Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Monit Assess ; 189(11): 574, 2017 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-29046968

RESUMEN

Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.


Asunto(s)
Monitoreo del Ambiente/métodos , Filtración/métodos , Aguas Residuales/virología , Microbiología del Agua , Adsorción , Humanos , Concentración de Iones de Hidrógeno , Poliovirus , Agua
2.
PLoS One ; 16(5): e0251664, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34014964

RESUMEN

Exposure to ultrafine combustion aerosols such as particulate matter (PM) from residential woodburning, forest fires, cigarette smoke, and traffic emission have been linked to adverse health outcomes. Excitation-emission matrix (EEM) spectroscopy presents a sensitive and cost-effective alternative for analysis of PM organic fraction. However, as with other analytical chemistry methods, the miniaturization is hindered by a solvent extraction step and a need for benchtop instrumentation. We present a methodology for collecting and in-situ analysis of airborne nanoparticles that eliminates labor-intensive sample preparation and miniaturizes the detection platform. Nanoparticles are electrostatically collected onto a transparent substrate coated with solid-phase (SP) solvent-polydimethylsiloxane (PDMS). The PM organic fraction is extracted into PDMS and analyzed in-situ, thus avoiding liquid-phase extraction. In the SP-EEM analysis, we evaluated external and internal excitation schemes. Internal excitation shows the lowest scattering interference but leads to signal masking from PDMS fluorescence for λ<250nm. The external excitation EEM spectra are dependent on the excitation light incident angle; ranges of 30-40° and 55-65° show the best results. SP-EEM spectra of woodsmoke and cigarette smoke samples are in good agreement with the EEM spectra of liquid-phase extracts. The SP-EEM technique can be used to develop wearable sensors for exposure assessments and environmental monitoring.


Asunto(s)
Material Particulado/análisis , Contaminantes Químicos del Agua/análisis , Aerosoles , Espectrometría de Fluorescencia
3.
Talanta ; 234: 122633, 2021 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-34364442

RESUMEN

The detection of trace amounts of explosive materials is critical to the security at mass transit centers (e.g., airports and railway stations). In a typical screening process, a trap is used to probe a surface of interest to collect and transfer particulate residue to a detector for analysis. The collection of residues from the surface being probed is widely viewed as the limiting step in this process. A multi-institutional study was performed to establish a methodology for the evaluation of sampling media collection efficiencies. Dry deposited residues of 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), C-4 (an RDX-based explosive), and pentaerythritol tetranitrate (PETN) were harvested from acrylonitrile butadiene styrene (ABS) plastic, ballistic nylon (NYL), and uncoated aluminum surfaces using muslin, Texwipe cotton, and stainless-steel mesh traps. Transfer and collection efficiencies of the sample media were calculated based on liquid chromatography-mass spectrometry analysis. Dry transfer efficiencies (DTE%) to all tested surfaces were greater than 75%, with transfer to ABS plastic being the lowest. Collection efficiency (CE%) varied significantly across the traps and the surfaces, yet some conclusions can be drawn; nylon had the lowest CE% for all cases (∼10%), and the stainless steel mesh had the lowest CE% for the evaluated traps (∼20%). Though the testing parameters have been standardized among the participants to establish a framework for an independent comparison of contact sampling media and surfaces, substantial variations in the DTE% and the CE% were observed, suggesting that other variables can affect contact sampling.


Asunto(s)
Sustancias Explosivas , Tetranitrato de Pentaeritritol , Humanos , Espectrometría de Masas , Textiles , Triazinas
4.
JMIR Mhealth Uhealth ; 6(12): e12023, 2018 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-30578204

RESUMEN

BACKGROUND: There is considerable evidence that exposure to fine particulate matter (PM2.5) air pollution is associated with a variety of adverse health outcomes. However, true exposure-outcome associations are hampered by measurement issues, including compliance and exposure misclassification. OBJECTIVE: This paper describes the use of the design-feedback iterative cycle to improve the design and usability of a new portable PM2.5 monitor for use in an epidemiologic study of personal air pollution measures. METHODS: In total, 10 adults carried on their person a prefabricated PM2.5 monitor for 1 week over 3 waves of the iterative cycle. At the end of each wave, they participated in a 30-minute moderated focus group and completed 2 validated questionnaires on usability and views on research. The topics addressed included positives and negatives of the monitor, charging and battery life, desired features, and changes to the monitor from each previous wave. They also completed a log to record device wear time each day. The log also provided space to record any issues that may have arisen with the device or for general comments during the week of collection. RESULTS: The major focus group topics included device size, noise, battery and charge time, and method for carrying the device. These topics formed the basis of iterative design changes; by the final cycle, the device was reasonably smaller, quieter, held a longer charge, and was more convenient to carry. System usability scores improved systematically across each wave (median scores of 50-66 on a 100-point scale), as did median daily wear time (approximately 749-789 minutes). CONCLUSIONS: Both qualitative and quantitative measures showed an improvement in device usability over the 3 waves. This study demonstrates how the design-feedback iterative cycle can be used to improve the usability of devices manufactured for use in large epidemiologic studies on personal air pollution exposures.

5.
Food Environ Virol ; 10(1): 72-82, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28674934

RESUMEN

Environmental surveillance of poliovirus (PV) plays an important role in the global program for eradication of wild PV. The bag-mediated filtration system (BMFS) was first developed in 2014 and enhances PV surveillance when compared to the two-phase grab method currently recommended by the World Health Organization (WHO). In this study, the BMFS design was improved and tested for its usability in wastewater and wastewater-impacted surface waters in Nairobi, Kenya. Modifications made to the BMFS included the size, color, and shape of the collection bags, the filter housing used, and the device used to elute the samples from the filters. The modified BMFS concentrated 3-10 L down to 10 mL, which resulted in an effective volume assayed (900-3000 mL) that was 6-20 times greater than the effective volume assayed for samples processed by the WHO algorithm (150 mL). The system developed allows for sampling and in-field virus concentration, followed by transportation of the filter for further analysis with simpler logistics than the current methods. This may ultimately reduce the likelihood of false-negative samples by increasing the effective volume assayed compared to samples processed by the WHO algorithm, making the BMFS a valuable sampling system for wastewater and wastewater-impacted surface waters.


Asunto(s)
Monitoreo del Ambiente/métodos , Filtración/métodos , Poliomielitis/virología , Poliovirus/crecimiento & desarrollo , Aguas Residuales/virología , Contaminación del Agua , Humanos , Kenia , Aguas del Alcantarillado/virología , Agua , Microbiología del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA