Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Xray Sci Technol ; 31(1): 181-197, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36404567

RESUMEN

OBJECTIVE: This study aims to develop and test a new technique by using the convergent arcTAN (cATAN) method capable of dealing with the virtual source position delivered by different carbon ion energies from the pattern of scanning-passive scatter beam. MATERIALS AND METHODS: A homemade large-format CMOS sensor and Gaf Chromic EBT3 films are used for the virtual source position measurement. The Gaf films are embedded in a self-designed rectangular plastic frame to tighten films and set up on a treatment couch for irradiation in air with the film perpendicular to the carbon ion beam at the nominal source-axis-distance (SAD) as well as upstream and downstream from the SAD. The horizontal carbon ion beam with 5 energies at a machine opening field size is carried out in this study. The virtual source position is determined by using the convergent arcTAN (cATAN) method and compared with a linear regression by back projecting FWHM to zero at a distance upstream from the various source-film-distance. RESULTS: The film FWHM measurement error of 0.5 mm leads to 0.001% deviation of α (cATAN) at every assumed textend. The overall uncertainty for the reproducibility of calculated virtual source position by the assumed textend in the vertical and horizontal directions amounts to 0.1%. The errors of calculated virtual source position by assumed textend with back projecting FWHM to zero methods are within 1.1±0.001, p = 0.033. CONCLUSION: We develop a new technique capable of dealing with the virtual source position with a convergent arcTAN method to avoid any manual measurement mistakes in scanning-passive scatter carbon ion beam. The readers are encouraged to conduct the proposed cATAN method in this study to investigate the virtual source position in the Linac-based external electron beams and the proton beams.


Asunto(s)
Radioterapia de Iones Pesados , Reproducibilidad de los Resultados , Incertidumbre , Modelos Lineales , Carbono
2.
Biomed Res Int ; 2021: 8808537, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34722774

RESUMEN

PURPOSE: An experimental and mathematical study for determining the effective point of measurement (P eff) for a Farmer-type cylindrical chamber in a carbon ion passive scatter beam is presented. METHODS: The ionization depth curves measured by the Bragg peak chamber were plotted according to the position of the inner surface of the entrance window, while the Farmer chamber was plotted at the tip of the cylindrical geometric center. The ionization depth curves measured by a cylindrical chamber in the 3D water phantom were then compared with a high-precision parallel-plate PTW Bragg peak chamber for inspecting the upstream shift correction of the cylindrical chamber in the carbon ion beam. A component of the vertical and horizontal integration method and the barrier model, cosφ = 1 - [2αR L /(1 + α - R L )], for analyzing the shift of effective point of measurement in different carbon ion energies and various field sizes, were studied. RESULTS: The shift between the maximum peak of the Bragg peak chamber and the Farmer chamber in a field size of 10 cm × 10 cm with an energy of 330 MeV/u of carbon ion is 2.3 mm. This upstream shift corresponds to (0.744 ± 0.07)r, where r is the Farmer chamber inner radius of 3.05 mm. Carbon ion energy from 120 MeV/u to 400 MeV/u with different field sizes show different shifts of effective point of measurement in a range of (0.649 ± 0.02)r to (0.843 ± 0.06)r of 3 cm × 3 cm at an energy of 400 MeV/u and 10 cm × 10 cm at an energy of 120 MeV/u, respectively. The vertical and horizontal scatter analysis by the barrier model can precisely describe the shift of the effective point of measurement at different carbon ion energies with various field sizes. CONCLUSIONS: We conclude that the Farmer chamber can be used for a patient-specific dose verification check in carbon ion beam treatment if P eff is well calibrated.


Asunto(s)
Relación Dosis-Respuesta en la Radiación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Calibración , Carbono , Electrones , Iones , Fotones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA