intravascular ultrasound. Three-dimensional reconstructions of optical coherence tomography facilitates understanding of complex luminal anatomy and configuration of stent struts, providing evaluation of stent integrity immediately after deployment and therefore optimization of the complex revascularization procedure. The present article reports a case where this image modality enabled successful use of a drug-eluting stent inside a bioresorbable vascular scaffold to restore the luminal integrity, jeopardized by struts disruption. This case highlights the need to better characterize coronary atherosclerotic disease complexity before considering bioresorbable vascular scaffold implantation. Optical coherence tomography imaging could be a useful tool for accurate selection of the most suitable lesions for bioresorbable stents and to guide the revascularization process, so that in the event of stent fracture it may be detected and managed in a timely fashion.


Asunto(s)
Implantes Absorbibles , Angina Estable/terapia , Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Falla de Prótesis , Tomografía de Coherencia Óptica , Angina Estable/diagnóstico por imagen , Angina Estable/etiología , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Humanos , Masculino , Metales , Valor Predictivo de las Pruebas , Diseño de Prótesis , Retratamiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA