RESUMEN
Maturation of the human fetal brain should follow precisely scheduled structural growth and folding of the cerebral cortex for optimal postnatal function1. We present a normative digital atlas of fetal brain maturation based on a prospective international cohort of healthy pregnant women2, selected using World Health Organization recommendations for growth standards3. Their fetuses were accurately dated in the first trimester, with satisfactory growth and neurodevelopment from early pregnancy to 2 years of age4,5. The atlas was produced using 1,059 optimal quality, three-dimensional ultrasound brain volumes from 899 of the fetuses and an automated analysis pipeline6-8. The atlas corresponds structurally to published magnetic resonance images9, but with finer anatomical details in deep grey matter. The between-study site variability represented less than 8.0% of the total variance of all brain measures, supporting pooling data from the eight study sites to produce patterns of normative maturation. We have thereby generated an average representation of each cerebral hemisphere between 14 and 31 weeks' gestation with quantification of intracranial volume variability and growth patterns. Emergent asymmetries were detectable from as early as 14 weeks, with peak asymmetries in regions associated with language development and functional lateralization between 20 and 26 weeks' gestation. These patterns were validated in 1,487 three-dimensional brain volumes from 1,295 different fetuses in the same cohort. We provide a unique spatiotemporal benchmark of fetal brain maturation from a large cohort with normative postnatal growth and neurodevelopment.
Asunto(s)
Encéfalo , Desarrollo Fetal , Feto , Preescolar , Femenino , Humanos , Embarazo , Encéfalo/anatomía & histología , Encéfalo/embriología , Encéfalo/crecimiento & desarrollo , Feto/embriología , Edad Gestacional , Sustancia Gris/anatomía & histología , Sustancia Gris/embriología , Sustancia Gris/crecimiento & desarrollo , Voluntarios Sanos , Internacionalidad , Imagen por Resonancia Magnética , Tamaño de los Órganos , Estudios Prospectivos , Organización Mundial de la Salud , Imagenología Tridimensional , UltrasonografíaRESUMEN
BACKGROUND: Artificial intelligence (AI) for ultrasound scanning in regional anaesthesia is a rapidly developing interdisciplinary field. There is a risk that work could be undertaken in parallel by different elements of the community but with a lack of knowledge transfer between disciplines, leading to repetition and diverging methodologies. This scoping review aimed to identify and map the available literature on the accuracy and utility of AI systems for ultrasound scanning in regional anaesthesia. METHODS: A literature search was conducted using Medline, Embase, CINAHL, IEEE Xplore, and ACM Digital Library. Clinical trial registries, a registry of doctoral theses, regulatory authority databases, and websites of learned societies in the field were searched. Online commercial sources were also reviewed. RESULTS: In total, 13,014 sources were identified; 116 were included for full-text review. A marked change in AI techniques was noted in 2016-17, from which point on the predominant technique used was deep learning. Methods of evaluating accuracy are variable, meaning it is impossible to compare the performance of one model with another. Evaluations of utility are more comparable, but predominantly gained from the simulation setting with limited clinical data on efficacy or safety. Study methodology and reporting lack standardisation. CONCLUSIONS: There is a lack of structure to the evaluation of accuracy and utility of AI for ultrasound scanning in regional anaesthesia, which hinders rigorous appraisal and clinical uptake. A framework for consistent evaluation is needed to inform model evaluation, allow comparison between approaches/models, and facilitate appropriate clinical adoption.
Asunto(s)
Anestesia de Conducción , Inteligencia Artificial , Humanos , Ultrasonografía , Simulación por Computador , Bases de Datos FactualesRESUMEN
BACKGROUND: Ultrasonound is used to identify anatomical structures during regional anaesthesia and to guide needle insertion and injection of local anaesthetic. ScanNav Anatomy Peripheral Nerve Block (Intelligent Ultrasound, Cardiff, UK) is an artificial intelligence-based device that produces a colour overlay on real-time B-mode ultrasound to highlight anatomical structures of interest. We evaluated the accuracy of the artificial-intelligence colour overlay and its perceived influence on risk of adverse events or block failure. METHODS: Ultrasound-guided regional anaesthesia experts acquired 720 videos from 40 volunteers (across nine anatomical regions) without using the device. The artificial-intelligence colour overlay was subsequently applied. Three more experts independently reviewed each video (with the original unmodified video) to assess accuracy of the colour overlay in relation to key anatomical structures (true positive/negative and false positive/negative) and the potential for highlighting to modify perceived risk of adverse events (needle trauma to nerves, arteries, pleura, and peritoneum) or block failure. RESULTS: The artificial-intelligence models identified the structure of interest in 93.5% of cases (1519/1624), with a false-negative rate of 3.0% (48/1624) and a false-positive rate of 3.5% (57/1624). Highlighting was judged to reduce the risk of unwanted needle trauma to nerves, arteries, pleura, and peritoneum in 62.9-86.4% of cases (302/480 to 345/400), and to increase the risk in 0.0-1.7% (0/160 to 8/480). Risk of block failure was reported to be reduced in 81.3% of scans (585/720) and to be increased in 1.8% (13/720). CONCLUSIONS: Artificial intelligence-based devices can potentially aid image acquisition and interpretation in ultrasound-guided regional anaesthesia. Further studies are necessary to demonstrate their effectiveness in supporting training and clinical practice. CLINICAL TRIAL REGISTRATION: NCT04906018.
Asunto(s)
Anestesia de Conducción , Bloqueo Nervioso , Humanos , Bloqueo Nervioso/métodos , Inteligencia Artificial , Ultrasonografía Intervencional/métodos , Anestesia de Conducción/métodos , UltrasonografíaRESUMEN
BACKGROUND: Ultrasound-guided regional anaesthesia relies on the visualisation of key landmark, target, and safety structures on ultrasound. However, this can be challenging, particularly for inexperienced practitioners. Artificial intelligence (AI) is increasingly being applied to medical image interpretation, including ultrasound. In this exploratory study, we evaluated ultrasound scanning performance by non-experts in ultrasound-guided regional anaesthesia, with and without the use of an assistive AI device. METHODS: Twenty-one anaesthetists, all non-experts in ultrasound-guided regional anaesthesia, underwent a standardised teaching session in ultrasound scanning for six peripheral nerve blocks. All then performed a scan for each block; half of the scans were performed with AI assistance and half without. Experts assessed acquisition of the correct block view and correct identification of sono-anatomical structures on each view. Participants reported scan confidence, experts provided a global rating score of scan performance, and scans were timed. RESULTS: Experts assessed 126 ultrasound scans. Participants acquired the correct block view in 56/62 (90.3%) scans with the device compared with 47/62 (75.1%) without (P=0.031, two data points lost). Correct identification of sono-anatomical structures on the view was 188/212 (88.8%) with the device compared with 161/208 (77.4%) without (P=0.002). There was no significant overall difference in participant confidence, expert global performance score, or scan time. CONCLUSIONS: Use of an assistive AI device was associated with improved ultrasound image acquisition and interpretation. Such technology holds potential to augment performance of ultrasound scanning for regional anaesthesia by non-experts, potentially expanding patient access to these techniques. CLINICAL TRIAL REGISTRATION: NCT05156099.
Asunto(s)
Anestesia de Conducción , Bloqueo Nervioso , Humanos , Bloqueo Nervioso/métodos , Inteligencia Artificial , Ultrasonografía Intervencional/métodos , Anestesia de Conducción/métodos , UltrasonografíaRESUMEN
BACKGROUND: Gestational hypertensive and acute hypotensive disorders are associated with maternal morbidity and mortality worldwide. However, physiological blood pressure changes in pregnancy are insufficiently defined. We describe blood pressure changes across healthy pregnancies from the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) Fetal Growth Longitudinal Study (FGLS) to produce international, gestational age-specific, smoothed centiles (third, 10th, 50th, 90th, and 97th) for blood pressure. METHODS AND FINDINGS: Secondary analysis of a prospective, longitudinal, observational cohort study (2009 to 2016) was conducted across 8 diverse urban areas in Brazil, China, India, Italy, Kenya, Oman, the United Kingdom, and the United States of America. We enrolled healthy women at low risk of pregnancy complications. We measured blood pressure using standardised methodology and validated equipment at enrolment at <14 weeks, then every 5 ± 1 weeks until delivery. We enrolled 4,607 (35%) women of 13,108 screened. The mean maternal age was 28·4 (standard deviation [SD] 3.9) years; 97% (4,204/4,321) of women were married or living with a partner, and 68% (2,955/4,321) were nulliparous. Their mean body mass index (BMI) was 23.3 (SD 3.0) kg/m2. Systolic blood pressure was lowest at 12 weeks: Median was 111.5 (95% CI 111.3 to 111.8) mmHg, rising to a median maximum of 119.6 (95% CI 118.9 to 120.3) mmHg at 40 weeks' gestation, a difference of 8.1 (95% CI 7.4 to 8.8) mmHg. Median diastolic blood pressure decreased from 12 weeks: 69.1 (95% CI 68.9 to 69.3) mmHg to a minimum of 68.5 (95% CI 68.3 to 68.7) mmHg at 19+5 weeks' gestation, a change of -0·6 (95% CI -0.8 to -0.4) mmHg. Diastolic blood pressure subsequently increased to a maximum of 76.3 (95% CI 75.9 to 76.8) mmHg at 40 weeks' gestation. Systolic blood pressure fell by >14 mmHg or diastolic blood pressure by >11 mmHg in fewer than 10% of women at any gestational age. Fewer than 10% of women increased their systolic blood pressure by >24 mmHg or diastolic blood pressure by >18 mmHg at any gestational age. The study's main limitations were the unavailability of prepregnancy blood pressure values and inability to explore circadian effects because time of day was not recorded for the blood pressure measurements. CONCLUSIONS: Our findings provide international, gestational age-specific centiles and limits of acceptable change to facilitate earlier recognition of deteriorating health in pregnant women. These centiles challenge the idea of a clinically significant midpregnancy drop in blood pressure.
Asunto(s)
Presión Sanguínea/fisiología , Desarrollo Fetal/fisiología , Edad Gestacional , Adulto , Brasil , Preescolar , China , Femenino , Humanos , India , Italia , Kenia , Estudios Longitudinales , Ultrasonografía Prenatal/métodos , Reino Unido , Adulto JovenRESUMEN
BACKGROUND: Human growth is susceptible to damage from insults, particularly during periods of rapid growth. Identifying those periods and the normative limits that are compatible with adequate growth and development are the first key steps toward preventing impaired growth. OBJECTIVE: This study aimed to construct international fetal growth velocity increment and conditional velocity standards from 14 to 40 weeks' gestation based on the same cohort that contributed to the INTERGROWTH-21st Fetal Growth Standards. STUDY DESIGN: This study was a prospective, longitudinal study of 4321 low-risk pregnancies from 8 geographically diverse populations in the INTERGROWTH-21st Project with rigorous standardization of all study procedures, equipment, and measurements that were performed by trained ultrasonographers. Gestational age was accurately determined clinically and confirmed by ultrasound measurement of crown-rump length at <14 weeks' gestation. Thereafter, the ultrasonographers, who were masked to the values, measured the fetal head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length in triplicate every 5 weeks (within 1 week either side) using identical ultrasound equipment at each site (4-7 scans per pregnancy). Velocity increments across a range of intervals between measures were modeled using fractional polynomial regression. RESULTS: Peak velocity was observed at a similar gestational age: 16 and 17 weeks' gestation for head circumference (12.2 mm/wk), and 16 weeks' gestation for abdominal circumference (11.8 mm/wk) and femur length (3.2 mm/wk). However, velocity growth slowed down rapidly for head circumference, biparietal diameter, occipitofrontal diameter, and femur length, with an almost linear reduction toward term that was more marked for femur length. Conversely, abdominal circumference velocity remained relatively steady throughout pregnancy. The change in velocity with gestational age was more evident for head circumference, biparietal diameter, occipitofrontal diameter, and femur length than for abdominal circumference when the change was expressed as a percentage of fetal size at 40 weeks' gestation. We have also shown how to obtain accurate conditional fetal velocity based on our previous methodological work. CONCLUSION: The fetal skeleton and abdomen have different velocity growth patterns during intrauterine life. Accordingly, we have produced international Fetal Growth Velocity Increment Standards to complement the INTERGROWTH-21st Fetal Growth Standards so as to monitor fetal well-being comprehensively worldwide. Fetal growth velocity curves may be valuable if one wants to study the pathophysiology of fetal growth. We provide an application that can be used easily in clinical practice to evaluate changes in fetal size as conditional velocity for a more refined assessment of fetal growth than is possible at present (https://lxiao5.shinyapps.io/fetal_growth/). The application is freely available with the other INTERGROWTH-21st tools at https://intergrowth21.tghn.org/standards-tools/.
Asunto(s)
Abdomen/embriología , Fémur/embriología , Desarrollo Fetal , Edad Gestacional , Cabeza/embriología , Abdomen/diagnóstico por imagen , Adulto , Largo Cráneo-Cadera , Femenino , Fémur/diagnóstico por imagen , Gráficos de Crecimiento , Cabeza/diagnóstico por imagen , Humanos , Recién Nacido , Internacionalidad , Estudios Longitudinales , Masculino , Embarazo , Ultrasonografía Prenatal , Adulto JovenRESUMEN
PURPOSE: To analyze bioeffect safety indices and assess how often operators look at these indices during routine obstetric ultrasound. MATERIALS AND METHODS: Automated analysis of prospectively collected data including video recordings of full-length ultrasound scans coupled with operator eye tracking was performed. Using optical recognition, we extracted the Mechanical Index (MI), Thermal Index in soft tissue (TIs), and Thermal Index in bone (TIb) values and ultrasound mode. This allowed us to report the bioeffect safety indices during routine obstetric scans and assess adherence to professional organization recommendations. Eye-tracking analysis allowed us to assess how often operators look at the displayed bioeffect safety indices. RESULTS: A total of 637 ultrasound scans performed by 17 operators were included, of which 178, 216, and 243 scans were first, second, and third-trimester scans, respectively. During live scanning, the mean and range were 0.14 (0.1 to 3.0) for TIb, 0.2 (0.1 to 1.2) for TIs, and 0.9 (0.1 to 1.3) for MI. The mean and standard deviation of TIb were 0.15â±â0.03, 0.23â±â0.09, 0.32â±â0.24 in the first, second, and third trimester, respectively. For B-mode, the highest TIb was 0.8 in all trimesters. The highest TIb was recorded for pulsed-wave Doppler mode in all trimesters. The recommended exposure times were maintained in all scans. Analysis of eye tracking suggested that operators looked at bioeffect safety indices in only 27 (4.2â%) of the scans. CONCLUSION: In this study, recommended bioeffect indices were adhered to in all routine scans. However, eye tracking showed that operators rarely assessed safety indices during scanning.
Asunto(s)
Seguridad del Paciente , Ultrasonografía Prenatal , Femenino , Humanos , Embarazo , UltrasonografíaRESUMEN
Purpose To evaluate myocardial strain and circumferential transmural strain difference (cTSD; the difference between epicardial and endocardial circumferential strain) in a genotyped cohort with hypertrophic cardiomyopathy (HCM) and to explore correlations between cTSD and other anatomic and functional markers of disease status. Left ventricular (LV) dysfunction may indicate early disease in preclinical HCM (sarcomere mutation carriers without LV hypertrophy). Cardiac MRI feature tracking may be used to evaluate myocardial strain in carriers of HCM sarcomere mutation. Materials and Methods Participants with HCM and their family members participated in a prospective, multicenter, observational study (HCMNet). Genetic testing was performed in all participants. Study participants underwent cardiac MRI with temporal resolution at 40 msec or less. LV myocardial strain was analyzed by using feature-tracking software. Circumferential strain was measured at the epicardial and endocardial surfaces; their difference yielded the circumferential transmural strain difference (cTSD). Multivariable analysis to predict HCM status was performed by using multinomial logistic regression adjusting for age, sex, and LV parameters. Results Ninety-nine participants were evaluated (23 control participants, 34 participants with preclinical HCM [positive for sarcomere mutation and negative for LV hypertrophy], and 42 participants with overt HCM [positive for sarcomere mutation and negative for LV hypertrophy]). The average age was 25 years ± 11 and 44 participants (44%) were women. Maximal LV wall thickness was 9.5 mm ± 1.4, 9.8 mm ± 2.2, and 16.1 mm ± 5.3 in control participants, participants with preclinical HCM (P = .496 vs control participants), and participants with overt HCM (P < .001 vs control participants), respectively. cTSD for control participants, preclinical HCM, and overt HCM was 14% ± 4, 17% ± 4, and 22% ± 7, respectively (P < .01 for all comparisons). In multivariable models (controlling for septal thickness and log-transformed N-terminal brain-type natriuretic peptide), cTSD was predictive of preclinical and overt HCM disease status (P < .01). Conclusion Cardiac MRI feature tracking identifies myocardial dysfunction not only in participants with overt hypertrophic cardiomyopathy, but also in carriers of sarcomere mutation without left ventricular hypertrophy, suggesting that contractile abnormalities are present even when left ventricular wall thickness is normal. © RSNA, 2018 Online supplemental material is available for this article.
Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/genética , Imagen por Resonancia Cinemagnética , Mutación/genética , Sarcómeros/genética , Disfunción Ventricular Izquierda/genética , Adulto , Cardiomiopatía Hipertrófica/fisiopatología , Estudios Transversales , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Estudios Prospectivos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatologíaRESUMEN
BACKGROUND: Analysis of regional wall motion of the right ventricle (RV) is primarily qualitative with large interobserver variation in clinical practice. Thus, the purpose of this study was to use feature tracking to analyze regional wall motion abnormalities in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). METHODS: We enrolled 110 subjects (39 overt ARVC [mutation+/phenotype+] (35.5%), 40 preclinical ARVC [mutation+/phenotype-] (36.3%), and 31 control subjects (28.2%)). Cine steady state free precession cardiac MR was performed with temporal resolution ≤40 ms in the horizontal long axis (HLA), axial, and short axis directions. Regional strain was analyzed using feature tracking software and reproducibility was assessed by means of intraclass correlation coefficient. Dunnett's test was used in univariate analysis for comparisons to control subjects; cumulative odds logistic regression was used for minimally and fully adjusted multivariate models. RESULTS: Strain was significantly impaired in overt ARVC compared with control subjects both globally (P < 0.01) and regionally (all segments of HLA view, P < 0.01). In the HLA view, regional reproducibility was excellent within (intraclass correlation coefficient [ICC] = 0.81) and moderate between (ICC = 0.62) observers. Using a threshold of -31% subtricuspid strain in the HLA view, the sensitivity and specificity for overt ARVC were 75.0% and 78.2%, respectively. In multivariable analysis involving all three groups, subtricuspid strain less than -31% (beta = 1.38; P = 0.014) and RV end diastolic volume index (beta = 0.06; P = 0.001) were significant predictors of disease presence. CONCLUSION: RV strain can be reproducibly assessed with MR feature tracking, and regional strain is abnormal in overt ARVC compared with control subjects.
Asunto(s)
Displasia Ventricular Derecha Arritmogénica/diagnóstico por imagen , Ventrículos Cardíacos/patología , Imagen por Resonancia Cinemagnética , Adolescente , Adulto , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Análisis Multivariante , Mutación , Oportunidad Relativa , Fenotipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular DerechaAsunto(s)
Índice de Masa Corporal , Feto/diagnóstico por imagen , Obesidad Materna , Ultrasonografía Prenatal , Abdomen/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Femenino , Fémur/diagnóstico por imagen , Humanos , Labio/diagnóstico por imagen , Embarazo , Segundo Trimestre del Embarazo , Estudios Retrospectivos , Columna Vertebral/diagnóstico por imagenRESUMEN
Breast ultrasound (BUS) imaging has become a crucial modality, especially for providing a complementary view when other modalities (i.e., mammography) are not conclusive in the task of assessing lesions. The specificity in cancer detection using BUS imaging is low. These false-positive findings often lead to an increase of unnecessary biopsies. In addition, increasing sensitivity is also challenging given that the presence of artifacts in the B-mode ultrasound (US) images can interfere with lesion detection. To deal with these problems and improve diagnosis accuracy, ultrasound elastography was introduced. This paper validates a novel lesion segmentation framework that takes intensity (B-mode) and strain information into account using a Markov Random Field (MRF) and a Maximum a Posteriori (MAP) approach, by applying it to clinical data. A total of 33 images from two different hospitals are used, composed of 14 cancerous and 19 benign lesions. Results show that combining both the B-mode and strain data in a unique framework improves segmentation results for cancerous lesions (Dice Similarity Coefficient of 0.49 using B-mode, while including strain data reaches 0.70), which are difficult images where the lesions appear with blurred and not well-defined boundaries.
Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Estadísticos , Ultrasonografía Mamaria , Algoritmos , Femenino , HumanosRESUMEN
BACKGROUND: In 2006, WHO produced international growth standards for infants and children up to age 5 years on the basis of recommendations from a WHO expert committee. Using the same methods and conceptual approach, the Fetal Growth Longitudinal Study (FGLS), part of the INTERGROWTH-21(st) Project, aimed to develop international growth and size standards for fetuses. METHODS: The multicentre, population-based FGLS assessed fetal growth in geographically defined urban populations in eight countries, in which most of the health and nutritional needs of mothers were met and adequate antenatal care was provided. We used ultrasound to take fetal anthropometric measurements prospectively from 14 weeks and 0 days of gestation until birth in a cohort of women with adequate health and nutritional status who were at low risk of intrauterine growth restriction. All women had a reliable estimate of gestational age confirmed by ultrasound measurement of fetal crown-rump length in the first trimester. The five primary ultrasound measures of fetal growth--head circumference, biparietal diameter, occipitofrontal diameter, abdominal circumference, and femur length--were obtained every 5 weeks (within 1 week either side) from 14 weeks to 42 weeks of gestation. The best fitting curves for the five measures were selected using second-degree fractional polynomials and further modelled in a multilevel framework to account for the longitudinal design of the study. FINDINGS: We screened 13,108 women commencing antenatal care at less than 14 weeks and 0 days of gestation, of whom 4607 (35%) were eligible. 4321 (94%) eligible women had pregnancies without major complications and delivered live singletons without congenital malformations (the analysis population). We documented very low maternal and perinatal mortality and morbidity, confirming that the participants were at low risk of adverse outcomes. For each of the five fetal growth measures, the mean differences between the observed and smoothed centiles for the 3rd, 50th, and 97th centiles, respectively, were small: 2·25 mm (SD 3·0), 0·02 mm (3·0), and -2·69 mm (3·2) for head circumference; 0·83 mm (0·9), -0·05 mm (0·8), and -0·84 mm (1·0) for biparietal diameter; 0·63 mm (1·2), 0·04 mm (1·1), and -1·05 mm (1·3) for occipitofrontal diameter; 2·99 mm (3·1), 0·25 mm (3·2), and -4·22 mm (3·7) for abdominal circumference; and 0·62 mm (0·8), 0·03 mm (0·8), and -0·65 mm (0·8) for femur length. We calculated the 3rd, 5th 10th, 50th, 90th, 95th and 97th centile curves according to gestational age for these ultrasound measures, representing the international standards for fetal growth. INTERPRETATION: We recommend these international fetal growth standards for the clinical interpretation of routinely taken ultrasound measurements and for comparisons across populations. FUNDING: Bill & Melinda Gates Foundation.
Asunto(s)
Desarrollo Fetal/fisiología , Abdomen/embriología , Abdomen/fisiología , Adolescente , Adulto , Cefalometría/métodos , Femenino , Fémur/embriología , Humanos , Edad Materna , Embarazo , Estudios Prospectivos , Estándares de Referencia , Ultrasonografía Prenatal/normas , Salud Urbana , Adulto JovenRESUMEN
PURPOSE: To (a) demonstrate an image-processing method that can automatically measure the power Doppler signal in a three-dimensional ( 3D three-dimensional ) ultrasonographic (US) volume by using the location of organs within the image and (b) compare 3D three-dimensional fractional moving blood volume ( FMBV fractional moving blood volume ) results with commonly used, unstandardized measures of 3D three-dimensional power Doppler by using the human placenta as the organ of interest. MATERIALS AND METHODS: This is a retrospective study of scans obtained as part of a prospective study of imaging placental biomarkers with US, performed with ethical approval and written informed consent. One hundred forty-three consecutive female patients were examined by using an image-processing technique. Three-dimensional FMBV fractional moving blood volume was measured on the vasculature from the uteroplacental interface to a depth 5 mm into the placenta by using a normalization volume 10 mm outside the uteroplacental interface and compared against the Virtual Organ Computer-aided AnaLysis ( VOCAL Virtual Organ Computer-aided AnaLysis ; GE Healthcare, Milwaukee, Wis) vascularization flow index ( VFI vascularization flow index ). Intra- and interobserver variability was assessed in a subset of 18 volumes. Wilcoxon signed rank test and intraclass correlation coefficients were used to assess measurement repeatability. RESULTS: The mean 3D three-dimensional FMBV fractional moving blood volume value ± standard deviation was 11.78% ± 9.30 (range, 0.012%-44.16%). Mean VFI vascularization flow index was 2.26 ± 0.96 (range, 0.15-6.06). Linear regression of VFI vascularization flow index versus FMBV fractional moving blood volume produced an R(2) value of 0.211 and was significantly different in distribution (P < .001). Intraclass correlation coefficient analysis showed higher FMBV fractional moving blood volume values than VFI vascularization flow index for intra- and interobserver variability; intraobserver values were 0.95 for FMBV fractional moving blood volume (95% confidence interval [ CI confidence interval ]: 0.90, 0.98) versus 0.899 for VFI vascularization flow index (95% CI confidence interval : 0.78, 0.96), and interobserver values were 0.93 for FMBV fractional moving blood volume (95% CI confidence interval : 0.82, 0.97) versus 0.67 for VFI vascularization flow index (95% CI confidence interval : 0.32, 0.86). CONCLUSION: The extension of an existing two-dimensional standardized power Doppler measurement into 3D three-dimensional by using an image-processing technique was shown in an in utero placental study. Three-dimensional FMBV fractional moving blood volume and VFI vascularization flow index produced significantly different results. FMBV fractional moving blood volume performed better than VFI vascularization flow index in repeatability studies. Further studies are needed to assess accuracy against a reference standard.
Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Placenta/irrigación sanguínea , Placenta/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Adolescente , Adulto , Volumen Sanguíneo , Femenino , Humanos , Embarazo , Estudios Prospectivos , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: To investigate the use of cine multidetector computed tomography (CT) to detect changes in myocardial function in a swine cardiomyopathy model. MATERIALS AND METHODS: All animal protocols were in accordance with the Principles for the Utilization and Care of Vertebrate Animals Used in Testing Research and Training and approved by the University of Missouri Animal Care and Use Committee. Strain analysis of cine multidetector CT images of the left ventricle was optimized and analyzed with feature-tracking software. The standard of reference for strain was harmonic phase analysis of tagged cardiac magnetic resonance (MR) images at 3.0 T. An animal model of cardiomyopathy was imaged with both cardiac MR and 320-section multidetector CT at a temporal resolution of less than 50 msec. Three groups were evaluated: control group (n = 5), aortic-banded myocardial hypertrophy group (n = 5), and aortic-banded and cyclosporine A- treated cardiomyopathy group (n = 5). Histologic samples of the myocardium were obtained for comparison with strain results. Dunnett test was used for comparisons of the concentric remodeling group and eccentric remodeling group against the control group. RESULTS: Collagen volume fraction ranged from 10.9% to 14.2%; lower collagen fraction values were seen in the control group than in the cardiomyopathy groups (P < .05). Ejection fraction and conventional metrics showed no significant differences between control and cardiomyopathy groups. Radial strain for both cardiac MR and multidetector CT was abnormal in both concentric (cardiac MR 25.1% ± 4.2; multidetector CT 28.4% ± 2.8) and eccentric (cardiac MR 23.2% ± 2.0; multidetector CT 24.4% ± 2.1) remodeling groups relative to control group (cardiac MR 18.9% ± 1.9, multidetector CT 22.0% ± 1.7, P < .05, all comparisons). Strain values for multidetector CT versus cardiac MR showed better agreement in the radial direction than in the circumferential direction (r = 0.55, P = .03 vs r = 0.40, P = .13, respectively). CONCLUSION: Multidetector CT strain analysis has potential to identify regional wall-motion abnormalities in cardiomyopathy that is not otherwise detected using conventional metrics of myocardial function.
Asunto(s)
Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Imagen por Resonancia Magnética , Tomografía Computarizada Multidetector , Miocardio/patología , Animales , Fenómenos Biomecánicos , Técnicas de Imagen Cardíaca , Modelos Animales de Enfermedad , Fibrosis , Masculino , Porcinos , Porcinos EnanosRESUMEN
A comprehensive set of fully integrated anthropometric measures is needed to evaluate human growth from conception to infancy so that consistent judgments can be made about the appropriateness of fetal and infant growth. At present, there are 2 barriers to this strategy. First, descriptive reference charts, which are derived from local, unselected samples with inadequate methods and poor characterization of their putatively healthy populations, commonly are used rather than prescriptive standards. The use of prescriptive standards is justified by the extensive biologic, genetic, and epidemiologic evidence that skeletal growth is similar from conception to childhood across geographic populations, when health, nutrition, environmental, and health care needs are met. Second, clinicians currently screen fetuses, newborn infants, and infants at all levels of care with a wide range of charts and cutoff points, often with limited appreciation of the underlying population or quality of the study that generated the charts. Adding to the confusion, infants are evaluated after birth with a single prescriptive tool: the World Health Organization Child Growth Standards, which were derived from healthy, breastfed newborn infants, infants, and young children from populations that have been exposed to few growth-restricting factors. The International Fetal and Newborn Growth Consortium for the 21st Century Project addressed these issues by providing international standards for gestational age estimation, first-trimester fetal size, fetal growth, newborn size for gestational age, and postnatal growth of preterm infants, all of which complement the World Health Organization Child Growth Standards conceptually, methodologically, and analytically. Hence, growth and development can now, for the first time, be monitored globally across the vital first 1000 days and all the way to 5 years of age. It is clear that an integrative approach to monitoring growth and development from pregnancy to school age is desirable, scientifically supported, and likely to improve care, referral patterns, and reporting systems. Such integration can be achieved only through the use of international growth standards, especially in increasingly diverse, mixed ancestry populations. Resistance to new scientific developments has been hugely problematic in medicine; however, we are confident that the obstetric and neonatal communities will join their pediatric colleagues worldwide in the adoption of this integrative strategy.
Asunto(s)
Antropometría/métodos , Desarrollo Infantil , Desarrollo Fetal , Edad Gestacional , Desarrollo Óseo , Niño , Preescolar , Continuidad de la Atención al Paciente , Femenino , Gráficos de Crecimiento , Humanos , Lactante , Recién Nacido , Masculino , Embarazo , Valores de ReferenciaRESUMEN
BACKGROUND: Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). METHODS: Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. RESULTS: Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P < 0.0005) and segmental image quality (2.42 ± 0.99 vs. 1.93 ± 1.18, P < 0.005) compared to unfused 3D acquisitions. Levels achieved were closer to scores for 2D contrast images (CNR: 9.04 ± 2.21, P = 0.6; segmental image quality: 2.91 ± 0.37, P < 0.005). WMSI calculated from fused 3D volumes did not differ significantly from those obtained from 2D contrast echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). CONCLUSION: 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography.
Asunto(s)
Medios de Contraste , Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano , Ecocardiografía/métodos , Femenino , Humanos , Aumento de la Imagen , Masculino , Variaciones Dependientes del Observador , Fosfolípidos , Reproducibilidad de los Resultados , Hexafluoruro de AzufreRESUMEN
Auditory and visual signals are two primary perception modalities that are usually present together and correlate with each other, not only in natural environments but also in clinical settings. However, audio-visual modelling in the latter case can be more challenging, due to the different sources of audio/video signals and the noise (both signal-level and semantic-level) in auditory signals-usually speech audio. In this study, we consider audio-visual modelling in a clinical setting, providing a solution to learn medical representations that benefit various clinical tasks, without relying on dense supervisory annotations from human experts for the model training. A simple yet effective multi-modal self-supervised learning framework is presented for this purpose. The proposed approach is able to help find standard anatomical planes, predict the focusing position of sonographer's eyes, and localise anatomical regions of interest during ultrasound imaging. Experimental analysis on a large-scale clinical multi-modal ultrasound video dataset show that the proposed novel representation learning method provides good transferable anatomical representations that boost the performance of automated downstream clinical tasks, even outperforming fully-supervised solutions. Being able to learn such medical representations in a self-supervised manner will contribute to several aspects including a better understanding of obstetric imaging, training new sonographers, more effective assistive tools for human experts, and enhancement of the clinical workflow.
Asunto(s)
Ultrasonografía , Humanos , Ultrasonografía/métodos , Femenino , Percepción Visual/fisiología , Grabación en VideoRESUMEN
BACKGROUND: Abdominal ultrasound imaging is an important method for hepatic schistosomiasis diagnosis and staging. Several ultrasound staging systems have been proposed, each attempting to standardise schistosomal periportal fibrosis (PPF) diagnosis. This review aims to establish the role of ultrasound in the diagnosis and staging of schistosomal PPF, and to map the evolution of ultrasound staging systems over time, focusing on internal validation and external reproducibility. METHODS: A systematic search was undertaken on 21st December 2022 considering the following databases: PubMed/MEDLINE (1946-present), Embase (1974-present), Global Health (1973-present), Global Index Medicus (1901-present), and Web of Science Core Collection-Science Citation Index Expanded (1900-present) and the Cochrane Central Register of Controlled Trials (1996-present). Case reports, systematic reviews and meta-analyses, and studies exclusively using transient or shear-wave elastography were excluded. Variables extracted included study design, study population, schistosomal PPF characteristics, and diagnostic methods. The PRISMA-ScR (2018) guidelines were followed to inform the structure of the scoping analysis. RESULTS: The initial search yielded 573 unique articles, of which 168 were removed after screening titles and abstracts, 43 were not retrieved due to full texts not being available online or through inter-library loans, and 170 were excluded during full text review. There were 192 remaining studies eligible for extraction. Of the extracted studies, 61.8% (76/123) of studies that reported study year were conducted after the year 2000. Over half of all extracted studies (59.4%; 114/192) were conducted in Brazil (26.0%; 50/192), China (18.8%; 36/192) or Egypt (14.6%; 28/192). For the species of schistosome considered, 77.6% (149/192) of studies considered S. mansoni and 21.4% (41/192) of studies considered S. japonicum. The ultrasound staging systems used took on three forms: measurement-based, feature-based and image pattern-based. The Niamey protocol, a measurement and image pattern-based system, was the most used among the staging systems (32.8%; 63/192), despite being the most recently proposed in 1996. The second most used was the Cairo protocol (20.8%; 40/192). Of the studies using the Niamey protocol, 77.8% (49/63) only used the image patterns element. Where ultrasound technology was specified, studies after 2000 were more likely to use convex transducers (43.4%; 33/76) than studies conducted before 2000 (32.7%; 16/49). Reporting on ultrasound-based hepatic diagnoses and their association with clinical severity was poor. Just over half of studies (56.2%; 108/192) reported the personnel acquiring the ultrasound images. A small number (9.4%; 18/192) of studies detailed their methods of image quality assurance, and 13.0% (25/192) referenced, discussed or quantified the inter- or intra-observer variation of the staging system that was used. CONCLUSIONS: The exclusive use of the image patterns in many studies despite lack of specific acquisition guidance, the increasing number of studies over time that conduct ultrasound staging of schistosomal PPF, and the advances in ultrasound technology used since 2000 all indicate a need to consider an update to the Niamey protocol. The protocol update should simplify and prioritise what is to be assessed, advise on who is to conduct the ultrasound examination, and procedures for improved standardisation and external reproducibility.
Asunto(s)
Cirrosis Hepática , Sistemas de Atención de Punto , Esquistosomiasis , Ultrasonografía , Humanos , Cirrosis Hepática/diagnóstico por imagen , Ultrasonografía/métodos , Esquistosomiasis/diagnóstico por imagen , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/parasitología , Reproducibilidad de los ResultadosRESUMEN
OBJECTIVE: Automated medical image analysis solutions should closely mimic complete human actions to be useful in clinical practice. However, more often an automated image analysis solution represents only part of a human task, which restricts its practical utility. In the case of ultrasound-based fetal biometry, an automated solution should ideally recognize key fetal structures in freehand video guidance, select a standard plane from a video stream and perform biometry. A complete automated solution should automate all three subactions. METHODS: In this article, we consider how to automate the complete human action of first-trimester biometry measurement from real-world freehand ultrasound. In the proposed hybrid convolutional neural network (CNN) architecture design, a classification regression-based guidance model detects and tracks fetal anatomical structures (using visual cues) in the ultrasound video. Several high-quality standard planes that contain the mid-sagittal view of the fetus are sampled at multiple time stamps (using a custom-designed confident-frame detector) based on the estimated probability values associated with predicted anatomical structures that define the biometry plane. Automated semantic segmentation is performed on the selected frames to extract fetal anatomical landmarks. A crown-rump length (CRL) estimate is calculated as the mean CRL from these multiple frames. RESULTS: Our fully automated method has a high correlation with clinical expert CRL measurement (Pearson's p = 0.92, R-squared [R2] = 0.84) and a low mean absolute error of 0.834 (weeks) for fetal age estimation on a test data set of 42 videos. CONCLUSION: A novel algorithm for standard plane detection employs a quality detection mechanism defined by clinical standards, ensuring precise biometric measurements.