Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(5): 907-914, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29368394

RESUMEN

OBJECTIVES: We assess the mid-term outcomes of ultrathin biodegradable polymer double stenting using a very minimal crushing (Nano-Crush) technique in large complex coronary bifurcation. BACKGROUND: Complex bifurcations have been suggested to be better approached by a planned double stent technique. METHODS: Two hundred and five consecutive patients (107 males and 98 females) referred for large complex coronary bifurcation percutaneous coronary interventions were enrolled. The technique was also evaluated by both a bench test with a silicon tubes phantom resembling a coronary bifurcation and a computed fluid dynamic (CFD) analysis. RESULTS: Left main bifurcation accounted for 40.9% of cases (84 patients). Mean angles between main branch (MB) and side branch (SB) were 63.6 ± 21.3°. SB intravascular ultrasound-calculated MSA was 5.6 ± 1.5 mm2 . Clinical follow-up was available for 100% of patients and at a mean follow-up of 16.2 ± 6.7 months 8 deaths, all due to cardiovascular reason, (3.9%, 4 patients for stroke, two for heart failure, one after surgical aortic valve substitution, and one after acute massive pulmonary embolism) and no presumptive stent thrombosis or target vessel induced ischemia were observed. Angiographic follow-up was available in 108 patients (52.7%) and showed a very low significant restenosis (5 patients, 4.6%). Bench study and CFD evaluation suggested a complete coverage of the SB ostium with a very high strut-free area at the SB. CONCLUSIONS: The revascularization of complex large coronary bifurcation disease using the Nano-crush technique appeared promising thanks to the favorable fluid dynamic profile, complete coverage of the SD ostium, and very small metal amount at the carina.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Simulación por Computador , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Femenino , Humanos , Hidrodinámica , Masculino , Ensayo de Materiales , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA