1.
Circulation ; 126(10): 1245-55, 2012 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-22899774

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear. METHODS AND RESULTS: Eighty-three patients underwent transfemoral (Medtronic CoreValve [MCV(TF)], n=32; Edwards Sapien [ES(TF)], n=26) and transapical (ES(TA): n=25) TAVI. Serial transcranial Doppler examinations before, during, and 3 months after TAVI were used to identify high-intensity transient signals (HITS) as a surrogate for microembolization. Procedural HITS were detected in all patients, predominantly during manipulation of the calcified aortic valve while stent valves were being positioned and implanted. The balloon-expandable ES prosthesis caused significantly more HITS (mean [95% CI]) during positioning (ES(TF), 259.9 [184.8-334.9]; ES(TA), 206.1[162.5-249.7]; MCV(TF), 78.5 [25.3-131.6]; P<0.001) and the self-expandable MCV prosthesis during implantation (MCV(TF), 397.1 [302.1-492.2]; ES(TF), 88.2 [70.2-106.3]; ES(TA), 110.7 [82.0-139.3]; P<0.001). Overall, there were no significant differences between transfemoral and transapical TAVI or between the MCV and ES prostheses. No HITS were detected at baseline or 3-month follow-up. There was 1 major procedural stroke that resulted in death and 1 minor procedural stroke with full recovery at 3-month follow-up in the MCV group. CONCLUSIONS: Procedural HITS were detected by transcranial Doppler in all patients. Although no difference was observed between the transfemoral and the transapical approach with the balloon-expandable ES stent valve, transfemoral TAVI with the self-expandable MCV prosthesis resulted in the greatest number of HITS, predominantly during implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Complicaciones Intraoperatorias/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/epidemiología , Calcinosis/epidemiología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Comorbilidad , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Complicaciones Intraoperatorias/epidemiología , Masculino , Placa Aterosclerótica/epidemiología , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/epidemiología , Ultrasonografía Doppler Transcraneal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA