Radiat Prot Dosimetry ; 120(1-4): 136-9, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16614090

RESUMEN

To measure dose distribution for X- and gamma rays simply and accurately, a tissue-equivalent thermoluminescent (TL) sheet-type dosemeter and reader system were developed. The TL sheet is composed of LiF:Mg,Cu,P and ETFE polymer, and the thickness is 0.2 mm. For the TL reading, a square heating plate, 20 cm on each side, was developed, and the temperature distribution was measured with an infrared thermal imaging camera. As a result, linearity within 2% and the homogeneity within 3% were confirmed. The TL signal emitted is detected using a CCD camera and displayed as a spatial dose distribution. Irradiation using synchrotron radiation between 10 and 100 keV and (60)Co gamma rays showed that the TL sheet dosimetry system was promising for radiation dose mapping for various purposes.


Asunto(s)
Biomimética/instrumentación , Fluoruros/química , Fluoruros/efectos de la radiación , Compuestos de Litio/química , Compuestos de Litio/efectos de la radiación , Protección Radiológica/instrumentación , Dosimetría Termoluminiscente/instrumentación , Biomimética/métodos , Carga Corporal (Radioterapia) , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Rayos gamma , Humanos , Ensayo de Materiales , Membranas Artificiales , Dosis de Radiación , Protección Radiológica/métodos , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Dosimetría Termoluminiscente/métodos , Rayos X
2.
Radiat Prot Dosimetry ; 115(1-4): 95-9, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381690

RESUMEN

A passively safe small reactor for a distributed energy system, PSRD, is an integral type of light-water reactor with a thermal output of 100 or 300 MW aimed to be used for supplying district heat, electricity to small grids, and so on. Candidate locations for the PSRD as a distributed energy source are on-ground, deep underground, and in a seaside pit in the vicinity of the energy consumption area. Assessments of the radiation safety of a PSRD were carried out for three cases corresponding to normal operation, shutdown and a hypothetical postulated accident for several siting candidates. Results of the radiation safety assessment indicate that the PSRD design has sufficient shielding performance and capability and that the exposure to the general public is very low in the case of a hypothetical accident.


Asunto(s)
Seguridad de Equipos/métodos , Modelos Teóricos , Reactores Nucleares , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Medición de Riesgo/métodos , Algoritmos , Simulación por Computador , Transferencia de Energía , Falla de Equipo , Análisis de Falla de Equipo/métodos , Seguridad de Equipos/instrumentación , Arquitectura y Construcción de Instituciones de Salud/métodos , Japón , Neutrones , Fotones , Dosis de Radiación , Protección Radiológica/instrumentación , Factores de Riesgo
3.
Radiat Prot Dosimetry ; 115(1-4): 334-6, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381741

RESUMEN

Energy response of LiF:Mg,Ti, LiF:Mg,Cu,P and Mg2SiO4:Tb thermoluminescence dosemeters (TLDs) was measured in the range 10-150 keV for monoenergetic photons at SPring-8 of an 8-GeV synchrotron radiation facility. The photon beam was monitored by a parallel-plate free-air ionisation chamber calibrated with an uncertainty of 3%. Owing to the small dimension of the beam, a rotating holder was designed in order to irradiate TLDs uniformly. The measured responses of LiF to energy were approximately in agreement with the calculated dose absorption dependence in the soft tissue. However, two types of LiF TLDs presented the different luminescent responses to the photon energy. The response of LiF:Mg,Ti had a smooth curve, and that of LiF:Mg,Cu,P presented a local maximum at 30 keV and a local minimum at 100 keV. The Mg2SiO4:Tb response was nearly bone equivalent. Linearity of dose responses was also confirmed up to 2 Gy on each TL material.


Asunto(s)
Fluoruros/efectos de la radiación , Transferencia Lineal de Energía/efectos de la radiación , Compuestos de Litio/efectos de la radiación , Silicatos de Magnesio/efectos de la radiación , Fotones , Protección Radiológica/instrumentación , Dosimetría Termoluminiscente/instrumentación , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Fluoruros/química , Compuestos de Litio/química , Silicatos de Magnesio/química , Ensayo de Materiales , Dosis de Radiación , Protección Radiológica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Dosimetría Termoluminiscente/métodos
4.
Radiat Prot Dosimetry ; 111(1): 65-71, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15367771

RESUMEN

In usual personal dosimetry, whole body irradiation is assumed. However, the opportunity of partial irradiation is increasing and the tendencies of protection quantities caused under those irradiation conditions are different. The code system has been developed and effective dose and organ absorbed doses have been calculated in the case of horizontal narrow photon beam irradiated from various directions at three representative body sections, 40, 50 and 60 cm originating from the top of the head. This work covers 24 beam directions, each 15 degrees angle ranging from 0 degrees to 345 degrees, three energy levels, 45 keV, 90 keV and 1.25 MeV, and three beam diameters of 1, 2 and 4 cm. These results show that the beam injected from diagonally front or other specific direction causes peak dose in the case of partial irradiation.


Asunto(s)
Simulación por Computador , Modelos Teóricos , Método de Montecarlo , Fotones , Dosis de Radiación , Distribución Tisular , Tamaño Corporal , Humanos , Especificidad de Órganos , Dispersión de Radiación , Irradiación Corporal Total