Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 35(3): 406-414, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38197476

RESUMEN

INTRODUCTION: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF. METHODS AND RESULTS: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF. First, high-density mapping (78% biatrial) with a multipolar mapping catheter was performed. In addition to pulmonary vein isolation (PVI), ablation of DISPERS was performed aiming at homogenizing, dissecting, isolating, or connecting DISPERS areas to nonconducting anatomical structures. Follow-up contained regular visits at our outpatient clinic at 1, 3, 6, and 12 months including 7-day Holter electrocardiograms. Patients were mainly suffering from long-standing persistent AF (mean AF duration 50.30 ± 54.28 months). Following PVI, ablation of left atrial and right atrial DISPERS areas led to AF cycle length prolongation (mean of 162.0 ± 16.6 to 202.2 ± 21.6 ms after) and AF termination to atrial tachycardia (AT) or sinus rhythm (SR) in 12 patients (24%). No stroke or pericardial effusion occurred; major groin complications (pseudoaneurysm n = 1, atrioventricular fistula n = 1) were detected in two patients. After a blanking period of 6 weeks, recurrence of any atrial arrhythmia was documented in 26 patients (52%). The majority of patients presented with organized AT (n = 15) while AF was present in n = 9 patients and AT/AF was observed in n = 2 patients. Twenty-two patients underwent reablation. During a mean follow-up of 363.14 ± 187.42 days and after an average of 1.46 ± 0.68 procedures, 82% of patients remained in stable SR. CONCLUSION: DISPERS-guided ablation using machine learning software (the Volta VX1 software) in addition to PVI in long-standing persistent AF ablation resulted in high long-term success rates regarding AF and AT elimination. Most arrhythmia recurrences were reentrant AT. After a total of 1.46 ± 0.68 procedures, freedom from AF/AT was 82%. Despite prolonged procedure times complication rates were low. Randomized studies are necessary to evaluate long-term efficacy of dispersion-guided ablation using AI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Inteligencia Artificial , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
2.
Heart Rhythm ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39019385

RESUMEN

BACKGROUND: Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique. OBJECTIVE: The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT). METHODS: All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force-sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner. RESULTS: Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation. CONCLUSION: Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA