Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Transfusion ; 55(4): 919-25, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25393883

RESUMEN

BACKGROUND: The administration of blood products is frequently determined by physicians without subspecialty training in transfusion medicine (TM). Education in TM is necessary for appropriate utilization of resources and maintaining patient safety. Our institution developed an efficient simulation-based TM course with the goal of identifying key topics that could be individualized to learners of all levels in various environments while also allowing for practice in an environment where the patient is not placed at risk. STUDY DESIGN AND METHODS: A 2.5-hour simulation-based educational activity was designed and taught to undergraduate medical students rotating through anesthesiology and TM elective rotations and to all Clinical Anesthesia Year 1 (CA-1) residents. Content and process evaluation of the activity consisted of multiple-choice tests and course evaluations. RESULTS: Seventy medical students and seven CA-1 residents were enrolled in the course. There was no significant difference on pretest results between medical students and CA-1 residents. The posttest results for both medical students and CA-1 residents were significantly higher than pretest results. The results of the posttest between medical students and CA-1 residents were not significantly different. CONCLUSION: The TM knowledge gap is not a trivial problem as transfusion of blood products is associated with significant risks. Innovative educational techniques are needed to address the ongoing challenges with knowledge acquisition and retention in already full curricula. Our institution developed a feasible and effective way to integrate TM into the curriculum. Educational activities, such as this, might be a way to improve the safety of transfusions.


Asunto(s)
Simulación por Computador , Instrucción por Computador , Medicina Transfusional/educación , Anestesiología/educación , Transfusión Sanguínea , Curriculum , Educación de Pregrado en Medicina , Evaluación Educacional , Estudios de Factibilidad , Humanos , Internado y Residencia , Estudiantes de Medicina
2.
Phys Med Biol ; 68(18)2023 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-37607560

RESUMEN

Objective.This work presents a method for enhanced detection, imaging, and measurement of the thermal neutron flux.Approach. Measurements were performed in a water tank, while the detector is positioned out-of-field of a 20 MeV ultra-high pulse dose rate electron beam. A semiconductor pixel detector Timepix3 with a silicon sensor partially covered by a6LiF neutron converter was used to measure the flux, spatial, and time characteristics of the neutron field. To provide absolute measurements of thermal neutron flux, the detection efficiency calibration of the detectors was performed in a reference thermal neutron field. Neutron signals are recognized and discriminated against other particles such as gamma rays and x-rays. This is achieved by the resolving power of the pixel detector using machine learning algorithms and high-resolution pattern recognition analysis of the high-energy tracks created by thermal neutron interactions in the converter.Main results. The resulting thermal neutrons equivalent dose was obtained using conversion factor (2.13(10) pSv·cm2) from thermal neutron fluence to thermal neutron equivalent dose obtained by Monte Carlo simulations. The calibrated detectors were used to characterize scattered radiation created by electron beams. The results at 12.0 cm depth in the beam axis inside of the water for a delivered dose per pulse of 1.85 Gy (pulse length of 2.4µs) at the reference depth, showed a contribution of flux of 4.07(8) × 103particles·cm-2·s-1and equivalent dose of 1.73(3) nSv per pulse, which is lower by ∼9 orders of magnitude than the delivered dose.Significance. The presented methodology for in-water measurements and identification of characteristic thermal neutrons tracks serves for the selective quantification of equivalent dose made by thermal neutrons in out-of-field particle therapy.


Asunto(s)
Algoritmos , Electrones , Calibración , Rayos gamma , Neutrones
3.
Phys Med Biol ; 68(14)2023 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-37285847

RESUMEN

Objective. The aim of this study was to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH proton radiotherapy using a pixelated semiconductor detector.Approach. Measurements of the time structure of FLASH irradiations were performed using fast, pixelated spectral detectors based on the Timepix3 (TPX3) chips with two architectures: AdvaPIX-TPX3 and Minipix-TPX3. The latter has a fraction of its sensor coated with a material to increase sensitivity to neutrons. With little or no dead time and an ability to resolve events that are closely spaced in time (tens of nanoseconds), both detectors can accurately determine IRTs as long as pulse pile-up is avoided. To avoid pulse pile-up, the detectors were placed well beyond the Bragg peak or at a large scattering angle. Prompt gamma rays and secondary neutrons were registered in the detectors' sensors and IRTs were calculated based on timestamps of the first charge carriers (beam-on) and the last charge carriers (beam-off). In addition, scan times inx,y, and diagonal directions were measured. The experiment was carried out for various setups: (i) a single spot, (ii) a small animal field, (iii) a patient field, and (iv) an experiment using an anthropomorphic phantom to demonstratein vivoonline monitoring of IRT. All measurements were compared to vendor log files.Main results. Differences between measurements and log files for a single spot, a small animal field, and a patient field were within 1%, 0.3% and 1%, respectively.In vivomonitoring of IRTs (95-270 ms) was accurate within 0.1% for AdvaPIX-TPX3 and within 6.1% for Minipix-TPX3. The scan times inx,y, and diagonal directions were 4.0, 3.4, and 4.0 ms, respectively.Significance. Overall, the AdvaPIX-TPX3 can measure FLASH IRTs within 1% accuracy, indicating that prompt gamma rays are a good surrogate for primary protons. The Minipix-TPX3 showed a somewhat higher discrepancy, likely due to the late arrival of thermal neutrons to the detector sensor and lower readout speed. The scan times (3.4 ± 0.05 ms) in the 60 mm distance ofy-direction were slightly less than (4.0 ± 0.06 ms) in the 24 mm distance ofx-direction, confirming the much faster scanning speed of the Y magnets than that of X. Diagonal scan speed was limited by the slower X magnets.


Asunto(s)
Terapia de Protones , Radiometría , Radiometría/métodos , Rayos gamma , Terapia de Protones/métodos , Protones , Neutrones
4.
Phys Med Biol ; 68(10)2023 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-37011632

RESUMEN

Objective.Protons have advantageous dose distributions and are increasingly used in cancer therapy. At the depth of the Bragg peak range, protons produce a mixed radiation field consisting of low- and high-linear energy transfer (LET) components, the latter of which is characterized by an increased ionization density on the microscopic scale associated with increased biological effectiveness. Prediction of the yield and LET of primary and secondary charged particles at a certain depth in the patient is performed by Monte Carlo simulations but is difficult to verify experimentally.Approach.Here, the results of measurements performed with Timepix detector in the mixed radiation field produced by a therapeutic proton beam in water are presented and compared to Monte Carlo simulations. The unique capability of the detector to perform high-resolution single particle tracking and identification enhanced by artificial intelligence allowed to resolve the particle type and measure the deposited energy of each particle comprising the mixed radiation field. Based on the collected data, biologically important physics parameters, the LET of single protons and dose-averaged LET, were computed.Main results.An accuracy over 95% was achieved for proton recognition with a developed neural network model. For recognized protons, the measured LET spectra generally agree with the results of Monte Carlo simulations. The mean difference between dose-averaged LET values obtained from measurements and simulations is 17%. We observed a broad spectrum of LET values ranging from a fraction of keVµm-1to about 10 keVµm-1for most of the measurements performed in the mixed radiation fields.Significance.It has been demonstrated that the introduced measurement method provides experimental data for validation of LETDor LET spectra in any treatment planning system. The simplicity and accessibility of the presented methodology make it easy to be translated into a clinical routine in any proton therapy facility.


Asunto(s)
Terapia de Protones , Humanos , Terapia de Protones/métodos , Protones , Inteligencia Artificial , Transferencia Lineal de Energía , Dosificación Radioterapéutica , Método de Montecarlo , Radiometría
5.
Phys Med ; 106: 102529, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36657235

RESUMEN

Stray radiation produced by ultra-high dose-rates (UHDR) proton pencil beams is characterized using ASIC-chip semiconductor pixel detectors. A proton pencil beam with an energy of 220 MeV was utilized to deliver dose rates (DR) ranging from conventional radiotherapy DRs up to 270 Gy/s. A MiniPIX Timepix3 detector equipped with a silicon sensor and integrated readout electronics was used. The chip-sensor assembly and chipboard on water-equivalent backing were detached and immersed in the water-phantom. The deposited energy, particle flux, DR, and the linear energy transfer (LET(Si)) spectra were measured in the silicon sensor at different positions both laterally, at different depths, and behind the Bragg peak. At low-intensity beams, the detector is operated in the event-by-event data-driven mode for high-resolution spectral tracking of individual particles. This technique provides precise energy loss response and LET(Si) spectra with radiation field composition resolving power. At higher beam intensities a rescaling of LET(Si) can be performed as the distribution of the LET(Si) spectra exhibits the same characteristics regardless of the delivered DR. The integrated deposited energy and the absorbed dose can be thus measured in a wide range. A linear response of measured absorbed dose was obtained by gradually increasing the delivered DR to reach UHDR beams. Particle tracking of scattered radiation in data-driven mode could be performed at DRs up to 0.27 Gy/s. In integrated mode, the saturation limits were not reached at the measured out-of-field locations up to the delivered DR of over 270 Gy/s. A good agreement was found between measured and simulated absorbed doses.


Asunto(s)
Terapia de Protones , Radiometría , Radiometría/métodos , Protones , Silicio , Transferencia Lineal de Energía , Agua , Terapia de Protones/métodos
6.
Phys Med ; 101: 79-86, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35985102

RESUMEN

The track structure of the signal measured by the semiconductor pixel detector Timepix3 was modelled in the Monte Carlo MCNP® code. A detailed model at the pixel-level (256 × 256 pixels, 55 × 55 µm2 pixel size) was developed and used to generate and store clusters of adjacent hit pixels observed in the measured data because of particle energy deposition path, charge sharing, and drift processes. An analytical model of charge sharing effect and the detector energy resolution was applied to the simulated data. The method will help the user sort the measured clusters and distinguish radiation components of mixed fields by determining the response of Timepix3 detector to particular particle types, energies, and incidence angles that cannot be measured separately.

7.
J Wound Ostomy Continence Nurs ; 38(1): 77-87, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21287773

RESUMEN

PURPOSE: The purpose of the study was to discover which patient and support system characteristics and interventions documented by home health clinicians were associated with improvement in urinary and bowel incontinence contrasting logistic regression and data mining approaches. SUBJECTS AND SETTING: Seventeen hundred ninety-three patients in this study experienced 2072 episodes of care. The study sample comprised all nonmaternity patients aged 18 years or older receiving skilled home health services in 2004. Subjects were drawn from a convenience sample of 15 home health agencies . DESIGN: We completed a secondary analysis of data from 15 home health agencies' electronic health records. Data for this study were documented by home care clinicians using the Outcome and Assessment Information Set (OASIS) structured assessment form and the Omaha System interventions, which is a standardized terminology. RESULTS: There were 684 patients with urinary incontinence and 187 with bowel incontinence. By discharge 38% improved in urinary incontinence and 45% improved their bowel incontinence. Using logistic regression, no patient or support system characteristics were identified that associated with improvement in either urinary or bowel incontinence, only a limited number of interventions were significant. A data mining decision tree was producible only for bowel incontinence, demonstrating a combination of patient and support system factors as well as selected interventions were important in determining whether patients would improve in bowel incontinence. CONCLUSIONS: Home health patients have complex comorbid conditions requiring home care nurses to have broad, generalized knowledge. Future research is needed to determine if the inclusion of a certified WOC nurse would improve outcomes.


Asunto(s)
Registros Electrónicos de Salud/estadística & datos numéricos , Incontinencia Fecal/enfermería , Servicios de Atención de Salud a Domicilio , Evaluación en Enfermería/métodos , Evaluación de Resultado en la Atención de Salud/métodos , Incontinencia Urinaria/enfermería , Anciano , Anciano de 80 o más Años , Algoritmos , Minería de Datos/métodos , Árboles de Decisión , Incontinencia Fecal/epidemiología , Femenino , Servicios de Atención de Salud a Domicilio/organización & administración , Humanos , Modelos Logísticos , Masculino , Minnesota/epidemiología , Enfermeras Clínicas , Rol de la Enfermera , Investigación en Evaluación de Enfermería , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Incontinencia Urinaria/epidemiología
8.
Phys Med Biol ; 66(4): 045003, 2021 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-33296888

RESUMEN

The presence of artificial implants complicates the delivery of proton therapy due to inaccurate characterization of both the implant and the surrounding tissues. In this work, we describe a method to characterize implant and human tissue mimicking materials in terms of relative stopping power (RSP) using a novel proton counting detector. Each proton is tracked by directly measuring the deposited energy along the proton track using a fast, pixelated spectral detector AdvaPIX-TPX3 (TPX3). We considered three scenarios to characterize the RSPs. First, in-air measurements were made in the presence of metal rods (Al, Ti and CoCr) and bone. Then, measurements of energy perturbations in the presence of metal implants and bone in an anthropomorphic phantom were performed. Finally, sampling of cumulative stopping power (CSP) of the phantom were made at different locations of the anthropomorphic phantom. CSP and RSP information were extracted from energy spectra at each beam path. To quantify the RSP of metal rods we used the shift in the most probable energy (MPE) of CSP from the reference CSP without a rod. Overall, the RSPs were determined as 1.48, 2.06, 3.08, and 5.53 from in-air measurements; 1.44, 1.97, 2.98, and 5.44 from in-phantom measurements, for bone, Al, Ti and CoCr, respectively. Additionally, we sampled CSP for multiple paths of the anthropomorphic phantom ranging from 18.63 to 25.23 cm deriving RSP of soft tissues and bones in agreement within 1.6% of TOPAS simulations. Using minimum error of these multiple CSP, optimal mass densities were derived for soft tissue and bone and they are within 1% of vendor-provided nominal densities. The preliminary data obtained indicates the proposed novel method can be used for the validation of material and density maps, required by proton Monte Carlo Dose calculation, provided by competing multi-energy computed tomography and metal artifact reduction techniques.


Asunto(s)
Método de Montecarlo , Fantasmas de Imagen , Prótesis e Implantes , Terapia de Protones/instrumentación , Humanos
9.
Comput Inform Nurs ; 28(3): 162-71, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20431359

RESUMEN

Federal and state initiatives are aligning around the goal that by 2014 all Americans will have electronic health records to support access to their health information any time and anywhere. As a key healthcare provider, nursing data must be included to enhance patient safety, effectiveness, and efficiency of care that is patient-centric. The purpose of this study was to test the feasibility of abstracting, integrating, and comparing the effective use of a standardized terminology, the Omaha System, across software vendors and 15 home care agencies. Results showed that the 2900 patients in this study had an average of four problems on care plans, with interventions most frequently addressing surveillance (39%) and teaching (30%). Findings in this study support the feasibility of integrating data across software vendors and agencies as well as the usefulness for describing care provided in home care. However, before exchanging data across systems, data quality issues found in this study need attention. There were missing data for 10.8% of patients as well as concerns about the validity of using the problem rating scale for outcomes. Strategies for effective use of standardized nursing terminologies are recommended.


Asunto(s)
Servicios Contratados/organización & administración , Agencias de Atención a Domicilio/organización & administración , Integración de Sistemas , Estudios de Factibilidad , Sistemas de Registros Médicos Computarizados
10.
Clin Gastroenterol Hepatol ; 7(12): 1335-40, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19665583

RESUMEN

BACKGROUND & AIMS: There has been no prospective, community-based study to track changes in adenoma detection by individual physicians over time and to determine the effectiveness of targeted educational interventions. METHODS: We prospectively collected information on 47,253 screening colonoscopies in average-risk individuals 50 years and older performed by a community-based practice in the Twin Cities of Minnesota. During a period of 3 years, 5 specific interventions were implemented; each was designed to improve adenoma detection rates. Controlling for patient-related and procedure-related factors, rates of adenoma detection and 3-year trends for individual physicians were plotted, and intraclass correlation coefficients were calculated. Generalized estimating equations were used to identify factors associated with detection of adenomas and polyps. RESULTS: At least 1 polyp and 1 adenoma were found in 36% and 22% of examinations, respectively. Adenoma detection rates by endoscopists ranged from 10%-39%. There was no significant improvement during the study period despite planned, systematic interventions. Factors associated with adenoma detection included age of the patient (odds ratio [OR], 1.02; 95% confidence interval [CI], 1.02-1.02), male sex (OR, 1.53; 95% CI, 1.34-1.74), and adequate preparation quality (OR, 2.26; 95% CI, 1.64-3.12). CONCLUSIONS: The detection of adenomas by individual physicians during a 3-year period varied and did not appear to change between individual endoscopists, despite planned, systematic interventions. This indicates that other targeted interventions might be required to improve adenoma detection rates among experienced, community gastroenterologists.


Asunto(s)
Adenoma/diagnóstico , Neoplasias del Colon/diagnóstico , Colonoscopía/métodos , Colonoscopía/normas , Investigación sobre Servicios de Salud , Pólipos/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Minnesota , Variaciones Dependientes del Observador
11.
Surg Infect (Larchmt) ; 11(1): 33-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19785562

RESUMEN

BACKGROUND: Inadequate antibiotic therapy and failure to administer antibiotics in a timely fashion have been associated with substantial mortality rates in patients in the intensive care unit (ICU). We analyzed the infection pattern in solid organ transplant recipients as well as the impact of antibiotic resistance and inadequate antibiotic treatment on mortality rates and morbidity outcomes. METHODS: Charts of adult solid organ transplant recipients in 2006 from a single institution were reviewed. Data on patients with bacterial and fungal infections acquired within one year after transplantation were compared with the primary outcome of death within 28 days. Statistical analysis included nonparametric tests (Wilcoxon rank sum, Fisher exact, and chi-square) and multivariable logistic regression with p < 0.05 considered significant. RESULTS: Of the 366 patients, 114 (31%) had a total of 208 bacterial or fungal infections, and 44 of them (39%) were admitted to the ICU. Our primary endpoint, the 28-day mortality rate, was 8% overall, whereas the six-month mortality rate was 11%. Patients treated inadequately with antibiotics had a significantly higher mortality rate. The leading causes of infection were multiple organisms, coagulase-negative Staphylococcus, and E. coli, of which 76% were resistant to antibiotics. Antibiotic-resistant infections were associated with longer hospital stays (p = 0.04), intravenous antibiotic use prior to infection (p = 0.04), nucleotide synthesis inhibitor use (p = 0.02), ICU admission (p < 0.01), and respiratory failure (p = 0.03). Most infections were treated inadequately initially (69%) but treated adequately at 24 h (56%). Inadequate antibiotic treatment was significantly associated with younger age (p = 0.04), prior intravenous antibiotic use (p = 0.04), longer stay prior to infection (p = 0.05), and cardiovascular shock (p = 0.014). Inadequate antibiotic therapy at 24 h was associated with a higher mortality rate (14% vs. 2%; p = 0.03) and a trend toward longer ICU and in-hospital stays. CONCLUSIONS: Most bacterial and fungal infections were resistant to antibiotics and were treated inadequately initially. Prior intravenous antibiotic use and longer stay prior to infection were associated with antibiotic resistance and inadequate antibiotic therapy. Failure to provide adequate antibiotic treatment within 24 h had a significant impact on the 28-day mortality rate and was associated with other detrimental clinical outcomes.


Asunto(s)
Antibacterianos/uso terapéutico , Infecciones Bacterianas/tratamiento farmacológico , Infecciones Bacterianas/mortalidad , Infección Hospitalaria/tratamiento farmacológico , Infección Hospitalaria/mortalidad , Micosis/tratamiento farmacológico , Micosis/mortalidad , Adolescente , Adulto , Anciano , Animales , Bacterias/efectos de los fármacos , Bacterias/aislamiento & purificación , Cuidados Críticos , Farmacorresistencia Bacteriana , Farmacorresistencia Fúngica , Femenino , Hongos/efectos de los fármacos , Hongos/aislamiento & purificación , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Trasplantes/efectos adversos , Adulto Joven
12.
AMIA Annu Symp Proc ; : 908, 2008 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-18998807

RESUMEN

A comparison of traditional statistical techniques and knowledge discovery in database techniques is presented for examining risk factors and interventions predictive of incontinence and pressure ulcers for homecare patients. The data set consists of OASIS (Outcome and Assessment Information Set) and intervention data from the Omaha System from 15 homecare agencies.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas/organización & administración , Técnicas de Apoyo para la Decisión , Úlcera por Presión/enfermería , Úlcera por Presión/prevención & control , Modelos de Riesgos Proporcionales , Incontinencia Urinaria/enfermería , Incontinencia Urinaria/prevención & control , Interpretación Estadística de Datos , Servicios de Atención de Salud a Domicilio , Humanos , Incidencia , Nebraska/epidemiología , Úlcera por Presión/epidemiología , Medición de Riesgo/métodos , Factores de Riesgo , Incontinencia Urinaria/epidemiología
13.
AMIA Annu Symp Proc ; : 930, 2008 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-18999187

RESUMEN

Complexity of medication regimens in community dwelling elders is examined in relationship to emergent care use, hospitalization and self management of medications in this secondary data analysis of OASIS data and medication data from all 2004 open admissions to 15 home health care agencies. Preliminary findings and the use of innovative techniques are discussed highlighting the predictive potential for medication complexity in other settings, risk stratification, and design implications for both clinical tools and databases.


Asunto(s)
Servicios de Salud Comunitaria/organización & administración , Servicios de Información sobre Medicamentos/organización & administración , Servicios de Salud para Ancianos/organización & administración , Servicios de Atención de Salud a Domicilio/organización & administración , Evaluación de Resultado en la Atención de Salud/métodos , Minnesota
14.
Am J Gastroenterol ; 100(7): 1446-54, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15984964

RESUMEN

BACKGROUND: Esophageal candidiasis (EC) remains one of the most common AIDS defining illnesses in patients with human immunodeficiency virus (HIV) in the era of highly active antiretroviral therapy (HAART), but little is known about factors associated with EC after starting HAART. OBJECTIVES: To describe changes in the use of antimycotic medication, the incidence of EC and factors associated with EC before and after starting HAART. METHODS: Patients from EuroSIDA, a pan-European longitudinal, prospective observational study. Generalized linear models and poisson regression models were used to investigate the relationships. RESULTS: A total of 9,873 patients did not have EC at recruitment, subsequently 537 (15.8%) developed EC. The proportion of patients taking any antimycotic dropped from 18% at January 1995 to 2% at January 2004 (p < 0.0001); the duration of treatment declined from 10 to 3 months over the same period (p < 0.0001). There was a 32% annual decline in the incidence of EC (95% CI 30-35%, p < 0.0001). There was a significant annual decline in the incidence of EC pre-HAART in time-updated, adjusted models, (incidence rate ratio (IRR) 0.80, 95% CI 0.76-0.85, p < 0.0001) but not post-HAART (IRR 0.97; 95% CI 0.90-1.06, p= 0.54). Older patients and those with low CD4 counts had the greatest incidence of EC in the post-HAART era. CONCLUSIONS: There has been a marked decline in the incidence of EC between 1994 and 2004. This was accompanied by a decline in markers associated with fungal disease, including use of antimycotics and a decline in duration of treatment.


Asunto(s)
Infecciones Oportunistas Relacionadas con el SIDA/tratamiento farmacológico , Infecciones Oportunistas Relacionadas con el SIDA/epidemiología , Antifúngicos/uso terapéutico , Terapia Antirretroviral Altamente Activa , Candidiasis/tratamiento farmacológico , Candidiasis/epidemiología , Enfermedades del Esófago/tratamiento farmacológico , Enfermedades del Esófago/epidemiología , Antifúngicos/administración & dosificación , Esquema de Medicación , Europa (Continente)/epidemiología , Femenino , Infecciones por VIH/tratamiento farmacológico , Humanos , Incidencia , Modelos Lineales , Estudios Longitudinales , Masculino , Distribución de Poisson , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA