Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Infect Dis ; 18(1): 570, 2018 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-30428850

RESUMEN

BACKGROUND: Viral load (VL) testing is being scaled up in resource-limited settings. However, not all commercially available VL testing methods have been evaluated under field conditions. This study is one of a few to evaluate the Biocentric platform for VL quantification in routine practice in Sub-Saharan Africa. METHODS: Venous blood specimens were obtained from patients eligible for VL testing at two health facilities in Swaziland from October 2016 to March 2017. Samples were centrifuged at two laboratories (LAB-1, LAB-2) to obtain paired plasma specimens for VL quantification with the national reference method and on the Biocentric platform. Agreement (correlation, Bland-Altman) and accuracy (sensitivity, specificity) indicators were calculated at the VL thresholds of 416 (2.62 log10) and 1000 (3.0 log10) copies/mL. Leftover samples from patients with discordant VL results were re-quantified and accuracy indicators recalculated. Logistic regression was used to compare laboratory performance. RESULTS: A total of 364 paired plasma samples (LAB-1: n = 198; LAB-2: n = 166) were successfully tested using both methods. The correlation was high (R = 0.82, p < 0.01), and the Bland-Altman analysis showed a minimal mean difference (- 0.03 log10 copies/mL; 95% CI: -1.15 to 1.08). At the clinical threshold level of 3.0 log10 copies/mL, the sensitivity was 88.6% (95% CI: 78.7 to 94.9) and the specificity was 98.3% (95% CI: 96.1 to 99.4). Sensitivity was higher in LAB-1 (100%; 95% CI: 71.5 to 100) than in LAB-2 (86.4%; 95% CI: 75.0 to 94.0). Most upward (n = 8, 2.2%) and downward (n = 11, 3.0%) misclassifications occurred at the 2.62 log threshold, with LAB-2 having a 16 (95% CI: 2.26 to 113.27; p = 0.006) times higher odds of downward misclassification. After retesting of discordant leftover samples (n = 17), overall sensitivity increased to 93.5% (95% CI: 85.5 to 97.9) and 97.1% (95% CI: 90.1 to 99.7) at the 2.62 and 3.0 thresholds, and specificity increased to 98.6% (95% CI: 96.5 to 99.6) and 99.0% (95% CI: 97.0 to 99.8) respectively. CONCLUSIONS: The test characteristics of the Biocentric platform were overall comparable to the national reference method for VL quantification. One laboratory tended to misclassify VL results downwards, likely owing to unmet training needs and lack of previous hands-on practice.


Asunto(s)
Infecciones por VIH/diagnóstico , VIH-1/genética , ARN Viral/sangre , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/métodos , Adolescente , Adulto , Pruebas Diagnósticas de Rutina/economía , Pruebas Diagnósticas de Rutina/métodos , Pruebas Diagnósticas de Rutina/normas , Esuatini , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Sistemas de Atención de Punto/economía , Sistemas de Atención de Punto/normas , Valor Predictivo de las Pruebas , ARN Viral/análisis , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas Serológicas , Manejo de Especímenes/métodos , Carga Viral/genética , Adulto Joven
2.
J Acquir Immune Defic Syndr ; 88(5): 506-517, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34483294

RESUMEN

BACKGROUND: The lack of acute and early HIV infection (AEHI) diagnosis and care contributes to high HIV incidence in resource-limited settings. We aimed to assess the yield of AEHI, predict and diagnose AEHI, and describe AEHI care outcomes in a public sector setting in Eswatini. SETTING: This study was conducted in Nhlangano outpatient department from March 2019 to March 2020. METHODS: Adults at risk of AEHI underwent diagnostic testing for AEHI with the quantitative Xpert HIV-1 viral load (VL) assay. AEHI was defined as the detection of HIV-1 VL on Xpert and either an HIV-seronegative or HIV-serodiscordant third-generation antibody-based rapid diagnostic test (RDT) result. First, the cross-sectional analysis obtained the yield of AEHI and established a predictor risk score for the prediction of AEHI using Lasso logistic regression. Second, diagnostic accuracy statistics described the ability of the fourth-generation antibody/p24 antigen-based Alere HIV-Combo RDT to diagnose AEHI (vs Xpert VL testing). Third, we described acute HIV infection care outcomes of AEHI-positive patients using survival analysis. RESULTS: Of 795 HIV-seronegative/HIV-serodiscordant outpatients recruited, 30 (3.8%, 95% confidence interval: 2.6% to 5.3%) had AEHI. The predictor risk score contained several factors (HIV-serodiscordant RDT, women, feeling at risk of HIV, swollen glands, and fatigue) and had sensitivity and specificity of 83.3% and 65.8%, respectively, to predict AEHI. The HIV-Combo RDT had sensitivity and specificity of 86.2% and 99.9%, respectively, to diagnose AEHI. Of 30 AEHI-positive patients, the 1-month cumulative treatment initiation was 74% (95% confidence interval: 57% to 88%), and the 3-month viral suppression (<1000 copies/mL) was 87% (67% to 98%). CONCLUSION: AEHI diagnosis and care seem possible in resource-limited settings.


Asunto(s)
Antirretrovirales/uso terapéutico , Anticuerpos Anti-VIH/sangre , Infecciones por VIH , VIH-1/inmunología , Enfermedad Aguda , Adulto , Estudios Transversales , Diagnóstico Precoz , Esuatini/epidemiología , Femenino , Proteína p24 del Núcleo del VIH , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , Humanos , Valor Predictivo de las Pruebas , Sector Público , Sensibilidad y Especificidad , Factores de Tiempo
3.
J Acquir Immune Defic Syndr ; 82(1): 96-104, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31408452

RESUMEN

BACKGROUND: To assess the performance and suitability of dried blood spot (DBS) sampling using filter paper to collect blood for viral load (VL) quantification under routine conditions. METHODS: We compared performance of DBS VL quantification using the Biocentric method with plasma VL quantification using Roche and Biocentric as reference methods. Adults (≥18 years) were enrolled at 2 health facilities in Eswatini from October 12, 2016 to March 1, 2017. DBS samples were prepared through finger-prick by a phlebotomist (DBS-1), and through the pipetting of whole venous blood by a phlebotomist (DBS-2) and by a laboratory technologist (DBS-3). We calculated the VL-testing completion rate, correlation, and agreement, as well as diagnostic accuracy estimates at the clinical threshold of 1000 copies/mL. RESULTS: Of 362 patients enrolled, 1066 DBS cards (DBS-1: 347; DBS-2: 359; DBS-3: 360) were tested. Overall, test characteristics were comparable between DBS-sampling methods, irrespective of the reference method. The Pearson correlation coefficients ranged from 0.67 to 0.82 (P < 0.001) for different types of DBS sampling using both reference methods, and the Bland-Altman difference ranged from 0.15 to 0.30 log10 copies/mL. Sensitivity estimates were from 85.3% to 89.2% and specificity estimates were from 94.5% to 98.6%. The positive predictive values were between 87.0% and 96.5% at a prevalence of 30% VL elevations, and negative predictive values were between 93.7% and 95.4%. CONCLUSIONS: DBS VL quantification using the newly configured Biocentric method can be part of contextualized VL-testing strategies, particularly for remote settings and populations with higher viral failure rates.


Asunto(s)
Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Plasma/virología , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/métodos , Adulto , Recolección de Muestras de Sangre , Pruebas con Sangre Seca/métodos , Esuatini , Femenino , VIH-1/genética , Humanos , Masculino , ARN Viral/sangre , Sensibilidad y Especificidad , Pruebas Serológicas
4.
J Int AIDS Soc ; 20(Suppl 6): 21756, 2017 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-28872273

RESUMEN

INTRODUCTION: Rapid diagnostic testing has made HIV diagnosis and subsequent treatment more accessible. However, multiple factors, including improper implementation of testing strategies and clerical errors, have been reported to lead to HIV misdiagnosis. The World Health Organization has recommended HIV retesting prior to antiretroviral therapy (ART) initiation which has become pertinent with scaling up of Early Access to ART for All (EAAA). In this analysis, misdiagnosed clients are identified from a subgroup of clients enrolled in EAAA implementation study in Swaziland. METHODS: The subgroup to assess misdiagnosis was identified from enrolled EAAA study clients, who had an undetectable viral load prior to ART initiation between September 1, 2014 and May 31, 2016. One hundred and five of 2533 (4%) clients had an undetectable viral load prior to initiation to ART (pre-ART). The HIV status of clients was confirmed using the Determine HIV 1/2 and Uni-Gold HIV 1/2 rapid tests performed serially as recommended by the national testing algorithm. The status of clients on ART was additionally confirmed by fourth-generation HIV Ag/Ab combo tests, Architect and Genscreen Ultra. RESULTS: Fourteen of the 105 (13%) clients were false positive (HIV negative) on confirmation testing, of whom five (36%) were still in pre-ART care, while nine (64%) were in ART care. Overall, proportion of false positive was 0.6% (14/2533). The false-positive clients had a median CD4 of 791 cells/ml (interquartile range (IQR): 628, 967) compared to 549 cells/ml (IQR: 387, 791) for true positives (HIV positive) (p = 0.0081) and were nearly 20 years older (p = 0.0008). CONCLUSIONS: Overall 0.6% of all enrolled EAAA clients were misdiagnosed, and 64% of misdiagnosed clients were initiated on ART. With adoption of EAAA guidelines by national governments, ART initiation regardless of immunological criteria, strengthening of proficiency testing and adoption of retesting prior to ART initiation would allow identification of misdiagnosed clients and further reduce potential of initiating misdiagnosed clients on ART.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Errores Diagnósticos/estadística & datos numéricos , Infecciones por VIH/diagnóstico , Adulto , Anticuerpos Antivirales/sangre , Recuento de Linfocito CD4 , Esuatini , Femenino , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/genética , VIH-1/inmunología , VIH-1/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Carga Viral , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA