RESUMEN
Background Distinguishing lumbar pain generators from incidental findings at MRI can be difficult. Dictated reports may become lists of findings that cannot be ranked in order of diagnostic importance. Purpose To determine whether patient-reported symptom information can improve the interpretation of lumbar spine MRI by using the spine specialist as the reference standard. Materials and Methods This prospective, single-center, multireader study analyzed 240 participants who completed pre-MRI symptom questionnaires between May 2022 and February 2023. At the time of clinical MRI reporting, radiologists recorded pain generators in consecutive participants, creating two study groups by alternating interpretations with versus without symptom questionnaire results (SQR). Diagnostic certainty was recorded using a numeric scale of 0 to 100. Types, levels, and sides of pain generators were compared with reference diagnoses by calculating Cohen κ values with 95% CIs. Participant characteristics and diagnostic certainties were compared using the Wilcoxon rank sum, Pearson χ2, or Kruskal-Wallis test. Interrater agreement was analyzed. Results There was no difference in age (P = .69) or sex (P = .60) between participants using SQR (n = 120; mean age, 61.0 years; 62 female) and not using SQR (n = 120; mean age, 62.5 years; 67 female). When radiologists were compared with specialists, agreements on pain generators were almost perfect for interpretations using SQR (type: κ = 0.82 [95% CI: 0.74,0.89]; level: κ = 0.88 [95% CI: 0.80, 0.95]; side: κ = 0.84 [95% CI: 0.75, 0.92]), but only fair to moderate for interpretations not using SQR (type: κ = 0.26 [95% CI: 0.15, 0.36]; level: κ = 0.51 [95% CI: 0.39, 0.63]; side: κ = 0.30 [95% CI: 0.18, 0.42]) (all P < .001). Diagnostic certainty was higher for MRI interpretations using SQR (mean, 80.4 ± 14.9 [SD]) than MRI interpretations not using SQR (60.5 ± 17.7) (P < .001). Interrater agreements were substantial (κ = 0.65-0.78) for MRI interpretations using SQR but only fair to moderate (κ = 0.24-0.49) for MRI interpretations not using SQR (all P < .001). Conclusion Patient-reported symptom information enabled radiologists to achieve nearly perfect diagnostic agreement with clinical experts. © RSNA, 2024 See also the editorial by Isikbay and Shah in this issue.
Asunto(s)
Vértebras Lumbares , Imagen por Resonancia Magnética , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Vértebras Lumbares/diagnóstico por imagen , Encuestas y Cuestionarios , Dolor de la Región Lumbar/diagnóstico por imagen , Anciano , AdultoRESUMEN
BACKGROUND. Mammography surveillance protocols after breast cancer treatment vary widely. Some practices recommend performing diagnostic mammography for a certain number of years or indefinitely, whereas others recommend returning immediately to screening. OBJECTIVE. This study's objective was to determine performance metrics of screening digital breast tomosynthesis (DBT) in patients who resume screening mammography immediately after breast cancer treatment, based on the number of years since the breast cancer diagnosis. METHODS. This retrospective study included screening DBT examinations performed from January 2013 to June 2019 in patients who resumed screening mammography immediately after a prior breast cancer diagnosis. Multivariable logistic regression models with generalized estimating equations were used to evaluate associations between screening performance metrics and years since the prior breast cancer diagnosis, controlling for age, race and ethnicity, breast density, presence of a prior screening mammogram, and interpreting radiologist. RESULTS. The study included 8090 patients (mean age, 65 ± 11 [SD] years) with a prior breast cancer diagnosis who underwent 30,812 screening DBT examinations during the study period. The cancer detection rate (CDR) was 8.6 per 1000 examinations (265/30,812), abnormal interpretation rate (AIR) was 5.7% (1750/30,812), PPV1 was 15.1% (265/1750), sensitivity was 80.3% (265/330), specificity was 95.1% (28,997/30,482), and false-negative rate was 2.1 per 1000 examinations (65/30,812). CDR showed a significant independent positive association with years since breast cancer diagnosis (adjusted OR, 1.03; 95% CI, 1.01-1.05; p < .001), being lowest more than 2 to up to 3 years after diagnosis (4.9 per 1000 examinations) and highest more than 8 to up to 9 years after diagnosis (11.2 per 1000 examinations). AIR showed a significant independent negative association with years since breast cancer diagnosis (adjusted OR, 0.99; 95% CI, 0.98-1.00; p = .01), being highest 1 year or less after diagnosis (7.5%) and lowest more than 5 to up to 6 years after diagnosis (5.0%). CONCLUSION. Among 8090 patients with a prior breast cancer diagnosis, even though the AIR was higher during the year after diagnosis compared with subsequent years, the AIR remained acceptably low (< 10%) in all years. CLINICAL IMPACT. These results support the study institution's mammographic surveillance protocol for patients with a prior breast cancer diagnosis of returning immediately to DBT screening.
Asunto(s)
Neoplasias de la Mama , Humanos , Persona de Mediana Edad , Anciano , Femenino , Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Estudios Retrospectivos , Detección Precoz del Cáncer/métodos , Densidad de la Mama , Tamizaje Masivo/métodosRESUMEN
BACKGROUND. The 2022 Society of Radiologists in Ultrasound (SRU) consensus conference recommendations for small gallbladder polyps support management that is less aggressive than earlier approaches and may help standardize evaluation of polyps by radiologists. OBJECTIVE. The purpose of the present study was to assess the interreader agreement of radiologists in applying SRU recommendations for management of incidental gallbladder polyps on ultrasound. METHODS. This retrospective study included 105 patients (75 women and 30 men; median age, 51 years) with a gallbladder polyp on ultrasound (without features highly suspicious for invasive or malignant tumor) who underwent cholecystectomy between January 1, 2003, and January 1, 2021. Ten abdominal radiologists independently reviewed ultrasound examinations and, using the SRU recommendations, assessed one polyp per patient to assign risk category (extremely low risk, low risk, or indeterminate risk) and make a possible recommendation for surgical consultation. Five radiologists were considered less experienced (< 5 years of experience), and five were considered more experienced (≥ 5 years of experience). Interreader agreement was evaluated. Polyps were classified pathologically as nonneoplastic or neoplastic. RESULTS. For risk category assignments, interreader agreement was substantial among all readers (k = 0.710), less-experienced readers (k = 0.705), and more-experienced readers (k = 0.692). For surgical consultation recommendations, inter-reader agreement was substantial among all readers (k = 0.795) and more-experienced readers (k = 0.740) and was almost perfect among less-experienced readers (k = 0.811). Of 10 readers, a median of 5.0 (IQR, 2.0-8.0), 4.0 (IQR, 2.0-7.0), and 0.0 (IQR, 0.0-0.0) readers classified polyps as extremely low risk, low risk, and indeterminate risk, respectively. Across readers, the percentage of polyps classified as extremely low risk ranged from 32% to 72%; as low risk, from 24% to 65%; and as indeterminate risk, from 0% to 8%. Of 10 readers, a median of zero change to 0 (IQR, 0.0-1.0) readers recommended surgical consultation; the percentage of polyps receiving a recommendation for surgical consultation ranged from 4% to 22%. Of a total of 105 polyps, 102 were nonneo-plastic and three were neoplastic (all benign). Based on readers' most common assessments for nonneoplastic polyps, the risk category was extremely low risk for 53 polyps, low risk for 48 polyps, and indeterminate risk for one polyp; surgical consultation was recommended for 16 polyps. CONCLUSION. Ten abdominal radiologists showed substantial agreement for polyp risk categorizations and surgical consultation recommendations, although areas of reader variability were identified. CLINICAL IMPACT. The findings support the overall reproducibility of the SRU recommendations, while indicating opportunity for improvement.
Asunto(s)
Hallazgos Incidentales , Pólipos , Ultrasonografía , Humanos , Femenino , Masculino , Persona de Mediana Edad , Pólipos/diagnóstico por imagen , Pólipos/cirugía , Estudios Retrospectivos , Ultrasonografía/métodos , Adulto , Enfermedades de la Vesícula Biliar/diagnóstico por imagen , Enfermedades de la Vesícula Biliar/cirugía , Anciano , Variaciones Dependientes del Observador , Radiólogos , Sociedades Médicas , Consenso , Guías de Práctica Clínica como AsuntoRESUMEN
Background Access to supplemental screening breast MRI is determined using traditional risk models, which are limited by modest predictive accuracy. Purpose To compare the diagnostic accuracy of a mammogram-based deep learning (DL) risk assessment model to that of traditional breast cancer risk models in patients who underwent supplemental screening with MRI. Materials and Methods This retrospective study included consecutive patients undergoing breast cancer screening MRI from September 2017 to September 2020 at four facilities. Risk was assessed using the Tyrer-Cuzick (TC) and National Cancer Institute Breast Cancer Risk Assessment Tool (BCRAT) 5-year and lifetime models as well as a DL 5-year model that generated a risk score based on the most recent screening mammogram. A risk score of 1.67% or higher defined increased risk for traditional 5-year models, a risk score of 20% or higher defined high risk for traditional lifetime models, and absolute scores of 2.3 or higher and 6.6 or higher defined increased and high risk, respectively, for the DL model. Model accuracy metrics including cancer detection rate (CDR) and positive predictive values (PPVs) (PPV of abnormal findings at screening [PPV1], PPV of biopsies recommended [PPV2], and PPV of biopsies performed [PPV3]) were compared using logistic regression models. Results This study included 2168 women who underwent 4247 high-risk screening MRI examinations (median age, 54 years [IQR, 48-60 years]). CDR (per 1000 examinations) was higher in patients at high risk according to the DL model (20.6 [95% CI: 11.8, 35.6]) than according to the TC (6.0 [95% CI: 2.9, 12.3]; P < .01) and BCRAT (6.8 [95% CI: 2.9, 15.8]; P = .04) lifetime models. PPV1, PPV2, and PPV3 were higher in patients identified as high risk by the DL model (PPV1, 14.6%; PPV2, 32.4%; PPV3, 36.4%) than those identified as high risk with the TC (PPV1, 5.0%; PPV2, 12.7%; PPV3, 13.5%; P value range, .02-.03) and BCRAT (PPV1, 5.5%; PPV2, 11.1%; PPV3, 12.5%; P value range, .02-.05) lifetime models. Conclusion Patients identified as high risk by a mammogram-based DL risk assessment model showed higher CDR at breast screening MRI than patients identified as high risk with traditional risk models. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bae in this issue.
Asunto(s)
Neoplasias de la Mama , Aprendizaje Profundo , Humanos , Femenino , Persona de Mediana Edad , Detección Precoz del Cáncer , Neoplasias de la Mama/diagnóstico por imagen , Estudios Retrospectivos , Imagen por Resonancia MagnéticaRESUMEN
OBJECTIVE: To investigate the impact of thoracic body composition on outcomes after lobectomy for lung cancer. SUMMARY AND BACKGROUND DATA: Preoperative identification of patients at risk for adverse outcomes permits treatment modification. The impact of body composition on lung resection outcomes has not been investigated in a multicenter setting. METHODS: A total of 958 consecutive patients undergoing lobectomy for lung cancer at 3 centers from 2014 to 2017 were retrospectively analyzed. Muscle and adipose tissue cross-sectional area at the fifth, eighth, and tenth thoracic vertebral body was quantified. Prospectively collected outcomes from a national database were abstracted to characterize the association between sums of muscle and adipose tissue and hospital length of stay (LOS), number of any postoperative complications, and number of respiratory postoperative complications using multivariate regression. A priori determined covariates were forced expiratory volume in 1 second and diffusion capacity of the lungs for carbon monoxide predicted, age, sex, body mass index, race, surgical approach, smoking status, Zubrod and American Society of Anesthesiologists scores. RESULTS: Mean patient age was 67âyears, body mass index 27.4âkg/m2 and 65% had stage i disease. Sixty-three percent underwent minimally invasive lobectomy. Median LOS was 4âdays and 34% of patients experienced complications. Muscle (using 30âcm2 increments) was an independent predictor of LOS (adjusted coefficient 0.972; P = 0.002), any postoperative complications (odds ratio 0.897; P = 0.007) and postoperative respiratory complications (odds ratio 0.860; P = 0.010). Sarcopenic obesity was also associated with LOS and adverse outcomes. CONCLUSIONS: Body composition on preoperative chest computed tomography is an independent predictor of LOS and postoperative complications after lobectomy for lung cancer.
Asunto(s)
Neoplasias Pulmonares , Neumonectomía , Anciano , Composición Corporal , Hospitales , Humanos , Tiempo de Internación , Neoplasias Pulmonares/cirugía , Neumonectomía/efectos adversos , Neumonectomía/métodos , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Tomografía Computarizada por Rayos XRESUMEN
BACKGROUND AND AIMS: Advances in cross-sectional imaging have resulted in increased detection of intraductal papillary mucinous neoplasms (IPMNs), and their management remains controversial. At present, there is no reliable noninvasive method to distinguish between indolent and high risk IPMNs. We performed extracellular vesicle (EV) analysis to identify markers of malignancy in an attempt to better stratify these lesions. METHODS: Using a novel ultrasensitive digital extracellular vesicle screening technique (DEST), we measured putative biomarkers of malignancy (MUC1, MUC2, MUC4, MUC5AC, MUC6, Das-1, STMN1, TSP1, TSP2, EGFR, EpCAM, GPC1, WNT-2, EphA2, S100A4, PSCA, MUC13, ZEB1, PLEC1, HOOK1, PTPN6, and FBN1) in EV from patient-derived cell lines and then on circulating EV obtained from peripheral blood drawn from patients with IPMNs. We enrolled a total of 133 patients in two separate cohorts: a clinical discovery cohort (n = 86) and a validation cohort (n = 47). RESULTS: From 16 validated EV proteins in plasma samples collected from the discovery cohort, only MUC5AC showed significantly higher levels in high-grade lesions. Of the 11 patients with invasive IPMN (inv/HG), 9 had high MUC5AC expression in plasma EV of the 11 patients with high-grade dysplasia alone, only 1 had high MUC5AC expression (sensitivity of 82%, specificity of 100%). These findings were corroborated in a separate validation cohort. The addition of MUC5AC as a biomarker to imaging and high-riskstigmata allowed detection of all cases requiring surgery, whereas imaging and high-risk stigmata alone would have missed 5 of 14 cases (36%). CONCLUSIONS: MUC5AC in circulating EV can predict the presence of invasive carcinoma within IPMN. This approach has the potential to improve the management and follow-up of patients with IPMN including avoiding unnecessary surgery.
Asunto(s)
Biomarcadores de Tumor/sangre , Carcinoma Ductal Pancreático/diagnóstico , Vesículas Extracelulares/metabolismo , Neoplasias Intraductales Pancreáticas/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Animales , Biomarcadores de Tumor/metabolismo , Carcinoma Ductal Pancreático/sangre , Carcinoma Ductal Pancreático/patología , Diagnóstico Diferencial , Femenino , Voluntarios Sanos , Humanos , Biopsia Líquida/métodos , Masculino , Ratones , Persona de Mediana Edad , Mucina 5AC/sangre , Mucina 5AC/metabolismo , Invasividad Neoplásica/patología , Conductos Pancreáticos/diagnóstico por imagen , Conductos Pancreáticos/patología , Neoplasias Intraductales Pancreáticas/sangre , Neoplasias Intraductales Pancreáticas/patología , Neoplasias Pancreáticas/sangre , Neoplasias Pancreáticas/patología , Prueba de Estudio Conceptual , Ensayos Antitumor por Modelo de XenoinjertoRESUMEN
BACKGROUND. Screening mammography facilities closed during the COVID-19 pandemic in spring 2020. Recovery of screening volumes has varied across patient subgroups and facilities. OBJECTIVE. We compared screening mammography volumes and patient and facility characteristics between periods before COVID-19 and early and later postclosure recovery periods. METHODS. This retrospective study included screening mammograms performed in the same 2-month period (May 26-July 26) in 2019 (pre-COVID-19), 2020 (early recovery), and 2021 (late recovery after targeted interventions to expand access) and across multiple facility types (urban, suburban, community health center). Suburban sites had highest proportion of White patients and the greatest scheduling flexibility and expanded appointments during initial reopening. Findings were compared across years. RESULTS. For White patients, volumes decreased 36.6% from 6550 in 2019 (4384 in 2020) and then increased 61.0% to 6579 in 2021; for patients with races other than White, volumes decreased 53.9% from 1321 in 2019 (609 in 2020) and then increased 136.8% to 1442 in 2021. The percentage of mammograms in patients with races other than White was 16.8% in 2019, 12.2% in 2020, and 18.0% in 2021. The proportion performed at the urban center was 55.3% in 2019, 42.2% in 2020, and 45.9% in 2021; the proportion at suburban sites was 34.0% in 2019, 49.2% in 2020, and 43.5% in 2021. Pre-COVID-19 volumes were reached by the sixth week after reopening for suburban sites but were not reached during early recovery for the other sites. The proportion that were performed on Saturday for suburban sites was similar across periods, whereas the proportion performed on Saturday for the urban site was 7.6% in 2019, 5.3% in 2020, and 8.8% in 2021; the community health center did not offer Saturday appointments during recovery. CONCLUSION. After reopening, screening shifted from urban to suburban settings, with a disproportionate screening decrease in patients with races other than White. Initial delayed access at facilities serving underserved populations exacerbated disparities. Interventions to expand access resulted in late recovery volumes exceeding prepandemic volumes in patients with races other than White. CLINICAL IMPACT. Interventions to support equitable access across facilities serving diverse patient populations may mitigate potential widening disparities in breast cancer diagnosis during the pandemic.
Asunto(s)
Neoplasias de la Mama , COVID-19 , Accesibilidad Arquitectónica , Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer , Femenino , Humanos , Mamografía/métodos , Tamizaje Masivo , Pandemias , Estudios RetrospectivosRESUMEN
BACKGROUND. The need for second visits between screening mammography and diagnostic imaging contributes to disparities in the time to breast cancer diagnosis. During the COVID-19 pandemic, an immediate-read screening mammography program was implemented to reduce patient visits and decrease time to diagnostic imaging. OBJECTIVE. The purpose of this study was to measure the impact of an immediate-read screening program with focus on disparities in same-day diagnostic imaging after abnormal findings are made at screening mammography. METHODS. In May 2020, an immediate-read screening program was implemented whereby a dedicated breast imaging radiologist interpreted all screening mammograms in real time; patients received results before discharge; and efforts were made to perform any recommended diagnostic imaging during the visit (performed by different radiologists). Screening mammographic examinations performed from June 1, 2019, through October 31, 2019 (preimplementation period), and from June 1, 2020, through October 31, 2020 (postimplementation period), were retrospectively identified. Patient characteristics were recorded from the electronic medical record. Multivariable logistic regression models incorporating patient age, race and ethnicity, language, and insurance type were estimated to identify factors associated with same-day diagnostic imaging. Screening metrics were compared between periods. RESULTS. A total of 8222 preimplementation and 7235 postimplementation screening examinations were included; 521 patients had abnormal screening findings before implementation, and 359 after implementation. Before implementation, 14.8% of patients underwent same-day diagnostic imaging after abnormal screening mammograms. This percentage increased to 60.7% after implementation. Before implementation, patients who identified their race as other than White had significantly lower odds than patients who identified their race as White of undergoing same-day diagnostic imaging after receiving abnormal screening results (adjusted odds ratio, 0.30; 95% CI, 0.10-0.86; p = .03). After implementation, the odds of same-day diagnostic imaging were not significantly different between patients of other races and White patients (adjusted odds ratio, 0.92; 95% CI, 0.50-1.71; p = .80). After implementation, there was no significant difference in race and ethnicity between patients who underwent and those who did not undergo same-day diagnostic imaging after receiving abnormal results of screening mammography (p > .05). The rate of abnormal interpretation was significantly lower after than it was before implementation (5.0% vs 6.3%; p < .001). Cancer detection rate and PPV1 (PPV based on positive findings at screening examination) were not significantly different before and after implementation (p > .05). CONCLUSION. Implementation of the immediate-read screening mammography program reduced prior racial and ethnic disparities in same-day diagnostic imaging after abnormal screening mammograms. CLINICAL IMPACT. An immediate-read screening program provides a new paradigm for improved screening mammography workflow that allows more rapid diagnostic workup with reduced disparities in care.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , COVID-19/prevención & control , Diagnóstico Tardío/prevención & control , Disparidades en Atención de Salud/estadística & datos numéricos , Interpretación de Imagen Asistida por Computador/métodos , Mamografía/métodos , Grupos Raciales/estadística & datos numéricos , Adulto , Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Pandemias , Estudios Retrospectivos , SARS-CoV-2 , TiempoRESUMEN
BACKGROUND: Thrombosis of the left internal jugular vein in an astronaut aboard the International Space Station was recently described, incidentally discovered during a research study of blood flow in neck veins in microgravity. Given this event, and the high incidence of flow abnormalities, the National Aeronautics and Space Administration (NASA) instituted an occupational surveillance program to evaluate astronauts for venous thrombosis. METHODS: Duplex ultrasound of the bilateral internal jugular veins was conducted on all NASA astronauts terrestrially, and at three points during spaceflight. Respiratory maneuvers were performed. Images were analyzed for thrombosis and certain hemodynamic characteristics, including peak velocity and degree of echogenicity. RESULTS: Eleven astronauts were evaluated with matching terrestrial and in-flight ultrasounds. No thrombosis was detected. Compared to terrestrial ultrasound measurements, in-flight peak velocity was reduced and lowest in the left. Six of 11 astronauts had mild-moderate echogenicity in the left internal jugular vein during spaceflight, but none had more than mild echogenicity in the right internal jugular vein. Two astronauts developed retrograde blood flow in the left internal jugular vein. CONCLUSION: Abnormal flow characteristics in microgravity, most prominent in the left internal jugular vein, may signal an increased risk for thrombus formation in some individuals.
Asunto(s)
Vuelo Espacial , Trombosis , Trombosis de la Vena , Ingravidez , Astronautas , Humanos , Venas Yugulares/diagnóstico por imagen , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Ingravidez/efectos adversosRESUMEN
Missing data are a common problem for both the construction and implementation of a prediction algorithm. Pattern submodels (PS)-a set of submodels for every missing data pattern that are fit using only data from that pattern-are a computationally efficient remedy for handling missing data at both stages. Here, we show that PS (i) retain their predictive accuracy even when the missing data mechanism is not missing at random (MAR) and (ii) yield an algorithm that is the most predictive among all standard missing data strategies. Specifically, we show that the expected loss of a forecasting algorithm is minimized when each pattern-specific loss is minimized. Simulations and a re-analysis of the SUPPORT study confirms that PS generally outperforms zero-imputation, mean-imputation, complete-case analysis, complete-case submodels, and even multiple imputation (MI). The degree of improvement is highly dependent on the missingness mechanism and the effect size of missing predictors. When the data are MAR, MI can yield comparable forecasting performance but generally requires a larger computational cost. We also show that predictions from the PS approach are equivalent to the limiting predictions for a MI procedure that is dependent on missingness indicators (the MIMI model). The focus of this article is on out-of-sample prediction; implications for model inference are only briefly explored.
Asunto(s)
Investigación Biomédica/métodos , Bioestadística/métodos , Interpretación Estadística de Datos , Modelos Estadísticos , HumanosRESUMEN
PURPOSE: Mammography screening encounters may represent ideal opportunities to identify high-risk women for risk-based screening. During mammography appointments, radiology practices evaluate breast density and ascertain known breast cancer risk factors. Our purpose was to evaluate the potential for mammographic screening encounters to identify high-risk women by estimating the (1) proportion of high-risk women who report that they have undergone mammographic screening and the (2) proportion of high-risk women who receive recommendations for breast MRI screening. METHODS: Women ages 30-85 without breast cancer histories were included from the 2015 National Health Interview Survey, a nationally representative cross-sectional household survey (response rate 80%). Breast Cancer Risk Assessment Tool was used to determine high-risk (lifetime risk>20%). Among high-risk women, primary outcome was proportion reporting mammography screening, secondary outcome was receipt of a breast MRI recommendation after recent mammogram, accounting for complex survey design. RESULTS: 14,958 women were included. 1.0% were high-risk of whom: 91.9% ever had a mammogram, 68.0% had a mammogram within the last year, 81.5% had a mammogram within the last 2 years. 6.4% were recommended to undergo breast MRI. Among high-risk women, women with dense breast tissue were more likely (OR 496.0, 95%CI 52.6,4674.0) and older women were less likely (OR 0.91, 95%CI 0.84,0.99) to receive recommendations for breast MRI. CONCLUSIONS: Among high-risk women, 92% reported undergoing at least one mammogram in their lives. 94% did not receive recommendations for breast MRI screening and 32% did not have a mammogram within the last year. To identify high-risk women, breast imaging centers should consider determining lifetime breast cancer risk during mammography screening visits.
Asunto(s)
Neoplasias de la Mama , Mamografía , Adulto , Anciano , Anciano de 80 o más Años , Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , Estudios Transversales , Detección Precoz del Cáncer , Femenino , Humanos , Tamizaje Masivo , Persona de Mediana EdadRESUMEN
Background Among breast cancer survivors, detecting a breast cancer when it is asymptomatic (rather than symptomatic) improves survival; thus, imaging surveillance in these patients is warranted. Digital breast tomosynthesis (DBT) is used for screening, but data on DBT for surveillance in this high-risk population are limited. Purpose To determine whether DBT leads to improved screening performance metrics when compared with two-dimensional digital mammography among breast cancer survivors. Materials and Methods In this study, screening mammograms obtained in breast cancer survivors before and after DBT implementation were retrospectively reviewed (March 2008-February 2011 for the digital mammography group; January 2013-December 2017 for the DBT group). Mammograms were interpreted by breast imaging radiologists with the assistance of computer-aided detection. Performance metrics and tumor characteristics between the groups were compared using multivariable logistic regression models. Results The digital mammography and DBT groups were composed of 9019 and 22 887 mammographic examinations, respectively, in 8170 women (mean age, 62 years ± 12 [standard deviation]). In the DBT group, the abnormal interpretation rate was lower (5.8% [1331 of 22 887 examinations] vs 6.2% [563 of 9019 examinations]; odds ratio [OR], 0.80; 95% CI: 0.71, 0.91; P = .001) and specificity was higher (95.0% [21 502 of 22 644 examinations] vs 94.7% [8424 of 8891 examinations]; OR, 1.23; 95% CI: 1.07, 1.41; P = .003) than in the digital mammography group. The cancer detection rates did not differ (8.3 per 1000 examinations with DBT vs 10.6 with digital mammography; OR, 0.76; 95% CI: 0.57, 1.02; P = .07). The proportions of screening-detected invasive cancers, versus in situ cancers, were similar (74% [140 of 189 cancers] in the DBT group vs 72% [69 of 96 cancers] in the digital mammography group; P = .69). Of 86 interval cancers, 58% (50 of 86 cancers) manifested with symptoms, and 33% (28 of 86 cancers) were detected at screening MRI. Conclusion Among breast cancer survivors, screening with digital breast tomosynthesis led to fewer false-positive results and higher specificity but did not affect cancer detection. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Hooley and Butler in this issue.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Supervivientes de Cáncer/estadística & datos numéricos , Mamografía/métodos , Anciano , Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y EspecificidadRESUMEN
BACKGROUND: Reexcision following breast-conserving surgery (BCS) in women with ductal carcinoma in situ (DCIS) results in adjuvant treatment delays, higher health care costs, and undesirable cosmetic outcomes. The purpose of this study is to determine patient, imaging, pathological, and surgical predictors of reexcision following BCS for DCIS. PATIENTS AND METHODS: A retrospective review of women with DCIS who had BCS from 2007 to 2016 was conducted. Patient, imaging, pathological, and surgical features, in addition to surgical outcomes, were collected from medical records. Standard statistical tests were used to compare features between patients who did and did not undergo at least one reexcision. A multivariable logistic regression model was fit to assess features associated with reexcision. RESULTS: A total of 547 women (mean age 59 years; range 30-88 years) diagnosed with DCIS at core needle biopsy underwent BCS. Of all women, 31.6% (173/547) had at least one reexcision. With multivariable analysis, features associated with reexcision included younger patient age (adjusted odds ratio [aOR] 0.98, 95% confidence interval [CI] 0.97-1.0, p = 0.049), African-American race (aOR 2.66, 95% CI 1.13-6.26, p = 0.03), biopsy modality of ultrasound (aOR 2.35, 95% CI 1.22-4.53, p = 0.01), and earlier year of surgery (aOR 0.92, 95% CI 0.86-0.98, p = 0.01). No pathological features of DCIS were associated with reexcision risk. CONCLUSIONS: In our cohort of nearly 550 women with DCIS who underwent BCS, 31.6% had at least one reexcision. Features associated with reexcision include younger patient age, African-American race, biopsy modality of ultrasound, and earlier year of surgery.
Asunto(s)
Neoplasias de la Mama , Carcinoma Ductal de Mama , Carcinoma Intraductal no Infiltrante , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Estudios de Cohortes , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad , Oportunidad Relativa , Reoperación , Estudios RetrospectivosRESUMEN
BACKGROUND: Accurate diagnosis of idiopathic pulmonary fibrosis (IPF) is essential to inform prognosis and treatment. In 2018, the ATS/ERS/JRS/ALAT and Fleischner Society released new diagnostic guidelines for usual interstitial pneumonitis (UIP)/IPF, adding Probable UIP as a CT category based on prior studies demonstrating this category had relatively high positive predictive value (PPV) for histopathologic UIP/Probable UIP. This study applies the 2018 ATS/ERS/JRS/ALAT and Fleischner Society guidelines to determine test characteristics of CT categories in academic clinical practice. METHODS: CT and histopathology were evaluated by three thoracic radiologists and two thoracic pathologists. Comparison of consensus categorization by the 2018 ATS and Fleischner Society guidelines by CT and histopathology was performed. RESULTS: Of patients with CT UIP, 87% (PPV, 95% CI: 60-98%) had histopathologic UIP with 97% (CI: 90-100%) specificity. Of patients with CT Probable UIP, 38% (PPV, CI: 14-68%) had histopathologic UIP and 46% (PPV, CI: 19-75%) had either histopathologic UIP or Probable UIP, with 88% (CI: 77-95%) specificity. Patients with CT Indeterminate and Alternative Diagnosis had histopathologic UIP in 27% (PPV, CI: 6-61%) and 21% (PPV, CI: 11-33%) of cases with specificities of 90% (CI: 80-96%) and 25% (CI: 16-37%). Interobserver variability (kappa) between radiologists ranged 0.32-0.81. CONCLUSIONS: CT UIP and Probable UIP have high specificity for histopathologic UIP, and CT UIP has high PPV for histopathologic UIP. PPV of CT Probable UIP was 46% for combined histopathologic UIP/Probable UIP. Our results indicate that additional studies are needed to further assess and refine the guideline criteria to improve classification performance.
Asunto(s)
Fibrosis Pulmonar Idiopática/diagnóstico , Pulmón/diagnóstico por imagen , Pulmón/patología , Guías de Práctica Clínica como Asunto/normas , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , Anciano de 80 o más Años , Biopsia/normas , Femenino , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sociedades Médicas , Adulto JovenRESUMEN
OBJECTIVE. The purpose of this study is to determine the impact of shear-wave elastography (SWE) image quality parameters on the diagnostic performance of elasticity measurements in classifying breast lesions. MATERIALS AND METHODS. This retrospective study included 281 breast lesions that underwent SWE and ultrasound-guided biopsy performed between October 1, 2017, and August 31, 2018. Three readers who were blinded to pathologic outcomes independently scored the image quality of each SWE image (with low quality denoted by a score of 0 and high quality indicated by a score of 1) on the basis of five parameters: B-mode visualization of the lesion on a dual-panel display, SWE red pattern (denoting high stiffness) in the near field of the FOV, appearance of the surrounding tissue, FOV placement, and ROI placement for the maximum (Emax), minimum (Emin), mean (Emean), and SD (ESD) of Young modulus elasticity measurements. Using ROC analysis, we compared the performance of Emax, Emean, and ESD in diagnosing malignancy on low- and high-quality images on the basis of consensus (i.e., majority) scores for each individual quality parameter as well as two models combining a few of the quality parameters. RESULTS. Three quality parameters (B-mode visualization of the lesion, presence of a near-field red pattern, and the appearance of the surrounding tissue) showed moderate-to-substantial interobserver agreement. SWE images were considered high quality (n = 167) if both B-mode visualization and near-field red pattern received a consensus score of 1, and they were considered low quality (n = 114) if either parameter received a consensus score of 0. High-quality images had a statistically higher AUC value than low-quality images when Emax (p < .001), Emean (p = .002), and ESD (p < .001) were used as classifiers of malignancy. CONCLUSION. Quality parameters can support radiologists who are performing and interpreting breast SWE images. These quality parameters have the potential to improve the accuracy of SWE in differentiating malignant from benign breast lesions.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y EspecificidadRESUMEN
BACKGROUND. Lumbar spine MRI is associated with a high prevalence of interpretive errors by radiologists. Treating physicians can obtain symptom information, correlate symptoms with MRI findings, and distinguish presumptive pain generators from incidental abnormalities. OBJECTIVE. The purpose of this study was to capture symptom information using a patient questionnaire, review lumbar spine MRI examinations with and without symptom information, diagnose pain generators, and compare MRI diagnoses with clinical reference diagnoses. METHODS. In this prospective study, 120 participants (70 men and 50 women; median age, 64 years; interquartile range, 49.5-74 years) were recruited from patients referred for lumbar spine injections between February and June 2019. Participants completed electronic questionnaires regarding their symptoms before receiving the injections. For three research arms, six radiologists diagnosed pain generators in MRI studies reviewed with symptom information from questionnaires, MRI studies reviewed without symptom information, and MRI reports. Interreading agreement was analyzed. Blinded to the questionnaire results, the radiologists who performed injections obtained patient histories, correlated symptoms with MRI findings, and diagnosed presumptive pain generators. These diagnoses served as clinical reference standards. Pain generators were categorized by type, level, and side and were compared using kappa statistics. Diagnostic certainty was recorded using numeric values (0-100) and was compared using Wilcoxon rank-sum test RESULTS. When compared with the reference standard, agreement for the type, level, and side of pain generator was almost perfect in MRI examinations reviewed with symptom information (κ = 0.82-0.90), fair to moderate in MRI examinations reviewed without symptom information (κ = 0.28-0.51) (all p < .001), and fair to moderate in MRI reports (κ = 0.27-0.45) (all p < .001). Interreading agreement was almost perfect when MRI examinations were reviewed with symptom information (κ = 0.82-0.90) but was only moderate without symptom information (κ = 0.42-0.56) (all p < .001). Diagnostic certainty levels were highest for radiologists performing injections (mean [± SD], 90.0 ± 9.9) and were significantly higher for MRI review with symptom information versus without symptom information (means for reading 1, 84.6 ± 13.1 vs 62.9 ± 20.7; p < .001). CONCLUSION. In lumbar spine MRI, presumptive pain generators diagnosed using symptom information from electronic questionnaires showed almost perfect agreement with pain generators diagnosed using symptom information from direct patient interviews. CLINICAL IMPACT. Patient-reported symptom information from a brief questionnaire can be correlated with MRI findings to distinguish presumptive pain generators from incidental abnormalities.
Asunto(s)
Dolor de la Región Lumbar/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética , Cuestionario de Salud del Paciente , Anciano , Femenino , Humanos , Dolor de la Región Lumbar/etiología , Masculino , Persona de Mediana Edad , Estudios ProspectivosRESUMEN
BACKGROUND AND PURPOSE: Lumbar spine MRI can help guide the choice of corticosteroid injection in pain management. We investigated whether patient-reported symptom information from a questionnaire could improve agreement in the choice of type, level, and side of injection. MATERIALS AND METHODS: In this prospective observational study, 120 patients (median age 64, 70 men) were recruited from patients referred for pain management. After informed consent, they completed electronic questionnaires that obtained symptom information for later use during MRI reviews. In 3 research arms, 6 radiologists chose injections that would ideally deliver corticosteroid to the presumed sources of pain in (1) MRI studies reviewed with symptom information from questionnaires, (2) MRI studies reviewed without symptom information, and (3) MRI reports. Blinded to questionnaire results, radiologists providing clinical care and interviewing patients chose ideal therapeutic injections to establish reference standards. Injections were categorized by type, level, and side and compared using percent agreement and kappa statistics. Interreading agreement was analyzed. RESULTS: Compared to the reference standard, kappa agreements for injection types, levels, and sides were almost perfect when MRIs were reviewed knowing symptoms (0.85-0.93), fair without symptoms (0.23-0.35) (all P < .001) and fair in MRI reports (0.24-0.36) (all P < .001). Interreading kappa agreements were almost perfect knowing symptoms (0.82-0.90), but only moderate without symptoms (0.42-0.49) (all P < .001). CONCLUSIONS: Radiologists reviewing lumbar spine MRI converged on the type, level, and side of ideal therapeutic injection whether they obtained symptom information from direct patient interview or electronic questionnaire. Observer agreement was significantly lower without symptom information.
Asunto(s)
Vértebras Lumbares , Manejo del Dolor , Humanos , Vértebras Lumbares/diagnóstico por imagen , Región Lumbosacra , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios ProspectivosRESUMEN
Background Performance metrics with digital breast tomosynthesis (DBT) are based on early experiences. There is limited research on whether the benefits of DBT are sustained. Purpose To determine whether improved screening performance metrics with DBT are sustained over time at the population level and after the first screening round at the individual level. Materials and Methods A retrospective review was conducted of screening mammograms that had been obtained before DBT implementation (March 2008 to February 2011, two-dimensional digital mammography [DM] group) and for 5 years after implementation (January 2013 to December 2017, DBT1-DBT5 groups, respectively). Patients who underwent DBT were also categorized according to the number of previous DBT examinations they had undergone. Performance metrics were compared between DM and DBT groups and between patients with no previous DBT examinations and those with at least one prior DBT examination by using multivariable logistic regression models. Results The DM group consisted of 99 582 DM examinations in 55 086 women (mean age, 57.3 years ± 11.6 [standard deviation]). The DBT group consisted of 205 048 examinations in 76 276 women (mean age, 58.2 years ± 11.2). There were no differences in the cancer detection rate (CDR) between DM and DBT groups (4.6-5.8 per 1000 examinations, P = .08 to P = .95). The highest CDR was observed with a woman's first DBT examination (6.1 per 1000 examinations vs 4.4-5.7 per 1000 examinations with at least one prior DBT examination, P = .001 to P = .054). Compared with the DM group, the DBT1 group had a lower abnormal interpretation rate (AIR) (adjusted odds ratio [AOR], 0.85; P < .001), which remained reduced in the DBT2, DBT3, and DBT5 groups (P < .001 to P = .02). The reduction in AIR was also sustained after the first examination (P < .001 to P = .002). Compared with the DM group, the DBT1 group had a higher specificity (AOR, 1.20; P < .001), which remained increased in DBT2, DBT3, and DBT5 groups (P < .001 to P = .004). The increase in specificity was also sustained after the first examination (P < .001 to P = .01). Conclusion The benefits of reduced false-positive examinations and higher specificity with screening tomosynthesis were sustained after the first screening round at the individual level. © RSNA, 2020 See also the editorial by Taourel in this issue.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Estados UnidosRESUMEN
OBJECTIVE. The purpose of this study was to evaluate the frequency and cancer yield of BI-RADS category 3 lesions in baseline versus nonbaseline (those with at least one prior) MRI screening examinations. MATERIALS AND METHODS. Consecutive MRI screening examinations performed from 2011 through 2015 were reviewed. Pearson and Wilcoxon tests were used to examine differences in age, breast density, screening indication, background parenchymal enhancement, and cancer yield between baseline and nonbaseline MRI BI-RADS category 3 assessments. Multivariate logistic regression models based on generalized estimating equations were used to assess the odds of receiving a BI-RADS 3 assessment as a function of the variables. RESULTS. Of 6672 MRI screening examinations of 3214 patients, 202 examinations (3%) were assessed BI-RADS category 3. Among baseline examinations, 8% (82/983) were assessed BI-RADS 3, compared with 2% (120/5689) of nonbaseline examinations (p < 0.001). Among the total BI-RADS 3 examinations, 6% (13/202) yielded malignancy of the lesion that had been assessed BI-RADS 3; 12 of 13 cancers were stage 0 or I at diagnosis. The cancer yield of BI-RADS 3 at baseline examinations was 2% (2/82), compared with 9% (11/120) for nonbaseline examinations (p = 0.056). Ten of 13 examinations were upgraded at or before 6-month follow-up MRI. CONCLUSION. Baseline screening breast MRI examinations are associated with a significantly higher rate of BI-RADS category 3 assessments than are nonbaseline examinations. Most cancers diagnosed at follow-up of BI-RADS 3 lesions are in an early stage and are diagnosed at or before the 6-month follow-up examination. When used judiciously, short-interval follow-up MRI is an appropriate method for identifying early-stage breast cancer while avoiding unnecessary biopsies with benign findings.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Densidad de la Mama , Neoplasias de la Mama/patología , Medios de Contraste , Diagnóstico Diferencial , Detección Precoz del Cáncer , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Tamizaje Masivo , Persona de Mediana Edad , Estudios RetrospectivosRESUMEN
BACKGROUND: Postmenopausal obese women demonstrate an elevated breast cancer risk and experience increased breast cancer morbidity and mortality compared with women with a normal body mass index (BMI). However, to the authors' knowledge, prior studies have yielded inconclusive results regarding the effects of obesity on mammography screening adherence. Using national cross-sectional survey data, the objective of the current study was to assess the current association between increasing BMI and use of mammography screening. METHODS: Cross-sectional survey data from the 2016 Behavioral Risk Factor Surveillance System, a state-based national telephone survey of noninstitutionalized adults in the United States, was used to identify the association between mammography screening use and increasing incremental BMI categories, including normal (18.5-24.9 kg/m2 ), overweight (25-29.9 kg/m2 ), obese class I (30-34.9 kg/m2 ), obese class II (35-39.9 kg/m2 ), and obese class III (>40 kg/m2 ), with adjustments for potential confounders. A multivariable logistic regression model was used to evaluate the effect of each BMI category on self-reported mammography use, using unadjusted and adjusted odds ratios. Effect modification by race/ethnicity was determined by testing interaction terms using Wald tests. RESULTS: Of 116,343 survey respondents, 33.5% (38,984 respondents) had a normal BMI, 32.6% (37,969 respondents) were overweight, 19.3% (22,416 respondents) were classified as obese class I, 8.4% (9791 respondents) were classified as obese class II, and 6.2% (7183 respondents) were classified as obese class III. There was no statistically significant difference (P < .05) observed with regard to mammography use between women with a normal BMI and obese women from each obese class (classes I-III) when compared individually. There also was no evidence of effect modification by race (P = .53). CONCLUSIONS: In contrast to prior reports, the results of the current study demonstrated no association between obesity and adherence to screening mammography. These findings may relate to the increasing social acceptance of obesity among women from all racial/ethnic groups and the removal of weight-related facility-level barriers over time.