Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiother Oncol ; 83(2): 156-62, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17493699

RESUMEN

BACKGROUND AND PURPOSE: The study aimed to examine specific avoidance of functional lung (FL) defined by a single photon emission computerized tomography (SPECT) lung perfusion scan, using intensity modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3-DCRT) in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Patients with NSCLC underwent planning computerized tomography (CT) and lung perfusion SPECT scan in the treatment position using fiducial markers to allow co-registration in the treatment planning system. Radiotherapy (RT) volumes were delineated on the CT scan. FL was defined using co-registered SPECT images. Two inverse coplanar RT plans were generated for each patient: 4-field 3-DCRT and 5-field step-and-shoot IMRT. 3-DCRT plans were created using automated AutoPlan optimisation software, and IMRT plans were generated employing Pinnacle(3) treatment planning system (Philips Radiation Oncology Systems). All plans were prescribed to 64 Gy in 32 fractions using data for the 6 MV beam from an Elekta linear accelerator. The objectives for both plans were to minimize the volume of FL irradiated to 20 Gy (fV(20)) and dose variation within the planning target volume (PTV). A spinal cord dose was constrained to 46 Gy. Volume of PTV receiving 90% of the prescribed dose (PTV(90)), fV(20), and functional mean lung dose (fMLD) were recorded. The PTV(90)/fV(20) ratio was used to account for variations in both measures, where a higher value represented a better plan. RESULTS: Thirty-four RT plans of 17 patients with stage I-IIIB NSCLC suitable for radical RT were analysed. In 6 patients with stage I-II disease there was no improvement in PTV(90), fV(20), PTV/fV(20) ratio and fMLD using IMRT compared to 3-DCRT. In 11 patients with stage IIIA-B disease, the PTV was equally well covered with IMRT and 3-DCRT plans, with IMRT producing better PTV(90)/fV(20) ratio (mean ratio - 7.2 vs. 5.3, respectively, p=0.001) and reduced fMLD figures compared to 3-DCRT (mean value - 11.5 vs. 14.3 Gy, p=0.001). This was due to reduction in fV(20) while maintaining PTV coverage. CONCLUSION: The use of IMRT compared to 3-DCRT improves the avoidance of FL defined by perfusion SPECT scan in selected patients with locally advanced NSCLC. If the dose to FL is shown to be the primary determinant of lung toxicity, IMRT would allow for effective dose escalation by specific avoidance of FL.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Radioterapia de Intensidad Modulada/efectos adversos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Masculino , Estadificación de Neoplasias , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Tasa de Supervivencia , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA