Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Sensors (Basel) ; 21(10)2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-34064984

RESUMEN

Coatings or films are applied to a substrate for several applications, such as waterproofing, corrosion resistance, adhesion performance, cosmetic effects, and optical coatings. When applying a coating to a substrate, it is vital to monitor the coating thickness during the coating process to achieve a product to the desired specification via real time production control. There are several different coating thickness measurement methods that can be used, either in-line or off-line, which can determine the coating thickness relative to the material of the coating and the substrate. In-line coating thickness measurement methods are often very difficult to design and implement due to the nature of the harsh environmental conditions of typical production processes and the speed at which the process is run. This paper addresses the current and novel coating thickness methodologies for application to chromium coatings on a ferro-magnetic steel substrate with their advantages and limitations regarding in-line measurement. The most common in-line coating thickness measurement method utilized within the steel packaging industry is the X-ray Fluorescence (XRF) method, but these systems can become costly when implemented for a wide packaging product and pose health and safety concerns due to its ionizing radiation. As technology advances, nanometer-scale coatings are becoming more common, and here three methods are highlighted, which have been used extensively in other industries (with several variants in their design) which can potentially measure coatings of nanometer thickness in a production line, precisely, safely, and do so in a non-contact and non-destructive manner. These methods are optical reflectometry, ellipsometry and interferometry.

2.
Nanotechnology ; 25(34): 345202, 2014 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-25100801

RESUMEN

Organic light emitting diodes (OLEDs) incorporating grid transparent conducting electrodes (TCEs) with wide grid line spacing suffer from an inability to transfer charge carriers across the gaps in the grids to promote light emission in these areas. High luminance OLEDs fabricated using a hybrid TCE composed of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS PH1000) or regioregular poly(3-hexylthiophene)-wrapped semiconducting single-walled carbon nanotubes (rrP3HT-SWCNT) in combination with a nanometre thin gold grid are reported here. OLEDs fabricated using the hybrid gold grid/PH1000 TCE have a luminance of 18 000 cd m(-2) at 9 V; the same as the reference indium tin oxide (ITO) OLED. The gold grid/rrP3HT-SWCNT OLEDs have a lower luminance of 8260 cd m(-2) at 9 V, which is likely due to a rougher rrP3HT-SWCNT surface. These results demonstrate that the hybrid gold grid/PH1000 TCE is a promising replacement for ITO in future plastic electronics applications including OLEDs and organic photovoltaics. For applications where surface roughness is not critical, e.g. electrochromic devices or discharge of static electricity, the gold grid/rrP3HT-SWCNT hybrid TCE can be employed.

3.
J Nanosci Nanotechnol ; 10(1): 497-501, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20352882

RESUMEN

The shape and dimensions of an atomic force microscope tip are crucial factors to obtain high resolution images at the nanoscale. When measuring samples with narrow trenches, inclined sidewalls near 90 degrees or nanoscaled structures, standard silicon atomic force microscopy (AFM) tips do not provide satisfactory results. We have combined deep reactive ion etching (DRIE) and focused ion beam (FIB) lithography techniques in order to produce probes with sharp rocket-shaped silicon AFM tips for high resolution imaging. The cantilevers were shaped and the bulk micromachining was performed using the same DRIE equipment. To improve the tip aspect ratio we used FIB nanolithography technique. The tips were tested on narrow silicon trenches and over biological samples showing a better resolution when compared with standard AFM tips, which enables nanocharacterization and nanometrology of high-aspect-ratio structures and nanoscaled biological elements to be completed, and provides an alternative to commercial high aspect ratio AFM tips.


Asunto(s)
Microscopía de Fuerza Atómica/instrumentación , Microscopía de Fuerza Atómica/métodos , Nanotecnología/métodos , Línea Celular Tumoral , Humanos , Microscopía Electrónica de Rastreo , Osteoblastos/ultraestructura , Polimetil Metacrilato/química , Silicio/química
4.
J Nanosci Nanotechnol ; 10(1): 413-20, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20352871

RESUMEN

The synthesis and self-assembled monolayer (SAM) formation of a calix[4]crown-5 derivative are reported. Several techniques, including electrochemistry, atomic force microscopy (AFM), Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and contact angle measurements have been applied to characterise the monolayer film designed for chemical sensor applications. The recognition properties of this SAM for metal cations has been investigated using impedance spectroscopy (IS) showing an electrochemical response proportional to calcium ion concentration in the range from 10(-7) M to 10(-2) M. This response is related to microscopic changes at the gold surface induced by selective binding by the immobilised calixarene.


Asunto(s)
Calcio/análisis , Calixarenos/química , Éteres Corona/química , Nanoestructuras/química , Nanotecnología/métodos , Impedancia Eléctrica , Microscopía de Fuerza Atómica
5.
Small ; 5(5): 614-20, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19263425

RESUMEN

A technique for producing micrometer-scale structures over large, nonplanar chitosan surfaces is described. The technique makes use of the rheological characteristics (deformability) of the chitosan to create freestanding, three-dimensional scaffolds with controlled shapes, incorporating defined microtopography. The results of an investigation into the technical limits of molding different combinations of shapes and microtopographies are presented, highlighting the versatility of the technique when used irrespectively with inorganic or delicate organic moulds. The final, replicated scaffolds presented here are patterned with arrays of one-micrometer-tall microstructures over large areas. Structural integrity is characterized by the measurement of structural degradation. Human umbilical vein endothelial cells cultured on a tubular scaffold show that early cell growth is conditioned by the microtopography and indicate possible uses for the structures in biomedical applications. For those applications requiring improved chemical and mechanical resistance, the structures can be replicated in poly(dimethyl siloxane).


Asunto(s)
Materiales Biocompatibles/química , Técnicas de Cultivo de Célula/métodos , Quitosano/química , Células Endoteliales/citología , Células Endoteliales/fisiología , Nanoestructuras/química , Nanoestructuras/ultraestructura , Adhesión Celular , Proliferación Celular , Células Cultivadas , Cristalización/métodos , Humanos , Ensayo de Materiales , Nanotecnología/métodos , Tamaño de la Partícula , Propiedades de Superficie , Ingeniería de Tejidos/métodos
6.
ACS Nano ; 13(6): 6973-6981, 2019 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-31125201

RESUMEN

Hybrid inorganic-in-organic semiconductors are an attractive class of materials for optoelectronic applications. Traditionally, the thicknesses of organic semiconductors are kept below 1 µm due to poor charge transport in such systems. However, recent work suggests that charge carriers in such organic semiconductors can be transported over centimeter length scales opposing this view. In this work, a unipolar X-ray photoconductor based on a bulk heterojunction architecture, consisting of poly(3-hexylthiophene), a C70 derivative, and high atomic number bismuth oxide nanoparticles operating in the 0.1-1 mm thickness regime is demonstrated, having a high sensitivity of ∼160 µC mGy-1 cm-3. The high performance enabled by hole drift lengths approaching a millimeter facilitates a device architecture allowing a high fraction of the incident X-rays to be attenuated. An X-ray imager is demonstrated with sufficient resolution for security applications such as portable baggage screening at border crossings and public events and scalable medical applications.

7.
Nanoscale ; 11(31): 14734-14741, 2019 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-31348471

RESUMEN

Graphene-based carbon sponges can be used in different applications in a large number of fields including microelectronics, energy harvesting and storage, antimicrobial activity and environmental remediation. The functionality and scope of their applications can be broadened considerably by the introduction of metallic nanoparticles into the carbon matrix during preparation or post-synthesis. Here, we report on the use of X-ray micro-computed tomography (CT) as a method of imaging graphene sponges after the uptake of metal (silver and iron) nanoparticles. The technique can be used to visualize the inner structure of the graphene sponge in 3D in a non-destructive fashion by providing information on the nanoparticles deposited on the sponge surfaces, both internal and external. Other deposited materials can be imaged in a similar manner providing they return a high enough contrast to the carbon microstructure, which is facilitated by the low atomic mass of carbon.

8.
RSC Adv ; 8(65): 37540-37549, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35557804

RESUMEN

Graphene is a desirable material for next generation technology. However, producing high yields of single-layer flakes with industrially applicable methods is currently limited. We introduce a combined process for the reduction of graphene oxide (GO) via vitamin C (ascorbic acid) and thermal annealing at temperatures of <150 °C for times of <10 minutes, resulting in electrically conducting thin films with sheet resistances reducing by 8 orders of magnitude to as low as ∼1.3 kΩ â–¡-1, suitable for microelectronics, display technology and optoelectronic applications. The in-depth physicochemical characterisation of the products at different stages of GO preparation and reduction allows for further understanding of the process and demonstrates the suitability for industrial production methodologies due to an environmentally-friendly reducing agent, solution processability and no requirement for high temperatures. The presence of the vitamin C lowers the temperature required to thermally reduce the GO into an electrically conducting thin film, making the technique suitable for thermally sensitive substrates, such as low melting point polymers. Simultaneous spray coating and reduction of GO allows for large area deposition of conductive coatings without sacrificing solution processability, often lost through particle agglomeration, making it compatible with industrial processes, and applicable to, for example, the production of sensors, energy devices and flexible conductive electrodes for touchscreens.

9.
Small ; 3(5): 871-9, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17394283

RESUMEN

MG63 cells cultured on regular arrays of point microstructures (posts and holes) are shown to preferentially align at certain angles to the pattern of the structures, at 0 degrees, 30 degrees, and 45 degrees in particular. The effect is found to be more pronounced for post rather than hole structures (although no significant difference is found for the angles the cells make to the holes or posts) and is thought to be due to the fact that the cells use the posts as anchorage points to hold themselves to the surface. It is also shown that cells preferentially align with the structures depending on the dimensions of the structures and the distance between neighboring structures. This is important when designing structured surfaces for cell-surface interaction studies for materials to be used in, for example, drug delivery or tissue engineering.


Asunto(s)
Cristalización/métodos , Nanoestructuras/química , Nanoestructuras/ultraestructura , Osteoblastos/citología , Osteoblastos/fisiología , Polimetil Metacrilato/química , Ingeniería de Tejidos/métodos , Adhesión Celular , Técnicas de Cultivo de Célula/métodos , Línea Celular , Polaridad Celular , Humanos , Sustancias Macromoleculares/química , Ensayo de Materiales , Conformación Molecular , Nanotecnología/métodos , Tamaño de la Partícula , Propiedades de Superficie
10.
J Nanosci Nanotechnol ; 7(12): 4588-94, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18283849

RESUMEN

Biomedical devices are moving towards the incorporation of nanostructures to investigate the interactions of biological species with such topological surfaces found in nature. Good optical transparency and sealing properties, low fabrication cost, fast design realization times, and biocompatibility make polymers excellent candidates for the production of surfaces containing such nanometric structures. In this work, a method for the production of nanostructures in free-standing sheets of different thermoplastic polymers is presented, with a view to using these substrates in biomedical cell-surface applications where optical microscopy techniques are required. The process conditions for the production of these structures in poly(methyl methacrylate), poly(ethylene naphthalate), poly(lactic acid), poly(styrene), and poly(ethyl ether ketone) are given. The fabrication method used is based on a modified nanoimprint lithography (NIL) technique using silicon based moulds, fabricated via reactive ion etching or focused ion beam lithography, to emboss nanostructures into the surface of the biologically compatible thermoplastic polymers. The method presented here is designed to faithfully replicate the nanostructures in the mould while maximising the mould lifetime. Examples of polymer replicas with nanostructures of different topographies are presented in poly(methyl methacrylate), including nanostructures for use in cell-surface interactions and nanostructure-containing microfluidic devices.


Asunto(s)
Nanoestructuras , Polímeros/química , Propiedades de Superficie
11.
J Biomed Mater Res A ; 76(4): 781-7, 2006 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-16345083

RESUMEN

The formation of structures in poly(lactic acid) has been investigated with respect to producing areas of regular, superficial features with dimensions comparable to those of cells or biological macromolecules. Nanoembossing, a novel method of pattern replication in polymers, has been used for the production of features ranging from tens of micrometers, covering areas up to 1 cm(2), down to hundreds of nanometers. Both micro- and nanostructures are faithfully replicated. Contact-angle measurements suggest that positive microstructuring of the polymer (where features protrude from the polymer surface) produces a more hydrophilic surface than negative microstructuring. The ability to structure the surface of the poly(lactic acid), allied to the polymer's postprocessing transparency and proven biocompatibility, means that thin films produced in this way will be useful for bioengineers studying the interaction of micro- and nanodimensioned features with biological specimen, with regard to tissue engineering, for example.


Asunto(s)
Materiales Biocompatibles , Ácido Láctico , Polímeros , Línea Celular , Nanotecnología , Poliésteres
12.
Nanoscale ; 7(34): 14241-7, 2015 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-26256946

RESUMEN

We report a ZnO interfacial layer based on an environmentally friendly aqueous precursor for organic photovoltaics. Inverted PCDTBT devices based on this precursor show power conversion efficiencies of 6.8-7%. Unencapsulated devices stored in air display prolonged lifetimes extending over 200 hours with less than 20% drop in efficiency compared to devices based on the standard architecture.

14.
Adv Mater ; 26(13): 2078-83, 2014 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-24382671

RESUMEN

Solution processed core-shell nano-structures of metal oxide-reduced graphene oxide (RGO) are used as improved electron transport layers (ETL), leading to an enhancement in photocurrent charge transport in PCDTBT:PC70 BM for both single cell and module photovoltaic devices. As a result, the power conversion efficiency for the devices with RGO-metal oxides for ETL increases 8% in single cells and 20% in module devices.

15.
Phys Med Biol ; 58(13): 4471-82, 2013 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-23760010

RESUMEN

Recently, a new family of low-cost x-radiation detectors have been developed, based on semiconducting polymer diodes, which are easy to process, mechanically flexible, relatively inexpensive, and able to cover large areas. To test their potential for radiotherapy applications such as beam monitors or dosimeters, as an alternative to the use of solid-state inorganic detectors, we present the direct detection of 6 MV x-rays from a medical linear accelerator using a thick film, semiconducting polymer detector. The diode was subjected to 4 ms pulses of 6 MV x-rays at a rate of 60 Hz, and produces a linear increase in photocurrent with increasing dose rate (from 16.7 to 66.7 mGy s(-1)). The sensitivity of the diode was found to range from 13 to 20 nC mGy(-1) cm(-3), for operating voltages from -50 to -150 V, respectively. The diode response was found to be stable after exposure to doses up to 15 Gy. Testing beyond this dose range was not carried out. Theoretical calculations show that the addition of heavy metallic nanoparticles to polymer films, even at low volume fractions, increases the x-ray sensitivity of the polymer film/nanoparticle composite so that it exceeds that for silicon over a wide range of x-ray energies. The possibility of detecting x-rays with energies relevant to medical oncology applications opens up the potential for these polymer detectors to be used in detection and imaging applications using medical x-ray beams.


Asunto(s)
Aceleradores de Partículas/instrumentación , Polímeros/efectos de la radiación , Radiometría/instrumentación , Semiconductores , Rayos X , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
J Biomed Mater Res A ; 98(2): 229-34, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21548017

RESUMEN

A method for the simultaneous (bio)chemical and topographical patterning of enclosed structures in poly(dimethyl siloxane) (PDMS) is presented. The simultaneous chemical and topography transference uses a water-soluble chitosan sacrificial mold to impart a predefined pattern with micrometric accuracy to a PDMS replica. The method is compared to conventional soft-lithography techniques on planar surfaces. Its functionality is demonstrated by the transference of streptavidin directly to the surface of the three-dimensional PDMS structures as well as indirectly using streptavidin-loaded latex nanoparticles. The streptavidin immobilized on the PDMS is tested for bioactivity by coupling with fluorescently labeled biotin. This proves that the streptavidin is immobilized on the PDMS surface, not in the bulk of the polymer, and is therefore accessible for use as signaling/binding element in micro and bioengineering. The use of a biocompatible polymer and processes enables the technique to be used for the chemical patterning of tissue constructions.


Asunto(s)
Materiales Biocompatibles/química , Andamios del Tejido/química , Biotina/metabolismo , Quitosano/química , Dimetilpolisiloxanos/química , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Estreptavidina/metabolismo , Propiedades de Superficie
17.
ACS Appl Mater Interfaces ; 2(6): 1692-9, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20496869

RESUMEN

Existing inorganic materials for radiation sensors suffer from several drawbacks, including their inability to cover large curved areas, lack of tissue-equivalence, toxicity, and mechanical inflexibility. As an alternative to inorganics, poly(triarylamine) (PTAA) diodes have been evaluated for their suitability for detecting radiation via the direct creation of X-ray induced photocurrents. A single layer of PTAA is deposited on indium tin oxide (ITO) substrates, with top electrodes selected from Al, Au, Ni, and Pd. The choice of metal electrode has a pronounced effect on the performance of the device; there is a direct correlation between the diode rectification factor and the metal-PTAA barrier height. A diode with an Al contact shows the highest quality of rectifying junction, and it produces a high X-ray photocurrent (several nA) that is stable during continuous exposure to 50 kV Mo Kalpha X-radiation over long time scales, combined with a high signal-to-noise ratio with fast response times of less than 0.25 s. Diodes with a low band gap, 'Ohmic' contact, such as ITO/PTAA/Au, show a slow transient response. This result can be explained by the build-up of space charge at the metal-PTAA interface, caused by a high level of charge injection due to X-ray-induced carriers. These data provide new insights into the optimum selection of metals for Schottky contacts on organic materials, with wider applications in light sensors and photovoltaic devices.


Asunto(s)
Polímeros/química , Relación Dosis-Respuesta en la Radiación , Electrodos , Electrónica , Luz , Ensayo de Materiales , Modelos Químicos , Fotoquímica/métodos , Solventes/química , Temperatura , Factores de Tiempo , Compuestos de Estaño/química , Rayos X
18.
J Biomed Mater Res A ; 85(1): 242-7, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17688270

RESUMEN

A technique for imparting micro- and nanostructured topography into the surface of freestanding thin sheets of chitosan is described. Both micro- and nanometric surface structures have been produced using soft lithography. The soft lithography method, based on solvent evaporation, has allowed structures approximately 60 nm tall and approximately 500 x 500 nm(2) to be produced on freestanding approximately 0.5 mm thick sheets of the polymer when cured at 293 K, and structures approximately 400 nm tall and 5 x 5 microm(2) to be produced when cured at 283 K. Nonstructured chitosan thin sheets (approximately 200 microm thick) show excellent optical transmission properties in the visible portion of the electromagnetic spectrum. The structured sheets can be used for applications where optical microscopic analysis is required, such as cell interaction experiments and tissue engineering.


Asunto(s)
Materiales Biocompatibles , Quitosano , Nanotecnología , Materiales Biocompatibles/química , Quitosano/química , Prótesis e Implantes , Espectrofotometría , Ingeniería de Tejidos
19.
Langmuir ; 24(16): 8841-9, 2008 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-18624456

RESUMEN

The combination of the recently introduced soft lithographic technique of inverted microcontact printing (i-muCP) and spin-coated films of polystyrene- block-poly( tert-butyl acrylate) (PS 690- b-P tBA 1210) as a reactive platform is shown to yield a versatile approach for the facile fabrication of topographically structured and chemically patterned biointerfaces with characteristic spacings and distances that cross many orders of magnitude. The shortcomings of conventional muCP in printing of small features with large spacings, due to the collapse of small or high aspect ratio stamp structures, are circumvented in i-muCP by printing reactants using a featureless elastomeric stamp onto a topographically structured reactive polymer film. Prior to molecular transfer, the substrate-supported PS 690- b-P tBA 1210 films were structured by imprint lithography resulting in lateral and vertical feature sizes between >50 microm-150 nm and >1.0 microm-18 nm, respectively. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and water contact angle measurements provided evidence for the absence of surface chemical transformations during the imprinting step. Following the previously established hydrolysis and activation protocol with trifluoroacetic acid and N-hydroxysuccinimide, amino end-functionalized poly(ethylene glycol) (PEG-NH 2), as well as bovine serum albumin and fibronectin as model proteins, were successfully transferred by i-muCP and coupled covalently. As shown, i-muCP yields increased PEG coverages and thus improved performance in suppressing nonspecific adsorption of proteins by exploiting the high local concentrations in the micro- and nanocontacts during molecular transfer. The i-muCP strategy provides access to versatile biointerface platforms patterned across the length scales, as shown for guided cancer cell adhesion, which opens the pathway for systematic cell-surface interaction studies.


Asunto(s)
Acrilatos/química , Poliestirenos/química , Animales , Bovinos , Línea Celular , Microscopía de Fuerza Atómica , Estructura Molecular , Albúmina Sérica Bovina/química
20.
Artículo en Inglés | MEDLINE | ID: mdl-18001902

RESUMEN

There is an unmet medical need for a more reliable and earlier assessment of patients suspected of having a deep vein thrombosis. We describe a novel approach which is developing a highly reliable, accurate, portable and handheld prototype medical diagnostic device to improve radically the speed, accuracy and reliability with which DVT and related blood clotting conditions can be assessed. The device will measure whole blood concentration of D-dimer, a recognized biomarker of increased blood clotting activity, and through innovation in the development of a novel detection, measurement and reporting system, will offer the opportunity to use the test in the point of care setting. The device combines innovation in antibody bio-engineering for high specificity immunoassay-based diagnostics and nano/micro engineered impedimetric analysis electrodes incorporating a biocompatible polymer substrate with development of a disposable microfluidic manifold specifically enabling diagnostics at the point-of-first-contact.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno/análisis , Inmunoensayo/métodos , Trombosis de la Vena/sangre , Especificidad de Anticuerpos , Materiales Biocompatibles/química , Biomarcadores/sangre , Impedancia Eléctrica , Humanos , Inmunoensayo/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Sistemas de Atención de Punto , Polímeros/química , Trombosis de la Vena/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA