Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38526489

RESUMEN

RATIONALE: Blood flow rate affects mixed venous oxygenation (SvO2) during venovenous extracorporeal membrane oxygenation (ECMO), with possible effects on the pulmonary circulation and the right heart function. OBJECTIVES: We aimed at describing the physiologic effects of different levels of SvO2 obtained by changing ECMO blood flow, in patients with severe ARDS receiving ECMO and controlled mechanical ventilation. METHODS: Low (SvO2 target 70-75%), intermediate (SvO2 target 75-80%) and high (SvO2 target > 80%) ECMO blood flows were applied for 30 minutes in random order in 20 patients. Mechanical ventilation settings were left unchanged. The hemodynamic and pulmonary effects were assessed with pulmonary artery catheter and electrical impedance tomography (EIT). MEASUREMENTS AND MAIN RESULTS: Cardiac output decreased from low to intermediate and to high blood flow/SvO2 (9.2 [6.2-10.9] vs 8.3 [5.9-9.8] vs 7.9 [6.5-9.1] L/min, p = 0.014), as well as mean pulmonary artery pressure (34 ± 6 vs 31 ± 6 vs 30 ± 5 mmHg, p < 0.001), and right ventricle stroke work index (14.2 ± 4.4 vs 12.2 ± 3.6 vs 11.4 ± 3.2 g*m/beat/m2, p = 0.002). Cardiac output was inversely correlated with mixed venous and arterial PO2 values (R2 = 0.257, p = 0.031 and R2 = 0.324, p = 0.05). Pulmonary artery pressure was correlated with decreasing mixed venous PO2 (R2 = 0.29, p <0.001) and with increasing cardiac output (R2 = 0.378 p < 0.007). Measures of ventilation/perfusion mismatch did not differ between the three steps. CONCLUSIONS: In severe ARDS patients, increased ECMO blood flow rate resulting in higher SvO2 decreases pulmonary artery pressure, cardiac output, and right heart workload. This article is open access and distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License 4.0 (http://creativecommons.org/licenses/by-nc-nd/4.0/).

2.
Am J Respir Crit Care Med ; 209(6): 670-682, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38127779

RESUMEN

Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.


Asunto(s)
Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Humanos , Impedancia Eléctrica , Tomografía Computarizada por Rayos X/métodos , Pulmón , Insuficiencia Respiratoria/diagnóstico por imagen , Insuficiencia Respiratoria/terapia , Tomografía/métodos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia
3.
Crit Care ; 28(1): 241, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39010228

RESUMEN

BACKGROUND: Assessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch. METHODS: We enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units ( V D ' /QSHUNT) was calculated as an index of more effective hypoxic pulmonary vasoconstriction. The ratio between perfusion to non-dependent regions and ventilation to dead space units (QND/ V DS ' ) was calculated as an index of hypocapnic pneumoconstriction. RESULTS: Our calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). Higher V D ' / Q SHUNT correlated with higher PaO2/FiO2 (r = 0.49, p = 0.025) and lower shunt fraction (ρ = - 0.59, p = 0.005). Higher Q ND / V DS ' correlated with lower PEEP (ρ = - 0.62, p = 0.003) and plateau pressure (ρ = - 0.59, p = 0.005). Lower values of both indexes were associated with less ventilator-free days (p = 0.05 and p = 0.03, respectively). CONCLUSIONS: Regional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.


Asunto(s)
Impedancia Eléctrica , Síndrome de Dificultad Respiratoria , Tomografía , Relación Ventilacion-Perfusión , Humanos , Femenino , Masculino , Persona de Mediana Edad , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Impedancia Eléctrica/uso terapéutico , Anciano , Relación Ventilacion-Perfusión/fisiología , Tomografía/métodos , Espacio Muerto Respiratorio/fisiología , Respiración Artificial/métodos , Adulto , Monitoreo Fisiológico/métodos , Gasto Cardíaco/fisiología
4.
Am J Respir Crit Care Med ; 208(1): 25-38, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37097986

RESUMEN

Rationale: Defining lung recruitability is needed for safe positive end-expiratory pressure (PEEP) selection in mechanically ventilated patients. However, there is no simple bedside method including both assessment of recruitability and risks of overdistension as well as personalized PEEP titration. Objectives: To describe the range of recruitability using electrical impedance tomography (EIT), effects of PEEP on recruitability, respiratory mechanics and gas exchange, and a method to select optimal EIT-based PEEP. Methods: This is the analysis of patients with coronavirus disease (COVID-19) from an ongoing multicenter prospective physiological study including patients with moderate-severe acute respiratory distress syndrome of different causes. EIT, ventilator data, hemodynamics, and arterial blood gases were obtained during PEEP titration maneuvers. EIT-based optimal PEEP was defined as the crossing point of the overdistension and collapse curves during a decremental PEEP trial. Recruitability was defined as the amount of modifiable collapse when increasing PEEP from 6 to 24 cm H2O (ΔCollapse24-6). Patients were classified as low, medium, or high recruiters on the basis of tertiles of ΔCollapse24-6. Measurements and Main Results: In 108 patients with COVID-19, recruitability varied from 0.3% to 66.9% and was unrelated to acute respiratory distress syndrome severity. Median EIT-based PEEP differed between groups: 10 versus 13.5 versus 15.5 cm H2O for low versus medium versus high recruitability (P < 0.05). This approach assigned a different PEEP level from the highest compliance approach in 81% of patients. The protocol was well tolerated; in four patients, the PEEP level did not reach 24 cm H2O because of hemodynamic instability. Conclusions: Recruitability varies widely among patients with COVID-19. EIT allows personalizing PEEP setting as a compromise between recruitability and overdistension. Clinical trial registered with www.clinicaltrials.gov (NCT04460859).


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Humanos , Impedancia Eléctrica , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Tomografía Computarizada por Rayos X/métodos , Tomografía/métodos
5.
Crit Care ; 27(1): 145, 2023 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-37072854

RESUMEN

BACKGROUND: Optimal noninvasive respiratory support for patients with hypoxemic respiratory failure should minimize work of breathing without increasing the transpulmonary pressure. Recently, an asymmetrical high flow nasal cannula (HFNC) interface (Duet, Fisher & Paykel Healthcare Ltd), in which the caliber of each nasal prong is different, was approved for clinical use. This system might reduce work of breathing by lowering minute ventilation and improving respiratory mechanics. METHODS: We enrolled 10 patients ≥ 18 years of age who were admitted to the Ospedale Maggiore Policlinico ICU in Milan, Italy, and had a PaO2/FiO2 < 300 mmHg during HFNC support with a conventional cannula. We investigated whether the asymmetrical interface, compared to a conventional high flow nasal cannula, reduces minute ventilation and work of breathing. Each patient underwent support with the asymmetrical interface and the conventional interface, applied in a randomized sequence. Each interface was provided at a flow rate of 40 l/min followed by 60 l/min. Patients were continuously monitored with esophageal manometry and electrical impedance tomography. RESULTS: Application of the asymmetrical interface resulted in a -13.5 [-19.4 to (-4.5)] % change in minute ventilation at a flow rate of 40 l/min, p = 0.006 and a -19.6 [-28.0 to (-7.5)] % change at 60 l/min, p = 0.002, that occurred despite no change in PaCO2 (35 [33-42] versus 35 [33-43] mmHg at 40 l/min and 35 [32-41] versus 36 [32-43] mmHg at 60 l/min). Correspondingly, the asymmetrical interface lowered the inspiratory esophageal pressure-time product from 163 [118-210] to 140 [84-159] (cmH2O*s)/min at a flow rate of 40 l/min, p = 0.02 and from 142 [123-178] to 117 [90-137] (cmH2O*s)/min at a flow rate of 60 l/min, p = 0.04. The asymmetrical cannula did not have any impact on oxygenation, the dorsal fraction of ventilation, dynamic lung compliance, or end-expiratory lung impedance, suggesting no major effect on PEEP, lung mechanics, or alveolar recruitment. CONCLUSIONS: An asymmetrical HFNC interface reduces minute ventilation and work of breathing in patients with mild-to-moderate hypoxemic respiratory failure supported with a conventional interface. This appears to be primarily driven by increased ventilatory efficiency due to enhanced CO2 clearance from the upper airway.


Asunto(s)
Ventilación no Invasiva , Insuficiencia Respiratoria , Humanos , Cánula , Ventilación no Invasiva/métodos , Insuficiencia Respiratoria/terapia , Pulmón , Mecánica Respiratoria , Terapia por Inhalación de Oxígeno
6.
Crit Care ; 27(1): 78, 2023 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-36855198

RESUMEN

BACKGROUND: During high-flow nasal cannula (HFNC) therapy, flow plays a crucial role in the physiological effects. However, there is no consensus on the initial flow settings and subsequent titration. Thus, we aimed to systematically synthesize the effects of flows during HFNC treatment. METHODS: In this systematic review, two investigators independently searched PubMed, Embase, Web of Science, Scopus, and Cochrane for in vitro and in vivo studies investigating the effects of flows in HFNC treatment published in English before July 10, 2022. We excluded studies that investigated the pediatric population (< 18 years) or used only one flow. Two investigators independently extracted the data and assessed the risk of bias. The study protocol was prospectively registered with PROSPERO, CRD42022345419. RESULTS: In total, 32,543 studies were identified, and 44 were included. In vitro studies evaluated the effects of flow settings on the fraction of inspired oxygen (FIO2), positive end-expiratory pressure, and carbon dioxide (CO2) washout. These effects are flow-dependent and are maximized when the flow exceeds the patient peak inspiratory flow, which varies between patients and disease conditions. In vivo studies report that higher flows result in improved oxygenation and dead space washout and can reduce work of breathing. Higher flows also lead to alveolar overdistention in non-dependent lung regions and patient discomfort. The impact of flows on different patients is largely heterogeneous. INTERPRETATION: Individualizing flow settings during HFNC treatment is necessary, and titrating flow based on clinical findings like oxygenation, respiratory rates, ROX index, and patient comfort is a pragmatic way forward.


Asunto(s)
Cánula , Dióxido de Carbono , Niño , Humanos , Adulto , Administración Intranasal , Consenso , Oxígeno
7.
Crit Care ; 27(1): 138, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041553

RESUMEN

BACKGROUND: There is very limited evidence identifying factors that increase respiratory drive in hypoxemic intubated patients. Most physiological determinants of respiratory drive cannot be directly assessed at the bedside (e.g., neural inputs from chemo- or mechano-receptors), but clinical risk factors commonly measured in intubated patients could be correlated with increased drive. We aimed to identify clinical risk factors independently associated with increased respiratory drive in intubated hypoxemic patients. METHODS: We analyzed the physiological dataset from a multicenter trial on intubated hypoxemic patients on pressure support (PS). Patients with simultaneous assessment of the inspiratory drop in airway pressure at 0.1-s during an occlusion (P0.1) and risk factors for increased respiratory drive on day 1 were included. We evaluated the independent correlation of the following clinical risk factors for increased drive with P0.1: severity of lung injury (unilateral vs. bilateral pulmonary infiltrates, PaO2/FiO2, ventilatory ratio); arterial blood gases (PaO2, PaCO2 and pHa); sedation (RASS score and drug type); SOFA score; arterial lactate; ventilation settings (PEEP, level of PS, addition of sigh breaths). RESULTS: Two-hundred seventeen patients were included. Clinical risk factors independently correlated with higher P0.1 were bilateral infiltrates (increase ratio [IR] 1.233, 95%CI 1.047-1.451, p = 0.012); lower PaO2/FiO2 (IR 0.998, 95%CI 0.997-0.999, p = 0.004); higher ventilatory ratio (IR 1.538, 95%CI 1.267-1.867, p < 0.001); lower pHa (IR 0.104, 95%CI 0.024-0.464, p = 0.003). Higher PEEP was correlated with lower P0.1 (IR 0.951, 95%CI 0.921-0.982, p = 0.002), while sedation depth and drugs were not associated with P0.1. CONCLUSIONS: Independent clinical risk factors for higher respiratory drive in intubated hypoxemic patients include the extent of lung edema and of ventilation-perfusion mismatch, lower pHa, and lower PEEP, while sedation strategy does not affect drive. These data underline the multifactorial nature of increased respiratory drive.


Asunto(s)
Respiración con Presión Positiva , Respiración Artificial , Humanos , Respiración con Presión Positiva/efectos adversos , Respiración , Pulmón , Factores de Riesgo
8.
Eur Respir J ; 59(3)2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34413155

RESUMEN

BACKGROUND: Although small randomised controlled trials (RCTs) and observational studies have examined helmet noninvasive ventilation (NIV), uncertainty remains regarding its role. We conducted a systematic review and meta-analysis to examine the effect of helmet NIV compared to facemask NIV or high-flow nasal cannula (HFNC) in acute respiratory failure. METHODS: We searched multiple databases to identify RCTs and observational studies reporting on at least one of mortality, intubation, intensive care unit (ICU) length of stay, NIV duration, complications or comfort with NIV therapy. We assessed study risk of bias using the Cochrane Risk of Bias 2 tool for RCTs and the Ottawa-Newcastle Scale for observational studies, and rated certainty of pooled evidence using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) framework. RESULTS: We separately pooled data from 16 RCTs (n=949) and eight observational studies (n=396). Compared to facemask NIV, based on low certainty of evidence, helmet NIV may reduce mortality (relative risk 0.56, 95% CI 0.33-0.95) and intubation (relative risk 0.35, 95% CI 0.22-0.56) in both hypoxic and hypercapnic respiratory failure, but may have no effect on duration of NIV. There was an uncertain effect of helmet NIV on ICU length of stay and development of pressure sores. Data from observational studies were consistent with the foregoing findings but of lower certainty. Based on low and very low certainty data, helmet NIV may reduce intubation compared to HFNC, but its effect on mortality is uncertain. CONCLUSIONS: Compared to facemask NIV, helmet NIV may reduce mortality and intubation; however, the effect of helmet NIV compared to HFNC remains uncertain.


Asunto(s)
Ventilación no Invasiva , Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Cánula , Dispositivos de Protección de la Cabeza , Humanos , Terapia por Inhalación de Oxígeno , Insuficiencia Respiratoria/terapia
9.
Crit Care Med ; 50(5): 723-732, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35200194

RESUMEN

OBJECTIVES: Prone positioning allows to improve oxygenation and decrease mortality rate in COVID-19-associated acute respiratory distress syndrome (C-ARDS). However, the mechanisms leading to these effects are not fully understood. The aim of this study is to assess the physiologic effects of pronation by the means of CT scan and electrical impedance tomography (EIT). DESIGN: Experimental, physiologic study. SETTING: Patients were enrolled from October 2020 to March 2021 in an Italian dedicated COVID-19 ICU. PATIENTS: Twenty-one intubated patients with moderate or severe C-ARDS. INTERVENTIONS: First, patients were transported to the CT scan facility, and image acquisition was performed in prone, then supine position. Back to the ICU, gas exchange, respiratory mechanics, and ventilation and perfusion EIT-based analysis were provided toward the end of two 30 minutes steps (e.g., in supine, then prone position). MEASUREMENTS AND MAIN RESULTS: Prone position induced recruitment in the dorsal part of the lungs (12.5% ± 8.0%; p < 0.001 from baseline) and derecruitment in the ventral regions (-6.9% ± 5.2%; p < 0.001). These changes led to a global increase in recruitment (6.0% ± 6.7%; p < 0.001). Respiratory system compliance did not change with prone position (45 ± 15 vs 45 ± 18 mL/cm H2O in supine and prone position, respectively; p = 0.957) suggesting a decrease in atelectrauma. This hypothesis was supported by the decrease of a time-impedance curve concavity index designed as a surrogate for atelectrauma (1.41 ± 0.16 vs 1.30 ± 0.16; p = 0.001). Dead space measured by EIT was reduced in the ventral regions of the lungs, and the dead-space/shunt ratio decreased significantly (5.1 [2.3-23.4] vs 4.3 [0.7-6.8]; p = 0.035), showing an improvement in ventilation-perfusion matching. CONCLUSIONS: Several changes are associated with prone position in C-ARDS: increased lung recruitment, decreased atelectrauma, and improved ventilation-perfusion matching. These physiologic effects may be associated with more protective ventilation.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Impedancia Eléctrica , Humanos , Pulmón/diagnóstico por imagen , Perfusión , Respiración con Presión Positiva/métodos , Posición Prona , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Tomografía Computarizada por Rayos X
10.
Crit Care ; 26(1): 314, 2022 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-36258227

RESUMEN

Monitoring with electrical impedance tomography (EIT) during a decremental PEEP trial has been used to identify the PEEP that yields the optimal balance of pulmonary overdistension and collapse. This method is based on pixel-level changes in respiratory system compliance and depends on fixed or measured airway driving pressure. We developed a novel approach to quantify overdistension and collapse during pressure support ventilation (PSV) by integrating transpulmonary pressure and EIT monitoring and performed pilot tests in three hypoxemic patients. We report that our experimental approach is feasible and capable of identifying a PEEP that balances overdistension and collapse in intubated hypoxemic patients undergoing PSV.


Asunto(s)
Impedancia Eléctrica , Hipoxia , Respiración con Presión Positiva , Tomografía , Humanos , Impedancia Eléctrica/uso terapéutico , Hipoxia/diagnóstico por imagen , Hipoxia/terapia , Respiración con Presión Positiva/métodos , Tomografía/métodos
11.
Crit Care ; 26(1): 211, 2022 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-35818077

RESUMEN

PURPOSE: In the acute respiratory distress syndrome (ARDS), decreasing Ventilation-Perfusion [Formula: see text] mismatch might enhance lung protection. We investigated the regional effects of higher Positive End Expiratory Pressure (PEEP) on [Formula: see text] mismatch and their correlation with recruitability. We aimed to verify whether PEEP improves regional [Formula: see text] mismatch, and to study the underlying mechanisms. METHODS: In fifteen patients with moderate and severe ARDS, two PEEP levels (5 and 15 cmH2O) were applied in random order. [Formula: see text] mismatch was assessed by Electrical Impedance Tomography at each PEEP. Percentage of ventilation and perfusion reaching different ranges of [Formula: see text] ratios were analyzed in 3 gravitational lung regions, leading to precise assessment of their distribution throughout different [Formula: see text] mismatch compartments. Recruitability between the two PEEP levels was measured by the recruitment-to-inflation ratio method. RESULTS: In the non-dependent region, at higher PEEP, ventilation reaching the normal [Formula: see text] compartment (p = 0.018) increased, while it decreased in the high [Formula: see text] one (p = 0.023). In the middle region, at PEEP 15 cmH2O, ventilation and perfusion to the low [Formula: see text] compartment decreased (p = 0.006 and p = 0.011) and perfusion to normal [Formula: see text] increased (p = 0.003). In the dependent lung, the percentage of blood flowing through the non-ventilated compartment decreased (p = 0.041). Regional [Formula: see text] mismatch improvement was correlated to lung recruitability and changes in regional tidal volume. CONCLUSIONS: In patients with ARDS, higher PEEP optimizes the distribution of both ventilation (in the non-dependent areas) and perfusion (in the middle and dependent lung). Bedside measure of recruitability is associated with improved [Formula: see text] mismatch.


Asunto(s)
Síndrome de Dificultad Respiratoria , Humanos , Pulmón , Perfusión , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Fenómenos Fisiológicos Respiratorios
12.
Am J Respir Crit Care Med ; 204(8): 933-942, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34252009

RESUMEN

Rationale: Unilateral ligation of the pulmonary artery may induce lung injury through multiple mechanisms, which might be dampened by inhaled CO2. Objectives: This study aims to characterize bilateral lung injury owing to unilateral ligation of the pulmonary artery in healthy swine undergoing controlled mechanical ventilation and its prevention by 5% CO2 inhalation and to investigate relevant pathophysiological mechanisms. Methods: Sixteen healthy pigs were allocated to surgical ligation of the left pulmonary artery (ligation group), seven to surgical ligation of the left pulmonary artery and inhalation of 5% CO2 (ligation + FiCO2 5%), and six to no intervention (no ligation). Then, all animals received mechanical ventilation with Vt 10 ml/kg, positive end-expiratory pressure 5 cm H2O, respiratory rate 25 breaths/min, and FiO2 50% (±FiCO2 5%) for 48 hours or until development of severe lung injury. Measurements and Main Results: Histological, physiological, and quantitative computed tomography scan data were compared between groups to characterize lung injury. Electrical impedance tomography and immunohistochemistry analysis were performed in a subset of animals to explore mechanisms of injury. Animals from the ligation group developed bilateral lung injury as assessed by significantly higher histological score, larger increase in lung weight, poorer oxygenation, and worse respiratory mechanics compared with the ligation + FiCO2 5% group. In the ligation group, the right lung received a larger fraction of Vt and inflammation was more represented, whereas CO2 dampened both processes. Conclusions: Mechanical ventilation induces bilateral lung injury within 48 hours in healthy pigs undergoing left pulmonary artery ligation. Inhalation of 5% CO2 prevents injury, likely through decreased stress to the right lung and antiinflammatory effects.


Asunto(s)
Dióxido de Carbono/uso terapéutico , Modelos Animales de Enfermedad , Lesión Pulmonar/prevención & control , Sustancias Protectoras/uso terapéutico , Arteria Pulmonar/cirugía , Respiración Artificial/efectos adversos , Porcinos/cirugía , Administración por Inhalación , Animales , Femenino , Ligadura , Lesión Pulmonar/etiología , Lesión Pulmonar/fisiopatología , Lesión Pulmonar/terapia , Resultado del Tratamiento
13.
Anesthesiology ; 135(6): 1066-1075, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34644374

RESUMEN

BACKGROUND: Experimental and pilot clinical data suggest that spontaneously breathing patients with sepsis and septic shock may present increased respiratory drive and effort, even in the absence of pulmonary infection. The study hypothesis was that respiratory drive and effort may be increased in septic patients and correlated with extrapulmonary determinant and that high-flow nasal cannula may modulate drive and effort. METHODS: Twenty-five nonintubated patients with extrapulmonary sepsis or septic shock were enrolled. Each patient underwent three consecutive steps: low-flow oxygen at baseline, high-flow nasal cannula, and then low-flow oxygen again. Arterial blood gases, esophageal pressure, and electrical impedance tomography data were recorded toward the end of each step. Respiratory effort was measured as the negative swing of esophageal pressure (ΔPes); drive was quantified as the change in esophageal pressure during the first 500 ms from start of inspiration (P0.5). Dynamic lung compliance was calculated as the tidal volume measured by electrical impedance tomography, divided by ΔPes. The results are presented as medians [25th to 75th percentile]. RESULTS: Thirteen patients (52%) were in septic shock. The Sequential Organ Failure Assessment score was 5 [4 to 9]. During low-flow oxygen at baseline, respiratory drive and effort were elevated and significantly correlated with arterial lactate (r = 0.46, P = 0.034) and inversely with dynamic lung compliance (r = -0.735, P < 0.001). Noninvasive support by high-flow nasal cannula induced a significant decrease of respiratory drive (P0.5: 6.0 [4.4 to 9.0] vs. 4.3 [3.5 to 6.6] vs. 6.6 [4.9 to 10.7] cm H2O, P < 0.001) and effort (ΔPes: 8.0 [6.0 to 11.5] vs. 5.5 [4.5 to 8.0] vs. 7.5 [6.0 to 12.6] cm H2O, P < 0.001). Oxygenation and arterial carbon dioxide levels remained stable during all study phases. CONCLUSIONS: Patients with sepsis and septic shock of extrapulmonary origin present elevated respiratory drive and effort, which can be effectively reduced by high-flow nasal cannula.


Asunto(s)
Cánula , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Frecuencia Respiratoria/fisiología , Choque Séptico/fisiopatología , Choque Séptico/terapia , Anciano , Estudios de Cohortes , Impedancia Eléctrica/uso terapéutico , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Terapia por Inhalación de Oxígeno/instrumentación , Terapia por Inhalación de Oxígeno/métodos , Sepsis/fisiopatología , Sepsis/terapia
14.
Crit Care ; 25(1): 192, 2021 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-34082795

RESUMEN

BACKGROUND: In acute respiratory distress syndrome (ARDS), non-ventilated perfused regions coexist with non-perfused ventilated regions within lungs. The number of unmatched regions might reflect ARDS severity and affect the risk of ventilation-induced lung injury. Despite pathophysiological relevance, unmatched ventilation and perfusion are not routinely assessed at the bedside. The aims of this study were to quantify unmatched ventilation and perfusion at the bedside by electrical impedance tomography (EIT) investigating their association with mortality in patients with ARDS and to explore the effects of positive end-expiratory pressure (PEEP) on unmatched ventilation and perfusion in subgroups of patients with different ARDS severity based on PaO2/FiO2 and compliance. METHODS: Prospective observational study in 50 patients with mild (36%), moderate (46%), and severe (18%) ARDS under clinical ventilation settings. EIT was applied to measure the regional distribution of ventilation and perfusion using central venous bolus of saline 5% during end-inspiratory pause. We defined unmatched units as the percentage of only ventilated units plus the percentage of only perfused units. RESULTS: Percentage of unmatched units was significantly higher in non-survivors compared to survivors (32[27-47]% vs. 21[17-27]%, p < 0.001). Percentage of unmatched units was an independent predictor of mortality (OR 1.22, 95% CI 1.07-1.39, p = 0.004) with an area under the ROC curve of 0.88 (95% CI 0.79-0.97, p < 0.001). The percentage of ventilation to the ventral region of the lung was higher than the percentage of ventilation to the dorsal region (32 [27-38]% vs. 18 [13-21]%, p < 0.001), while the opposite was true for perfusion (28 [22-38]% vs. 36 [32-44]%, p < 0.001). Higher percentage of only perfused units was correlated with lower dorsal ventilation (r = - 0.486, p < 0.001) and with lower PaO2/FiO2 ratio (r = - 0.293, p = 0.039). CONCLUSIONS: EIT allows bedside assessment of unmatched ventilation and perfusion in mechanically ventilated patients with ARDS. Measurement of unmatched units could identify patients at higher risk of death and could guide personalized treatment.


Asunto(s)
Impedancia Eléctrica/uso terapéutico , Perfusión/normas , Pronóstico , Respiración Artificial/normas , Síndrome de Dificultad Respiratoria/complicaciones , Adulto , Anciano , Femenino , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Perfusión/métodos , Perfusión/estadística & datos numéricos , Estudios Prospectivos , Respiración Artificial/métodos , Respiración Artificial/estadística & datos numéricos , Síndrome de Dificultad Respiratoria/epidemiología , Síndrome de Dificultad Respiratoria/mortalidad , Puntuación Fisiológica Simplificada Aguda
15.
Br J Anaesth ; 127(1): 143-152, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33892948

RESUMEN

BACKGROUND: Bilateral lung transplantation results in pulmonary vagal denervation, which potentially alters respiratory drive, volume-feedback, and ventilatory pattern. We hypothesised that Neurally Adjusted Ventilatory Assist (NAVA) ventilation, which is driven by diaphragm electrical activity (EAdi), would reveal whether vagally mediated pulmonary-volume feedback is preserved in the early phases after bilateral lung transplantation. METHODS: We prospectively studied bilateral lung transplant recipients within 48 h of surgery. Subjects were ventilated with NAVA and randomised to receive 3 ventilatory modes (baseline NAVA, 50%, and 150% of baseline NAVA values) and 2 PEEP levels (6 and 12 cm H2O). We recorded airway pressure, flow, and EAdi. RESULTS: We studied 30 subjects (37% female; age: 37 (27-56) yr), of whom 19 (63%) had stable EAdi. The baseline NAVA level was 0.6 (0.2-1.0) cm H2O µV-1. Tripling NAVA level increased the ventilatory peak pressure over PEEP by 6.3 (1.8), 7.6 (2.4), and 8.7 (3.2) cm H2O, at 50%, 100%, and 150% of baseline NAVA level, respectively (P<0.001). EAdi peak decreased by 10.1 (9.0), 9.5 (9.4) and 8.8 µV (8.7) (P<0.001), accompanied by small increases in tidal volume, 8.3 (3.0), 8.7 (3.6), and 8.9 (3.3) ml kg-1 donor's predicted body weight at 50%, 100%, and 150% of baseline NAVA levels, respectively (P<0.001). Doubling PEEP did not affect tidal volume. CONCLUSIONS: NAVA ventilation was feasible in the majority of patients during the early postoperative period after bilateral lung transplantation. Despite surgical vagotomy distal to the bronchial anastomoses, bilateral lung transplant recipients maintained an unmodified respiratory pattern in response to variations in ventilatory assistance and PEEP. CLINICAL TRIAL REGISTRATION: NCT03367221.


Asunto(s)
Retroalimentación , Soporte Ventilatorio Interactivo/métodos , Trasplante de Pulmón/métodos , Respiración con Presión Positiva/métodos , Cuidados Posoperatorios/métodos , Volumen de Ventilación Pulmonar/fisiología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ventilación Pulmonar/fisiología , Desconexión del Ventilador/métodos
16.
Am J Respir Crit Care Med ; 201(7): 799-813, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31553891

RESUMEN

Rationale: Acidemia is a severe condition among critically ill patients. Despite lack of evidence, sodium bicarbonate is frequently used to correct pH; however, its administration is burdened by several side effects. We hypothesized that the reduction of plasma chloride concentration could be an alternative strategy to correct acidemia.Objectives: To evaluate feasibility, safety, and effectiveness of a novel strategy to correct acidemia through extracorporeal chloride removal by electrodialysis.Methods: Ten swine (six treated and four control animals) were sedated, mechanically ventilated and connected to an extracorporeal electrodialysis device capable of selectively removing chloride. In random order, an arterial pH of 7.15 was induced either through reduction of ventilation (respiratory acidosis) or through lactic acid infusion (metabolic acidosis). Acidosis was subsequently sustained for 12-14 hours. In treatment pigs, soon after reaching target acidemia, electrodialysis was started to restore pH.Measurements and Main Results: During respiratory acidosis, electrodialysis reduced plasma chloride concentration by 26 ± 5 mEq/L within 6 hours (final pH = 7.36 ± 0.04). Control animals exhibited incomplete and slower compensatory response to respiratory acidosis (final pH = 7.29 ± 0.03; P < 0.001). During metabolic acidosis, electrodialysis reduced plasma chloride concentration by 15 ± 3 mEq/L within 4 hours (final pH = 7.34 ± 0.07). No effective compensatory response occurred in control animals (final pH = 7.11 ± 0.08; P < 0.001). No complications occurred.Conclusions: We described the first in vivo application of an extracorporeal system targeted to correct severe acidemia by lowering plasma chloride concentration. Extracorporeal chloride removal by electrodialysis proved to be feasible, safe, and effective. Further studies are warranted to assess its performance in the presence of impaired respiratory and renal functions.


Asunto(s)
Acidosis/sangre , Acidosis/terapia , Cloruros/sangre , Diálisis Renal/métodos , Animales , Electricidad , Circulación Extracorporea , Porcinos
17.
Am J Respir Crit Care Med ; 202(7): 950-961, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32516052

RESUMEN

Mechanical ventilation can cause acute diaphragm atrophy and injury, and this is associated with poor clinical outcomes. Although the importance and impact of lung-protective ventilation is widely appreciated and well established, the concept of diaphragm-protective ventilation has recently emerged as a potential complementary therapeutic strategy. This Perspective, developed from discussions at a meeting of international experts convened by PLUG (the Pleural Pressure Working Group) of the European Society of Intensive Care Medicine, outlines a conceptual framework for an integrated lung- and diaphragm-protective approach to mechanical ventilation on the basis of growing evidence about mechanisms of injury. We propose targets for diaphragm protection based on respiratory effort and patient-ventilator synchrony. The potential for conflict between diaphragm protection and lung protection under certain conditions is discussed; we emphasize that when conflicts arise, lung protection must be prioritized over diaphragm protection. Monitoring respiratory effort is essential to concomitantly protect both the diaphragm and the lung during mechanical ventilation. To implement lung- and diaphragm-protective ventilation, new approaches to monitoring, to setting the ventilator, and to titrating sedation will be required. Adjunctive interventions, including extracorporeal life support techniques, phrenic nerve stimulation, and clinical decision-support systems, may also play an important role in selected patients in the future. Evaluating the clinical impact of this new paradigm will be challenging, owing to the complexity of the intervention. The concept of lung- and diaphragm-protective ventilation presents a new opportunity to potentially improve clinical outcomes for critically ill patients.


Asunto(s)
Diafragma/lesiones , Atrofia Muscular/prevención & control , Respiración Artificial/métodos , Lesión Pulmonar Inducida por Ventilación Mecánica/prevención & control , Consenso , Cuidados Críticos , Sistemas de Apoyo a Decisiones Clínicas , Terapia por Estimulación Eléctrica , Oxigenación por Membrana Extracorpórea , Humanos , Atrofia Muscular/etiología , Nervio Frénico , Respiración Artificial/efectos adversos , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología
18.
Crit Care Med ; 48(8): 1129-1134, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32697482

RESUMEN

OBJECTIVES: Severe cases of coronavirus disease 2019 develop the acute respiratory distress syndrome, requiring admission to the ICU. This study aimed to describe specific pathophysiological characteristics of acute respiratory distress syndrome from coronavirus disease 2019. DESIGN: Prospective crossover physiologic study. SETTING: ICU of a university-affiliated hospital from northern Italy dedicated to care of patients with confirmed diagnosis of coronavirus disease 2019. PATIENTS: Ten intubated patients with acute respiratory distress syndrome and confirmed diagnosis of coronavirus disease 2019. INTERVENTIONS: We performed a two-step positive end-expiratory pressure trial with change of 10 cm H2O in random order. MEASUREMENTS AND MAIN RESULTS: At each positive end-expiratory pressure level, we assessed arterial blood gases, respiratory mechanics, ventilation inhomogeneity, and potential for lung recruitment by electrical impedance tomography. Potential for lung recruitment was assessed by the recently described recruitment to inflation ratio. In a subgroup of seven paralyzed patients, we also measured ventilation-perfusion mismatch at lower positive end-expiratory pressure by electrical impedance tomography. At higher positive end-expiratory pressure, respiratory mechanics did not change significantly: compliance remained relatively high with low driving pressure. Oxygenation and ventilation inhomogeneity improved but arterial CO2 increased despite unchanged respiratory rate and tidal volume. The recruitment to inflation ratio presented median value higher than previously reported in acute respiratory distress syndrome patients but with large variability (median, 0.79 [0.53-1.08]; range, 0.16-1.40). The FIO2 needed to obtain viable oxygenation at lower positive end-expiratory pressure was significantly correlated with the recruitment to inflation ratio (r = 0.603; p = 0.05). The ventilation-perfusion mismatch was elevated (median, 34% [32-45%] of lung units) and, in six out of seven patients, ventilated nonperfused units represented a much larger proportion than perfused nonventilated ones. CONCLUSIONS: In patients with acute respiratory distress syndrome from coronavirus disease 2019, potential for lung recruitment presents large variability, while elevated dead space fraction may be a specific pathophysiological trait. These findings may guide selection of personalized mechanical ventilation settings.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Adulto , Anciano , Anciano de 80 o más Años , Análisis de los Gases de la Sangre , COVID-19 , Estudios Cruzados , Femenino , Hospitales Universitarios , Humanos , Italia , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Pandemias , Estudios Prospectivos , Síndrome de Dificultad Respiratoria/etiología , Síndrome de Dificultad Respiratoria/fisiopatología , Mecánica Respiratoria , SARS-CoV-2
19.
Crit Care Med ; 48(8): 1148-1156, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32697485

RESUMEN

OBJECTIVES: Different techniques exist to select personalized positive end-expiratory pressure in patients affected by the acute respiratory distress syndrome. The positive end-expiratory transpulmonary pressure strategy aims to counteract dorsal lung collapse, whereas electrical impedance tomography could guide positive end-expiratory pressure selection based on optimal homogeneity of ventilation distribution. We compared the physiologic effects of positive end-expiratory pressure guided by electrical impedance tomography versus transpulmonary pressure in patients affected by acute respiratory distress syndrome. DESIGN: Cross-over prospective physiologic study. SETTING: Two academic ICUs. PATIENTS: Twenty ICU patients affected by acute respiratory distress syndrome undergoing mechanical ventilation. INTERVENTION: Patients monitored by an esophageal catheter and a 32-electrode electrical impedance tomography monitor underwent two positive end-expiratory pressure titration trials by randomized cross-over design to find the level of positive end-expiratory pressure associated with: 1) positive end-expiratory transpulmonary pressure (PEEPPL) and 2) proportion of poorly or nonventilated lung units (Silent Spaces) less than or equal to 15% (PEEPEIT). Each positive end-expiratory pressure level was maintained for 20 minutes, and afterward, lung mechanics, gas exchange, and electrical impedance tomography data were collected. MEASUREMENTS AND MAIN RESULTS: PEEPEIT and PEEPPL differed in all patients, and there was no correlation between the levels identified by the two methods (Rs = 0.25; p = 0.29). PEEPEIT determined a more homogeneous distribution of ventilation with a lower percentage of dependent Silent Spaces (p = 0.02), whereas PEEPPL was characterized by lower airway-but not transpulmonary-driving pressure (p = 0.04). PEEPEIT was significantly higher than PEEPPL in subjects with extrapulmonary acute respiratory distress syndrome (p = 0.006), whereas the opposite was true for pulmonary acute respiratory distress syndrome (p = 0.03). CONCLUSIONS: Personalized positive end-expiratory pressure levels selected by electrical impedance tomography- and transpulmonary pressure-based methods are not correlated at the individual patient level. PEEPPL is associated with lower dynamic stress, whereas PEEPEIT may help to optimize lung recruitment and homogeneity of ventilation. The underlying etiology of acute respiratory distress syndrome could deeply influence results from each method.


Asunto(s)
Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Anciano , Estudios Cruzados , Impedancia Eléctrica , Femenino , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Medicina de Precisión/métodos , Volumen de Ventilación Pulmonar , Tomografía/métodos
20.
Crit Care Med ; 48(11): e1129-e1136, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32947472

RESUMEN

OBJECTIVES: Reintubation after failed extubation is associated with increased mortality and longer hospital length of stay. Noninvasive oxygenation modalities may prevent reintubation. We conducted a systematic review and meta-analysis to determine the safety and efficacy of high-flow nasal cannula after extubation in critically ill adults. DATA SOURCES: We searched MEDLINE, EMBASE, and Web of Science. STUDY SELECTION: We included randomized controlled trials comparing high-flow nasal cannula to other noninvasive methods of oxygen delivery after extubation in critically ill adults. DATA EXTRACTION: We included the following outcomes: reintubation, postextubation respiratory failure, mortality, use of noninvasive ventilation, ICU and hospital length of stay, complications, and comfort. DATA SYNTHESIS: We included eight randomized controlled trials (n = 1,594 patients). Compared with conventional oxygen therapy, high-flow nasal cannula decreased reintubation (relative risk, 0.46; 95% CI, 0.30-0.70; moderate certainty) and postextubation respiratory failure (relative risk, 0.52; 95% CI, 0.30-0.91; very low certainty), but had no effect on mortality (relative risk, 0.93; 95% CI, 0.57-1.52; moderate certainty), or ICU length of stay (mean difference, 0.05 d fewer; 95% CI, 0.83 d fewer to 0.73 d more; high certainty). High-flow nasal cannula may decrease use of noninvasive ventilation (relative risk, 0.64; 95% CI, 0.34-1.22; moderate certainty) and hospital length of stay (mean difference, 0.98 d fewer; 95% CI, 2.16 d fewer to 0.21 d more; moderate certainty) compared with conventional oxygen therapy, however, certainty was limited by imprecision. Compared with noninvasive ventilation, high-flow nasal cannula had no effect on reintubation (relative risk, 1.16; 95% CI, 0.86-1.57; low certainty), mortality (relative risk, 1.12; 95% CI, 0.82-1.53; moderate certainty), or postextubation respiratory failure (relative risk, 0.82; 95% CI, 0.48-1.41; very low certainty). High-flow nasal cannula may reduce ICU length of stay (moderate certainty) and hospital length of stay (moderate certainty) compared with noninvasive ventilation. CONCLUSIONS: High-flow nasal cannula reduces reintubation compared with conventional oxygen therapy, but not compared with noninvasive ventilation after extubation.


Asunto(s)
Cánula , Ventilación no Invasiva , Terapia por Inhalación de Oxígeno , Extubación Traqueal , Humanos , Ventilación no Invasiva/métodos , Oxígeno/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA