Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Microbiol ; 60(8): e0015522, 2022 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-35861529

RESUMEN

The Truenat MTB Plus assay is a rapid molecular test that has been recommended by the World Health Organization since 2020 as an initial test to detect tuberculosis (TB). The WHO highlighted the need to further evaluate assay performance to inform future recommendations, including in people living with HIV and compared to the Xpert MTB/RIF assay. We conducted a prospective evaluation of the diagnostic accuracy of the Truenat assay in Cameroon, a country with a high burden of HIV/TB. Adult outpatients were recruited at four hospitals; demographic information and medical history were collected, and participants produced two sputum specimens. Truenat and Xpert testing was performed on the same specimen, and performance was compared to TB culture as the reference standard. From November 2019 to December 2020, 945 participants were enrolled and included in the analysis. Among 251 participants with culture-positive TB, the sensitivity of Truenat MTB Plus was 91% (95% confidence interval [CI], 86 to 94%), similar to Xpert (90%; 95% CI, 86 to 93%). Among 74 HIV-positive participants with culture-positive TB, the sensitivity of Truenat MTB Plus was 85% (95% CI, 75 to 92%) compared to 81% for Xpert (95% CI, 70 to 89%). Among 47 participants with smear-negative TB, the sensitivity of Truenat MTB Plus was 55% (95% CI, 40 to 70%), similar to Xpert (53%; 95% CI, 38 to 68%). The specificity of Truenat MTB Plus was 96% (95% CI, 94 to 97%) compared to 99% (95% CI, 97 to 99%) for Xpert. For TB detection compared to the reference standard of TB culture, the performance of the Truenat MTB Plus assay was similar to that of Xpert in this population, including among people living with HIV.


Asunto(s)
Infecciones por VIH , Mycobacterium tuberculosis , Tuberculosis Pulmonar , Tuberculosis , Adulto , Camerún , Farmacorresistencia Bacteriana , Infecciones por VIH/complicaciones , Infecciones por VIH/epidemiología , Hospitales , Humanos , Mycobacterium tuberculosis/genética , Pacientes Ambulatorios , Rifampin , Sensibilidad y Especificidad , Esputo , Tuberculosis/diagnóstico , Tuberculosis Pulmonar/diagnóstico
2.
ERJ Open Res ; 10(3)2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38803415

RESUMEN

The Lung Flute ECO, a self-powered, low-cost oscillatory positive expiratory pressure device, assisted people with presumptive tuberculosis to produce an adequate sputum volume for diagnostic testing and was well tolerated https://bit.ly/47sDq8W.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA