Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Med ; 84(4): 1977-1990, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32281179

RESUMEN

PURPOSE: To demonstrate the feasibility of an optimized set of small-tip fast recovery (STFR) MRI scans for rapidly estimating myelin water fraction (MWF) in the brain. METHODS: We optimized a set of STFR scans to minimize the Cramér-Rao Lower Bound of MWF estimates. We evaluated the RMSE of MWF estimates from the optimized scans in simulation. We compared STFR-based MWF estimates (both modeling exchange and not modeling exchange) to multi-echo spin echo (MESE)-based estimates. We used the optimized scans to acquire in vivo data from which a MWF map was estimated. We computed the STFR-based MWF estimates using PERK, a recently developed kernel regression technique, and the MESE-based MWF estimates using both regularized non-negative least squares (NNLS) and PERK. RESULTS: In simulation, the optimized STFR scans led to estimates of MWF with low RMSE across a range of tissue parameters and across white matter and gray matter. The STFR-based MWF estimates that modeled exchange compared well to MESE-based MWF estimates in simulation. When the optimized scans were tested in vivo, the MWF map that was estimated using a 3-compartment model with exchange was closer to the MESE-based MWF map. CONCLUSIONS: The optimized STFR scans appear to be well suited for estimating MWF in simulation and in vivo when we model exchange in training. In this case, the STFR-based MWF estimates are close to the MESE-based estimates.


Asunto(s)
Vaina de Mielina , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética , Agua , Sustancia Blanca/diagnóstico por imagen
2.
IEEE Trans Med Imaging ; 37(9): 2103-2114, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29994085

RESUMEN

This paper introduces a fast, general method for dictionary-free parameter estimation in quantitative magnetic resonance imaging (QMRI) parameter estimation via regression with kernels (PERK). PERK first uses prior distributions and the nonlinear MR signal model to simulate many parameter-measurement pairs. Inspired by machine learning, PERK then takes these parameter-measurement pairs as labeled training points and learns from them a nonlinear regression function using kernel functions and convex optimization. PERK admits a simple implementation as per-voxel nonlinear lifting of MRI measurements followed by linear minimum mean-squared error regression. We demonstrate PERK for $ {\textit {T}_{1}}, {\textit {T}_{2}}$ estimation, a well-studied application where it is simple to compare PERK estimates against dictionary-based grid search estimates and iterative optimization estimates. Numerical simulations as well as single-slice phantom and in vivo experiments demonstrate that PERK and other tested methods produce comparable $ {\textit {T}_{1}}, {\textit {T}_{2}}$ estimates in white and gray matter, but PERK is consistently at least $140\times $ faster. This acceleration factor may increase by several orders of magnitude for full-volume QMRI estimation problems involving more latent parameters per voxel.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Humanos , Dinámicas no Lineales
3.
IEEE Trans Med Imaging ; 36(2): 467-477, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27893386

RESUMEN

Rapid, reliable quantification of MR relaxation parameters T1 and T2 is desirable for many clinical applications. Steady-state sequences such as Spoiled Gradient-Recalled Echo (SPGR) and Dual-Echo Steady-State (DESS) are fast and well-suited for relaxometry because the signals they produce are quite sensitive to T1 and T2 variation. However, T1, T2 estimation with these sequences typically requires multiple scans with varied sets of acquisition parameters. This paper describes a systematic framework for selecting scan types (e.g., combinations of SPGR and DESS scans) and optimizing their respective parameters (e.g., flip angles and repetition times). The method is based on a Cramér-Rao Bound (CRB)-inspired min-max optimization that finds scan parameter combinations that robustly enable precise object parameter estimation. We apply this technique to optimize combinations of SPGR and DESS scans for T1, T2 relaxometry in white matter (WM) and grey matter (GM) regions of the human brain at 3T field strength. Phantom accuracy experiments show that SPGR/DESS scan combinations are in excellent agreement with reference measurements. Phantom precision experiments show that trends in T1,T2 pooled sample standard deviations reflect CRB-based predictions. In vivo experiments show that in WM and GM, T1 and T2 estimates from a pair of optimized DESS scans exhibit precision (but not necessarily accuracy) comparable to that of optimized combinations of SPGR and DESS scans. To our knowledge, T1 maps from DESS acquisitions alone are new. This example application illustrates that scan optimization may help reveal new parameter mapping techniques from combinations of established pulse sequences.


Asunto(s)
Imagen por Resonancia Magnética , Encéfalo , Humanos , Fantasmas de Imagen , Cintigrafía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA