Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Diabet Med ; : e15441, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39323029

RESUMEN

AIMS: Early post-transplant hyperglycaemia (EPTH) and post-transplant diabetes mellitus (PTDM) are common following solid organ transplantation and may be associated with adverse outcomes. We studied the prevalence of EPTH and cumulative 5-year prevalence of PTDM in a modern cohort of heart transplant recipients who were free from diabetes at baseline as well as the association of EPTH, PTDM and pre-transplant T2DM with adverse transplant-related outcomes. METHODS: Retrospective cohort study of heart transplant recipients followed for 5 years at a single centre in Sydney, Australia. RESULTS: A total of 141 patients were included, of whom 25 had pre-existing type 2 diabetes mellitus (T2DM) and 116 were free from diabetes at baseline. In patients without pre-existing T2DM, 88 of 116 (76%) experienced EPTH, which was associated with higher rates of acute rejection and hospitalizations, and lower 5-year survival. PTDM developed in 45 of 116 (39%) patients, all of whom had experienced EPTH. Both PTDM and pre-existing T2DM were associated with increased rates of graft rejection and hospitalization, and greater than three-fold increased likelihood of death compared to patients that remained free from diabetes. CONCLUSION: EPTH and PTDM are highly prevalent following cardiac transplantation. EPTH develops within days of transplant and is strongly associated with progression to PTDM. Pre-existing T2DM, PTDM and EPTH are associated with greater hospitalization, increased episodes of rejection and worse 5-year survival compared to patients who remained free from diabetes during follow-up.

2.
Artif Organs ; 48(1): 70-82, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37819003

RESUMEN

BACKGROUND: Dynamic respiratory maneuvers induce heterogenous changes to flow-pulsatility in continuous-flow left ventricular assist device patients. We evaluated the association of these pulsatility responses with patient hemodynamics and outcomes. METHODS: Responses obtained from HVAD (Medtronic) outpatients during successive weekly clinics were categorized into three ordinal groups according to the percentage reduction in flow-waveform pulsatility (peak-trough flow) upon inspiratory-breath-hold, (%∆P): (1) minimal change (%∆P ≤ 50), (2) reduced pulsatility (%∆P > 50 but <100), (3) flatline (%∆P = 100). Same-day echocardiography and right-heart-catheterization were performed. Readmissions were compared between patients with ≥1 flatline response (F-group) and those without (NF-group). RESULTS: Overall, 712 responses were obtained from 55 patients (82% male, age 56.4 ± 11.5). When compared to minimal change, reduced pulsatility and flatline responses were associated with lower central venous pressure (14.2 vs. 11.4 vs. 9.0 mm Hg, p = 0.08) and pulmonary capillary wedge pressure (19.8 vs. 14.3 vs. 13.0 mm Hg, p = 0.03), lower rates of ≥moderate mitral regurgitation (48% vs. 13% vs. 10%, p = 0.01), lower rates of ≥moderate right ventricular impairment (62% vs. 25% vs. 27%, p = 0.03), and increased rates of aortic valve opening (32% vs. 50% vs. 75%, p = 0.03). The F-group (n = 28) experienced numerically lower all-cause readmissions (1.51 vs. 2.79 events-per-patient-year [EPPY], hazard-ratio [HR] = 0.67, p = 0.12), reduced heart failure readmissions (0.07 vs. 0.57 EPPY, HR = 0.15, p = 0.008), and superior readmission-free survival (HR = 0.47, log-rank p = 0.04). Syncopal readmissions occurred exclusively in the F-group (0.20 vs. 0 EPPY, p = 0.01). CONCLUSION: Responses to inspiratory-breath-hold predicted hemodynamics and readmission risk. The impact of inspiratory-breath-hold on pulsatility can non-invasively guide hemodynamic management decisions, patient optimization, and readmission risk stratification.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Readmisión del Paciente , Corazón Auxiliar/efectos adversos , Función Ventricular Izquierda/fisiología , Presión Esfenoidal Pulmonar , Cateterismo Cardíaco , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Estudios Retrospectivos
3.
Heart Lung Circ ; 33(8): 1173-1183, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38604884

RESUMEN

BACKGROUND: Heart transplantation is an effective treatment for end-stage congestive heart failure, however, achieving the right balance of immunosuppression to maintain graft function while minimising adverse effects is challenging. Serial endomyocardial biopsies (EMBs) are currently the standard for rejection surveillance, despite being invasive. Replacing EMB-based surveillance with cardiac magnetic resonance (CMR)-based surveillance for acute cardiac allograft rejection has shown feasibility. This study aimed to assess the cost-effectiveness of CMR-based surveillance in the first year after heart transplantation. METHOD: A prospective clinical trial was conducted with 40 orthotopic heart transplant (OHT) recipients. Participants were randomly allocated into two surveillance groups: EMB-based, and CMR-based. The trial included economic evaluations, comparing the frequency and cost of surveillance modalities in relation to quality-adjusted life years (QALYs) within the first year post-transplantation. Sensitivity analysis encompassed modelled data from observed EMB and CMR arms, integrating two hypothetical models of expedited CMR-based surveillance. RESULTS: In the CMR cohort, 238 CMR scans and 15 EMBs were conducted, versus (vs) 235 EMBs in the EMB group. CMR surveillance yielded comparable rejection rates (CMR 74 vs EMB 94 events, p=0.10) and did not increase hospitalisation risk (CMR 32 vs EMB 46 events, p=0.031). It significantly reduced the necessity for invasive EMBs by 94%, lowered costs by an average of AUD$32,878.61, and enhanced cumulative QALY by 0.588 compared with EMB. Sensitivity analysis showed that increased surveillance with expedited CMR Models 1 and 2 were more cost-effective than EMB (all p<0.01), with CMR Model 1 achieving the greatest cost savings (AUD$34,091.12±AUD$23,271.86 less) and utility increase (+0.62±1.49 QALYs, p=0.011), signifying an optimal cost-utility ratio. Model 2 showed comparable utility to the base CMR model (p=0.900) while offering the benefit of heightened surveillance frequency during periods of elevated rejection risk. CONCLUSIONS: CMR-based rejection surveillance in orthotopic heart transplant recipients provides a cost-effective alternative to EMB-based surveillance. Furthermore, it reduces the need for invasive procedures, without increased risk of rejection or hospitalisation for patients, and can be incorporated economically for expedited surveillance. These findings have important implications for improving patient care and optimising resource allocation in post-transplant management.


Asunto(s)
Rechazo de Injerto , Trasplante de Corazón , Humanos , Trasplante de Corazón/economía , Rechazo de Injerto/economía , Rechazo de Injerto/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Australia/epidemiología , Estudios Prospectivos , Análisis Costo-Beneficio , Adulto , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/economía , Años de Vida Ajustados por Calidad de Vida , Estudios de Seguimiento , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos
4.
Circulation ; 145(25): 1811-1824, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35621277

RESUMEN

BACKGROUND: Endomyocardial biopsy (EMB) is the gold standard method for surveillance of acute cardiac allograft rejection (ACAR) despite its invasive nature. Cardiovascular magnetic resonance (CMR)-based myocardial tissue characterization allows detection of myocarditis. The feasibility of CMR-based surveillance for ACAR-induced myocarditis in the first year after heart transplantation is currently undescribed. METHODS: CMR-based multiparametric mapping was initially assessed in a prospective cross-sectional fashion to establish agreement between CMR- and EMB-based ACAR and to determine CMR cutoff values between rejection grades. A prospective randomized noninferiority pilot study was then undertaken in adult orthotopic heart transplant recipients who were randomized at 4 weeks after orthotopic heart transplantation to either CMR- or EMB-based rejection surveillance. Clinical end points were assessed at 52 weeks. RESULTS: Four hundred one CMR studies and 354 EMB procedures were performed in 106 participants. Forty heart transplant recipients were randomized. CMR-based multiparametric assessment was highly reproducible and reliable at detecting ACAR (area under the curve, 0.92; sensitivity, 93%; specificity, 92%; negative predictive value, 99%) with greater specificity and negative predictive value than either T1 or T2 parametric CMR mapping alone. High-grade rejection occurred in similar numbers of patients in each randomized group (CMR, n=7; EMB, n=8; P=0.74). Despite similarities in immunosuppression requirements, kidney function, and mortality between groups, the rates of hospitalization (9 of 20 [45%] versus 18 of 20 [90%]; odds ratio, 0.091; P=0.006) and infection (7 of 20 [35%] versus 14 of 20 [70%]; odds ratio, 0.192; P=0,019) were lower in the CMR group. On 15 occasions (6%), patients who were randomized to the CMR arm underwent EMB for clarification or logistic reasons, representing a 94% reduction in the requirement for EMB-based surveillance. CONCLUSIONS: A noninvasive CMR-based surveillance strategy for ACAR in the first year after orthotopic heart transplantation is feasible compared with EMB-based surveillance. REGISTRATION: HREC/13/SVH/66 and HREC/17/SVH/80. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12618000672257.


Asunto(s)
Trasplante de Corazón , Miocarditis , Adulto , Australia/epidemiología , Biopsia/métodos , Estudios Transversales , Rechazo de Injerto/diagnóstico , Trasplante de Corazón/efectos adversos , Humanos , Espectroscopía de Resonancia Magnética , Miocarditis/diagnóstico , Miocardio/patología , Proyectos Piloto , Estudios Prospectivos
5.
Heart Lung Circ ; 32(4): 467-479, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36841638

RESUMEN

BACKGROUND: With the rapid rollout of COVID-19 vaccinations, numerous associated and suspected adverse events have been reported nationally and worldwide. Literature reporting confirmed cases of pericarditis and myocarditis following SARS-CoV-2 mRNA vaccinations has evolved, with a predominance in adolescent males following the second dose. METHODS: This was a retrospective analysis of all patients presenting to St Vincent's Hospital, Sydney, Australia with suspected COVID-19 vaccine-related myocarditis and pericarditis. The Brighton Collaboration Case Definitions of Myocarditis and Pericarditis were used to categorise patients into groups based on diagnostic certainty. Cardiac magnetic resonance imaging findings were reviewed against updated Lake Louise Criteria for diagnosing patients with suspected myocarditis. RESULTS: We report 10 cases of confirmed, possible or probable myocarditis and pericarditis. The mean age of presentation in the vaccine group was 33±9.0 years. The most common presenting symptom was pleuritic chest pain (n=8, 80%). Eight patients (80%) had electrocardiogram (ECG) abnormalities (n=6 pericarditis, n=2 myocarditis). Five patients (50%) had a minimum 24 hours of cardiac monitoring. One patient had multisystem inflammatory syndrome following vaccination (MIS-V) with severely impaired left ventricular ejection fraction and required admission to the intensive care unit. DISCUSSION AND CONCLUSION: Cardiac complications post mRNA vaccines are rare. Our case series reflects the worldwide data that vaccine-related myocarditis and pericarditis most frequently occur in young males, following the second dose of the vaccine. These cardiac side effects are mild and self-limiting, with adequate responses to oral anti-inflammatories. One patient developed a severe reaction, with no fatal cases.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Miocarditis , Pericarditis , Adulto , Humanos , Adulto Joven , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Miocarditis/diagnóstico , Miocarditis/etiología , Pericarditis/diagnóstico , Pericarditis/etiología , Estudios Retrospectivos , Volumen Sistólico , Vacunación/efectos adversos , Función Ventricular Izquierda
6.
Clin Infect Dis ; 75(7): 1235-1238, 2022 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-35275984

RESUMEN

We present the first published case of successfully treated disseminated Aspergillus lentulus infection in a solid organ transplant recipient with invasive pulmonary disease, endophthalmitis, and a cerebral abscess. This case highlights important challenges associated with treating A. lentulus, particularly regarding antifungal resistance and toxicities associated with long-term antifungal therapy.


Asunto(s)
Antifúngicos , Trasplante de Corazón , Antifúngicos/farmacología , Antifúngicos/uso terapéutico , Aspergillus , Farmacorresistencia Fúngica , Trasplante de Corazón/efectos adversos , Humanos
7.
Emerg Infect Dis ; 28(11): 2155-2164, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36287030

RESUMEN

A multispecies outbreak of Nocardia occurred among heart transplant recipients (HTR), but not lung transplant recipients (LTR), in Sydney, New South Wales, Australia, during 2018-2019. We performed a retrospective review of 23 HTR and LTR who had Nocardia spp. infections during June 2015-March 2021, compared risk factors for Nocardia infection, and evaluated climate conditions before, during, and after the period of the 2018-2019 outbreak. Compared with LTR, HTR had a shorter median time from transplant to Nocardia diagnosis, higher prevalence of diabetes, greater use of induction immunosuppression with basiliximab, and increased rates of cellular rejection before Nocardia diagnosis. During the outbreak, Sydney experienced the lowest monthly precipitation and driest surface levels compared with time periods directly before and after the outbreak. Increased immunosuppression of HTR compared with LTR, coupled with extreme weather conditions during 2018-2019, may explain this outbreak of Nocardia infections in HTR.


Asunto(s)
Trasplante de Corazón , Nocardiosis , Nocardia , Humanos , Basiliximab , Combinación Trimetoprim y Sulfametoxazol , Nocardiosis/epidemiología , Nocardiosis/diagnóstico , Receptores de Trasplantes , Brotes de Enfermedades , Trasplante de Corazón/efectos adversos
8.
Intern Med J ; 52(10): 1826-1830, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36266066

RESUMEN

Cardiac light chain (AL) amyloidosis is a condition with a very poor prognosis. We report a retrospective analysis comparing the traditional melphalan and dexamethasone protocol with cyclophosphamide, bortezomib and dexamethasone in late-stage cardiac AL amyloidosis. The primary end points were overall survival and haematological response. Both regimens provided meaningful responses in this difficult to treat patient group.


Asunto(s)
Amiloidosis , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Humanos , Bortezomib , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/tratamiento farmacológico , Melfalán , Estudios Retrospectivos , Dexametasona , Amiloidosis/tratamiento farmacológico , Ciclofosfamida
9.
J Card Fail ; 27(6): 642-650, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33497807

RESUMEN

BACKGROUND: Although it has been established that continuous flow left ventricular assist devices are sensitive to loading conditions, the effect of acute load and postural changes on pump flow have not been explored systematically. METHODS AND RESULTS: Fifteen stable outpatients were studied. Patients sequentially transitioned from the seated position to supine, passive leg raise, and standing with transition effects documented. A modified Valsalva maneuver, consisting of a forced expiration with an open glottis, was performed in each position. A sustained, 2-handed handgrip was performed in the supine position. The pump flow waveform was recorded continuously and left ventricular end-diastolic diameter measured during each stage using transthoracic echocardiography. Transitioning from seated to supine posture produced a significant increase in the flow and the ventricular end-diastolic diameter, consistent with an increased preload. The transition from supine to standing produced a transient increase in the mean flow and decreased the flow pulsatility index. At steady state, these changes were reversed with a decrease in the mean and trough flow and increased pulsatility index, consistent with venous redistribution and possible baroreflex compensation. Four distinct patterns of standing-induced flow waveform effects were identified, reflecting varying preload, afterload, and individual compensatory effects. A sustained handgrip produced a significant decrease in flow and increase in flow pulsatility across all patients, reflecting an increased afterload pressure. A modified Valsalva maneuver produced a decrease in the flow pulsatility while seated, supine, and standing, but not during leg raise. Five patterns of pulsatility effect during Valsalva were observed: (1) minimal change, (2) pulsatility recovery, (3) rapid flatline, (4) slow flatline with delayed flow recovery, and (5) primary suction. CONCLUSIONS: Acute disturbances in loading conditions produce heterogeneous pump flow responses reflecting their complex interactions with pump and ventricular function as well as reflex compensatory mechanisms. Differences in responses and individual variabilities have significant implications for automated pump control algorithms.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Diástole , Fuerza de la Mano , Ventrículos Cardíacos , Humanos , Función Ventricular Izquierda
10.
Pacing Clin Electrophysiol ; 38(8): 925-33, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25940215

RESUMEN

BACKGROUND: Both implantable cardioverter defibrillators (ICDs) and left ventricular assist devices (LVADs) have a positive impact on survival in the heart failure population. We sought to determine whether these positive effects on survival are additive or whether LVAD therapy supersedes ICD therapy. METHOD: We analyzed survival data of patients implanted with nonpulsatile LVADs between October 2004 and March 2013. Survival in patients with ICDs (n = 64) was compared to those without ICDs (n = 36). Patients exited the study at the time of heart transplantation or death. RESULTS: A total of 100 patients underwent LVAD implantation during this time. Patients had a mean follow-up time of 364 ± 295 days. Death occurred in 15 (38%) patients in the no ICD group versus 18 (30%) in the ICD group. Univariate analysis demonstrated a marginal early survival benefit at up to 1 year post-LVAD implant in the ICD cohort; however, at time points greater than 1 year there was no statistically significant benefit in ICD therapy in LVAD patients (P = 0.56). Multivariate analysis did not show any significant predictor of survival. There were no patients who died of sudden cardiac death. There was no significant difference in the time to heart transplantation (443 days ± 251 no ICD vs 372 days ± 277 ICD, P = 0.37). CONCLUSION: The benefit of ICD therapy in the setting of continuous flow LVAD therapy is uncertain. Although prolonged ventricular arrhythmias (VAs) may potentially impact on patient survival, LVAD therapy is beneficial in prevention of sudden cardiac death due to VAs.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia
11.
Artif Organs ; 39(8): 704-9, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26234450

RESUMEN

As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV opening based on the area under the curve (AUC) of the power spectral density analysis of pump speed signal was developed. Data from patients implanted with HeartWare HVAD left ventricular assist device were studied at different pump speeds, with simultaneous transthoracic echocardiography in two cohorts. In the first group, pump data of 15 patients were used to investigate the ability to discriminate between an open and closed AV. In the second cohort of a further 13 patients, the duration of AV opening was measured from digitized M-mode images, and the relationship between the AV opening time and the new method assessed. In 14 of the initial 15 patients, AV status could be discriminated using only one threshold for all patients. In the second cohort, gradual speed reduction resulted in aortic valve opening in 12 of the 13 patients. The correlation between AV opening duration and AUC was 0.96 ± 0.03. Regression analysis indicated a linear relationship in each of the patients with a small error between the fit and the measured opening time (root mean square error = 11.0 ± 7.6 ms). However, the slopes (69.0 ± 52.8) and intercepts (-31.4 ± 78.0) varied widely between patients. The sensitivity and specificity for the new method using AUC threshold of 0.95 for aortic valve closure was 95% and 91%, respectively. The newly developed method to detect AV opening not only provides information on the AV status during LVAD support (open/closed) but also gives insight into the duration of AV opening. Because the slope of the relationship varies from patient to patient, initial training and adaptation of the method to each patient seems to be required.


Asunto(s)
Válvula Aórtica/fisiopatología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Hemodinámica , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Área Bajo la Curva , Austria , Ecocardiografía Doppler , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Nueva Gales del Sur , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Curva ROC , Singapur , Factores de Tiempo , Resultado del Tratamiento
12.
Artif Organs ; 38(12): 1029-34, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24660889

RESUMEN

It is important to accurately monitor residual cardiac function in patients under long-term continuous-flow left ventricular assist device (cfLVAD) support. Two new measures of left ventricular (LV) chamber contractility in the cfLVAD-unloaded ventricle include IQ, a regression coefficient between maximum flow acceleration and flow pulsatility at different pump speeds; and K, a logarithmic relationship between volumes moved in systole and diastole. We sought to optimize these indices. We also propose RIQ, a ratio between maximum flow acceleration and flow pulsatility at baseline pump speed, as an alternative to IQ. Eleven patients (mean age 49 ± 11 years) were studied. The K index was derived at baseline pump speed by defining systolic and diastolic onset as time points at which maximum and minimum volumes move through the pump. IQ across the full range of pump speeds was markedly different between patients. It was unreliable in three patients with underlying atrial fibrillation (coefficient of determination R(2) range: 0.38-0.74) and also when calculated without pump speed manipulation (R(2) range: 0.01-0.74). The K index was within physiological ranges, but poorly correlated to both IQ (P = 0.42) and RIQ (P = 0.92). In four patients there was excellent correspondence between RIQ and IQ, while four other patients showed a poor relationship between these indices. As RIQ does not require pump speed changes, it may be a more clinically appropriate measure. Further studies are required to determine the validity of these indices.


Asunto(s)
Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Contracción Muscular/fisiología , Flujo Pulsátil/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad
13.
Heart Lung Circ ; 23(10): 963-9, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24973864

RESUMEN

BACKGROUND: New generation continuous-flow left ventricular assist devices (LVADs) utilise centrifugal pumps. Data concerning their effect on patient haemodynamics, ventricular function and tissue perfusion is limited. We aimed to document these parameters following HeartWare centrifugal continuous-flow LVAD (HVAD) implantation and to assess the impact of post-operative right heart failure (RHF). METHODS: We reviewed 53 consecutive patients (mean age 49.5 ± 14.1 yrs) with HVAD implanted in the left ventricle, at St. Vincent's Hospital, Sydney, between January 2007 and August 2012. Available paired right heart catheterisation (n=35) and echocardiography (n=39) data was reviewed to assess response of invasive haemodynamics and ventricular function to LVAD support. RESULTS: A total of 28 patients (53%) were implanted from interim mechanical circulatory support. Seventeen patients (32%) required short-term post-implant veno-pulmonary artery extracorporeal membrane oxygenation. At 100 ± 61 days post-implant, mean pulmonary artery pressure and mean pulmonary capillary wedge pressure decreased from 38.8 ± 7.7 to 22.9 ± 7.7 mmHg and 28.3 ± 6.4 to 13.4 ± 5.4 mmHg respectively (p<0.001). LV end diastolic diameter decreased from 71.3 ± 12.7 to 61.1 ± 13.7 mm and LV end-systolic diameter from 62.7 ± 12.3 to 53.9 ± 14.4mm (p<0.001). Aortic regurgitation remained trivial. Serum sodium increased from 133.3 ± 5.7 to 139.3 ± 2.8 mmol/L and creatinine decreased from 109.1 ± 42.5 to 74.3 ± 26.2 µmol/L (p<0.001). Across the entire cohort, the six-month survival/transplant rate was significantly lower for RHF patients (72.2%, n=18) compared to those without (96.9%, n=35, p=0.01). CONCLUSIONS: HVAD support improves haemodynamics, LV dimensions and renal function. Following implantation with a centrifugal continuous-flow LVAD, RHF remains a significant risk with a tendency to worse outcomes in the short to medium term.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Hemodinámica , Disfunción Ventricular Izquierda/cirugía , Adulto , Presión Arterial , Cateterismo Cardíaco , Creatinina/sangre , Ecocardiografía , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertrofia Ventricular Izquierda/complicaciones , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Presión Esfenoidal Pulmonar , Sodio/sangre , Tasa de Supervivencia , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/fisiopatología
14.
ASAIO J ; 2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-39052927

RESUMEN

Type 1 cardiorenal syndrome is associated with significant excess morbidity and mortality in patients with severe acute decompensated heart failure. Previous trials of vasoactive drugs and ultrafiltration have not shown superiority over placebo or intravenous diuretics. Pilot data suggest short-term mechanical support devices may support diuresis in the cardiorenal syndrome. We evaluated the intra-aortic balloon pump (IABP) and a novel intra-aortic entrainment pump (IAEP) in a mock circulation loop (MCL) biventricular systolic heart failure model, to assess impact on renal flow and cardiac hemodynamics. Both devices produced similar and only modest increase in renal flow (IABP 3.3% vs. IAEP 4.3%) and cardiac output, with associated reduction in afterload elastance in the MCL. There were minor changes in coronary flow, increase with IABP and minor decrease with IAEP. Differences in device preload and afterload did not impact percentage change in renal flow with IABP therapy, however, there was a trend toward higher percentage flow change with IAEP in response to high baseline renal flow. The IAEP performed best in a smaller aorta and with more superior positioning within the descending aorta. Demonstrated changes in MCL flow during IAEP were of lower magnitude than previous animal studies, possibly due to lack of autoregulation and hormonal responses.

15.
J Heart Lung Transplant ; 43(3): 420-431, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37844674

RESUMEN

BACKGROUND: Left ventricular assist device (LVAD) support offers remodeling potential in some patients. Our goal was to use noninvasively derived pressure-volume (PV) loops to understand the effect of demographic and device variables on serial changes in cardiac function under pump support. METHODS: Thirty-two consecutive Medtronic HeartWare Ventricular Assist Device (HVAD) patients (mean 55.9 ± 12.3 years, 81.3% male) were prospectively recruited. Single-cycle ventricular pressure and volume were estimated using a validated algorithm. PV loops (n = 77) and corresponding cardiac chamber dynamics were derived at predefined postimplant timepoints (1, 3, 6 months). Changes in PV loop parameters sustained across the 6-month period were characterized using mixed-effects modeling. The influence of demographic and device variables on the observed changes was assessed. RESULTS: Across a 6-month period, the mean ventricular function parameters remained stable. Significant predictors of monthly improvement of stroke work include: lower pump speeds (2400 rpm vs 2500-2800 rpm) [0.0.051 mm Hg/liter/month (p = 0.001)], high pulsatility index (>1.0 vs <1.0) [0.052 mm Hg/liter/month (p = 0.012)], and ischemic cardiomyopathy indication for LVAD implantation (vs nonischemic) [0.0387 mm Hg/liter/month (p = 0.007)]. Various other cardiac chamber function parameters including cardiac power, peak systolic pressure, and LV elastance also showed improvements in these cohorts. CONCLUSIONS: Factors associated with improvement in ventricular energetics and hemodynamics under LVAD support can be determined with noninvasive PV loops. Understanding the basis of increasing ventricular load to optimize myocardial remodeling may prove valuable in selecting eligible recovery candidates.


Asunto(s)
Corazón Auxiliar , Función Ventricular Izquierda , Humanos , Masculino , Femenino , Miocardio , Ventrículos Cardíacos , Hemodinámica/fisiología
16.
ASAIO J ; 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39362188

RESUMEN

The development of right heart failure (RHF) in patients with advanced heart failure following left ventricular assist device (LVAD) implantation remains difficult to predict. We proposed a novel composite hemodynamic index-the right ventricular-arterial compliance index (RVACi), derived from pulmonary artery pulse pressure (PAPP), ejection time (ET), heart rate (HR), and cardiac output (CO), with and expressed as mm Hg·s/L. We then conducted a retrospective, single-center analysis comparing the predictive value of RVACi for the development of RHF or unplanned right ventricular (RV) mechanical circulatory support following LVAD implantation against existing hemodynamic indices. One hundred patients were enrolled after screening 232 patients over a 10 year period, with 74 patients having complete hemodynamic data for RVACi calculation. There was good correlation between pulmonary arterial capacitance (R² = 0.48) and pulmonary vascular resistance (R² = 0.63) with RVACi, but not RV stroke work index or pulmonary artery pulsatility index. Reduced baseline RVACi (52 ± 23 vs. 92 ± 55 mm Hg·s/L; p = 0.02) was the strongest hemodynamic predictor of unplanned RV mechanical circulatory support requirement in patients following LVAD insertion. Composite pulsatile hemodynamic indices including RVACi may provide additional insight over existing hemodynamic indices for the prediction of RHF and need for RV mechanical circulatory support.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39089605

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist device (cfLVAD) use is effective in supporting patients with end-stage heart failure (ESHF). Reduced flow pulsatility within the systemic circulation in cfLVAD-supported patients may lead to alterations within the microcirculation. Temporal changes in microvasculature in relation to adverse events in cfLVAD-supported patients have not been studied. We aimed to profile changes within retinal microvasculature and its association with adverse events. METHODS: Retinal photography was performed using Topcon TRC-NW8 nonmydriatic fundus camera in cfLVAD-supported patients and ESHF control patients. Specific retinal measurements were evaluated using a validated semiautomated program. Demographic and adverse event data were documented. RESULTS: Forty-eight patients were studied (n = 29 cfLVAD, n = 19 ESHF). There were significant trends in retinal arteriolar caliber (B = -0.53 µm, 95% confidence interval [CI]: -0.96 to -0.10, p = 0.016) and retinal fractal dimension parameters (B = 0.014, 95% CI: 0.001-0.002, p = 0.016) in linear mixed model regressions. Among cfLVAD patients, there was a significant association between the incidence of gastrointestinal bleeding and stepwise increases in retinal arteriolar-venular caliber ratio (hazard ratio: 3.03, 95% CI: 2.06-4.45, p = 0.005), a measure of arteriolar narrowing. CONCLUSIONS: We have observed for the first time that alterations in retinal microvasculature in cfLVAD-supported patients may be associated with gastrointestinal bleeding. While understanding these temporal changes may predict future adverse events in cfLVAD-supported patients, further multicenter studies are required to confirm the associations observed.

18.
Transplantation ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39020464

RESUMEN

BACKGROUND: Coronary allograft vasculopathy (CAV) remains a significant cause of morbidity and mortality after heart transplantation. The use of aspirin for CAV prophylaxis has recently garnered interest as a possible therapeutic adjunct in this setting. METHODS: This 2-center retrospective cohort study included 372 patients who underwent heart transplantation between January 2009 and March 2018 and were stratified according to the commencement of aspirin during their index transplant admission. The primary outcome was the development of moderate or severe CAV (International Society for Heart and Lung Transplantation grade ≥2) at surveillance coronary angiography. Secondary endpoints included mortality at follow-up. RESULTS: There were no differences in age, sex, and cause of heart failure. In the early aspirin group, the preponderant risk factors included use of ventricular assist devices, pretransplant smoking, and mild or moderate rejection. Multivariable analyses to assess for independent predictors of CAV development and mortality demonstrated that aspirin was associated with reduced mortality (adjusted hazard ratio = 0.19; 95% confidence interval, 0.08-0.47, P < 0.01) and a trend toward a protective effect against the development of moderate or severe CAV (adjusted hazard ratio = 0.24; 95% confidence interval, 0.54-1.19; P = 0.08). CONCLUSIONS: In this retrospective risk-adjusted 2-center cohort study, early aspirin administration was associated with reduced risk of death and a trend toward a protective effect against CAV development. These findings warrant validation in prospective randomized trials.

19.
Artif Organs ; 37(3): 313-8, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23373528

RESUMEN

The current recommended anticoagulation regimen during continuous flow centrifugal left ventricular device support is a combination of antiplatelet therapy as well as oral anticoagulation. Despite this, pump thrombosis occurs in rare situations. We report the risk factors and nonsurgical management and outcomes of five patients implanted with continuous flow centrifugal left ventricular assist devices who displayed clinical, hemodynamic, and laboratory features of intrapump thrombosis. This information may support the use of intravenous thrombolytics for suspected pump thrombus in these newer generation devices.


Asunto(s)
Fibrinolíticos/administración & dosificación , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Terapia Trombolítica , Trombosis/tratamiento farmacológico , Función Ventricular Izquierda , Adulto , Anticoagulantes/uso terapéutico , Resultado Fatal , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Hemodinámica , Hemólisis , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Trombosis/sangre , Trombosis/diagnóstico , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
20.
Heart Lung Circ ; 22(11): 952-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23506725

RESUMEN

LVADs are increasingly being used to support patients with end stage heart failure. As such, the traditional definition of death, the absence of a pulse, requires re-examination as it is no longer clinically relevant. We present two contrasting cases of "death" on LVAD support and present some ethical issues surrounding the end of life on LVAD support.


Asunto(s)
Cardiomegalia , Corazón Auxiliar , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA