Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Card Surg ; 34(10): 1106-1109, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31269291

RESUMEN

Coronary artery fistula is a rare congenital or acquired anomaly. It involves an abnormal connection between the coronary artery and the cardiac chambers or the large thoracic vessels. In some cases, the feeding coronary artery can become extremely dilated. The treatment includes a transcatheter or a surgical intervention depending on the complexity of the anomaly. We present the surgical treatment of the coronary artery to coronary sinus fistula, which includes the complete exclusion of the giant right coronary artery and followed by triple bypass surgery.


Asunto(s)
Aneurisma Coronario/cirugía , Seno Coronario/anomalías , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Fístula Vascular/complicaciones , Procedimientos Quirúrgicos Vasculares/métodos , Aneurisma Coronario/diagnóstico , Aneurisma Coronario/etiología , Angiografía Coronaria , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Fístula Vascular/diagnóstico , Fístula Vascular/cirugía
2.
Eur J Cardiothorac Surg ; 61(5): 1068-1075, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-34915555

RESUMEN

OBJECTIVES: The German Registry of Acute Aortic Dissection Type A (GERAADA) on-line score calculator to predict 30-day mortality in patients undergoing surgery for acute type A aortic dissection (ATAAD) was recently launched. Using the European System for Cardiac Operative Risk Evaluation II (EuroSCORE II), it is also possible to predict operative mortality for the same type of surgery. The goal of our study was to validate the prediction accuracy of these 2 on-line risk prediction models. METHODS: Prospectively collected data for EuroSCORE II risk factors as well as all data for GERAADA scoring were extracted from an institutional database for 147 patients who underwent surgery for ATAAD between April 2018 and April 2021. The discriminative power was assessed using area under the receiver operating characteristic curve. The calibration of the models was tested by the Hosmer-Lemeshow statistics and by using the observed-to-expected (O/E) mortality ratio with the 95% confidence interval. RESULTS: The observed operative mortality was 14.3%. The mean predicted mortality rates for the GERAADA score and the EuroSCORE II were 15.6% and 10.6%, respectively. The EuroSCORE II discriminative power (area under the curve = 0.799) significantly outperformed the discriminatory power of the GERAADA score (area under the curve = 0.550). The Hosmer-Lemeshow statistics confirmed good calibration for both models (P-values of 0.49 and 0.29 for the GERAADA score and the EuroSCORE II, respectively). The O/E mortality ratio certified good calibration for both scores [GERAADA score (O/E ratio of 0.93, 95% confidence interval: 0.53-1.33); EuroSCORE II (O/E ratio of 1.35, 95% confidence interval: 0.77-1.93)]. CONCLUSIONS: The EuroSCORE II has better discriminative power for predicting operative mortality in ATAAD surgery than the GERAADA score. Both scores confirmed good calibration ability.


Asunto(s)
Disección Aórtica , Disección Aórtica/cirugía , Corazón , Mortalidad Hospitalaria , Humanos , Curva ROC , Sistema de Registros , Medición de Riesgo , Factores de Riesgo
3.
Ann Thorac Surg ; 86(4): 1386-7, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18805211

RESUMEN

The residual aortic prosthetic valve paravalvular space beneath the left coronary artery is very difficult and risky to repair. To improve visualization of this area, we transected the ascending aorta and mobilized both the aortic root and the left coronary artery from the surrounding tissue. Subsequently, we retracted the left coronary artery aside and pulled the posterior aortic root upwards. This maneuver has provided enough space for the safe placement of stitches and the closure of the paraprosthetic defect in this very delicate area.


Asunto(s)
Aorta Torácica/cirugía , Bioprótesis , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Técnicas de Sutura , Válvula Aórtica/microbiología , Válvula Aórtica/cirugía , Ecocardiografía Transesofágica , Endocarditis Bacteriana/complicaciones , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Persona de Mediana Edad , Válvula Mitral/microbiología , Válvula Mitral/cirugía , Ajuste de Prótesis/métodos , Medición de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA