Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Mater Sci Mater Med ; 26(1): 5332, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25577214

RESUMEN

The increasing number of total joint replacements, in particular for the knee joint, has a growing impact on the healthcare system costs. New cost-saving manufacturing technologies are being explored nowadays. Metal injection molding (MIM) has already demonstrated its suitability for the production of CoCrMo alloy tibial trays, with a significant reduction in production costs, by holding both corrosion resistance and biocompatibility. In this work, mechanical and tribological properties were evaluated on tibial trays obtained via MIM and conventional investment casting. Surface hardness and wear properties were evaluated through Vickers hardness, scratch and pin on disk tests. The MIM and cast finished tibial trays were then subjected to a fatigue test campaign in order to obtain their fatigue load limit at 5 millions cycles following ISO 14879-1 directions. CoCrMo cast alloy exhibited 514 HV hardness compared to 335 HV of MIM alloy, furthermore it developed narrower scratches with a higher tendency towards microploughing than microcutting, in comparison to MIM CoCrMo. The observed fatigue limits were (1,766 ± 52) N for cast tibial trays and (1,625 ± 44) N for MIM ones. Fracture morphologies pointed out to a more brittle behavior of MIM microstructure. These aspects were attributed to the absence of a fine toughening and surface hardening carbide dispersion in MIM grains. Nevertheless, MIM tibial trays exhibited a fatigue limit far beyond the 900 N of maximum load prescribed by ISO and ASTM standards for the clinical application of these devices.


Asunto(s)
Prótesis Articulares , Metales/química , Diseño de Prótesis , Materiales Biocompatibles , Humanos , Microscopía Electrónica de Rastreo
2.
Acta Biomater ; 75: 3-10, 2018 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-29772346

RESUMEN

Bioactive glasses (BGs) are being increasingly considered for biomedical applications in bone and soft tissue replacement approaches thanks to their ability to form strong bonding with tissues. However, due to their high reactivity once in contact with water-based solutions BGs rapidly exchange ions with the surrounding environment leading in most cases to an undesired increase of the pH under static in vitro conditions (due to alkaline ion "burst release"), making difficult or even impossible to perform cell culture studies. Several pre-conditioning treatments have been therefore proposed in laboratories worldwide to limit this problem. This paper presents an overview of the different strategies that have been put forward to pre-treat BG samples to tackle the pH raise issue in order to enable cell biology studies. The paper also discusses the relevant criteria that determine the selection of the optimal pre-treatment depending on the BG composition and morphology (e.g. particles, scaffolds). STATEMENT OF SIGNIFICANCE: Bioactive glasses (BGs), since their discovery in 1971 by L.L Hench, have been widely used for bone replacement and repair, and, more recently, they are becoming highly attractive for bone and soft tissue engineering applications. BGs have in fact the ability to form a strong bond with both hard and soft tissues once in contact with biological fluid. The enhanced interaction of BGs with the biological environment is based on their significant surface bioreactivity. This surface effect of BGs is, on the other hand, problematic for cell biology studies by standard (static) cell culture methods: an excessive bioreactivity leads in most cases to a rapid and dramatic increase of the pH of the surrounding medium, which results in cell death and makes cell culture tests on BG samples impossible. The BG research community has been aware of this for many years and numerous pre-treatments have been proposed by different groups worldwide to limit this problem. For the first time, we have reviewed in this paper the variety of surface preconditioning treatments that have been put forward over the years, we provide a summary of such pre-treatments used in laboratory practice, discussing and offering criteria that can be used for the determination of the optimal pre-treatment depending on BG composition and morphology of the sample tested (bulk, particulate, scaffolds). The information and discussion provided in this review should support best research practice when testing bioactive glasses in cell culture.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/normas , Vidrio/química , Vidrio/normas , Animales , Humanos , Concentración de Iones de Hidrógeno , Intercambio Iónico
3.
Biomed Mater ; 11(1): 015005, 2016 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-26836444

RESUMEN

Large bone defects are challenging to heal, and often require an osteoconductive and stable support to help the repair of damaged tissue. Bioglass-based scaffolds are particularly promising for this purpose due to their ability to stimulate bone regeneration. However, processing technologies adopted so far do not allow for the synthesis of scaffolds with suitable mechanical properties. Also, conventional sintering processes result in glass de-vitrification, which generates concerns about bioactivity. In this work, we studied the bioactivity and the mechanical properties of Bioglass(®) based scaffolds, produced via a powder technology inspired process. The scaffolds showed compressive strengths in the range of 5-40 MPa, i.e. in the upper range of values reported so far for these materials, had tunable porosity, in the range between 55 and 77%, and pore sizes that are optimal for bone tissue regeneration (100-500 µm). We immersed the scaffolds in simulated body fluid (SBF) for 28 d and analyzed the evolution of the scaffold mechanical properties and microstructure. Even if, after sintering, partial de-vitrification occurred, immersion in SBF caused ion release and the formation of a Ca-P coating within 2 d, which reached a thickness of 10-15 µm after 28 d. This coating contained both hydroxyapatite and an amorphous background, indicating microstructural amorphization of the base material. Scaffolds retained a good compressive strength and structural integrity also after 28 d of immersion (6 MPa compressive strength). The decrease in mechanical properties was mainly related to the increase in porosity, caused by its dissolution, rather than to the amorphization process and the formation of a Ca-P coating. These results suggest that Bioglass(®) based scaffolds produced via powder metallurgy-inspired technique are excellent candidates for bone regeneration applications.


Asunto(s)
Sustitutos de Huesos/síntesis química , Cerámica/química , Vidrio/química , Andamios del Tejido , Fuerza Compresiva , Módulo de Elasticidad , Diseño de Equipo , Análisis de Falla de Equipo , Dureza , Calefacción/métodos , Ensayo de Materiales , Metalurgia/métodos , Polvos , Estrés Mecánico , Resistencia a la Tracción
4.
J Biomed Mater Res B Appl Biomater ; 101(7): 1294-301, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23661502

RESUMEN

Industrial manufacturing of prosthesis components could take significant advantage by the introduction of new, cost-effective manufacturing technologies with near net-shape capabilities, which have been developed during the last years to fulfill the needs of different technological sectors. Among them, metal injection molding (MIM) appears particularly promising for the production of orthopedic arthroplasty components with significant cost saving. These new manufacturing technologies, which have been developed, however, strongly affect the chemicophysical structure of processed materials and their resulting properties. In order to investigate this relationship, here we evaluated the effects on electrochemical properties, ion release, and in vitro response of medical grade CoCrMo alloy processed via MIM compared to conventional processes. MIM of the CoCrMo alloy resulted in coarser polygonal grains, with largely varying sizes; however, these microstructural differences between MIM and forged/cast CoCrMo alloys showed a negligible effect on electrochemical properties. Passive current densities values observed were 0.49 µA cm(-2) for MIM specimens and 0.51 µA cm(-2) for forged CoCrMo specimens, with slightly lower transpassive potential in the MIM case; open circuit potential and Rp stationary values showed no significant differences. Moreover, in vitro biocompatibility tests resulted in cell viability levels not significantly different for MIM and conventionally processed alloys. Although preliminary, these results support the potential of MIM technology for the production of CoCrMo components of implantable devices.


Asunto(s)
Técnicas Electroquímicas , Ensayo de Materiales , Prótesis e Implantes , Vitalio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA