Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Endocr Pract ; 11(4): 240-53, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16006296

RESUMEN

OBJECTIVE: To assess the efficacy and safety of intravenous (IV) insulin administration with use of our institution's old protocol (pre-nomogram phase) as compared with our new insulin nomogram (post-nomogram phase), which titrates insulin dose based on the rate of change of plasma glucose values and uses multipliers to determine the new insulin infusion rate. METHODS: Hospitalized adults receiving an IV insulin infusion in our tertiary care medical center were enrolled in this study after informed consent was obtained. The study was an observational analysis conducted before and after implementation of the new insulin infusion nomogram. Measurements included episodes of hypoglycemia and incidence of the following errors in the insulin infusion process: (1) episodes of documented failure to increase insulin infusion rate despite persistent hyperglycemia and (2) number of times the IV infusion was stopped without subcutaneous administration of insulin. RESULTS: Overall, 66 patients were analyzed (38 in the pre-nomogram phase and 28 in the post-nomogram phase). The new nomogram reduced by nearly 3-fold (from 0.89 +/- 0.68 to 0.36 +/- 0.49 occurrence per patient per 24 hours; P<0.001) the mean incidence of failure to give insulin subcutaneously before discontinuation of IV insulin infusion. Moreover, the nomogram nearly eliminated the error of caregiver nonresponsiveness to persistent hyperglycemia: mean incidence 0.39 +/- 0.65 occurrence per patient per 24 hours before implementation of the new nomogram versus 0.02 +/- 0.09 afterward (P<0.002). There was no statistically significant difference in episodes of hypoglycemia between the 2 study groups. CONCLUSION: Safe IV administration of insulin through error prevention is essential. Implementation of a new IV insulin infusion nomogram, which adjusts insulin infusion using multipliers, reduces errors and improves glycemic control without increasing hypoglycemic episodes.


Asunto(s)
Hiperglucemia/tratamiento farmacológico , Insulina/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Glucemia/metabolismo , Femenino , Humanos , Hiperglucemia/sangre , Infusiones Intravenosas , Unidades de Cuidados Intensivos , Masculino , Errores Médicos/prevención & control , Persona de Mediana Edad , Nomogramas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA