1.
J Vasc Interv Radiol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38972574

RESUMEN

Despite advancements in precision and efficacy of microwave ablation for tumor management, accurately predicting ablation zone geometry and minimum ablation margin remains a major challenge. This pilot study seeks to elucidate the influence of probe configuration on the morphometry of resulting ablation zones using tissue mimicking thermochromic phantoms. In-vitro results from 12 ablations were analyzed: a single probe ablation (n=1) and dual probe ablations (n=11). Angles and separations greatly influenced ablation zone morphometry. In dual-probe ablations, probe tip separation and angle of offset were positively correlated with ablation zone volume, length, and cross-sectional circularity. IR ablation planning is currently suboptimal, as it often relies upon cognitive registration. Even treatment planning software creates virtual composite ablation volumes based upon data from theoretical ablations in single, idealized configurations and settings. These findings draw attention to a need for improved ablation zone prediction and planning, which might impact efficiency, safety, cost, and outcomes.

2.
J Vasc Interv Radiol ; 35(3): 452-461.e3, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37852601

RESUMEN

PURPOSE: To develop and evaluate a smartphone augmented reality (AR) system for a large 50-mm liver tumor ablation with treatment planning for composite overlapping ablation zones. MATERIALS AND METHODS: A smartphone AR application was developed to display tumor, probe, projected probe paths, ablated zones, and real-time percentage of the ablated target tumor volume. Fiducial markers were attached to phantoms and an ablation probe hub for tracking. The system was evaluated with tissue-mimicking thermochromic phantoms and gel phantoms. Four interventional radiologists performed 2 trials each of 3 probe insertions per trial using AR guidance versus computed tomography (CT) guidance approaches in 2 gel phantoms. Insertion points and optimal probe paths were predetermined. On Gel Phantom 2, serial ablated zones were saved and continuously displayed after each probe placement/adjustment, enabling feedback and iterative planning. The percentages of tumor ablated for AR guidance versus CT guidance, and with versus without display of recorded ablated zones, were compared among interventional radiologists with pairwise t-tests. RESULTS: The means of percentages of tumor ablated for CT freehand and AR guidance were 36% ± 7 and 47% ± 4 (P = .004), respectively. The mean composite percentages of tumor ablated for AR guidance were 43% ± 1 (without) and 50% ± 2 (with display of ablation zone) (P = .033). There was no strong correlation between AR-guided percentage of ablation and years of experience (r < 0.5), whereas there was a strong correlation between CT-guided percentage of ablation and years of experience (r > 0.9). CONCLUSIONS: A smartphone AR guidance system for dynamic iterative large liver tumor ablation was accurate, performed better than conventional CT guidance, especially for less experienced interventional radiologists, and enhanced more standardized performance across experience levels for ablation of a 50-mm tumor.


Asunto(s)
Realidad Aumentada , Neoplasias Hepáticas , Cirugía Asistida por Computador , Humanos , Teléfono Inteligente , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía
3.
Int J Hyperthermia ; 36(1): 817-826, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31451077

RESUMEN

Objective: Thermosensitive liposomal doxorubicin (TSL-Dox) is a promising stimuli-responsive nanoparticle drug delivery system that rapidly releases the contained drug in response to hyperthermia (HT) (>40 °C). Combined with localized heating, TSL-Dox allows highly localized delivery. The goals of this study were to demonstrate that real-time fluorescence imaging can visualize drug uptake during delivery, and can predict tumor drug uptake. Methods: Nude mice carrying subcutaneous tumors (Lewis lung carcinoma) were anesthetized and injected with TSL-Dox (5 mg/kg dose). Localized HT was induced by heating tumors for 15, 30 or 60 min via a custom-designed HT probe placed superficially at the tumor location. In vivo fluorescence imaging (excitation 523 nm, emission 610 nm) was performed before, during, and for 5 min following HT. After imaging, tumors were extracted, drug uptake was quantified by high-performance liquid chromatography, and correlated with in vivo fluorescence. Plasma samples were obtained before and after HT to measure TSL-Dox pharmacokinetics. Results: Local drug uptake could be visualized in real-time during HT. Compared to unheated control tumors, fluorescence of heated tumors increased by 4.6-fold (15 min HT), 9.3-fold (30 min HT), and 13.2-fold (60 min HT). HT duration predicted tumor drug uptake (p = .02), with tumor drug concentrations of 4.2 ± 1.3 µg/g (no HT), 7.1 ± 5.9 µg/g (15 min HT), 14.1 ± 6.7 µg/g (30 min HT) and 21.4 ± 12.6 µg/g (60 min HT). There was good correlation (R2 = 0.67) between fluorescence of the tumor region and tumor drug uptake. Conclusions: Real-time in vivo fluorescence imaging can visualize drug uptake during delivery, and can predict tumor drug uptake.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Pulmonar de Lewis/diagnóstico por imagen , Carcinoma Pulmonar de Lewis/terapia , Doxorrubicina/análogos & derivados , Hipertermia Inducida , Imagen Óptica , Animales , Antibióticos Antineoplásicos/sangre , Antibióticos Antineoplásicos/farmacocinética , Carcinoma Pulmonar de Lewis/metabolismo , Doxorrubicina/administración & dosificación , Doxorrubicina/sangre , Doxorrubicina/farmacocinética , Sistemas de Liberación de Medicamentos , Femenino , Ratones Endogámicos BALB C , Ratones Desnudos , Polietilenglicoles/administración & dosificación , Polietilenglicoles/farmacocinética , Temperatura
4.
Int J Hyperthermia ; 36(1): 518-529, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31046513

RESUMEN

PURPOSE: Tissue-mimicking phantoms (TMPs) are synthetic materials designed to replicate properties of biological tissues. There is a need to quantify temperature changes following ultrasound or magnetic resonance imaging-guided high intensity focused ultrasound (MR-HIFU). This work describes development, characterization and evaluation of tissue-mimicking thermochromic phantom (TMTCP) for direct visualization and quantification of HIFU heating. The objectives were to (1) develop an MR-imageable, HIFU-compatible TMTCP that reports absolute temperatures, (2) characterize TMTCP physical properties and (3) examine TMTCP color change after HIFU. METHODS AND MATERIALS: A TMTCP was prepared to contain thermochromic ink, silicon dioxide and bovine serum albumin (BSA) and its properties were quantified. A clinical MRI-guided and a preclinical US-guided HIFU system were used to perform sonications in TMTCP. MRI thermometry was performed during HIFU, followed by T2-weighted MRI post-HIFU. Locations of color and signal intensity change were compared to the sonication plan and to MRI temperature maps. RESULTS: TMTCP properties were comparable to those in human soft tissues. Upon heating, the TMTCP exhibited an incremental but permanent color change for temperatures between 45 and 70 °C. For HIFU sonications the TMTCP revealed spatially sharp regions of color change at the target locations, correlating with MRI thermometry and hypointense regions on T2-weighted MRI. TMTCP-based assessment of various HIFU applications was also demonstrated. CONCLUSIONS: We developed a novel MR-imageable and HIFU-compatible TMTCP to characterize HIFU heating without MRI or thermocouples. The HIFU-optimized TMTCP reports absolute temperatures and ablation zone geometry with high spatial resolution. Consequently, the TMTCP can be used to evaluate HIFU heating and may provide an in vitro tool for peak temperature assessment, and reduce preclinical in vivo requirements for clinical translation.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética/métodos , Termometría/métodos , Humanos
5.
Radiology ; 289(2): 396-404, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30106347

RESUMEN

Purpose To correlate bead location and attenuation on CT images with the quantity and distribution of drug delivered to the liver following transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEB) in a rabbit tumor model. Materials and Methods All procedures were performed with a protocol approved by the Institutional Animal Care and Use Committee. TACE was performed in rabbits (n = 4) bearing VX2 liver tumors by using radiopaque DEB (70-150 µm) loaded with doxorubicin (DOX). Livers were resected 1 hour after embolization, immediately frozen, and cut by using liver-specific three-dimensional-printed molds for colocalization of liver specimens and CT imaging. DOX penetration into tissue surrounding beads was evaluated with fluorescence microscopy. DOX levels in liver specimens were predicted by using statistical models correlating DOX content measured in tissue with bead volume and attenuation measured on CT images. Model predictions were then compared with actual measured DOX concentrations to assess the models' predictive power. Results Eluted DOX remained in close proximity (<600 µm) to beads in the liver 1 hour after TACE. Bead volume and attenuation measured on CT images demonstrated positive linear correlations (0.950 and 0.965, respectively) with DOX content in liver specimens. DOX content model predictions based on CT images were accurate compared with actual liver DOX levels at 1 hour. Conclusion CT may be used to estimate drug dose delivery and distribution in the liver following transarterial chemoembolization (TACE) with doxorubicin-loaded radiopaque drug-eluting beads (DEB). Although speculative, this informational map might be helpful in planning and understanding the spatial effects of TACE with DEB. © RSNA, 2018.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos , Hígado/diagnóstico por imagen , Microesferas , Conejos
6.
Future Oncol ; 14(26): 2741-2760, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29944007

RESUMEN

This review describes the historical development of an imageable spherical embolic agent and focuses on work performed in collaboration between Biocompatibles UK Ltd (a BTG International group company) and the NIH to demonstrate radiopaque bead utility and bring a commercial offering to market that meets a clinical need. Various chemistries have been investigated and multiple prototypes evaluated in search of an optimized product with the right balance of handling and imaging properties. Herein, we describe the steps taken in the development of DC Bead LUMI™, the first commercially available radiopaque drug-eluting bead, ultimately leading to the first human experience of this novel embolic agent in the treatment of liver tumors.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Quimioembolización Terapéutica/métodos , Portadores de Fármacos/química , Desarrollo de Medicamentos , Neoplasias Hepáticas/terapia , Animales , Quimioembolización Terapéutica/instrumentación , Medios de Contraste/química , Modelos Animales de Enfermedad , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Microesferas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
7.
Int J Hyperthermia ; 34(6): 786-794, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29284329

RESUMEN

PURPOSE: Current release assays have inadequate temporal resolution ( ∼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery. MATERIALS AND METHODS: We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C. RESULTS: The millifluidic device allowed measurement of release kinetics within the first few seconds at ∼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS. CONCLUSIONS: The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Liberación de Fármacos/efectos de los fármacos , Hipertermia Inducida/métodos , Liposomas/química , Microfluídica/métodos , Humanos , Temperatura
8.
Int J Hyperthermia ; 33(7): 733-740, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28540814

RESUMEN

PURPOSE: To evaluate lyso-thermosensitive liposomal doxorubicin (LTLD, ThermoDox®) in combination with loco-regional mild hyperthermia (HT) for targeted drug delivery to the bladder wall and potential treatment of bladder cancer. MATERIAL AND METHODS: Porcine in vivo studies were performed with the following groups: (i) intravenous (IV) LTLD with hyperthermia (LTLD + HT); (ii) IV doxorubicin (DOX) with hyperthermia (IV DOX + HT) and (iii) IV LTLD without hyperthermia (LTLD - HT). Drug formulations were delivered via 30 min IV infusion coinciding with 1-h bladder irrigation (45 °C water for HT groups, 37 °C for non-HT group), followed by immediate bladder resection. DOX concentrations were measured in consecutive sections parallel to the bladder lumen by liquid chromatography following drug extraction. Computer models were developed to simulate tissue heating and drug release from LTLD. RESULTS: Comparing mean DOX concentrations at increasing depths from the lumen to outer surface of the bladder wall, the ranges for LTLD + HT, IV DOX + HT and LTLD - HT, respectively, were 20.32-3.52 µg/g, 2.34-0.61 µg/g and 2.18-0.51 µg/g. The average DOX concentrations in the urothelium/lamina and muscularis, respectively, were 9.7 ± 0.67 and 4.09 ± 0.81 µg/g for IV LTLD + HT, 1.2 ± 0.39 and 0.86 ± 0.24 µg/g for IV DOX + HT, and 1.15 ± 0.38 and 0.62 ± 0.15 µg/g for LTLD - HT. Computational model results were similar to measured DOX levels and suggest adequate temperatures were reached within the bladder wall for drug release from LTLD. CONCLUSIONS: Doxorubicin accumulation and distribution within the bladder wall was achieved at concentrations higher than with free IV doxorubicin by mild bladder hyperthermia combined with systemic delivery of LTLD.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Doxorrubicina/análogos & derivados , Sistemas de Liberación de Medicamentos , Hipertermia Inducida , Animales , Antibióticos Antineoplásicos/farmacocinética , Terapia Combinada , Doxorrubicina/administración & dosificación , Doxorrubicina/farmacocinética , Femenino , Polietilenglicoles/administración & dosificación , Polietilenglicoles/farmacocinética , Porcinos , Vejiga Urinaria/metabolismo , Neoplasias de la Vejiga Urinaria/terapia
9.
Pharm Res ; 33(10): 2459-69, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27343000

RESUMEN

PURPOSE: Low temperature sensitive liposome (LTSL) encapsulated docetaxel were combined with mild hyperthermia (40-42°C) to investigate in vivo biodistribution and efficacy against a castrate resistant prostate cancer. METHOD: Female athymic nude mice with human prostate PC-3 M-luciferase cells grown subcutaneously into the right hind leg were randomized into six groups: saline (+/- heat), free docetaxel (+/- heat), and LTSL docetaxel (+/- heat). Treatment (15 mg docetaxel/kg) was administered via tail vein once tumors reached a size of 200-300 mm(3). Mice tumor volumes and body weights were recorded for up to 60 days. Docetaxel concentrations of harvested tumor and organ/tissue homogenates were determined by LC-MS. Histological evaluation (Mean vessel density, Ki67 proliferation, Caspase-3 apoptosis) of saline, free Docetaxel and LTSL docetaxel (+/- heat n = 3-5) was performed to determine molecular mechanism responsible for tumor cell killing. RESULT: LTSL/heat resulted in significantly higher tumor docetaxel concentrations (4.7-fold greater compared to free docetaxel). Adding heat to LTSL Docetaxel or free docetaxel treatment resulted in significantly greater survival and growth delay compared to other treatments (p < 0.05). Differences in body weight between all Docetaxel treatments were not reduced by >10% and were not statistically different from each other. Molecular markers such as caspase-3 were upregulated, and Ki67 expression was significantly decreased in the chemo-hyperthermia group. Vessel density was similar post treatment, but the heated group had reduced vessel area, suggesting thermal enhancement in efficacy by reduction in functional perfusion. CONCLUSION: This technique of hyperthermia sensitization and enhanced docetaxel delivery has potential for clinical translation for prostate cancer treatment.


Asunto(s)
Antineoplásicos/metabolismo , Modelos Animales de Enfermedad , Hipertermia Inducida/métodos , Neoplasias de la Próstata/metabolismo , Taxoides/metabolismo , Animales , Antineoplásicos/administración & dosificación , Línea Celular Tumoral , Docetaxel , Sistemas de Liberación de Medicamentos/métodos , Femenino , Humanos , Liposomas , Masculino , Ratones , Ratones Desnudos , Neoplasias de la Próstata/tratamiento farmacológico , Neoplasias de la Próstata/mortalidad , Distribución Aleatoria , Tasa de Supervivencia/tendencias , Taxoides/administración & dosificación , Temperatura , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología , Ensayos Antitumor por Modelo de Xenoinjerto/métodos
10.
J Vasc Interv Radiol ; 27(1): 117-126.e3, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26549370

RESUMEN

PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.


Asunto(s)
Quimioembolización Terapéutica/instrumentación , Portadores de Fármacos , Neoplasias Hepáticas Experimentales/terapia , Microesferas , Animales , Modelos Animales de Enfermedad , Doxorrubicina/administración & dosificación , Aceite Etiodizado/administración & dosificación , Hígado/diagnóstico por imagen , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Fantasmas de Imagen , Conejos , Microtomografía por Rayos X
11.
Int J Hyperthermia ; 32(3): 239-43, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27099078

RESUMEN

Purpose The purpose of this study was to (1) develop a novel tissue-mimicking thermochromic (TMTC) phantom that permanently changes colour from white to magenta upon heating above ablative temperatures, and (2) assess its utility for specific applications in evaluating thermal therapy devices. Materials and methods Polyacrylamide gel mixed with thermochromic ink was custom made to produce a TMTC phantom that changes its colour upon heating above biological ablative temperatures (> 60 °C). The thermal properties of the phantom were characterised, and compared to those of human tissue. In addition, utility of this phantom as a tool for the assessment of laser and microwave thermal ablation was examined. Results The mass density, thermal conductivity, and thermal diffusivity of the TMTC phantom were measured as 1033 ± 1.0 kg/m(3), 0.590 ± 0.015 W/m.K, and 0.145 ± 0.002 mm(2)/s, respectively, and found to be in agreement with reported values for human soft tissues. Heating the phantom with laser and microwave ablation devices produced clearly demarcated regions of permanent colour change geographically corresponding to regions with temperature elevations above 60 °C. Conclusion The TMTC phantom provides direct visualisation of ablation dynamics, including ablation volume and geometry as well as peak absolute temperatures within the treated region post-ablation. This phantom can be specifically tailored for different thermal therapy modalities, such as radiofrequency, laser, microwave, or therapeutic ultrasound ablation. Such modality-specific phantoms may enable better quality assurance, device characterisation, and ablation parameter optimisation, or optimise the study of dynamic heating parameters integral to drug device combination therapies relying upon heat.


Asunto(s)
Técnicas de Ablación , Hipertermia Inducida , Neoplasias/terapia , Fantasmas de Imagen , Resinas Acrílicas , Color , Humanos , Rayos Láser , Microondas , Temperatura , Conductividad Térmica
12.
Int J Hyperthermia ; 31(1): 67-73, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25766387

RESUMEN

BACKGROUND: Clinical efficacy of thrombolytic drugs is limited by lack of specific delivery and requires large therapeutic doses which increase toxicity. Encapsulating these drugs in temperature-sensitive liposomes and applying hyperthermia to deliver thrombolytic agents locally to thrombus might theoretically favourably alter the therapeutic window. The objectives of this study were to formulate liposomes encapsulating thrombolytics and assess thrombolytic activity following hyperthermia. METHODS: Three liposome formulations were investigated: temperature-sensitive liposome (TSL, DPPC:DSPE-PEG2000 (mol% 95:5)), low temperature-sensitive liposome (LTSL, DPPC:MSPC:DSPE-PEG2000 (mol% 85.3:9.7:5)), and traditional temperature-sensitive liposome (TTSL, DPPC:HSPC:Chol:DSPE-PEG2000 (mol% 55:25:15:5)). To characterise temperature-dependent release of high molecular weight cargo from each formulation, fluorescein-conjugated dextrans (70 kDa) were loaded and release was quantified via spectrophotometry. Staphylokinase (SAK), urokinase, and tissue-type plasminogen activator were also loaded individually into each liposome formulation. Leakage at 37 °C and release at 38-44 °C were quantified via chromogenic enzymatic activity assay. Clot lysis was evaluated by measuring mass of blood clots before and after thrombolytic liposome treatment. RESULTS: The LTSL formulation had optimal release characteristics with maximum release at 41.3 °C. Release of dextrans from LTSLs was observed to be 11.5 ± 1.5%, 79.7 ± 1.6%, and 93.6 ± 3.7% after 15 min in plasma at 37°, 39°, and 41.3 °C, respectively. The SAK LTSL had the highest release/leakage ratio and demonstrated greater clot lysis. CONCLUSIONS: The SAK LTSL achieves significant clot lysis in vitro. When combined with local hyperthermia, the SAK LTSL potentially produces sufficient thrombolysis while minimising systemic side effects.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Fibrinolíticos/administración & dosificación , Metaloendopeptidasas/administración & dosificación , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación , Humanos , Hipertermia Inducida , Lípidos/química , Liposomas , Masculino , Metaloendopeptidasas/química , Polietilenglicoles/química , Temperatura , Activador de Tejido Plasminógeno/química , Activador de Plasminógeno de Tipo Uroquinasa/química
13.
J Mater Sci Mater Med ; 26(6): 198, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26105830

RESUMEN

Therapeutic embolization of blood vessels is a minimally invasive, catheter-based procedure performed with solid or liquid emboli to treat bleeding, vascular malformations, and vascular tumors. Hepatocellular carcinoma (HCC) affects about half a million people per year. When unresectable, HCC is treated with embolization and local drug therapy by transarterial chemoembolization (TACE). For TACE, drug eluting beads (DC Bead(®)) may be used to occlude or reduce arterial blood supply and deliver chemotherapeutics locally to the tumor. Although this treatment has been shown to be safe and to improve patient survival, the procedure lacks imaging feedback regarding the location of embolic agent and drug coverage. To address this shortcoming, herein we report the synthesis and characterization of image-able drug eluting beads (iBeads) from the commercial DC Bead(®) product. Two different radiopaque beads were synthesized. In one approach, embolic beads were conjugated with 2,3,5-triiodobenzyl alcohol in the presence of 1,1'-carbonyldiimidazol to give iBead I. iBead II was synthesized with a similar approach but instead using a trimethylenediamine spacer and 2,3,5-triiodobenzoic acid. Doxorubicin was loaded into the iBeads II using a previously reported method. Size and shape of iBeads were evaluated using an upright microscope and their conspicuity assessed using a clinical CT and micro-CT. Bland and Dox-loaded iBeads II visualized with both clinical CT and microCT. Under microCT, individual bland and Dox loaded beads had a mean attenuation of 7904 ± 804 and 11,873.96 ± 706.12 HU, respectively. These iBeads have the potential to enhance image-guided TACE procedures by providing localization of embolic-particle and drug.


Asunto(s)
Quimioembolización Terapéutica/métodos , Medios de Contraste/química , Medios de Contraste/síntesis química , Antineoplásicos/administración & dosificación , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Diaminas/química , Doxorrubicina/administración & dosificación , Portadores de Fármacos/química , Sistemas de Liberación de Medicamentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Ensayo de Materiales , Microesferas , Fantasmas de Imagen , Alcohol Polivinílico/química , Ácidos Triyodobenzoicos/química , Microtomografía por Rayos X
14.
J Vasc Interv Radiol ; 25(5): 797-802, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24745908

RESUMEN

PURPOSE: To design, prototype, and assess a custom vascular access catheter for its ability to inhibit bacterial colonization in vitro and to optimize electric parameters for efficacy and safe translation. MATERIALS AND METHODS: A vascular access catheter with conductive elements was designed and custom fabricated with two electrodes at the tip, separated by a nonconductive segment. The catheter was colonized with Staphylococcus aureus and incubated at predetermined current levels (4-8 µA) and durations (4-24 h). Catheters were compared using bacterial counts and scanning electron microscopy (SEM). RESULTS: Bacteria colony-forming units were reduced significantly (P < .05) by > 90% (91.7%-100%) in all uninterrupted treatment arms that included electric current (4 µA or 8 µA) of at least 8 hours' duration. Qualitative analysis using SEM revealed that the treated catheter exposed to electric current had markedly less bacteria compared with the untreated catheter. CONCLUSIONS: This catheter with conductive elements inhibits bacterial colonization in vitro when very small electric current (4-8 µA) is applied across the tip for 8-24 hours. In vivo validation is requisite to future translation to the clinical setting.


Asunto(s)
Infecciones Relacionadas con Catéteres/prevención & control , Catéteres Venosos Centrales/microbiología , Estimulación Eléctrica/instrumentación , Contaminación de Equipos/prevención & control , Infecciones Estafilocócicas/prevención & control , Staphylococcus aureus/crecimiento & desarrollo , Esterilización/instrumentación , Infecciones Relacionadas con Catéteres/microbiología , Supervivencia Celular/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/efectos de la radiación
15.
Phys Med ; 122: 103382, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38820805

RESUMEN

PURPOSE: In this work, we define a signal detection based metrology to characterize the separability of two different multi-dimensional signals in spectral CT acquisitions. METHOD: Signal response was modelled as a random process with a deterministic signal and stochastic noise component. A linear Hotelling observer was used to estimate a scalar test statistic distribution that predicts the likelihood of an intensity value belonging to a signal. Two distributions were estimated for two materials of interest and used to derive two metrics separability: a separability index (s') and the area under the curve of the test statistic distributions. Experimental and simulated data of photon-counting CT scanners were used to evaluate each metric. Experimentally, vials of iodine and gadolinium (2, 4, 8 mg/mL) were scanned at multiple tube voltages, tube currents and energy thresholds. Additionally, a simulated dataset with low tube current (10-150 mAs) and material concentrations (0.25-4 mg/mL) was generated. RESULTS: Experimental data showed that conditions favorable for low noise and expression of k-edge signal produced the highest separability. Material concentration had the greatest impact on separability. The simulated data showed that under more difficult separation conditions, difference in material concentration still had the greatest impact on separability. CONCLUSION: The results demonstrate the utility of a task specific metrology to measure the overlap in signal between different materials in spectral CT. Using experimental and simulated data, the separability index was shown to describe the relationship between image formation factors and the signal responses of material.


Asunto(s)
Tomografía Computarizada por Rayos X , Yodo , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos , Gadolinio/química , Fantasmas de Imagen
16.
Phys Med Biol ; 69(14)2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38942009

RESUMEN

Objective.With the introduction of spectral CT techniques into the clinic, the imaging capacities of CT were expanded to multiple energy levels. Due to a variety of factors, the acquired signal in spectral CT datasets is shared between these images. Conventional image quality metrics assume independence between images which is not preserved within spectral CT datasets, limiting their utility for characterizing energy selective images. The purpose of this work was to develop a metrology to characterize energy selective images by incorporating the shared information between images within a spectral CT dataset.Approach.The signal-to-noise ratio (SNR) was extended into a multivariate space where each image within a spectral CT dataset was treated as a separate information channel. The general definition was applied to the specific case of contrast to define a multivariate contrast-to-noise ratio (CNR). The matrix contained two types of terms: a conventional CNR term which characterized image quality within each image in the spectral CT dataset and covariance weighted CNR (Covar-CNR) which characterized the contrast in each image relative to the covariance between images. Experimental data from an investigational photon-counting CT scanner was used to demonstrate the insight of this metrology. A cylindrical water phantom containing vials of iodine and gadolinium (2, 4, and 8 mg ml-1) was imaged under conditions of variable tube current, tube voltage, and energy threshold. Two image series (threshold and bin images) containing two images each were defined based upon the contribution of photons to reconstructed images. Analysis of variance (ANOVA) was calculated between CNR terms and image acquisition variables. A multivariate regression was then fitted to experimental data.Main Results.Image type had a major difference on how Covar-CNR values were distributed. Bin images had a slightly higher mean and wider standard deviation (Covar-CNRlo: 3.38 ±17.25, Covar-CNRhi: 5.77 ± 30.64) compared to threshold images (Covar-CNRlo: 2.08 ±1.89, Covar-CNRhi: 3.45 ± 2.49) across all conditions. ANOVA found that each acquisition variable had a significant relationship with both Covar-CNR terms. The multivariate regression model suggested that material concentration had the largest impact on all CNR terms.Signficance.In this work, we described a theoretical framework to extend the SNR to a multivariate form that is able to characterize images independently and also provide insight regarding the relationship between images. Experimental data was used to demonstrate the insight that this metrology provides about image formation factors in spectral CT.


Asunto(s)
Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Análisis Multivariante , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos
17.
Invest Radiol ; 57(8): 495-501, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35239613

RESUMEN

OBJECTIVES: The aims of this study were to develop a model to estimate drug dose delivered to tumors after transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEBs) based on DEB density on cone-beam computed tomography (CT) and to evaluate drug penetration into tissue in a woodchuck hepatoma model. MATERIALS AND METHODS: Transarterial chemoembolization was performed in woodchucks with hepatocellular carcinoma (N = 5) using DEBs (70-150 µm, LC Bead LUMI) loaded with doxorubicin. Livers were resected 45 minutes after embolization, immediately frozen, and cut using liver-specific, 3D-printed sectioning molds. Doxorubicin levels in tumor specimens were measured by high-performance liquid chromatography and correlated with DEB iodine content that was measured using prototype cone-beam CT-based embolization treatment planning software. Doxorubicin penetration into tissue surrounding DEBs was assessed by fluorescence microscopy of tumor sections. Fluorescence intensity was converted into doxorubicin concentration using calibration standards. Intensity-thresholded color heatmaps were generated representing extravascular drug penetration. RESULTS: Consistent segmentation of DEBs on cone-beam CT was achieved using a semiautomated intensity thresholding method. A positive linear correlation (0.96) was found between DEB iodine content measured on cone-beam CT and the amount of doxorubicin measured in tumor specimens. Prediction of doxorubicin levels in tumor sections that were not included in model development was accurate, with a root-mean-square error of 0.08 mg of doxorubicin. Tumor penetration of eluted doxorubicin resulted in concentration gradients where drug content decreased with increasing distance from blood vessels containing DEBs. Drug penetration was greater for blood vessels containing DEB clusters compared with single DEB, with higher doxorubicin concentrations extending further away from the vessels. CONCLUSIONS: Estimation of drug dose delivered during transarterial chemoembolization in a woodchuck hepatocellular carcinoma model was possible using DEB radiopacity on cone-beam CT as a surrogate marker. Doxorubicin penetration was greatest adjacent to vessels containing DEB clusters compared with single DEB. Intraprocedural estimation of the spatial distribution of drug dose within the tumor could enable real-time adjustments to DEB delivery, to maximize treatment coverage or identify regions of tumor at risk for undertreatment.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Yodo , Neoplasias Hepáticas , Animales , Antibióticos Antineoplásicos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Tomografía Computarizada de Haz Cónico/métodos , Doxorrubicina , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/terapia , Marmota , Resultado del Tratamiento
18.
Sci Rep ; 12(1): 21886, 2022 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-36535979

RESUMEN

Hepatocellular carcinoma (HCC) is an aggressive liver cancer with limited effective treatment options. In this study, we selected TLR agonists imiquimod (IMQ), gardiquimod (GARD), GS-9620 and DSR 6434, and a small molecule checkpoint inhibitor, BMS-202, for characterization of drug loading and release from radiopaque embolic beads (DC Bead LUMI) for potential use in image-guided transarterial embolization (TACE) of HCC. The maximum drug loading capacity and amount of drug released over time were determined by high performance liquid chromatography and compared with the commonly used anthracycline, doxorubicin hydrochloride (Dox). Maximum drug loading was 204.54 ± 3.87, 65.28 ± 3.09, 65.95 ± 6.96, 65.97 ± 1.54, and 148.05 ± 2.24 mg of drug per milliliter of DC Bead LUMI for Dox, GARD, DSR 6434, IMQ, and BMS-202, respectively. Fast loading and subsequent rapid release in saline were observed for IMQ, GARD, and DSR 6434. These drugs could also be partially removed from the beads by repeated washing with de-ionized water suggesting weak interaction with the beads. Aggregation of IMQ was observed in water and saline. GS-9620 partially decomposed in the solubilizing solution, so loading and release were not characterized. Compared to TLR agonists, slower loading and release were observed for Dox and BMS-202. Potential factors influencing drug loading into and release from DC Bead LUMI including steric hinderance, hydrophobicity, drug pKa, and the electrostatic nature of the beads are discussed. The maximum loading capacity of BMS-202 and Dox in DC Bead LUMI exceeded the maximum theoretical loading capacity of the beads expected from ionic interaction alone suggesting additional drug-bead or drug-drug interactions may play a role. Slightly more release was observed for BMS-202 at early time points followed by a slower release compared to Dox. Further study of these drug-bead combinations is warranted in search of new tools for locoregional delivery of immune-modulating agents for treatment of HCC via drug-eluting bead chemoembolization.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Quimioembolización Terapéutica/métodos , Doxorrubicina/química , Antibióticos Antineoplásicos/química , Microesferas
19.
Int J Pharm ; 616: 121466, 2022 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35065205

RESUMEN

Cancer immunotherapy has yet to reach its full potential due in part to limited response rates and side effects inherent to systemic delivery of immune-modulating drugs. Local administration of immunotherapy using drug-eluting embolic (DEE) microspheres as drug delivery vehicles for direct infusion into tumor-feeding arteries might increase and prolong tumor drug concentrations and reduce systemic drug exposure, potentially improving the risk-to-benefit ratio of these agents. The purpose of this study was to evaluate the ability of four immune modulators affecting two different immune pathways to potentiate replication of immune cells from a woodchuck model of hepatocellular carcinoma. DSR 6434, a Toll-like receptor agonist, and BMS-202, a PD-L1 checkpoint inhibitor, induced immune cell replication and were successfully loaded into radiopaque DEE microspheres in high concentrations. Release of DSR 6434 from the DEE microspheres was rapid (t99% = 0.4 h) upon submersion in a physiologic saline solution while BMS-202 demonstrated a more sustained release profile (t99% = 17.9 h). These findings demonstrate the feasibility of controlled delivery of immune-modulating drugs via a local DEE microsphere delivery paradigm.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica/efectos adversos , Doxorrubicina , Humanos , Neoplasias Hepáticas/patología , Microesferas , Preparaciones Farmacéuticas
20.
Int J Hyperthermia ; 27(2): 140-55, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21314334

RESUMEN

PURPOSE: Objectives of this study were to: 1) develop iLTSL, a low temperature sensitive liposome co-loaded with an MRI contrast agent (ProHance® Gd-HP-DO3A) and doxorubicin, 2) characterise doxorubicin and Gd-HP-DO3A release from iLTSL and 3) investigate the ability of magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) to induce and monitor iLTSL content release in phantoms and in vivo. METHODS: iLTSL was passively loaded with Gd-HP-DO3A and actively loaded with doxorubicin. Doxorubicin and Gd-HP-DO3A release was quantified by fluorescence and spectroscopic techniques, respectively. Release with MR-HIFU was examined in tissue-mimicking phantoms containing iLTSL and in a VX2 rabbit tumour model. RESULTS: iLTSL demonstrated consistent size and doxorubicin release kinetics after storage at 4°C for 7 days. Release of doxorubicin and Gd-HP-DO3A from iLTSL was minimal at 37°C but fast when heated to 41.3°C. The magnitude of release was not significantly different between doxorubicin and Gd-HP-DO3A over 10 min in HEPES buffer and plasma at 37°, 40° and 41.3°C (p > 0.05). Relaxivity of iLTSL increased significantly (p < 0.0001) from 1.95 ± 0.05 to 4.01 ± 0.1 mMs⁻¹ when heated above the transition temperature. Signal increase corresponded spatially and temporally to MR-HIFU-heated locations in phantoms. Signal increase was also observed in vivo after iLTSL injection and after each 10-min heating (41°C), with greatest increase in the heated tumour region. CONCLUSION: An MR imageable liposome formulation co-loaded with doxorubicin and an MR contrast agent was developed. Stability, imageability, and MR-HIFU monitoring and control of content release suggest that MR-HIFU combined with iLTSL may enable real-time monitoring and spatial control of content release.


Asunto(s)
Compuestos Heterocíclicos , Liposomas/administración & dosificación , Compuestos Organometálicos , Animales , Medios de Contraste , Doxorrubicina/administración & dosificación , Gadolinio , Humanos , Cinética , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética Intervencional , Fantasmas de Imagen , Conejos , Ultrasonografía Intervencional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA