Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Med ; 21(1): 383, 2023 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-37794461

RESUMEN

BACKGROUND: An increased number of resources are allocated on cancer biomarker discovery, but very few of these biomarkers are clinically adopted. To bridge the gap between Biomarker discovery and clinical use, we aim to generate the Biomarker Toolkit, a tool designed to identify clinically promising biomarkers and promote successful biomarker translation. METHODS: All features associated with a clinically useful biomarker were identified using mixed-methodology, including systematic literature search, semi-structured interviews, and an online two-stage Delphi-Survey. Validation of the checklist was achieved by independent systematic literature searches using keywords/subheadings related to clinically and non-clinically utilised breast and colorectal cancer biomarkers. Composite aggregated scores were generated for each selected publication based on the presence/absence of an attribute listed in the Biomarker Toolkit checklist. RESULTS: Systematic literature search identified 129 attributes associated with a clinically useful biomarker. These were grouped in four main categories including: rationale, clinical utility, analytical validity, and clinical validity. This checklist was subsequently developed using semi-structured interviews with biomarker experts (n=34); and 88.23% agreement was achieved regarding the identified attributes, via the Delphi survey (consensus level:75%, n=51). Quantitative validation was completed using clinically and non-clinically implemented breast and colorectal cancer biomarkers. Cox-regression analysis suggested that total score is a significant driver of biomarker success in both cancer types (BC: p>0.0001, 95.0% CI: 0.869-0.935, CRC: p>0.0001, 95.0% CI: 0.918-0.954). CONCLUSIONS: This novel study generated a validated checklist with literature-reported attributes linked with successful biomarker implementation. Ultimately, the application of this toolkit can be used to detect biomarkers with the highest clinical potential and shape how biomarker studies are designed/performed.


Asunto(s)
Investigación Biomédica , Neoplasias Colorrectales , Humanos , Biomarcadores de Tumor/genética , Lista de Verificación , Neoplasias Colorrectales/diagnóstico
2.
Thorax ; 75(8): 632-639, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32409613

RESUMEN

INTRODUCTION: Individuals with chronic lung disease (eg, cystic fibrosis (CF)) often receive antimicrobial therapy including aminoglycosides resulting in ototoxicity. Extended high-frequency audiometry has increased sensitivity for ototoxicity detection, but diagnostic audiometry in a sound-booth is costly, time-consuming and requires a trained audiologist. This cross-sectional study analysed tablet-based audiometry (Shoebox MD) performed by non-audiologists in an outpatient setting, alongside home web-based audiometry (3D Tune-In) to screen for hearing loss in adults with CF. METHODS: Hearing was analysed in 126 CF adults using validated questionnaires, a web self-hearing test (0.5 to 4 kHz), tablet (0.25 to 12 kHz) and sound-booth audiometry (0.25 to 12 kHz). A threshold of ≥25 dB hearing loss at ≥1 audiometric frequency was considered abnormal. Demographics and mitochondrial DNA sequencing were used to analyse risk factors, and accuracy and usability of hearing tests determined. RESULTS: Prevalence of hearing loss within any frequency band tested was 48%. Multivariate analysis showed age (OR 1.127; (95% CI: 1.07 to 1.18; p value<0.0001) per year older) and total intravenous antibiotic days over 10 years (OR 1.006; (95% CI: 1.002 to 1.010; p value=0.004) per further intravenous day) were significantly associated with increased risk of hearing loss. Tablet audiometry had good usability, was 93% sensitive, 88% specific with 94% negative predictive value to screen for hearing loss compared with web self-test audiometry and questionnaires which had poor sensitivity (17% and 13%, respectively). Intraclass correlation (ICC) of tablet versus sound-booth audiometry showed high correlation (ICC >0.9) at all frequencies ≥4 kHz. CONCLUSIONS: Adults with CF have a high prevalence of drug-related hearing loss and tablet-based audiometry can be a practical, accurate screening tool within integrated ototoxicity monitoring programmes for early detection.


Asunto(s)
Fibrosis Quística/complicaciones , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/epidemiología , Adulto , Audiometría , Computadoras de Mano , Estudios Transversales , Fibrosis Quística/terapia , Femenino , Humanos , Internet , Masculino , Persona de Mediana Edad , Prevalencia , Factores de Riesgo , Adulto Joven
3.
PLoS One ; 18(7): e0288126, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37440504

RESUMEN

Innovating in Medical Device (MD) industry is challenging. This study aims to develop and validate an evidence-based framework that helps innovators of small and large enterprises (SEs and LEs) assess their readiness for successful MD development and deployment. We conducted a key-informant process (stage 1) where 25 international experts identified a list of emergent Health Technology Assessment (HTA) themes they believed were essential to company success. A sample of 22 European and US selected companies (13 SEs and 9 LEs) then reached a consensus on a list of key themes through a robust Delphi process (stage 2). Finally, we constructed (stage 3) and validated (stage 4) the checklist for SEs and LEs. The checklist for SEs and LEs included 21 and 15 items (i.e., fundamental Yes/No questions) with nine overlapping criteria for both SEs and LEs. In both groups, MD success was driven by three major item categories: (i) R&D assessment strategy; (ii) device-outcome measures; (iii) company profiling. Alongside the retrospective validation study, we collected 40 case studies on MDs (23 successes and 17 failures) across the selected enterprises. The retrospective validation provided the proportion of successful and failed case studies that met the 'MeDKET' criteria. We discovered that early HTA plays a pivotal role in MD industry success with different implications based on enterprise size. This study is the first of its kind to provide a holistic picture of the perceived role of early-stage HTA in MD industry success.


Asunto(s)
Industrias , Evaluación de la Tecnología Biomédica , Estudios Retrospectivos , Consenso , Lista de Verificación
4.
BMJ Open ; 11(4): e042944, 2021 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-33849848

RESUMEN

OBJECTIVES: This study investigated the barriers and facilitators to the adoption of point-of-care tests (POCTs). DESIGN: Qualitative study incorporating a constant comparative analysis of stakeholder responses to a series of interviews undertaken to design the Point-of-Care Key Evidence Tool. SETTING: The study was conducted in relation to POCTs used in all aspects of healthcare. PARTICIPANTS: Forty-three stakeholders were interviewed including clinicians (incorporating laboratory staff and members of trust POCT committees), commissioners, industry, regulators and patients. RESULTS: Thematic analysis highlighted 32 barriers in six themes and 28 facilitators in eight themes to the adoption of POCTs. Six themes were common to both barriers and facilitators (clinical, cultural, evidence, design and quality assurance, financial and organisational) and two themes contained facilitators alone (patient factors and other (non-financial) resource use). CONCLUSIONS: Findings from this study demonstrate the complex motivations of stakeholders in the adoption of POCT. Most themes were common to both barriers and facilitators suggesting that good device design, stakeholder engagement and appropriate evidence provision can increase the likelihood of a POCT device adoption. However, it is important to realise that while the majority of identified barriers may be perceived or mitigated some may be absolute and if identified early in device development further investment should be carefully considered.


Asunto(s)
Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Atención a la Salud , Humanos , Investigación Cualitativa , Reino Unido
5.
BMJ Open ; 7(11): e018128, 2017 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-29102995

RESUMEN

OBJECTIVES: The existing British National Patient Safety Agency (NPSA) safety guideline recommends testing the pH of nasogastric (NG) tube aspirates. Feeding is considered safe if a pH of 5.5 or lower has been observed; otherwise chest X-rays are recommended. Our previous research found that at 5.5, the pH test lacks sensitivity towards oesophageal placements, a major risk identified by feeding experts. The aim of this research is to use a decision analytic modelling approach to systematically assess the safety of the pH test under cut-offs 1-9. MATERIALS AND METHODS: We mapped out the care pathway according to the existing safety guideline where the pH test is used as a first-line test, followed by chest x-rays. Decision outcomes were scored on a 0-100 scale in terms of safety. Sensitivities and specificities of the pH test at each cut-off were extracted from our previous research. Aggregating outcome scores and probabilities resulted in weighted scores which enabled an analysis of the relative safety of the checking procedure under various pH cut-offs. RESULTS: The pH test was the safest under cut-off 5 when there was ≥30% of NG tube misplacements. Under cut-off 5, respiratory feeding was excluded; oesophageal feeding was kept to a minimum to balance the need of chest X-rays for patients with a pH higher than 5. Routine chest X-rays were less safe than the pH test while to feed all without safety checks was the most risky. DISCUSSION: The safety of the current checking procedure is sensitive to the choice of pH cut-offs, the impact of feeding delays, the accuracy of the pH in the oesophagus, as well as the extent of tube misplacements. CONCLUSIONS: The pH test with 5 as the cut-off was the safest overall. It is important to understand the local clinical environment so that appropriate choice of pH cut-offs can be made to maximise safety and to minimise the use of chest X-rays. TRIAL REGISTRATION NUMBER: ISRCTN11170249; Pre-results.


Asunto(s)
Técnicas de Apoyo para la Decisión , Concentración de Iones de Hidrógeno , Intubación Gastrointestinal , Recolección de Datos , Nutrición Enteral , Humanos , Seguridad del Paciente , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA