Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 233
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
2.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
3.
Eur Heart J ; 44(45): 4771-4780, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37622660

RESUMEN

Imaging plays an integral role in all aspects of managing heart disease and cardiac imaging is a core competency of cardiologists. The adequate delivery of cardiac imaging services requires expertise in both imaging methodology-with specific adaptations to imaging of the heart-as well as intricate knowledge of heart disease. The European Society of Cardiology (ESC) and the European Association of Cardiovascular Imaging have developed and implemented a successful education and certification programme for all cardiac imaging modalities. This programme equips cardiologists to provide high quality competency-based cardiac imaging services ensuring they are adequately trained and competent in the entire process of cardiac imaging, from the clinical indication via selecting the best imaging test to answer the clinical question, to image acquisition, analysis, interpretation, storage, repository, and results dissemination. This statement emphasizes the need for competency-based cardiac imaging delivery which is key to optimal, effective and efficient, patient care.


Asunto(s)
Cardiología , Enfermería Cardiovascular , Cardiopatías , Insuficiencia Cardíaca , Humanos , Corazón
4.
Radiology ; 306(1): 112-121, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36098639

RESUMEN

Background Patients with mitral valve prolapse (MVP) may develop adverse outcomes even in the absence of mitral regurgitation or left ventricular (LV) dysfunction. Purpose To investigate the prognostic value of mitral annulus disjunction (MAD) and myocardial fibrosis at late gadolinium enhancement (LGE) cardiac MRI in patients with MVP without moderate-to-severe mitral regurgitation or LV dysfunction. Materials and Methods In this longitudinal retrospective study, 118 144 cardiac MRI studies were evaluated between October 2007 and June 2020 at 15 European tertiary medical centers. Follow-up was from the date of cardiac MRI examination to June 2020; the minimum and maximum follow-up intervals were 6 months and 156 months, respectively. Patients were excluded if at least one of the following conditions was present: cardiomyopathy, LV ejection fraction less than 40%, ischemic heart disease, congenital heart disease, inflammatory heart disease, moderate or worse mitral regurgitation, participation in competitive sport, or electrocardiogram suggestive of channelopathies. In the remainder, cardiac MRI studies were reanalyzed, and patients were included if they were aged 18 years or older, MVP was diagnosed at cardiac MRI, and clinical information and electrocardiogram monitoring were available within 3 months from cardiac MRI examination. The end point was a composite of adverse outcomes: sustained ventricular tachycardia (VT), sudden cardiac death (SCD), or unexplained syncope. Multivariable Cox regression analysis was performed. Results A total of 474 patients (mean age, 47 years ± 16 [SD]; 244 women) were included. Over a median follow-up of 3.3 years, 18 patients (4%) reached the study end point. LGE presence (hazard ratio, 4.2 [95% CI: 1.5, 11.9]; P = .006) and extent (hazard ratio, 1.2 per 1% increase [95% CI: 1.1, 1.4]; P = .006), but not MAD presence (P = .89), were associated with clinical outcome. LGE presence had incremental prognostic value over MVP severity and sustained VT and aborted SCD at baseline (area under the receiver operating characteristic curve, 0.70 vs 0.62; P = .03). Conclusion In contrast to mitral annulus disjunction, myocardial fibrosis determined according to late gadolinium enhancement at cardiac MRI was associated with adverse outcome in patients with mitral valve prolapse without moderate-to-severe mitral regurgitation or left ventricular dysfunction. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Gerber in this issue.


Asunto(s)
Cardiomiopatías , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Prolapso de la Válvula Mitral/complicaciones , Estudios Retrospectivos , Medios de Contraste , Gadolinio , Válvula Mitral , Imagen por Resonancia Magnética , Fibrosis , Muerte Súbita Cardíaca
5.
J Card Fail ; 29(9): 1261-1272, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37150503

RESUMEN

BACKGROUND: Right heart failure (RHF) is associated with a dismal prognosis in patients with pulmonary hypertension (PH). Exercise right heart catheterization may unmask right heart maladaptation as a sign of RHF. We sought to (1) define the normal limits of right atrial pressure (RAP) increase during exercise; (2) describe the right heart adaptation to exercise in PH owing to heart failure with preserved ejection fraction (PH-HFpEF) and in pulmonary arterial hypertension (PAH); and (3) identify the factors associated with right heart maladaptation during exercise. METHODS AND RESULTS: We analyzed rest and exercise right heart catheterization from patients with PH-HFpEF and PAH. Right heart adaptation was described by absolute or cardiac output (CO)-normalized changes of RAP during exercise. Individuals with noncardiac dyspnea (NCD) served to define abnormal RAP responses (>97.5th percentile). Thirty patients with PH-HFpEF, 30 patients with PAH, and 21 patients with NCD were included. PH-HFpEF were older than PAH, with more cardiovascular comorbidities, and a higher prevalence of severe tricuspid regurgitation (P < .05). The upper limit of normal for peak RAP and RAP/CO slope in NCD were >12 mm Hg and ≥1.30 mm Hg/L/min, respectively. PH-HFpEF had higher peak RAP and RAP/CO slope than PAH (20 mm Hg [16-24 mm Hg] vs 12 mm Hg [9-19 mm Hg] and 3.47 mm Hg/L/min [2.02-6.19 mm Hg/L/min] vs 1.90 mm Hg/L/min [1.01-4.29 mm Hg/L/min], P < .05). A higher proportion of PH-HFpEF had RAP/CO slope and peak RAP above normal (P < .001). Estimated stressed blood volume at peak exercise was higher in PH-HFpEF than PAH (P < .05). In the whole PH cohort, the RAP/CO slope was associated with age, the rate of increase in estimated stressed blood volume during exercise, severe tricuspid regurgitation, and right atrial dilation. CONCLUSIONS: Patients with PH-HFpEF display a steeper increase of RAP during exercise than those with PAH. Preload-mediated mechanisms may play a role in the development of exercise-induced RHF.


Asunto(s)
Insuficiencia Cardíaca , Hipertensión Pulmonar , Enfermedades no Transmisibles , Insuficiencia de la Válvula Tricúspide , Humanos , Hipertensión Pulmonar/diagnóstico , Volumen Sistólico/fisiología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/complicaciones , Hemodinámica , Cateterismo Cardíaco , Disnea , Prueba de Esfuerzo , Tolerancia al Ejercicio
6.
J Cardiovasc Magn Reson ; 25(1): 10, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36793062

RESUMEN

BACKGROUND: The use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images. METHODS: LA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking. RESULTS: Compared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias - 13 ml; LOA = + 11, - 37 ml; LAVmax i: bias - 7 ml/m2; LOA = + 7, - 21 ml/m2; LAVmin; bias - 10 ml, LOA: + 9, - 28 ml; LAVmin i: bias - 5 ml/m2, LOA: + 5, - 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, - 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, - 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, - 6 ml/m2; LAVmin: bias - 2 ml; LOA: + 7, - 10 ml; LAVmin i: bias - 1 ml/m2; LOA: + 3, - 5 ml/m2) and LAEF (bias 2%, LOA: + 11, - 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, - 11%; εe: bias 4%, LOA = 15, - 8%; εa: bias 3%, LOA = 14, - 8%) was significantly higher in standard vs. LA-focused images (p < 0.001). CONCLUSION: LA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.


Asunto(s)
Ecocardiografía , Atrios Cardíacos , Humanos , Valor Predictivo de las Pruebas , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética
7.
Curr Opin Cardiol ; 36(5): 513-524, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34292179

RESUMEN

PURPOSE OF REVIEW: The prognostic impact of tricuspid regurgitation (TR) and the subsequent development of percutaneous procedures targeting the tricuspid valve (TV), has brought to the forefront the role of imaging for the assessment of the forgotten valve. As illustrated in several studies and summarized in this review, currently a multimodality imaging approach is required to understand the pathophysiology of TR, due to the complex TV anatomy and the close relationship between the severity of TR and the extent of the remodeling of the right heart chambers. RECENT FINDINGS: Recently, the advance in the tranhscatheter treatment of the TV has led to a growing interest in the development of dedicated software packages and new display modalities to increase our understanding of the TV. As a consequence, a transversal knowledge of the different imaging modalities is required for contemporary cardiac-imaging physicians. SUMMARY: This review highlights the main features, and the pros and cons of echocardiography, cardiac computed tomography, cardiac magnetic resonance and emerging technologies, as 3D printing and virtual reality, in the assessment of patients with TR.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Técnicas de Imagen Cardíaca , Ecocardiografía , Humanos , Imagen Multimodal , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen
8.
Cardiovasc Ultrasound ; 19(1): 28, 2021 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-34362392

RESUMEN

BACKGROUND: Data about the right ventricular (RV) mechanics adaptation to volume overload in patients with repaired tetralogy of Fallot (rToF) are limited. Accordingly, we sought to assess the mechanics of the functional remodeling occurring in the RV of rToF with severe pulmonary regurgitation. METHODS: We used three-dimensional transthoracic echocardiography (3DTE) to obtain RV data sets from 33 rToF patients and 30 age- and sex- matched controls. A 3D mesh model of the RV was generated, and RV global and regional longitudinal (LS) and circumferential (CS) strain components, and the relative contribution of longitudinal (LEF), radial (REF) and anteroposterior (AEF) wall motion to global RV ejection fraction (RVEF) were computed using the ReVISION method. RESULTS: Corresponding to decreased global RVEF (45 ± 6% vs 55 ± 5%, p < 0.0001), rToF patients demonstrated lower absolute values of LEF (17 ± 4 vs 28 ± 4), REF (20 ± 5 vs 25 ± 4) and AEF (17 ± 5 vs 21 ± 4) than controls (p < 0.01). However, only the relative contribution of LEF to global RVEF (0.39 ± 0.09 vs 0.52 ± 0.05, p < 0.0001) was significantly decreased in rToF, whereas the contribution of REF (0.45 ± 0.08 vs 0.46 ± 0.04, p > 0.05) and AEF (0.38 ± 0.09 vs 0.39 ± 0.04, p > 0.05) to global RVEF was similar to controls. Accordingly, rToF patients showed lower 3D RV global LS (-16.94 ± 2.9 vs -23.22 ± 2.9, p < 0.0001) and CS (-19.79 ± 3.3 vs -22.81 ± 3.5, p < 0.01) than controls. However, looking at the regional RV deformation, the 3D CS was lower in rToF than in controls only in the basal RV free-wall segment (p < 0.01). 3D RV LS was reduced in all RV free-wall segments in rToF (p < 0.0001), but similar to controls in the septum (p > 0.05). CONCLUSIONS: 3DTE allows a quantitative evaluation of the mechanics of global RVEF. In rToF with chronic volume overload, the relative contribution of the longitudinal shortening to global RVEF is affected more than either the radial or the anteroposterior components.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Función Ventricular Derecha
10.
Echocardiography ; 37(11): 1951-1956, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32596833

RESUMEN

Doppler echocardiography assessment of left ventricular (LV) filling pressures at rest and during exercise is the most widely used imaging technique to assess LV diastolic function in clinical practice. However, a sizable number of patients evaluated for suspected LV diastolic function show an inconsistency between the various parameters included in the flowchart recommended by current Doppler echocardiography guidelines and results in an undetermined LV diastolic function. Current three-dimensional echocardiography technology allows obtaining accurate measurements of the left atrial volumes and functions that have been shown to improve the diagnostic accuracy and prognostic value of the algorithms recommended for assessing both LV diastolic dysfunction and heart failure with preserved ejection fraction. Moreover, current software packages used to quantify LV size and function provide also volume-time curves showing the dynamic LV volume change throughout the cardiac cycle. Examining the diastolic part of these curves allows the measurement of several indices of LV filling that have been reported to be useful to differentiate patients with normal LV diastolic function from patients with different degrees of diastolic dysfunction. Finally, several software packages allow to obtain also myocardial deformation parameters from the three-dimensional datasets of both the left atrium and the LV providing additional functional parameters that may be useful to improve the diagnostic yield of three-dimensional echocardiography for the LV diastolic dysfunction. This review summarizes the current applications of three-dimensional echocardiography to assess LV diastolic function.


Asunto(s)
Ecocardiografía Tridimensional , Disfunción Ventricular Izquierda , Diástole , Ecocardiografía Doppler , Humanos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
12.
Cardiovasc Ultrasound ; 16(1): 27, 2018 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-30314517

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a new therapeutic option for high surgical risk patients with mitral regurgitation (MR). Mitral valve (MV) geometry quantification is of paramount importance for success of the procedure and transthoracic 3D echocardiography represents a useful screening tool. Accordingly, we sought to asses MV geometry in patients with functional MR (FMR) that would potentially benefit of TMVR, focusing on the comparison of mitral annulus (MA) geometry between patients with ischemic (IMR) and non ischemic mitral regurgitation (nIMR). METHODS: We retrospectively selected 94 patients with severe FMR: 41 (43,6%) with IMR and 53 (56,4%) with nIMR. 3D MA analysis was performed on dedicated transthoracic 3D data sets using a new, commercially-available software package in two moments of the cardiac cycle (early-diastole and mid-systole). We measured MA dimension and geometry parameters, left atrial and left ventricular volumes. RESULTS: Maximum (MA area 10.7 ± 2.5 cm2 vs 11.6 ± 2.7 cm2, p > 0.05) and the best fit plane MA area (9.9 ± 2.3 cm2 vs 10.7 ± 2.5 cm2, p > 0.05, respectively) were similar between IMR and nIMR. nIMR patients showed larger mid-systolic 3D area (9.8 ± 2.3 cm2 vs 10.8 ± 2.7 cm2, p < 0.05) and perimeter (11.2 ± 1.3 cm vs 11.8 ± 1.5 cm, p < 0.05) with longer and larger leaflets, and wider aorto-mitral angle (135 ± 10° vs 141 ± 11°, p < 0.05). Conversely, the area of MA at the best fit plane did not differ between IMR and nIMR patients (9 ± 1.1 cm2 vs 9.9 ± 1.5 cm2, p > 0.05). CONCLUSIONS: Patients with ischemic and non-ischemic etiology of FMR have similar maximum dimension, yet systolic differences between the two groups should be taken into account to tailor prosthesis's selection. TRIAL REGISTRATION: N.A.


Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Anciano , Estudios de Cohortes , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/fisiopatología , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Resultado del Tratamiento
13.
Europace ; 19(8): 1251-1271, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28444180

RESUMEN

Left bundle branch block (LBBB) results in an altered pattern of left ventricular (LV) activation and subsequent contraction, causing remarkable changes in LV mechanics, perfusion and workload and ultimately leading to pathologic cardiac remodelling. Clinical and diagnostic notions about the LBBB phenomenon had evolved from just an electrocardiographic pattern to a critically important finding affecting diagnostic and clinical management of many patients and adversely influencing their outcomes. Recent advances in imaging techniques significantly improved the assessment of patients with LBBB and provided additional insights into pathophysiological mechanisms of LV remodelling. In the current review we summarized currently available data on the LBBB epidemiology, diagnosis, its impact on clinical management and prognosis, and the role and place of various imaging modalities in assessing cardiac mechanics and perfusion abnormalities, as well as their potential implications for diagnostic and treatment strategies.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Frecuencia Cardíaca , Contracción Miocárdica , Función Ventricular Izquierda , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Animales , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo , Remodelación Ventricular
14.
Europace ; 19(11): 1833-1840, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28025231

RESUMEN

AIMS: To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). METHODS AND RESULTS: In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. CONCLUSION: These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Ecocardiografía Doppler de Pulso , Ecocardiografía Tridimensional , Insuficiencia Cardíaca/terapia , Modelos Cardiovasculares , Contracción Miocárdica , Modelación Específica para el Paciente , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Anciano , Fenómenos Biomecánicos , Terapia de Resincronización Cardíaca/efectos adversos , Dispositivos de Terapia de Resincronización Cardíaca , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Humanos , Hidrodinámica , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Datos Preliminares , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
15.
Cardiovasc Ultrasound ; 15(1): 8, 2017 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-28347344

RESUMEN

Three major mechanisms contribute to right ventricular (RV) pump function: (i) shortening of the longitudinal axis with traction of the tricuspid annulus towards the apex; (ii) inward movement of the RV free wall; (iii) bulging of the interventricular septum into the RV and stretching the free wall over the septum. The relative contribution of the aforementioned mechanisms to RV pump function may change in different pathological conditions.Our aim was to develop a custom method to separately assess the extent of longitudinal, radial and anteroposterior displacement of the RV walls and to quantify their relative contribution to global RV ejection fraction using 3D data sets obtained by echocardiography.Accordingly, we decomposed the movement of the exported RV beutel wall in a vertex based manner. The volumes of the beutels accounting for the RV wall motion in only one direction (either longitudinal, radial, or anteroposterior) were calculated at each time frame using the signed tetrahedron method. Then, the relative contribution of the RV wall motion along the three different directions to global RV ejection fraction was calculated either as the ratio of the given direction's ejection fraction to global ejection fraction and as the frame-by-frame RV volume change (∆V/∆t) along the three motion directions.The ReVISION (Right VentrIcular Separate wall motIon quantificatiON) method may contribute to a better understanding of the pathophysiology of RV mechanical adaptations to different loading conditions and diseases.


Asunto(s)
Ecocardiografía , Imagenología Tridimensional , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha/fisiología , Humanos , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/complicaciones
16.
Echocardiography ; 34(2): 267-278, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28052455

RESUMEN

The use of transcatheter aortic valve replacement (TAVR) for high-risk patients with aortic stenosis has rapidly increased during the past years. Accordingly, more and more patients are referred for a follow-up echocardiographic study after TAVR. However, the echocardiographic evaluation of patients who underwent TAVR places specific demands on echocardiographers. Furthermore, TAVR may be associated with new types of complications, which are frequently unrecognized or underestimated due to lack of familiarity with the normal and pathological appearance of TAVR. Therefore, this review summarizes the echocardiographic parameters describing the structural and functional status of bioprostheses used in TAVR, procedures taking into account their peculiar hemodynamics. We also describe the strengths and the limitations of echocardiography and of other imaging modalities in detecting long-term complications of TAVR (eg, infective endocarditis, thrombosis). The aim of this review was to serve as a guide for a structured echocardiographic follow-up of TAVR patients, as well as for the echocardiographic diagnosis of the procedure-associated complications.


Asunto(s)
Ecocardiografía/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Medición de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
17.
Curr Cardiol Rep ; 18(11): 109, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27628295

RESUMEN

Advances in ultrasound, computer, and electronics technology have permitted three-dimensional echocardiography (3DE) to become a clinically viable imaging modality, with significant impact on patient diagnosis, management, and outcome. Thanks to the inception of a fully sampled matrix transducer for transthoracic and transesophageal probes, 3DE now offers much faster and easier data acquisition, immediate display of anatomy, and the possibility of online quantitative analysis of cardiac chambers and heart valves. The clinical use of transthoracic 3DE has been primarily focused, albeit not exclusively, on the assessment of cardiac chamber volumes and function. Transesophageal 3DE has been applied mostly for assessing heart valve anatomy and function. The advantages of using 3DE to measure cardiac chamber volumes derive from the lack of geometric assumptions about their shape and the avoidance of the apical view foreshortening, which are the main shortcomings of volume calculations from two-dimensional echocardiographic views. Moreover, 3DE offers a unique realistic en face display of heart valves, congenital defects, and surrounding structures allowing a better appreciation of the dynamic functional anatomy of cardiac abnormalities in vivo. Offline quantitation of 3DE data sets has made significant contributions to our mechanistic understanding of normal and diseased heart valves, as well as of their alterations induced by surgical or interventional procedures. As reparative cardiac surgery and transcatheter procedures become more and more popular for treating structural heart disease, transesophageal 3DE has expanded its role as the premier technique for procedure planning, intra-procedural guidance, as well as for checking device function and potential complications after the procedure.


Asunto(s)
Ecocardiografía Tridimensional , Cardiopatías Congénitas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Ecocardiografía Tridimensional/tendencias , Cardiopatías Congénitas/patología , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Aumento de la Imagen , Guías de Práctica Clínica como Asunto
19.
Cardiovasc Ultrasound ; 12: 30, 2014 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-25090937

RESUMEN

BACKGROUND: Cardiac involvement is a relevant clinical finding in systemic sclerosis (SSc) and is associated with poor prognosis. Left atrial (LA) remodeling and/or dysfunction can be an early sign of diastolic dysfunction. Two-dimensional speckle tracking echocardiography (STE) is a novel and promising tool for detecting very early changes in LA myocardial performance. AIM: To assess whether STE strain parameters may detect early alterations in LA function in SSc patients. METHODS: Forty-two SSc patients (Group 1, age 50 ± 14 years, 95% females) without clinical evidence for cardiac involvement and 42 age- and gender-matched control subjects (Group 2, age 49 ± 13 years, 95% females) were evaluated with comprehensive 2D and Doppler echocardiography, including tissue Doppler imaging analysis. Positive peak left atrial longitudinal strain (ϵ pos peak), second positive left atrial longitudinal strain (sec ϵ pos peak), and negative left atrial longitudinal strain (ϵ neg peak) were measured using a 12-segment model for the LA, by commercially available semi-automated 2D speckle-tracking software (EchoPac PC version 108.1.4, GE Healthcare, Horten, Norway). RESULTS: All SSc patients had a normal left ventricular ejection fraction (63.1 ± 4%). SSc patients did not differ from controls in E/A (Group 1 = 1.1 ± 0.4 vs Group 2 = 1.3 ± 0.4, p = .14) or pulmonary arterial systolic pressure (Group 1 = 24.1 ± 8 mmHg vs Group 2 = 21 ± 7 mmHg, p = .17). SSc patients did not show significantly different indexed LA volumes (Group 1 = 24.9 ± 5.3 ml/m2 vs Group 2 = 24.7 ± 4.4 ml/m2, p = .8), whereas E/e' ratio was significantly higher in SSc (Group 1 = 7.6 ± 2.4 vs Group 2 = 6.5 ± 1.7, p<0.05), although still within normal values. LA strain values were significantly different between the two groups (ϵ pos peak Group 1 = 31.3 ± 4.2% vs Group 2 = 35.0 ± 7.6%, p < .01, sec ϵ pos peak Group 1 = 18.4 ± 4 vs Group 2 = 21.4 ± 7.6, p < 0.05). CONCLUSION: 2D speckle-tracking echocardiography is a sensitive tool to assess impairment of LA mechanics, which is detectable in absence of changes in LA size and volume, and may represent an early sign of cardiac involvement in patients with SSc.


Asunto(s)
Ecocardiografía/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Cardiopatías/diagnóstico por imagen , Cardiopatías/etiología , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Módulo de Elasticidad , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Cardiopatías/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Esclerodermia Sistémica/fisiopatología , Sensibilidad y Especificidad , Estrés Mecánico
20.
Echocardiography ; 31(6): E169-73, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24661074

RESUMEN

Three-dimensional echocardiography (3DE) is a unique cardiovascular imaging modality in terms of: ability to provide realistic anatomical views of cardiac structures in the beating heart and possibility to visualize cardiac structures from any desired perspective. Therefore, 3DE is emerging as an accurate imaging modality for a prompt diagnosis and detailed anatomical description of structural complications (SC) of acute myocardial infarction (AMI). We report 3 emblematic cases which show how both the transthoracic (TTE) and transesophageal (TEE) 3D imaging can provide precise anatomic information useful to address management of SC in AMI patients: (1) detailed assessment of size, location, and morphology of an apical ventricular septal defect (VSD) obtained with 3DTTE was pivotal in referring the patient to percutaneous closure of it; (2) size and location of a complex inferior VSD with irregular margins advised against percutaneous closure; and (3) 3DTEE assisted surgeons to choose between reparative or replacement surgery for an acute mitral regurgitation due to complete papillary muscle rupture.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Defectos del Tabique Interventricular/cirugía , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/cirugía , Infarto del Miocardio/cirugía , Selección de Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA