Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Vascular ; 30(2): 267-275, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33881379

RESUMEN

OBJECTIVE: Acute limb ischaemia is still considered a significant event, with considerable early- and long-term amputation and mortality risk. Our study aims to investigate the predictive role of pre-operative neutrophil/lymphocyte and platelet/lymphocyte ratios in terms of mortality and amputation risk in patients with acute limb ischaemia. METHODS: Pre-operative blood samples of all patients admitted with acute limb ischaemia were used to calculate neutrophil/lymphocyte and platelet/lymphocyte ratios. Population was subdivided into quartiles by platelet/lymphocyte ratio and neutrophil/lymphocyte ratio values, and Kaplan-Meier life tables were obtained for overall survival and limb salvage. The optimal neutrophil/lymphocyte ratio and platelet/lymphocyte ratio cut-offs were obtained from receiver operating characteristic curves with all-cause mortality and all kinds of amputation. Stepwise multivariate analysis was performed in order to identify independent risk and protective factors for mortality and amputations. RESULTS: A total of 168 patients were included in the analysis. Receiver operating characteristic curves identified cut-off values for neutrophil/lymphocyte ratio and platelet/lymphocyte ratio: neutrophil/lymphocyte ratio ≥5.57 for mortality; neutrophil/lymphocyte ratio ≥6.66 and platelet/lymphocyte ratio ≥269.9 for all amputations. Kaplan-Meier analysis revealed that survival rate in group neutrophil/lymphocyte ratio <5.57 was 83.4%, 78.9%, 73.7%, and 59.8%, respectively, at 12, 24, 36, and 48 months; in neutrophil/lymphocyte ratio ≥5.57 group was 62.4%, 51.3%, 47.8, and 43.7%, respectively (p < 0.0001). Freedom from all amputations was significantly higher in case of neutrophil/lymphocyte ratio and platelet/lymphocyte ratio below the identified cut-off values (p < 0.0001). Neutrophil/lymphocyte ratio and platelet/lymphocyte ratio were found as independent risk factors. CONCLUSION: Neutrophil/lymphocyte ratio and platelet/lymphocyte ratio are reliable markers for stratification of mortality and limb amputations in patients with acute limb ischaemia. The inexpensive nature and ready availability of these biomarkers' values reinforced their usefulness in everyday clinical practice.


Asunto(s)
Linfocitos , Neutrófilos , Amputación Quirúrgica/efectos adversos , Humanos , Isquemia/diagnóstico , Isquemia/cirugía , Recuento de Linfocitos , Estudios Retrospectivos
2.
Neurol Sci ; 42(11): 4737-4739, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34218326

RESUMEN

INTODUCTION: Familial cerebral cavernous malformations (FCCM) are a rare condition characterized by the multiple presences of cavernous malformations located in the central nervous system. CASE DESCRIPTION: We present a case of FCCM incidental diagnosis in a 71-year-old male patient who underwent carotid artery stenting for high-grade carotid artery disease and subsequent reintervention for severe stent restenosis, determining neurological deficit. FCCM diagnosis was made due to the presence of hundreds of cavernous malformations located both in supra- and sub-tentorial regions highlighted by magnetic resonance and confirmed by genetic test for the mutation of the gene KRIT1, inherited also by his son.


Asunto(s)
Hemangioma Cavernoso del Sistema Nervioso Central , Proteínas Asociadas a Microtúbulos , Anciano , Arterias Carótidas , Hemangioma Cavernoso del Sistema Nervioso Central/diagnóstico por imagen , Hemangioma Cavernoso del Sistema Nervioso Central/genética , Hemangioma Cavernoso del Sistema Nervioso Central/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Proteínas Asociadas a Microtúbulos/genética , Linaje , Proteínas Proto-Oncogénicas/genética
3.
Ann Vasc Surg ; 75: 523-526, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33915253

RESUMEN

INTRODUCTION: Device fracture causing intravascular foreign body (IFB) is a rare event during endovascular procedures, with potential catastrophic outcome if not promptly removed. We present two cases of retrieval of fractured devices during peripheral lower limb procedures using three guidewires tangled around the IFB. TECHNIQUES: Case 1 was a patient with critical limb ischemia. During balloon angioplasty of a high calcified peroneal artery, the balloon catheter Amphirion Deep 2.5/150 mm (Medtronic) fractured in two pieces, leaving a 20 cm distal part into the artery. Three 0.014" guides were advanced distally the IFB and twisted all together using a single torque-device. It was possible to pull back the long balloon fragment into the popliteal and to reline it inside a 5 French sheath. Case 2 was a patient with acute limb ischemia. During the mechanical thrombo-aspiration using the Indigo System (Penumbra inc.), the distal wire of the olive-shaped separator cracked in the posterior tibial artery. By crossing the IFB with three 0.014" wires and twisting them around it, this 15mm fragment was successfully recaptured. CONCLUSIONS: We named this procedure Triple Wire Twisting Technique and, in our experience, this technique is safe and effective to recapture IFB during complex peripheral procedures. This poorly known rescue technique is not complex and requires materials that are available in all cath-lab. We truly believe that physicians can take advantage of knowing it when facing with IFB in any vessel.


Asunto(s)
Angioplastia de Balón/instrumentación , Remoción de Dispositivos/métodos , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Trombectomía/instrumentación , Dispositivos de Acceso Vascular , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Enfermedad Crítica , Falla de Equipo , Humanos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Trombectomía/efectos adversos , Resultado del Tratamiento
4.
Ann Vasc Surg ; 71: 112-120, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32768532

RESUMEN

BACKGROUND: Cranial and cervical nerve (CCN) injury is recognized as a possible complication after carotid endarterectomy (CEA), which may result in minor local neurologic deficiencies and significant discomfort for the patient. The aim of this study is to investigate the effect of a mini-skin incision (<5 cm) on the CCN injury after CEA in comparison to standard longitudinal incision of 12-15 cm in a high volume center, and to evaluate health-related quality of life (HRQOL) outcomes in those patients who had undergone both types of the skin incision. METHODS: From January 2013 to December 2019, 446 CEAs (47.3%) were performed through a standard neck incision of 12-15 cm (group A), while 496 (52.7%) were performed through a mini-skin incision (<5 cm) (group B). Sixty-two patients underwent standard neck incision on one side and mini-skin incision on the other side (subgroup B). The main outcome measures were stroke, death, CCN injuries, cervical hematoma rates, and reinterventions. The HRQOL was assessed at baseline and after 30 days using Medical Outcomes Study Short-Form 36 and 6 disease-specific modified Likert scales. RESULTS: The stroke and death rate at 30 days was 1.12% in group A and 1% in group B (P = 1). The incidence of CCN deficits was significantly lower in group B (5.1%) in comparison to group A (13.4%) (P < 0.001). The cervical hematoma was more common after standard incision (4.9% vs. 1.2%, P = 0.02). HRQOL at 1 month showed that the outcomes after mini-skin incision were significantly better for less difficulty with eating/swallowing and neck pain (P < 0.01). CONCLUSIONS: CEA through a small incision (<5 cm) may reduce CCN complications without additional perioperative neurologic risks. As validated by patients with bilateral disease who experienced both surgical techniques, mini-skin incision is also associated with better HRQOL at 1 month, particularly with regard to eating/swallowing and neck pain.


Asunto(s)
Enfermedades de las Arterias Carótidas/cirugía , Traumatismos del Nervio Craneal/prevención & control , Procedimientos Quirúrgicos Dermatologicos , Endarterectomía Carotidea , Calidad de Vida , Anciano , Anciano de 80 o más Años , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/mortalidad , Traumatismos del Nervio Craneal/etiología , Traumatismos del Nervio Craneal/fisiopatología , Deglución , Procedimientos Quirúrgicos Dermatologicos/efectos adversos , Procedimientos Quirúrgicos Dermatologicos/mortalidad , Ingestión de Alimentos , Endarterectomía Carotidea/efectos adversos , Endarterectomía Carotidea/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor de Cuello/etiología , Dolor de Cuello/fisiopatología , Dolor de Cuello/prevención & control , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
Vascular ; 29(1): 27-34, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32611281

RESUMEN

OBJECTIVE: In the last decades, life expectancy has increased worldwide considerably. Traditionally, very elderly patients have been considered too frail to undergo major vascular interventions. Considering that abdominal aortic aneurysm is an age-related disease, there is an increasing need of a correct management of the disease even in nonagenarians, but data are still scarce. The purpose of this single-centre study is to report early and mid-term outcomes of all-comer abdominal aortic aneurysm patients in their 10th decades of age. METHODS: A retrospective review of our prospectively maintained database identified a total of 33 patients aged ≥ 90 presenting with abdominal aortic aneurysm between 2014 and 2019. Elective and emergency repairs were both considered. Early technical success and mortality rate at 30 days were considered as primary outcomes. Mid-term clinical success was reported, and overall survival, freedom from aneurysm-related death, re-interventions and endoleaks were estimated with the Kaplan-Meier method, stratified for elective of emergency repair and type of treatment. RESULTS: The mean age was 91.7 (range 90-96), and 63.6% were male. Mean abdominal aortic aneurysm diameter was 67.4 ± 16.8 mm. Sixteen patients were admitted for rupture abdominal aortic aneurysm: three untreated, five underwent open and seven underwent endovascular aneurysm repair (EVAR), with an early mortality rate of 100, 100 and 42.8%, respectively. Eighteen (60%) patients were asymptomatic, and all underwent elective EVAR, with an early mortality rate of 0%. At one-month follow-up, clinical success was 84% in EVAR group. At a median follow-up of 22.4 ± 14.5 months, no abdominal aortic aneurysm-related death was registered. Freedom from all cause of mortality was 77.3, 59.4 and 40.7% at one, two and three years. Freedom from endoleaks was 95.4% at one month and 61.7% at one and three years. Freedom from reintervention was 85.8% at three years. CONCLUSION: Elective EVAR in nonagenarians is associated with acceptable early and mid-term outcomes. Age by itself should not be considered an exclusion criterion for treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Factores de Edad , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Toma de Decisiones Clínicas , Bases de Datos Factuales , Procedimientos Quirúrgicos Electivos , Urgencias Médicas , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Italia , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
6.
J Vasc Surg ; 71(6): 1843-1850, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31676183

RESUMEN

OBJECTIVE: In cases of juxtarenal abdominal aortic aneurysm (jAAA), endovascular aneurysm repair (EVAR) involves the use of custom-made fenestrated stent grafts, which usually need large-diameter access vessels, superior costs, and a certain time between graft planning and delivery. We report our preliminary experience using the bare renal stent technique (called vent) in combination with the ultralow-profile stent graft Ovation (Endologix, Irvine, Calif) to seal jAAAs in patients evaluated to be unfit for open surgery and not suitable for fenestrated endograft. METHODS: A single-center retrospective review of jAAAs treated by Ovation vent technique from January 2015 to December 2018 was conduced. The vent procedure consisted of a modified, off-label deployment of the sealing ring of the ultralow-profile Ovation stent graft close to renal orifices in combination with short bare-metal stents. The exclusion criterion was a diameter >31 mm at the level of the lowest renal artery. Early technical and clinical results, estimated midterm survival, renal artery patency, freedom from type IA endoleak, freedom from reintervention, and freedom from neck enlargement (>2 mm) were reported. RESULTS: Overall, 38 patients had jAAA and were considered unfit for open repair and not eligible for fenestrated EVAR. The proximal neck was <5 mm in all cases (mean, 3.3 ± 1.2 mm). Vent renal stents were implanted bilaterally in 16 patients. Primary technical success was 94.7% (36/38), with satisfactory cannulation of all renal arteries and sealing of the aneurysm in all but two cases because of type IA endoleaks that were treated immediately with success. Primary clinical success at 1 month was 100%. During a median follow-up period of 22.4 ± 3.6 months (range, 1-46 months), no abdominal aortic aneurysm-related deaths occurred, and no patient was lost to follow-up. The survival curve at 1 year and 2 years was, respectively, 96.4% and 91.6% (standard error, 0.57%). There were no cases of neck dilation or endograft migration. Freedom from reintervention at 12 months and 24 months was 100% and 89.5%, respectively (standard error, 0.7%); freedom from type IA endoleak was 100% and patency of the renal artery was 100% at 2 years. CONCLUSIONS: The described technique includes the use of a low-profile stent graft with a polymer ring sealing technology combined with bare renal stents that are not competing for the same room. This early experience shows that the vent technique is safe and feasible and increases the range of treatment of those patients with jAAA who are unfit for open repair and for fenestrated EVAR because of several anatomic constraints.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
J Clin Med ; 12(9)2023 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-37176513

RESUMEN

This paper offers a practical overview of the contemporary management of patients with peripheral arterial disease presenting intermittent claudication (IC), including clinical and instrumental diagnosis, risk factors modification, medical management, and evidence-based revascularization indications and techniques. Decision making represents a crucial element in the management of the patient with IC; for this, we think a review of this type could be very useful, especially for non-vascular specialists.

8.
EJVES Vasc Forum ; 54: 7-12, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34950916

RESUMEN

INTRODUCTION: Since 2010, the Ovation Abdominal Stent Graft System has offered a new sealing concept, achieved by a sealing ring filled with polymer 13 mm from the renal arteries. In the latest version, called Ovation Alto, the sealing ring is relocated 6 mm closer to the top of the fabric. This study describes the early clinical outcomes, after CE Mark approval in August 2020, of endovascular aneurysm repair with the Alto endograft. REPORT: Eleven patients underwent endovascular aneurysm repair with implantation of Ovation Alto endografts. All patients were male, and the median age was 75 (IQR 5.5) years. Hostile proximal aortic neck (<10 mm) was identified in six cases (54.5%). All procedures were performed using bilateral percutaneous approaches with no groin complications. The median procedure time was 58 (IQR 7.2) minutes, the median contrast volume used was 65 (IQR 4.2) mL, and the median blood loss 40 (IQR 12.4) mL. Technical success was achieved in all cases. The median stent graft landing distance between the top of the fabric and the lowest renal artery was 1.4 (IQR 0.8) mm. No intra-operative high flow endoleaks were registered. At one and six month follow up, there was 100% clinical success (no type I/III endoleak, sac enlargement, stent graft migration, polymer leakage, abdominal aortic aneurysm related mortality, or secondary intervention). DISCUSSION: Initial experience confirms the early technical and clinical success of the new Ovation Alto stent graft. Technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on label. Further studies are needed to evaluate long term durability outcomes.

9.
Polymers (Basel) ; 13(8)2021 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-33917214

RESUMEN

An abdominal aortic aneurysm (AAA) is a dilatation of the abdominal aorta that progressively grows until it ruptures. Treatment is typically recommended when the diameter is more than 5 cm. The EVAR (Endovascular aneurysm repair) is a minimally invasive procedure that involves the placement of an expandable stent graft within the aorta to treat aortic disease without operating directly on the aorta. For years, stent grafts' essential design was based on metallic stent frames to support the fabric. More recently, a polymer-based technology has been proposed as an alternative method to seal AAA. This review underlines the two platforms that are based on a polymer technology: (1) the polymer-filled endobags, also known as Endovascular Aneurysm Sealing (EVAS) with Nellix stent graft; and (2) the O-ring EVAR polymer-based proximal neck sealing device, also known as an Ovation stent graft. Polymer characteristics for this particular aim, clinical applications, and durability results are hereby summarized and commented critically. The technique of inflating endobags filled with polymer to exclude the aneurysmal sac was not successful due to the lack of an adequate proximal fixation. The platform that used polymer to create a circumferential sealing of the aneurysmal neck has proven safe and effective.

10.
Front Surg ; 8: 646204, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33763447

RESUMEN

Background: The role of carotid revascularization in women remains intensely debated because of the lower benefit and higher perioperative risks concerning the male counterpart. Carotid artery endarterectomy (CEA) and stenting (CAS) represent the two most valuable stroke prevention techniques due to large vessel disease. This study investigates the early and late outcomes in female sex in a real-world everyday clinical practice. Methods: Data were retrospectively analyzed from a single-center database prospectively compiled. A total of 234 procedures, both symptomatic and asymptomatic, were identified (98 CEAs and 136 CASs). Perioperative risks of death, cerebral ischemic events, and local complications were analyzed and compared between the two groups. Long-term outcomes were evaluated in overall survival, freedom from ipsilateral stroke/transient ischemic attack, and freedom from restenosis (>50%) and reintervention. Results: Women who underwent CAS and CEA did not differ in perioperative ischemic cerebral events (2.2 vs. 0%, p = 0.26) and death (0.8 vs. 0%, p = 1). Other perioperative and 30-day outcomes were similarly distributed within the two groups. Kaplan-Meier curves between CAS and CEA groups highlighted no statistical differences at 6 years in overall survival (77.4 vs. 77.1%, p = 0.47) of ipsilateral stroke/transient ischemic attack (94.1 vs. 92.9%, p = 0.9). Conversely, significant differences were showed in 6 years freedom from restenosis (93.1 vs. 83.3%, p = 0.03) and reinterventions (97.7 vs. 87.8%, p = 0.015). Conclusion: Our results revealed that both CEA and CAS have acceptable perioperative risk in women. Long-term outcomes highlighted favorable indications for both procedures, especially for CAS, which seemed to be an excellent alternative to CEA in female patients when performed by well-trained operators.

11.
Angiology ; 72(5): 480-489, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33406850

RESUMEN

We evaluated the outcomes of revascularization in patients with chronic limb-threatening ischemia (CLTI) treated in real-world settings. This is a prospective multicenter cohort study with 12-month follow-up enrolling patients (n = 287) with CLTI undergoing open, endovascular, or hybrid lower extremity revascularization. The primary end point was amputation-free survival (AFS) at 12 months. Cox proportional analysis was used to determine independent predictors of amputation and restenosis. At 30 days, major adverse cardiovascular and major adverse limb events (MALE) rates were 3.1% and 2.1%, respectively. At 1 year, the overall survival rate was 88.8%, the AFS was 86.6%, and the primary patency was 70.5%. Freedom from MALE was 62.5%. After multivariate analysis, smoking (hazard ratio [HR] = 2.2, P = 0.04), renal failure (HR = 2.3, P = 0.03), Rutherford class (≥5) (HR = 3.2, P = 0.01), and below-the-knee disease (HR = 2.0, P = 0.05) were significant predictors of amputation; iloprost infusion (>10 vials) (HR = 0.64, P = 0.05) was a significant protective factor. Cilostazol administration (HR = 0.77, P = 0.05) was a significant protective factor for restenosis. Results from this prospective multicenter registry offer a consistent overview of clinical outcomes of CLTI patients at 1 year when adequately revascularized. Medical treatment, including statins, cilostazol and iloprost, were associated with improved 1-year freedom from restenosis and amputation.


Asunto(s)
Procedimientos Endovasculares , Isquemia/cirugía , Enfermedad Arterial Periférica/cirugía , Procedimientos Quirúrgicos Vasculares , Anciano , Amputación Quirúrgica , Fármacos Cardiovasculares/uso terapéutico , Enfermedad Crónica , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Isquemia/diagnóstico por imagen , Isquemia/mortalidad , Italia , Recuperación del Miembro , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/mortalidad , Estudios Prospectivos , Recurrencia , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
12.
Expert Rev Cardiovasc Ther ; 18(4): 219-229, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32294392

RESUMEN

Introduction: Optical Coherence Tomography (OCT) is an intravascular imaging providing high-resolution images of morphological features of arterial wall. Nowadays, OCT is an accepted intravascular modality to study coronary arteries, stent implantation, and vessel injury. In the last decade, an increasing interest have been focused on the application of OCT in carotid arteries.Areas covered: Literature evidence in the application of OCT in carotid arteries still remains debated. So far, OCT has been used as a research tool, aiming to evaluate atherosclerotic plaques' features and stents' behavior after implantation. This paper is intended to summarize clinical evidences and practices in the use of OCT in carotid arteries district and during CAS procedures. Literature review was completed via Pubmed search using Keywords.Expert opinion: CAS is a safe and effective procedure when performed by trained physicians with a tailored approach. In this scenario, ambiguous pictures at ultrasound, angiography, and IVUS might be clarified using OCT.By providing unprecedented microstructural information on atherosclerotic plaques, OCT may identify the features of vulnerable carotid plaque and, by identifying possible defects after stent implantation as malapposition and plaque prolapse, it may help the tailoring approach to CAS.


Asunto(s)
Arterias Carótidas/diagnóstico por imagen , Stents , Tomografía de Coherencia Óptica , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA