1.
Lab Chip ; 24(7): 1867-1874, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38487919

RESUMEN

Microfluidic lab-on-a-chip technologies enable the analysis and manipulation of small fluid volumes and particles at small scales and the control of fluid flow and transport processes at the microscale, leading to the development of new methods to address a broad range of scientific and medical challenges. Microfluidic and lab-on-a-chip technologies have made a noteworthy impact in basic, preclinical, and clinical research, especially in hematology and vascular biology due to the inherent ability of microfluidics to mimic physiologic flow conditions in blood vessels and capillaries. With the potential to significantly impact translational research and clinical diagnostics, technical issues and incentive mismatches have stymied microfluidics from fulfilling this promise. We describe how accessibility, usability, and manufacturability of microfluidic technologies should be improved and how a shift in mindset and incentives within the field is also needed to address these issues. In this report, we discuss the state of the microfluidic field regarding current limitations and propose future directions and new approaches for the field to advance microfluidic technologies closer to translation and clinical use. While our report focuses on using blood as the prototypical biofluid sample, the proposed ideas and research directions can be extrapolated to other areas of hematology, oncology, biology, and medicine.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Microfluídica/métodos , Técnicas Analíticas Microfluídicas/métodos , Dispositivos Laboratorio en un Chip , Investigación Biomédica Traslacional
2.
Mol Genet Metab ; 109(2): 218-20, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23578771

RESUMEN

OBJECTIVE: Easy tool for newborn screening of Gaucher and Hurler diseases. METHODS: Method comparison between fluorometric enzymatic activity assay on a digital microfluidic platform and micro-titer plate bench assay was performed on normal (n = 100), Gaucher (n = 10) and Hurler (n = 7) dried blood spot samples. RESULTS: Enzymatic activity analysis of glucocerebrosidase (Gaucher) and α-l-iduronidase (Hurler) revealed similar discrimination between normal and affected samples on both platforms. CONCLUSIONS: Digital microfluidics is suitable for Gaucher and Hurler newborn screening.


Asunto(s)
Pruebas con Sangre Seca/métodos , Enfermedad de Gaucher/diagnóstico , Mucopolisacaridosis I/diagnóstico , Pruebas de Enzimas , Enfermedad de Gaucher/sangre , Glucosilceramidasa/sangre , Humanos , Iduronidasa/sangre , Recién Nacido , Microfluídica , Mucopolisacaridosis I/sangre , Tamizaje Neonatal
3.
Mol Genet Metab ; 105(3): 519-21, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22227323

RESUMEN

Mucopolysaccharidosis type II (MPS II) or Hunter syndrome is a lysosomal storage disease caused by deficiency of iduronate-2-sulfatase (IDS). A convenient single-step fluorometric microplate enzyme assay has been developed and validated for clinical diagnosis of MPS II using dried blood spots (DBS). The assay compared well with a recently reported digital microfluidic method, from which it was adapted. Results show that this DBS assay is robust and reproducible using both technologies.


Asunto(s)
Pruebas con Sangre Seca , Pruebas de Enzimas/métodos , Iduronato Sulfatasa/sangre , Mucopolisacaridosis II/diagnóstico , Fluorometría/métodos , Humanos , Iduronato Sulfatasa/genética , Técnicas Analíticas Microfluídicas , Mucopolisacaridosis II/sangre , Mucopolisacaridosis II/enzimología
4.
Anal Chem ; 83(22): 8439-47, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-21932784

RESUMEN

The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., "sample-to-sequence" capability) could eventually be achieved using this low-cost platform.


Asunto(s)
ADN de Hongos/análisis , ADN de Hongos/genética , Técnicas Analíticas Microfluídicas/métodos , Análisis de Secuencia de ADN/métodos , Secuencia de Bases , Candida/genética , Desoxirribonucleótidos/análisis , Desoxirribonucleótidos/genética , Desoxirribonucleótidos/metabolismo , Electrodos , Enzimas/química , Enzimas/metabolismo , Técnicas Analíticas Microfluídicas/instrumentación , Análisis de Secuencia de ADN/instrumentación , Moldes Genéticos
5.
Clin Chem ; 57(10): 1444-51, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21859904

RESUMEN

BACKGROUND: Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS: We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS: Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS: A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.


Asunto(s)
Pruebas Enzimáticas Clínicas/instrumentación , Enfermedad de Fabry/diagnóstico , Enfermedad del Almacenamiento de Glucógeno Tipo II/diagnóstico , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , alfa-Galactosidasa/sangre , alfa-Glucosidasas/sangre , Fluorometría , Humanos , Recién Nacido , Tamizaje Neonatal
6.
Anal Chem ; 82(6): 2310-6, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-20151681

RESUMEN

This paper details the development of a digital microfluidic platform for multiplexed real-time polymerase chain reactions (PCR). Liquid samples in discrete droplet format are programmably manipulated upon an electrode array by the use of electrowetting. Rapid PCR thermocycling is performed in a closed-loop flow-through format where for each cycle the reaction droplets are cyclically transported between different temperature zones within an oil-filled cartridge. The cartridge is fabricated using low-cost printed-circuit-board technology and is intended to be a single-use disposable device. The PCR system exhibited remarkable amplification efficiency of 94.7%. To test its potential application in infectious diseases, this novel PCR system reliably detected diagnostic DNA levels of methicillin-resistant Staphylococcus aureus (MRSA), Mycoplasma pneumoniae , and Candida albicans . Amplification of genomic DNA samples was consistently repeatable across multiple PCR loops both within and between cartridges. In addition, simultaneous real-time PCR amplification of both multiple different samples and multiple different targets on a single cartridge was demonstrated. A novel method of PCR speed optimization using variable cycle times has also been proposed and proven feasible. The versatile system includes magnetic bead handling capability, which was applied to the analysis of simulated clinical samples that were prepared from whole blood using a magnetic bead capture protocol. Other salient features of this versatile digital microfluidic PCR system are also discussed, including the configurability and scalability of microfluidic operations, instrument portability, and substrate-level integration with other pre- and post-PCR processes.


Asunto(s)
ADN Bacteriano/análisis , ADN de Hongos/análisis , Staphylococcus aureus Resistente a Meticilina/genética , Microfluídica/instrumentación , Reacción en Cadena de la Polimerasa/instrumentación , Candida albicans/genética , ADN Bacteriano/genética , ADN de Hongos/genética , Diseño de Equipo , Mycoplasma pneumoniae/genética
7.
Diagnostics (Basel) ; 10(5)2020 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-32403245

RESUMEN

Interest in newborn screening for mucopolysaccharidoses (MPS) is growing, due in part to ongoing efforts to develop new therapies for these disorders and new screening assays to identify increased risk for the individual MPSs on the basis of deficiency in the cognate enzyme. Existing tests for MPSs utilize either fluorescence or mass spectrometry detection methods to measure biomarkers of disease (e.g., enzyme function or glycosaminoglycans) using either urine or dried blood spot (DBS) samples. There are currently two approaches to fluorescence-based enzyme function assays from DBS: (1) manual reaction mixing, incubation, and termination followed by detection on a microtiter plate reader; and (2) miniaturized automation of these same assay steps using digital microfluidics technology. This article describes the origins of laboratory assays for enzyme activity measurement, the maturation and clinical application of fluorescent enzyme assays for MPS newborn screening, and considerations for future expansion of the technology.

8.
Diagnostics (Basel) ; 10(1)2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31906315

RESUMEN

"Children are not tiny adults" is an adage commonly used in pediatrics to emphasize the fact that children often have different physiological responses to sickness and trauma compared to adults. However, despite widespread acceptance of this concept, diagnostic blood testing is an excellent example of clinical care that is not yet customized to the needs of children, especially newborns. Cumulative blood loss resulting from clinical testing does not typically impact critically ill adult patients, but can quickly escalate in children, leading to iatrogenic anemia and related comorbidities. Moreover, the tests prioritized for rapid, near-patient testing in adults are not always the most clinically relevant tests for children or newborns. This report describes the development of a digital microfluidic testing platform and associated clinical assays purposely curated to address current shortcomings in pediatric laboratory testing by using microliter volumes (<50 µL) of samples. The automated platform consists of a small instrument and single-use cartridges, which contain all reagents necessary to prepare the sample and perform the assay. Electrowetting technology is used to precisely manipulate nanoliter-sized droplets of samples and reagents inside the cartridge. To date, we have automated three disparate types of assays (biochemical assays, immunoassays, and molecular assays) on the platform and have developed over two dozen unique tests, each with important clinical application to newborns and pediatric patients. Cell lysis, plasma preparation, magnetic bead washing, thermocycling, incubation, and many other essential functions were all performed on the cartridge without any user intervention. The resulting assays demonstrate performance comparable to standard clinical laboratory assays and are economical due to the reduced hands-on effort required for each assay and lower overall reagent consumption. These capabilities allow a wide range of assays to be run simultaneously on the same cartridge using significantly reduced sample volumes with results in minutes.

9.
Pract Lab Med ; 18: e00141, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31720353

RESUMEN

BACKGROUND: Decreased galactocerebrosidase (GALC) enzyme activity is causative for Krabbe disease, a lysosomal storage disorder with devastating neurodegenerative consequences. Quantitative fluorimetric assays for GALC activity in isolated blood and skin cells have been described; however, no such assay has been described using dried blood spot (DBS) specimens. METHODS: GALC enzyme activity was measured quantitatively using fluorescence from a novel glycosidic substrate: carboxy derived from 6-hexadecanoylamino-4-methylumbelliferone. GALC activity was demonstrated on newborn DBS specimens, known Krabbe disease patient specimens, proficiency testing and quality control samples. RESULTS: We present data on characterization of the novel substrate and assay, including pH optimization and enzyme kinetics using a fluorimetric profile. Single and multi-day precision analyses revealed tight analytical measurements with %CV ranging from 5.2% to 14.1%. GALC enzyme activity was linear over the range of 0.31 - 12.04 µmol/l/h with a limit of detection of 0.066 µmol/l/h. Our results with this assay show a clear discrimination between GALC activities in samples from Krabbe disease patients versus presumed normal newborn samples. CONCLUSIONS: A fluorimetric assay for GALC enzyme activity measurement on dried blood spot specimens is feasible. Improvements to the assay including novel substrate design, increased substrate concentration and removal of sodium chloride maximize the specificity of the assay and minimize interference from ß-galactosidase.

10.
Lab Chip ; 8(12): 2188-96, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19023486

RESUMEN

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore does not suffer from clogging of channels. Immunoassays on a digital microfluidic platform require the following basic operations: bead attraction, bead washing, bead retention, and bead resuspension. Several parameters such as magnetic field strength, pull force, position, and buffer composition were studied for effective bead operations. Dilution-based washing of magnetic beads was demonstrated by immobilizing the magnetic beads using a permanent magnet and splitting the excess supernatant using electrowetting. Almost 100% bead retention was achieved after 7776-fold dilution-based washing of the supernatant. Efficient resuspension of magnetic beads was achieved by transporting a droplet with magnetic beads across five electrodes on the platform and exploiting the flow patterns within the droplet to resuspend the beads. All the magnetic-bead droplet operations were integrated together to generate standard curves for sandwich heterogeneous immunoassays on human insulin and interleukin-6 (IL-6) with a total time to result of 7 min for each assay.


Asunto(s)
Inmunoensayo , Magnetismo , Microfluídica/instrumentación , Microfluídica/métodos , Humanos , Inmunoensayo/métodos , Insulina/química , Interleucina-6/química , Magnetismo/instrumentación
11.
Biomicrofluidics ; 9(3): 034104, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26045729

RESUMEN

The operation of digital microfluidic devices with water droplets manipulated by electrowetting is critically dependent on the static and dynamic stability and lubrication properties of the oil films that separate the droplets from the solid surfaces. The factors determining the stability of the films and preventing surface fouling in such systems are not yet thoroughly understood and were experimentally investigated in this study. The experiments were performed using a standard digital microfluidic cartridge in which water droplets enclosed in a thin, oil-filled gap were transported over an array of electrodes. Stable, continuous oil films separated the droplets from the surfaces when the droplets were stationary. During droplet transport, capillary waves formed in the films on the electrode surfaces as the oil menisci receded. The waves evolved into dome-shaped oil lenses. Droplet deformation and oil displacement caused the films at the surface opposite the electrode array to transform into dimples of oil trapped over the centers of the droplets. Lower actuation voltages were associated with slower film thinning and formation of fewer, but larger, oil lenses. Lower ac frequencies induced oscillations in the droplets that caused the films to rupture. Films were also destabilized by addition of surfactants to the oil or droplet phases. Such a comprehensive understanding of the oil film behavior will enable more robust electrowetting-actuated lab-on-a-chip devices through prevention of loss of species from droplets and contamination of surfaces at points where films may break.

12.
Lab Chip ; 4(4): 310-5, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15269796

RESUMEN

Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip systems, especially in a point-of-care setting. Conventional microfluidic devices are usually based on continuous-flow in microchannels, and offer little flexibility in terms of reconfigurability and scalability. Handling of real physiological samples has also been a major challenge in these devices. We present an alternative paradigm--a fully integrated and reconfigurable droplet-based "digital" microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. The microdroplets, which act as solution-phase reaction chambers, are manipulated using the electrowetting effect. Reliable and repeatable high-speed transport of microdroplets of human whole blood, serum, plasma, urine, saliva, sweat and tear, is demonstrated to establish the basic compatibility of these physiological fluids with the electrowetting platform. We further performed a colorimetric enzymatic glucose assay on serum, plasma, urine, and saliva, to show the feasibility of performing bioassays on real samples in our system. The concentrations obtained compare well with those obtained using a reference method, except for urine, where there is a significant difference due to interference by uric acid. A lab-on-a-chip architecture, integrating previously developed digital microfluidic components, is proposed for integrated and automated analysis of multiple analytes on a monolithic device. The lab-on-a-chip integrates sample injection, on-chip reservoirs, droplet formation structures, fluidic pathways, mixing areas and optical detection sites, on the same substrate. The pipelined operation of two glucose assays is shown on a prototype digital microfluidic lab-on-chip, as a proof-of-concept.


Asunto(s)
Líquidos Corporales/química , Pruebas de Química Clínica/instrumentación , Microfluídica , Glucosa/análisis , Humanos , Microquímica/instrumentación , Microquímica/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Humectabilidad
13.
Lab Chip ; 3(4): 253-9, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15007455

RESUMEN

The mixing of analytes and reagents for a biological or chemical lab-on-a-chip is an important, yet difficult, microfluidic operation. As volumes approach the sub-nanoliter regime, the mixing of liquids is hindered by laminar flow conditions. An electrowetting-based linear-array droplet mixer has previously been reported. However, fixed geometric parameters and the presence of flow reversibility have prevented even faster droplet mixing times. In this paper, we study the effects of varying droplet aspect ratios (height:diameter) on linear-array droplet mixers, and propose mixing strategies applicable for both high and low aspect ratio systems. An optimal aspect ratio for four electrode linear-array mixing was found to be 0.4, with a mixing time of 4.6 seconds. Mixing times were further reduced at this ratio to less than three seconds using a two-dimensional array mixer, which eliminates the effects of flow reversibility. For lower aspect ratio (

14.
Lab Chip ; 3(1): 28-33, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15100802

RESUMEN

Mixing of analytes and reagents is a critical step in realizing a lab-on-a-chip. However, mixing of liquids is very difficult in continuous flow microfluidics due to laminar flow conditions. An alternative mixing strategy is presented based on the discretization of liquids into droplets and further manipulation of those droplets by electrowetting. The interfacial tensions of the droplets are controlled with the application of voltage. The droplets act as virtual mixing chambers, and mixing occurs by transporting the droplet across an electrode array. We also present an improved method for visualization of mixing where the top and side views of mixing are simultaneously observed. Microliters of liquid droplets are mixed in less than five seconds, which is an order of magnitude improvement in reported mixing times of droplets. Flow reversibility hinders the process of mixing during linear droplet motion. This mixing process is not physically confined and can be dynamically reconfigured to any location on the chip to improve the throughput of the lab-on-a-chip.


Asunto(s)
Microquímica , Microfluídica , Electroquímica/instrumentación , Electrodos , Diseño de Equipo , Indicadores y Reactivos/química , Microquímica/instrumentación , Microquímica/métodos , Microfluídica/instrumentación , Microfluídica/métodos , Tensión Superficial , Humectabilidad
15.
Clin Chim Acta ; 424: 12-8, 2013 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-23660237

RESUMEN

PURPOSE: New therapies for lysosomal storage diseases (LSDs) have generated interest in screening newborns for these conditions. We present performance validation data on a digital microfluidic platform that performs multiplex enzymatic assays for Pompe, Fabry, Hunter, Gaucher, and Hurler diseases. METHODS: We developed an investigational disposable digital microfluidic cartridge that uses a single dried blood spot (DBS) punch for performing a 5-plex fluorometric enzymatic assay on up to 44 DBS samples. Precision and linearity of the assays were determined by analyzing quality control DBS samples; clinical performance was determined by analyzing 600 presumed normal and known affected samples (12 for Pompe, 7 for Fabry and 10 each for Hunter, Gaucher and Hurler). RESULTS: Overall coefficient of variation (CV) values between cartridges, days, instruments, and operators ranged from 2 to 21%; linearity correlation coefficients were ≥0.98 for all assays. The multiplex enzymatic assay performed from a single DBS punch was able to discriminate presumed normal from known affected samples for 5 LSDs. CONCLUSIONS: Digital microfluidic technology shows potential for rapid, high-throughput screening for 5 LSDs in a newborn screening laboratory environment. Sample preparation to enzymatic activity on each cartridge is less than 3h.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento/métodos , Enfermedades por Almacenamiento Lisosomal/diagnóstico , Microfluídica/métodos , Tamizaje Neonatal , alfa-Glucosidasas/sangre , Pruebas con Sangre Seca , Pruebas de Enzimas , Ensayos Analíticos de Alto Rendimiento/instrumentación , Ensayos Analíticos de Alto Rendimiento/normas , Humanos , Recién Nacido , Enfermedades por Almacenamiento Lisosomal/sangre , Enfermedades por Almacenamiento Lisosomal/clasificación , Microfluídica/instrumentación , Microfluídica/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , alfa-Glucosidasas/deficiencia
16.
Clin Biochem ; 46(18): 1889-91, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24036022

RESUMEN

OBJECTIVE: Newborn screening for biotinidase deficiency can be performed using a fluorometric enzyme assay on dried blood spot specimens. As a pre-requisite to the consolidation of different enzymatic assays onto a single platform, we describe here a novel analytical method for detecting biotinidase deficiency using the same digital microfluidic cartridge that has already been demonstrated to screen for five lysosomal storage diseases (Pompe, Fabry, Gaucher, Hurler and Hunter) in a multiplex format. METHODS: A novel assay to quantify biotinidase concentration in dried blood spots (DBS) was developed and optimized on the digital microfluidic platform using proficiency testing samples from the Centers for Disease Control and Prevention. The enzymatic assay uses 4-methylumbelliferyl biotin as the fluorogenic substrate. Biotinidase deficiency assays were performed on normal (n=200) and deficient (n=7) newborn DBS specimens. RESULTS: Enzymatic activity analysis of biotinidase deficiency revealed distinct separation between normal and affected DBS specimens using digital microfluidics and these results matched the expected activity. CONCLUSIONS: This study has demonstrated performance of biotinidase deficiency assays by measurement of 4-methylumbelliferyl product on a digital microfluidic platform. Due to the inherent ease in multiplexing on such a platform, consolidation of other fluorometric assays onto a single cartridge may be realized.


Asunto(s)
Deficiencia de Biotinidasa/sangre , Pruebas de Enzimas/métodos , Microfluídica/métodos , Tamizaje Neonatal/métodos , Biotina/análogos & derivados , Biotina/metabolismo , Deficiencia de Biotinidasa/diagnóstico , Pruebas con Sangre Seca , Pruebas de Enzimas/instrumentación , Fluorometría , Humanos , Recién Nacido , Umbeliferonas/metabolismo
17.
Blood Coagul Fibrinolysis ; 23(8): 760-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22964771

RESUMEN

Current methods for hypercoagulability panel testing require large blood volumes and long turn-around testing times. A novel microfluidic platform has been designed to perform automated multiplexed hypercoagulability panel testing at near patient, utilizing only a single droplet of blood sample. We test the hypothesis that this novel platform could be utilized to perform specific multiplexed ELISA-based hypercoagulability panel testing for antithrombin III, protein C, protein S and factor VIII antigens, as well as anticardiolipin/human anti-ß2-glycoprotein-1 IgG antibodies--on blood samples. Sandwich ELISA was modified by utilizing magnetic beads coated with specific antibodies as the solid phase using fluorescence readout. Percentage recovery was calculated using four-parameter logistic curves. On-chip ELISA with single factors was compared with multiplex factor ELISA for known concentrations of sample. Blood samples were analyzed on-chip and compared with traditional bench-top assays. Time for multiplexed performance of hypercoagulability panel ELISA on-chip with controls is 72 min. Recovery rates (range 80-120%) for known concentrations of specific factors was not significantly different when assays were performed using a single factor vs. multiplex factor analysis. Assay results were not significantly different between individual assays performed either on bench-top or on-chip with patient blood and/or plasma. Utilizing a novel digital microfluidic platform, we demonstrate the feasibility of automated hypercoagulability panel testing on small volume of plasma and whole blood patient samples with high fidelity. Further investigation is required to test the application of this novel technology at point-of-care clinical settings.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Trombofilia/sangre , Trombofilia/diagnóstico , Anticuerpos Anticardiolipina/sangre , Antitrombina III/análisis , Automatización de Laboratorios , Calibración , Ensayo de Inmunoadsorción Enzimática/métodos , Factor VIII/análisis , Humanos , Inmunoglobulina G/sangre , Técnicas Analíticas Microfluídicas/métodos , Proteína C/análisis , Proteína S/análisis , Reproducibilidad de los Resultados , beta 2 Glicoproteína I/sangre , beta 2 Glicoproteína I/inmunología
18.
Expert Rev Mol Diagn ; 11(4): 393-407, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21545257

RESUMEN

Digital microfluidics based on electrowetting is a type of microfluidic platform in which liquids are processed as individual unit-sized droplets that are dispensed from a source, merged together, split apart or transported between locations on demand. These devices are implemented using arrays of surface electrodes to control the shape and position of droplets through the electrowetting effect. A major thrust of digital microfluidics research has been the development of integrated lab-on-a-chip devices to perform clinical in vitro diagnostic assays. A variety of preparatory and analytical processes have been implemented and feasibility has been demonstrated for test types ranging from clinical chemistries to immunoassays, nucleic acid tests and cell-based assays. In this article, the current state and future potential of digital microfluidics for clinical diagnostic testing is reviewed and evaluated.


Asunto(s)
Técnicas de Laboratorio Clínico , Electrohumectación , Técnicas Analíticas Microfluídicas , Humanos , Manejo de Especímenes/métodos
19.
Diagn Microbiol Infect Dis ; 67(1): 22-9, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20227222

RESUMEN

Rapid, accurate diagnosis of community-acquired pneumonia (CAP) due to Mycoplasma pneumoniae is compromised by low sensitivity of culture and serology. Polymerase chain reaction (PCR) has emerged as a sensitive method to detect M. pneumoniae DNA in clinical specimens. However, conventional real-time PCR is not cost-effective for routine or outpatient implementation. Here, we evaluate a novel microfluidic real-time PCR platform (Advanced Liquid Logic, Research Triangle Park, NC) that is rapid, portable, and fully automated. We enrolled patients with CAP and extracted DNA from nasopharyngeal wash (NPW) specimens using a biotinylated capture probe and streptavidin-coupled magnetic beads. Each extract was tested for M. pneumoniae-specific DNA by real-time PCR on both conventional and microfluidic platforms using Taqman probe and primers. Three of 59 (5.0%) NPWs were positive, and agreement between the methods was 98%. The microfluidic platform was equally sensitive but 3 times faster and offers an inexpensive and convenient diagnostic test for microbial DNA.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Mycoplasma pneumoniae/aislamiento & purificación , Neumonía por Mycoplasma/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Automatización , Infecciones Comunitarias Adquiridas/microbiología , Humanos , Mycoplasma pneumoniae/genética , Nasofaringe/microbiología , Neumonía por Mycoplasma/microbiología , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Factores de Tiempo