RESUMEN
The complexity of structural heart interventions has led to a demand for sophisticated periprocedural imaging guidance. Although traditional 2-dimensional (2D) transesophageal techniques are used widely, new-generation 3D ultrasound probes enable high temporal and spatial resolution. Multiplanar reconstruction of acquired 3D datasets has gained considerable momentum for precise imaging and to increase the validity of measurements. Previously, this technique was used after the acquisition of suitable 3D datasets. Recent advances in technology have enabled the use of live mode for multiplanar reconstruction across different ultrasound vendor platforms. The use of live multiplanar reconstruction can enhance the precision in real-time imaging, enable simultaneous visualization of structures of interest in multiple planes, reduce the need for probe manipulation, and thereby contribute to the success of the procedures. In this narrative review, the authors describe the rationale and utility for 3D transesophageal live multiplanar reconstruction, and outline its use for the structural heart interventions of mitral and tricuspid valve edge-to-edge repair, left atrial appendage occlusion, and the Lampoon procedure. A 3D transesophageal echocardiogram with live-multiplanar reconstruction has the potential to advance guidance of these complex interventions.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional , Humanos , Ecocardiografía Transesofágica/métodos , Válvula Tricúspide , Ecocardiografía Tridimensional/métodosRESUMEN
BACKGROUND: A lower rate of permanent pacemaker (PPM) has been linked to a target aortic implantation height (AIH) >0.70, following transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve. Based on clinical experience, it was hypothesized that a higher AIH (≥0.85) would lower the rate of PPM implantation. METHODS: A total of 127 patients (66 females, 61 males; mean age 82 ± 8 years) underwent TAVR with the SAPIEN 3 valve between May 2015 and July 2016. AIH was defined as the proportion of the valve frame above the aortic annulus in the post-deployment aortogram. A target AIH (≥0.70) was achieved in 113 patients (89%). Cases were stratified into a High Implantation (HI) group (AIH ≥0.85; 33 patients) or a Standard Implantation (SI) group (AIH <0.85; 94 patients). RESULTS: The mean Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of all patients was 6.4 ± 3.5%. Preoperative right bundle branch block (RBBB) was prevalent in 13% of SI patients, and in 18% of HI patients (p = 0.56). There were no significant differences in operative mortality (3.2% versus 0%), median length of stay (2 days versus 3 days) and incidence of moderate-to-severe paravalvular leak (3.2% versus 0%; all p >0.410) between SI and HI patients, respectively. Likewise, the incidence of new PPM did not differ between the two groups (12% in HI versus 13% in SI; p ≥0.99). The mean AIH was similar for patients with PPM implantation (0.80 ± 0.08) compared to those without (0.78 ± 0.06; p = 0.520). Preoperative RBBB was significantly associated with PPM implantation (odds ratio (OR) 10.1; p = 0.002), and patients who underwent PPM implantation had a higher operative mortality (12.5% versus 1%; p = 0.040). CONCLUSIONS: Among TAVR patients who received the SAPIEN 3 heart valve, a higher AIH (≥0.85) was not associated with a lower rate of PPM implantation or increased operative mortality. Prior RBBB was the only independent risk factor for new PPM implantation. Long-term follow up is crucial in determining the clinical significance of PPM implantation.
Asunto(s)
Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Aortografía , Bloqueo de Rama/complicaciones , Estimulación Cardíaca Artificial , Femenino , Humanos , MasculinoRESUMEN
BACKGROUND: Epicardial access (EA) has emerged as an increasingly important approach for the treatment of ventricular arrhythmias and to perform other interventional cardiology procedures. EA is frequently underutilized because the current approach is challenging and carries a high risk of life-threatening complications. OBJECTIVE: The purpose of this study was to determine the efficacy and safety of the SAFER (Sustained Apnea for Epicardial Access With Right Ventriculography) epicardial approach. METHODS: Consecutive patients who underwent EA with the SAFER technique were included in this multicenter study. The primary efficacy outcome was the successful achievement of EA. The primary safety outcomes included right ventricular (RV) perforation, major hemorrhagic pericardial effusion (HPE), and bleeding requiring surgical intervention. Secondary outcomes included procedural characteristics and any complications. Our results were compared with those from previous studies describing other EA techniques to assess differences in outcomes. RESULTS: A total of 105 patients undergoing EA with the SAFER approach from June 2021 to February 2023 were included. EA was used for ventricular tachycardia ablation in 98 patients (93.4%), left atrial appendage closure in 6 patients (5.7%), and phrenic nerve displacement in 1 patient (0.9%). EA was successful in all subjects (100%). The median time to EA was 7 minutes (IQR: 5-14 minutes). No cases of RV perforation, HPE, or need of surgical intervention were observed in this cohort. Comparing our results with previous studies about EA, the SAFER epicardial approach resulted in a significant reduction in major pericardial bleeding. CONCLUSIONS: The SAFER epicardial approach is a simple, efficient, effective, and low-cost technique easily reproducible across multiple centers. It is associated with lower complication rates than previously reported techniques for EA.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Lesiones Cardíacas , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Apnea , Arritmias Cardíacas , Pericardio/diagnóstico por imagen , Pericardio/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , HemorragiaRESUMEN
BACKGROUND: Coagulopathy and massive bleeding are severe complications of cardiac surgery, particularly in procedures requiring prolonged cardiopulmonary bypass (CPB). There is huge variability in transfusion practices across hospitals and providers in cross-sectional studies. This variability may indicate unguided decision-making, perhaps attributable to lack of reliable, predictive laboratory testing of coagulopathy to guide transfusion practice. Rotational thromboelastometry (ROTEM) measures multiple coagulation parameters and may provide value from its ease of use, rapid results, and measurement of several steps in the coagulation pathway. Yet, the predictive value and utility of ROTEM remains unclear. In this study, we investigated ROTEM's predictive value for chest tube drainage after cardiac surgery. METHODS: Three hundred twenty-one patients undergoing cardiac surgery involving CPB were enrolled. Patient data were obtained from medical records, including chest tube output (CTO) from post-CPB through the first 8 postoperative hours. Perioperative and postoperative blood samples were collected for ROTEM analysis. Three measures of CTO were used as the primary end points for assessing coagulopathy: (i) continuous CTO; (ii) CTO dichotomized at 600 mL (75th percentile); and (iii) CTO dichotomized at 910 mL (90th percentile). Clinical and hematological variables, excluding ROTEM data, that were significantly correlated (P < 0.05) with continuous CTO were included in a stepwise regression model (model 1). An additional model that contained ROTEM variables in addition to the variables from model 1 was created (model 2). Significance in subsequent analyses was declared at P < 0.0167 to account for the 3 CTO end points. Net reclassification index was used to assess overall value of ROTEM data. RESULTS: For continuous CTO, ROTEM variables improved the model's predictive ability (P < 0.0001). For CTO dichotomized at 600 mL (75th percentile), ROTEM did not improve the area under the receiver operating characteristic curve (AUC) (P = 0.03). Similarly, for CTO dichotomized at 910 mL (90th percentile), ROTEM did not improve the AUC (P = 0.23). Net reclassification index similarly indicated that ROTEM results did not improve overall classification of patients (P = 0.12 for CTO ≥600 mL; P = 0.08 for CTO ≥910 mL). CONCLUSIONS: These results suggest that ROTEM data do not substantially improve a model's ability to predict chest tube drainage, beyond frequently used clinical and laboratory parameters. Although several ROTEM parameters were individually associated with CTO, they did not significantly improve goodness of fit when added to statistical models comprising only clinical and routine laboratory parameters. ROTEM does not seem to improve prediction of chest tube drainage after cardiac surgery involving CPB, although its use in guiding transfusion during cardiac surgery remains to be determined.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hemorragia Posoperatoria/diagnóstico , Tromboelastografía/métodos , Anciano , Puente Cardiopulmonar , Tubos Torácicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROCRESUMEN
Intraoperative transesophageal echocardiography is a standard diagnostic and monitoring tool employed in the management of patients undergoing an entire spectrum of cardiac surgical procedures, ranging from "routine" surgical coronary revascularization to complex valve repair, combined procedures, and organ transplantation. Utilizing a protocol as a starting point for imaging in all procedures and all patients enables standardization of image acquisition, reduction in variability in quality of imaging and reporting, and ultimately better patient care. Clear communication of the echocardiographic findings to the surgical team, as well as understanding the impact of new findings on the surgical plan, are paramount. Equally important is the need for complete understanding of the technical steps of the surgical procedures being performed and the complications that may occur, in order to direct the postprocedure evaluation toward aspects directly related to the surgical procedure and to provide pertinent echocardiographic information. The rationale for this document is to outline a systematic approach describing how to apply the existing guidelines to questions on cardiac structure and function specific to the intraoperative environment in open, minimally invasive, or hybrid cardiac surgery procedures.
Asunto(s)
Ecocardiografía Transesofágica , Cirujanos , Anestesiólogos , Ecocardiografía , Humanos , Quirófanos , Estados UnidosRESUMEN
The advent of percutaneous therapies has significantly altered therapeutic options for patients with valvular heart disease. Building on the success of transcatheter aortic valve replacement, both expanded indications and purpose-built devices are now being used to address percutaneous approaches for mitral valve pathology. While surgical mitral valve repair remains the gold standard for addressing significant mitral valve pathology, there has been a progressive increase in the utilization of bioprosthetic valves despite their limited lifespan. The risks of reoperation to address mitral valve repair failure or bioprosthetic valve dysfunction is not insignificant. In light of the aging population and the potential for significant associated comorbidities, less invasive alternative techniques hold particular appeal. Utilization of commercially available transcatheter aortic valve replacement valves for failed surgical valves has been shown to have better short-term mortality than would be predicted for open reoperation. As a result, the US Food and Drug Administration approved the utilization of transcatheter mitral valve-in-valve replacement for the failed bioprosthetic valve in high surgical risk patients. Despite the favorable outcomes, transcatheter mitral valve-in-valve is not without procedural challenges and potential complications including malpositioning, embolization, paravalvular leak, and outflow tract obstruction. Awareness of these challenges, mitigation strategies, and therapeutic options is imperative to optimizing outcomes in this high-risk patient population.
Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/patología , Válvula Mitral/cirugía , Humanos , Reoperación , Insuficiencia del TratamientoAsunto(s)
Ablación por Catéter , Taquicardia Ventricular , Cirugía Torácica Asistida por Video , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Cirugía Torácica Asistida por Video/métodos , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Pericardio/cirugía , Persona de Mediana Edad , FemeninoRESUMEN
Sex-based differences in outcomes have been shown to affect caregiving in medical disciplines. Increased spending due to postacute care transfer policies has led hospitals to further scrutinize patient outcomes and disposition patterns after inpatient admissions. We examined sex-based differences in rehabilitative service utilization after transcatheter aortic valve implantation (TAVI). We queried all TAVI discharges in the National Inpatient Sample database from 2012 to 2014 (nâ¯=â¯40,900). Thirteen thousand eight hundred fifteen patients were discharged to home and 12,175 patients were discharged to rehabilitation facility; those not discharged routinely or to a rehabilitation facility were excluded. Patients with nonhome discharges were older (83.3 vs 79.0 years) and female (58.3% vs 37.7%) with a greater number of chronic conditions (9.91 vs 9.03) and number of Elixhauser co-morbidities (6.5 vs 5.8, all p < 0.05). Nonhome discharge patients also had a significantly longer length of stay (LOS) (11.3 days vs 5.3 days) and higher hospitalization costs ($66,246 vs $48,710, all p < 0.001) compared to home-discharged patients. Overall in-hospital mortality for female patients who underwent TAVI was higher compared to males (4.6% vs 3.6%, p < 0.05). On multivariable logistic regression, female sex was an independent predictor for disposition to rehabilitation facilities after TAVI (odds ratio 2.17; 95% confidence interval: 1.88 to 2.50; p < 0.001). Other independent predictors for females discharged to rehabilitation included the presence of rheumatoid arthritis and collagen vascular disease, body mass index greater than 30 kg/m2, depression, and sum of Elixhauser co-morbidities (all p < 0.001). In conclusion, nonhome discharge TAVI patients added LOS and hospital costs compared to home discharge TAVI patients, and female sex was one of the major predictors despite the lower co-morbidities.
Asunto(s)
Estenosis de la Válvula Aórtica/rehabilitación , Estenosis de la Válvula Aórtica/cirugía , Servicios de Atención de Salud a Domicilio , Hospitalización , Alta del Paciente , Centros de Rehabilitación , Reemplazo de la Válvula Aórtica Transcatéter/rehabilitación , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Factores Sexuales , Resultado del Tratamiento , Estados UnidosRESUMEN
Percutaneous intervention for mitral valve (MV) disease has been established as an alternative to open surgical MV repair in patients with prohibitive surgical risk. Multiple percutaneous approaches have been described and are in various stages of development. Edge-to-edge leaflet plication with the MitraClip (Abbott, Menlo Park, CA) is currently the only Food and Drug Administration-approved device specifically for primary or degenerative lesions. Use of the edge-to-edge clip for secondary mitral regurgitation is currently under investigation and may result in expanded indications. Echocardiography has significantly increased our understanding of the anatomy of the MV and provided us with the ability to classify and quantify the associated mitral regurgitation. For percutaneous interventions of the MV, transesophageal echocardiography imaging is used for patient screening, intraprocedural guidance, and confirmation of the result. Optimal outcomes require the echocardiographer and the proceduralist to have a thorough understanding of intra-atrial septal and MV anatomy, as well as an appreciation for the key points and potential pitfalls of each of the procedural steps. With increasing experience, more complex valvular pathology can be successfully percutaneously treated. In addition to two-dimensional echocardiography, advances in three-dimensional echocardiography and fusion imaging will continue to support the refinement of current technologies, the expansion of clinical applications, and the development of novel devices.
Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Diseño de PrótesisRESUMEN
OBJECTIVES: Although the transfemoral approach for transcatheter aortic valve replacement is the preferred choice, alternative access remains indicated for inadequate iliofemoral vessels. We report the successful implementation of a novel fast-track (FT) protocol for patients undergoing alternative access transcatheter aortic valve replacement compared with conventional controls. METHODS: Between September 2014 and January 2017, 31 and 23 patients underwent alternative access transcatheter aortic valve replacement under FT and pre-fast-track (p-FT) protocols, respectively. Comparisons of outcomes (in terms of mortality, complications, readmissions and resource utilization) were made before and after the implantation of the FT protocol in September 2015. RESULTS: Overall, mean age was 78.7 years in FT and 79.6 years in p-FT patients (P = 0.71). There were no significant differences in procedural (3.2% vs 13.0%, P = 0.301) or 90-day mortality (3.2% vs 17.4%, P = 0.151) between the FT and p-FT groups, respectively. Compared with p-FT patients, FT patients had significantly shorter intensive care unit stays (12 h vs 27 h, P = 0.006) and a trend towards more discharges within 3 days (41.9% vs 17.4%, P = 0.081). Resource utilization analyses projected a 56% and 17% reduction in the mean intensive care unit time (hours) per 100 patients and the total length of stay (days) per 100 patients, respectively, with respect to the FT approach. CONCLUSIONS: This pilot study demonstrates the feasibility and safety of the novel FT protocol for alternative access transcatheter aortic valve replacement, resulting in shorter intensive care unit stays, without increasing procedural complications or readmissions. With the expected increase in transcatheter aortic valve replacement utilization, FT protocols should be integrated with a multidisciplinary heart team approach to enhance patient recovery and optimize resource utilization.