Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
2.
Catheter Cardiovasc Interv ; 100(2): 179-187, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35621281

RESUMEN

INTRODUCTION: Long drug-eluting stents may limit the issue of overlapping multiple stents when treating long coronary lesions. AIM: The aim of the study was to assess the safety and efficacy of the 48 mm Xience Xpedition everolimus-eluting stent (48mm-EES) for the treatment of long coronary lesions, in an all-comer population. METHODS: Patients receiving at least one 48mm-EES were prospectively included from March 2014 to December 2018. The primary endpoint was target lesion failure (TLF), defined as a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization (TLR) at 1 year. The main secondary endpoint was the patient-oriented composite endpoint (POCE) defined as a composite of death, stroke, myocardial infarction, and reintervention. RESULTS: A total of 268 patients with 276 long coronary lesions, including 94 chronic total occlusions (CTO), were successfully treated using at least one 48mm-EES. The total stent length per lesion was 66 ± 22 mm. A single 48mm-EES was suitable to successfully treat the target lesion in 48% of cases (60% for non-CTO lesions). One-year follow-up rate was 96.3%. TLF occurred in 13 patients (5.3%), mainly driven by TLR (4.1%). Two cardiac death occurred (0.7%). POCE occurred in 30 patients (11.6%) mainly driven by repeat revascularization (9.7%). Definite stent thrombosis was observed in two patients (0.7%). No difference was observed in one-year outcomes between single 48mm-EES and multiple stents implantation as well as between CTO and non-CTO lesions. CONCLUSION: The 48mm-EES is safe and effective to treat long coronary lesions, including CTOs, and provides attractive cost-effectiveness by limiting multiple stenting.


Asunto(s)
Fármacos Cardiovasculares , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Fármacos Cardiovasculares/efectos adversos , Muerte , Everolimus/efectos adversos , Humanos , Estimación de Kaplan-Meier , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Sirolimus , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 95(2): 175-184, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31033154

RESUMEN

OBJECTIVES: To assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disease (MVD) enrolled in the CENTURY II trial. BACKGROUND: The use of coronary stenting in high-risk subgroups, like MVD patients, is rising. The clinical evidence, including long-term comparative analysis of the efficacy and safety benefits of different new-generation drug eluting stents, however, remains insufficient. METHODS: Among 1,119 patients (intention-to-treat) enrolled in the CENTURY II prospective, randomized, single-blind, multicenter trial, a prespecified subgroup of 456 MVD patients were allocated by stratified randomization to treatment with BP-SES (n = 225) or PP-EES (n = 231). The previously reported primary endpoint of this study was freedom from target lesion failure (TLF: a composite of cardiac death, target vessel-related myocardial infarction [MI] and clinically-indicated target lesion revascularization) at 9 months. RESULTS: In this MVD substudy, baseline patient, lesion and procedure characteristics were similar between the treatment arms. At 1 and 5 years, both BP-SES and PP-EES displayed low and comparable rates of TLF (5.3 vs. 7.8%; p = .29 and 10.2 vs. 13.4%; p = .29), and definite or probable stent thrombosis (0.4 vs. 1.3%; p = .33 and 0.9 vs. 1.7%; p = .43), respectively. Composite endpoint of cardiac death and MI, and patient-oriented composite endpoint of any death, MI, and coronary revascularizations were also similar. CONCLUSIONS: These results confirm good long-term safety and efficacy of the studied bioresorbable polymer stent in this high-risk patient population.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Europa (Continente) , Everolimus/efectos adversos , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31713325

RESUMEN

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio/trasplante , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Irlanda , Masculino , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
5.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30394657

RESUMEN

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Irlanda , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Reino Unido
6.
Catheter Cardiovasc Interv ; 90(2): 350-353, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27028012

RESUMEN

This case report describes the percutaneous closure of a complex coronary artery fistula through the successful deployment of a vascular plug. It particularly highlights the technical challenges of percutaneously treating complex distal-type fistulae. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Dispositivos de Cierre Vascular , Fístula Vascular/terapia , Anciano , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen
7.
J Endovasc Ther ; 23(6): 880-888, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27558461

RESUMEN

PURPOSE: To compare the procedure and safety outcomes of the transradial approach (TRA) with the femoral approach (FA) for treating aortoiliac and femoropopliteal stenoses and occlusions. METHODS: A single-center retrospective study was conducted involving 188 patients (mean age 66.4±10.8 years; 116 men) with lower limb claudication or critical limb ischemia who underwent aortoiliac (131, 62.4%) or femoropopliteal (79, 37.6%) interventions on 210 lesions over a 3-year period. Operator discretion determined TRA suitability; exclusions included Raynaud's disease, upper limb occlusive disease, previous TRA difficulties, or planned hemodialysis. Lesion characteristics, clinical endpoints, and access site complications were compared. RESULTS: FA was used primarily in 123 patients and the TRA (12 left and 53 right radial arteries) in 65 procedures. Eleven (16.9%) TRAs failed vs 9 (7.3%) FAs (p=0.42). Crossover to FA was due to occlusive lesions requiring alternative equipment in 9 cases and to tortuosity of the aortic arch vessels in 2 patients. The 134 FA interventions (balloon angioplasty, stents) were retrograde (112, 83.6%) or antegrade (22, 16.4%). There were significantly more TASC C/D lesions in the FA group (p=0.02). Sheath sizes (5-F to 8-F) did not differ between groups, and no significant differences were found between FA vs TRA in terms of procedure time (50.0±28.9 vs 46.8±25.1 minutes, p=0.50) or length of stay (2.2±0.6 vs 2.1±0.3 days, p=0.24). While there were no strokes, access site complications occurred in 6.0% of the FA patients vs 3.7% of the TRA patients (p=0.12). CONCLUSION: The transradial approach for aortoiliac and femoropopliteal interventions is safe and efficacious compared with the transfemoral approach for a range of lesion subtypes. Nevertheless, there remains a need for improvements in peripheral device and catheter technology to decrease transradial failure rates.


Asunto(s)
Angioplastia de Balón , Constricción Patológica/cirugía , Arteria Poplítea/cirugía , Stents , Anciano , Arteria Femoral/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Clin Med ; 13(18)2024 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-39336957

RESUMEN

Stroke following transcatheter aortic valve replacement (TAVR) is a significant and life-threatening adverse event. The vast majority of these incidents occur during the TAVR procedure or within the first 24 h following TAVR, with a notable prevalence of cerebral embolic events. In response to this concern, cerebral embolic protection devices (CEPDs) have been designed to mitigate the risk of peri-procedural ischemic stroke during TAVR. The primary objective of CEPDs is to diminish the intraprocedural burden associated with new silent ischemic brain injuries. Despite the development of several CEPDs, their clinical efficacy remains uncertain. In this review, we delve into a comprehensive analysis of the utilization of CEPDs in patients undergoing TAVR, exploring insights from the existing literature. Additionally, we aim to present future perspectives and discuss the clinical implications associated with the incorporation of CEPDs in TAVR procedures.

9.
Artículo en Inglés | MEDLINE | ID: mdl-38262740

RESUMEN

BACKGROUND AND AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing transcatheter aortic valve intervention (TAVI). METHODS: We followed the European Society of Cardiology (ESC) methodology for the development of QIs. Key domains were identified by constructing a conceptual framework for the delivery of TAVI care. A list of candidate QIs were developed by conducting a systematic review of the literature. A modified Delphi method was then used to select the final set of QIs. Finally, we mapped the QIs to the EuroHeart Data Standards for TAVI to ascertain the extent to which the EuroHeart TAVI registry captures information to calculate the QIs. RESULTS: We formed an international group of experts in quality improvement and TAVI, including representatives from the European Association of Percutaneous Cardiovascular Interventions, the European Association of Cardiovascular Imaging and the Association of Cardiovascular Nursing & Allied Professions. In total, 27 QIs were selected across eight domains of TAVI care, comprising 22 main (81%) and five secondary (19%) QIs. Of these, 19/27 (70%) are now being utilised in the EuroHeart TAVI registry. CONCLUSION: We present the 2023 ESC QIs for TAVI, developed using a standard methodology and in collaboration with ESC Associations. The EuroHeart TAVI registry allows calculation of the majority of the QIs, which may be used for benchmarking care and quality improvement initiatives.

10.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726720

RESUMEN

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Asunto(s)
Consenso , Hemorragia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Hemorragia/etiología , Medición de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA