Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; 41(12): 3774-3786, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35921341

RESUMEN

Magnetic particle imaging (MPI) is a rapidly developing medical imaging modality that exploits the non-linear response of magnetic nanoparticles (MNPs). Color MPI widens the functionality of MPI, empowering it with the capability to distinguish different MNPs and/or MNP environments. The system function approach for color MPI relies on extensive calibrations that capture the differences in the harmonic responses of the MNPs. An alternative calibration-free x-space-based method called TAURUS estimates a map of the relaxation time constant, τ , by recovering the underlying mirror symmetry in the MPI signal. However, TAURUS requires a back and forth scanning of a given region, restricting its usage to slow trajectories with constant or piecewise constant focus fields (FFs). In this work, we propose a novel technique to increase the performance of TAURUS and enable τ map estimation for rapid and multi-dimensional trajectories. The proposed technique is based on correcting the distortions on mirror symmetry induced by time-varying FFs. We demonstrate via simulations and experiments in our in-house MPI scanner that the proposed method successfully estimates high-fidelity τ maps for rapid trajectories that provide orders of magnitude reduction in scanning time (over 300 fold for simulations and over 8 fold for experiments) while preserving the calibration-free property of TAURUS.


Asunto(s)
Nanopartículas de Magnetita , Diagnóstico por Imagen/métodos , Magnetismo , Fenómenos Magnéticos
2.
Phys Med Biol ; 64(16): 165018, 2019 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-31342922

RESUMEN

Magnetic particle imaging (MPI) is a fast emerging biomedical imaging modality that exploits the nonlinear response of superparamagnetic iron oxide (SPIO) nanoparticles to image their spatial distribution. Previously, various scanning trajectories were analyzed for the system function reconstruction (SFR) approach, providing important insight regarding their image quality performances. While Cartesian trajectories remain the most popular choice for x-space-based reconstruction, recent work suggests that non-Cartesian trajectories such as the Lissajous trajectory may prove beneficial for improving image quality. In this work, we propose a generalized reconstruction scheme for x-space MPI that can be used in conjunction with any scanning trajectory. The proposed technique automatically tunes the reconstruction parameters from the scanning trajectory, and does not induce any additional blurring. To demonstrate the proposed technique, we utilize five different trajectories with varying density levels. Comparison to alternative reconstruction methods show significant improvement in image quality achieved by the proposed technique. Among the tested trajectories, the Lissajous and bidirectional Cartesian trajectories prove more favorable for x-space MPI, and the resolution of the images from these two trajectories can further be improved via deblurring. The proposed fully automated gridding reconstruction can be utilized with these trajectories to improve the image quality in x-space MPI.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Fenómenos Magnéticos , Imagen Molecular , Algoritmos , Automatización , Compuestos Férricos , Humanos , Fantasmas de Imagen
3.
Forensic Sci Int ; 101(3): 217-27, 1999 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-10404633

RESUMEN

Determination of the manner of death in the case of intra- and perioral firearm wounds can be difficult especially if death scene investigation is unclear and inadequate. In this study, we investigated some characteristics of these firearm wounds which were autopsied in Istanbul. During the 5-year period from 1991 through 1995, there were 15 intra- and perioral firearm fatalities investigated. In all the cases, only one shot was fired into the mouth. They constituted 1% of all the firearm fatalities. The mean age of the victims was 27 years and males constituted 73.3% of the victims. Most of the wounds were caused by handguns. Homicides accounted for 53.3% of these deaths. Three of 15 cases could not be identified as intraoral firearm wounds by general practitioners during the scene investigations.


Asunto(s)
Boca/lesiones , Heridas por Arma de Fuego/patología , Adolescente , Adulto , Femenino , Medicina Legal , Homicidio , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Suicidio , Turquía/epidemiología , Heridas por Arma de Fuego/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA