Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Circulation ; 105(17): 2037-42, 2002 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-11980682

RESUMEN

BACKGROUND: Intramural hematomas during percutaneous coronary intervention (PCI) have not been well studied. METHODS AND RESULTS: We used intravascular ultrasound to determine the incidence, morphology, and clinical features of post-PCI intramural hematomas. In 905 patients with 1025 consecutive native coronary artery, non-in-stent restenosis lesions undergoing PCI, 72 hematomas were detected in 69 arteries in 68 patients. The incidence of intramural hematomas per artery was 6.7% (69 of 1025); 36% (26 of 72) involved the proximal reference artery, 18% (13 of 72) were confined to the lesion, and 46% (33 of 72) involved the distal reference artery. The entry site from the lumen into the hematoma was identified in 86% of hematomas (62 of 72) and had the appearance of a dissection into the media. Conversely, a re-entry site was identifiable in only 8% (6 of 72). The axial extension of the hematoma was distal in 63% and proximal in 37%. In 60% of the hematomas (42 of 72) the angiogram had the appearance of a dissection; in 11% (8 of 72), it appeared to be a new stenosis; and in 29% (22 of 72), no significant abnormality was detected. Non-Q-wave myocardial infarctions occurred in 26% of patients (17 of 65). In 3 patients, the creatine kinase-MB was not measured during the hospital stay. Repeat revascularization occurred in 2 patients in-hospital, 2 additional patients at 1 month, and 8 additional patients at 1 year. There were 3 sudden deaths at 1 year. CONCLUSIONS: Intravascular ultrasound identified intramural hematomas after 6.7% of PCIs. The mechanism appeared to be a dissection into the media where blood accumulated because of a lack of re-entry. A third of ultrasound-identified hematomas showed no angiographic abnormalities. There was a high rate of non-Q-wave myocardial infarction, need for repeat revascularization, and sudden death in patients with hematomas.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/etiología , Hematoma/diagnóstico por imagen , Hematoma/etiología , Angiografía Coronaria , Enfermedad Coronaria/epidemiología , Reestenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Femenino , Hematoma/epidemiología , Humanos , Incidencia , Masculino , Resultado del Tratamiento , Ultrasonografía
2.
J Am Coll Cardiol ; 44(7): 1386-92, 2004 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-15464317

RESUMEN

OBJECTIVES: The aim of this study was to establish safety and feasibility of oral Rapamycin at two doses-2 mg and 5 mg-in achieving low rates of repeat target lesion revascularization (TLR) in de novo native coronary artery lesions. BACKGROUND: Drug-eluting stents have shown the ability to limit restenosis. Oral Rapamycin is an alternative strategy that can target multiple coronary lesions suitable for treatment with any approved metal stent and at potentially lower cost. METHODS: The Oral Rapamune to Inhibit Restenosis (ORBIT) study is an open-label study of 60 patients with de novo lesions treated with bare metal stents in up to two vessels. After a loading dose of 5 mg, patients received a daily dose of 2 mg (n = 30) and 5 mg (n = 30) for 30 days. Six-month angiographic, intravascular ultrasound (IVUS), and clinical follow-up were conducted. RESULTS: Baseline clinical and procedural characteristics were similar: 10% of patients in the 2-mg group and 30% in the 5-mg group did not complete the course; 43% in the 2-mg group and 66% in the 5-mg group had side effects. At six-month follow-up, late loss (0.6 +/- 0.5 mm vs. 0.7 +/- 0.5 mm; p = NS), in-stent binary restenosis (7.1% vs. 6.9%; p = NS), in-stent percent volume obstruction by IVUS (29% vs. 24%; p = NS), and clinically driven TLR (14.3% vs. 6.9%; p = NS) were similar in 2-mg and 5-mg groups. CONCLUSIONS: Oral Rapamycin for the prevention of restenosis is safe, feasible, and associated with low rates of repeat revascularization. Although associated with certain side effects, it may be considered for patients undergoing multivessel stents if proven in larger randomized studies.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/prevención & control , Sirolimus/uso terapéutico , Stents/efectos adversos , Administración Oral , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Esquema de Medicación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional
5.
Cardiovasc Radiat Med ; 3(1): 56-9, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12479917

RESUMEN

BACKGROUND: The effects of overlapping beta-emitter sources on the treatment of in-stent restenosis (ISR) lesions as a result of manual stepping are unknown. METHODS AND RESULTS: In the BETA WRIST (Beta Washington Radiation for In-stent Restenosis Trial), 17 out of the 50 patients who received radiation treatment had diffuse ISR in native coronaries that required manual stepping of the beta-emitter (90Y) source in order to cover the lesion and the edges. Fourteen of those patients received radiation with an overlap of up to 3 mm in the middle of the stented segment. The prescribed dose was 20.6 Gy to a distance of 1.0 mm from the surface of the inflated balloon, and the calculated dose to the vessel wall at the overlapped area did not exceed 75 Gy. There was no difference in late total occlusion (7.1% vs. 9.0%, P=NS) and target lesion revascularization (28.5% vs. 27.2%, P=NS) between patients with stepping and those without stepping. At 6 months, there was no evidence of perforation or aneurysm at the overlapped segments. Quantitative coronary angiographic (QCA) analysis revealed significantly reduced late loss in the overlapped segment compared to the adjacent segment (P=.04). Serial (postradiation vs. follow-up) IVUS measurement showed larger mean lumen cross-sectional area (CSA) (P=.0035) and smaller mean intimal hyperplasia (IH) CSA (P=.0010) in the overlapped segment compared to the adjacent segment. CONCLUSION: Manual stepping of beta-emitter source with a short overlapped segment is safe for diffuse ISR. Further increase in lumen dimension and reduction in IH formation are observed at the overlapped segment.


Asunto(s)
Partículas beta/uso terapéutico , Reestenosis Coronaria/radioterapia , Manuales como Asunto , Stents , Radioisótopos de Itrio/uso terapéutico , Adulto , Anciano , Implantación de Prótesis Vascular , Cateterismo , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Reestenosis Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA