Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 27(Pt 2): 515-528, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32153293

RESUMEN

ID15A is a newly refurbished beamline at the ESRF devoted to operando and time-resolved diffraction and imaging, total scattering and diffraction computed tomography. The beamline is optimized for rapid alternation between the different techniques during a single operando experiment in order to collect complementary data on working systems. The high available energy (up to 120 keV) means that even bulky and highly absorbing systems may be studied. The beamline is equipped with optimized focusing optics and a photon-counting CdTe pixel detector, allowing for both unprecedented data quality at high energy and for very rapid triggered experiments. A large choice of imaging detectors and ancillary probes and sample environments is also available.

2.
J Synchrotron Radiat ; 16(Pt 4): 469-76, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19535859

RESUMEN

A multiple-analyser-crystal spectrometer for non-resonant inelastic X-ray scattering spectroscopy installed at beamline ID16 of the European Synchrotron Radiation Facility is presented. Nine analyser crystals with bending radii R = 1 m measure spectra for five different momentum transfer values simultaneously. Using a two-dimensional detector, the spectra given by all analysers can be treated individually. The spectrometer is based on a Rowland circle design with fixed Bragg angles of about 88 degrees . The energy resolution can be chosen between 30-2000 meV with typical incident-photon energies of 6-13 keV. The spectrometer is optimized for studies of valence and core electron excitations resolving both energy and momentum transfer.

3.
J Synchrotron Radiat ; 11(Pt 2): 132-41, 2004 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-14960777

RESUMEN

The performance of an indirectly cooled cryogenic silicon monochromator under heat loads up to 870 W has been studied. The investigation was performed over numerous parameters and included measurements of total flux, spectral density, rocking curves, angular beam profiles and crystal slope errors. An almost ideal monochromator performance was observed in the 270-570 W range of the heating power. At a heat load of approximately 400 W and under standard operation conditions, the crystal distortions did not exceed 1 micro rad. At the highest available heat load of 870 W, the crystal distortions were about 7 micro rad.


Asunto(s)
Análisis de Falla de Equipo , Congelación , Calor , Silicio , Sincrotrones/instrumentación , Transductores , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA