Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Opt Lett ; 45(13): 3605-3608, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32630910

RESUMEN

Fiber-optic-based two-photon fluorescence endomicroscopy is emerging as an enabling technology for in vivo histological imaging of internal organs and functional neuronal imaging on freely-behaving animals. However, high-speed imaging remains challenging due to the expense of miniaturization and lack of suited fast beam scanners. For many applications, a higher imaging speed is highly desired, especially for monitoring functional dynamics such as transient dendritic responses in neuroscience. This Letter reports the development of a fast fiber-optic scanning endo-microscope with an imaging speed higher than 26 frames/s. In vivo neural dynamics imaging with the high-speed endomicroscope was performed on a freely-behaving mouse over the primary motor cortex that expressed GCaMP6m. The results demonstrate its capability of real-time monitoring of transient neuronal dynamics with very fine temporal resolution.


Asunto(s)
Microscopía Fluorescente/instrumentación , Neuronas/metabolismo , Fibras Ópticas , Animales , Ratones , Corteza Motora/citología , Factores de Tiempo
2.
Opt Lett ; 44(9): 2232-2235, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-31042191

RESUMEN

We report an ultralow-voltage, electrothermal (ET) micro-electro-mechanical system (MEMS) based probe for forward-viewing endoscopic optical coherence tomography (OCT) imaging. The fully assembled probe has a diameter of 5.5 mm and a length of 55 mm, including the imaging optics and a 40 mm long fiber-optic cantilever attached on a micro-platform of the bimorph ET MEMS actuator. The ET MEMS actuator provides a sufficient mechanical actuation force as well as a large vertical displacement, achieving up to a 3 mm optical scanning range with only a 3 VACp-p drive voltage with a 1.5 VDC offset. The imaging probe was integrated with a swept-source OCT system of a 100 kHz A-scan rate, and its performance was successfully demonstrated with cross-sectional imaging of biological tissues ex vivo and in vivo at a speed up to 200 frames per second.

3.
Nanotechnology ; 30(1): 015301, 2019 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-30272575

RESUMEN

Transparent conducting electrodes (TCEs) based on silver nanowire (AgNW) networks possess high conductance, transmittance, and mechanical flexibility. However, due to the relatively high diffuse reflection of incident light on AgNWs, they cannot be practically implemented in displays requiring low pattern visibility. One promising strategy for solving this problem is to place an optical stack with high refractive index underneath the AgNW layer. In this work, AgNW-RuO2 nanosheet hybrid TCEs with low diffuse reflections are fabricated using metallic RuO2 nanosheets as undercoats. As predicted by theoretical simulations, RuO2 nanosheets with high refractive indices reduce the diffuse reflections of AgNWs by almost 8%. Moreover, after the partial etching of AgNWs, the difference in the diffuse reflections of their etched and non-etched regions becomes equal to about 0.003, leading to the formation of an invisible pattern. The film consisting of micro-sized RuO2 nanosheets is not damaged during etching, but instead forms a current path between different AgNWs broken by cyclic bending, resulting in a tenfold decrease in the resistance of the AgNW TCE after 170 000 cycles. Further, RuO2 nanosheets suppress the diffusion of humid air from the outside, thus improving the environmental stability of the AgNW-RuO2 nanosheet hybrid TCEs.

4.
Opt Lett ; 42(23): 4978-4981, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29216160

RESUMEN

We report the development of a broadband rotary joint for high-speed ultrahigh-resolution endoscopic optical coherence tomography (OCT) imaging in the 800 nm spectral range. This rotary joint features a pair of achromatic doublets in order to achieve broadband operation for a 3 dB bandwidth over 150 nm. The measured one-way throughput of the rotary joint is greater than 80%, while the fluctuation of the double-pass coupling efficiency during 360 deg rotation is less than ±5% at a near video-rate speed of 20 revolutions/s (rps). The rotary joint is used in conjunction with a diffractive-optics-based endoscope and 800 nm spectral domain OCT system and achieved an ultrahigh axial resolution of ∼2.4 µm in air. The imaging performance is demonstrated by 3D circumferential imaging of a mouse colon in vivo.


Asunto(s)
Endoscopía/métodos , Rotación , Tomografía de Coherencia Óptica/métodos , Animales , Colon/diagnóstico por imagen , Endoscopía/instrumentación , Ratones , Recto/diagnóstico por imagen , Tomografía de Coherencia Óptica/instrumentación
5.
Opt Express ; 24(4): 3903-9, 2016 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-26907043

RESUMEN

We report a novel MEMS fiber scanner with an electrothermal silicon microactuator and a directly mounted optical fiber. The microactuator comprises double hot arm and cold arm structures with a linking bridge and an optical fiber is aligned along a silicon fiber groove. The unique feature induces separation of resonant scanning frequencies of a single optical fiber in lateral and vertical directions, which realizes Lissajous scanning during the resonant motion. The footprint dimension of microactuator is 1.28 x 7 x 0.44 mm3. The resonant scanning frequencies of a 20 mm long optical fiber are 239.4 Hz and 218.4 Hz in lateral and vertical directions, respectively. The full scanned area indicates 451 µm x 558 µm under a 16 Vpp pulse train. This novel laser scanner can provide many opportunities for laser scanning endomicroscopic applications.

6.
Opt Express ; 24(9): 9667-72, 2016 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-27137580

RESUMEN

This work reports electrothermal MEMS parallel plate-rotation (PPR) for a single-imager based stereoscopic endoscope. A thin optical plate was directly connected to an electrothermal MEMS microactuator with bimorph structures of thin silicon and aluminum layers. The fabricated MEMS PPR device precisely rotates an transparent optical plate up to 37° prior to an endoscopic camera and creates the binocular disparities, comparable to those from binocular cameras with a baseline distance over 100 µm. The anaglyph 3D images and disparity maps were successfully achieved by extracting the local binocular disparities from two optical images captured at the relative positions. The physical volume of MEMS PPR is well fit in 3.4 mm x 3.3 mm x 1 mm. This method provides a new direction for compact stereoscopic 3D endoscopic imaging systems.

7.
Opt Express ; 22(5): 5818-25, 2014 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-24663919

RESUMEN

We report a fully packaged and compact forward viewing endomicroscope by using a resonant fiber scanner with two dimensional Lissajous trajectories. The fiber scanner comprises a single mode fiber with additional microstructures mounted inside a piezoelectric tube with quartered electrodes. The mechanical cross-coupling between the transverse axes of a resonant fiber with a circular cross-section was completely eliminated by asymmetrically modulating the stiffness of the fiber cantilever with silicon microstructures and an off-set fiber fragment. The Lissajous fiber scanner was fully packaged as endomicroscopic catheter passing through the accessory channel of a clinical endoscope and combined with spectral domain optical coherence tomography (SD-OCT). Ex-vivo 3D OCT images were successfully reconstructed along Lissajous trajectory. The preview imaging capability of the Lissajous scanning enables rapid 3D imaging with high temporal resolution. This endoscopic catheter provides many opportunities for on-demand and non-invasive optical biopsy inside a gastrointestinal endoscope.

8.
Opt Lett ; 39(23): 6675-8, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25490650

RESUMEN

This work reports micromachined tethered silicon oscillators (MTSOs) for endoscopic Lissajous fiber scanners. An MTSO comprises an offset silicon spring for stiffness modulation of a scanning fiber and additional mass for modulation of resonant scanning frequency in one body. MTSOs were assembled with a resonant fiber scanner and enhanced scanning reliability of the scanner by eliminating mechanical cross coupling. The fiber scanner with MTSOs was fully packaged as an endomicroscopic catheter and coupled with a conventional laparoscope and spectral domain OCT system. The endomicroscope was maneuvered with the integrated laparoscope and in vivo swine tissue OCT imaging was successfully demonstrated during open surgery. This new component serves as an important element inside an endoscopic Lissajous fiber scanner for early cancer detection or on-demand minimum lesional margin decision during noninvasive endoscopic biopsy.


Asunto(s)
Endoscopía/instrumentación , Tecnología de Fibra Óptica , Microtecnología/instrumentación , Silicio , Animales , Catéteres , Intestino Delgado , Porcinos
9.
BME Front ; 5: 0041, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577399

RESUMEN

Objective and Impact Statement: A clinically viable technology for comprehensive esophagus surveillance and potential treatment is lacking. Here, we report a novel multifunctional ablative gastrointestinal imaging capsule (MAGIC) technology platform to address this clinical need. The MAGIC technology could also facilitate the clinical translation and adoption of the tethered capsule endomicroscopy (TCE) technology. Introduction: Recently developed optical coherence tomography (OCT) TCE technologies have shown a promising potential for surveillance of Barrett's esophagus and esophageal cancer in awake patients without the need for sedation. However, it remains challenging with the current TCE technology for detecting early lesions and clinical adoption due to its suboptimal resolution, imaging contrast, and lack of visual guidance during imaging. Methods: Our technology reported here integrates dual-wavelength OCT imaging (operating at 800 and 1300 nm), an ultracompact endoscope camera, and an ablation laser, aiming to enable comprehensive surveillance, guidance, and potential ablative treatment of the esophagus. Results: The MAGIC has been successfully developed with its multimodality imaging and ablation capabilities demonstrated by imaging swine esophagus ex vivo and in vivo. The 800-nm OCT imaging offers exceptional resolution and contrast for the superficial layers, well suited for detecting subtle changes associated with early neoplasia. The 1300-nm OCT imaging provides deeper penetration, essential for assessing lesion invasion. The built-in miniature camera affords a conventional endoscopic view for assisting capsule deployment and laser ablation. Conclusion: By offering complementary and clinically viable functions in a single device, the reported technology represents an effective solution for endoscopic screening, diagnosis, and potential ablation treatment of the esophagus of a patient in an office setting.

10.
Phys Chem Chem Phys ; 15(30): 12525-9, 2013 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-23775261

RESUMEN

Density functional theory calculations are used to investigate the energetics of protons crossing triple phase boundaries based on a metal catalyst, Pd or Ni, and barium zirconate. Our calculations show that the proton transfer reaction at these interfaces is controlled by the terminal layer of the electrolyte in contact with the metallic and gas phases. The hydrogen spilling process onto the electrolyte surface is energetically favored at peripheral sites of the metal-electrolyte interface, and proton incorporation into the sub-surface region of the electrolyte involves energies of the order of 1 eV. At the triple phase boundary, the energy cost associated with the proton transfer reaction is controlled by both the nature of chemical contact and the Schottky barrier at the metal-electrolyte interface.

11.
Phys Chem Chem Phys ; 15(11): 3820-6, 2013 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-23396506

RESUMEN

An asymmetric cell based on a proton conductor, BaZr(0.1)Ce(0.7)Y(0.1)Yb(0.1)O(3-δ) (BZCYYb), with a well-defined patterned Pt electrode was prepared to study the kinetics and mechanism of the hydrogen oxidation reaction under typical conditions for fuel cell operation and hydrogen separation, including operating temperature and hydrogen partial pressure. Steady-state polarization curves were carefully analyzed to determine the apparent exchange current density, limiting current density, and charge transfer coefficients. The empirical reaction order, as estimated from the dependence of electrode polarization (R(p)) and exchange current density on the partial pressure of hydrogen (P(H(2))), varied from 0.55 to 0.71. The results indicate that hydrogen dissociation contributes the most to the rate-limiting step of the hydrogen oxidation reaction taking place at the Pt-BZCYYb interface. At high current densities, surface diffusion of electroactive species appears to contribute to the rate-limiting step as well.

12.
Biomed Opt Express ; 14(1): 81-88, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36698668

RESUMEN

Real-time intraoperative delineation of cancer and non-cancer brain tissues, especially in the eloquent cortex, is critical for thorough cancer resection, lengthening survival, and improving quality of life. Prior studies have established that thresholding optical attenuation values reveals cancer regions with high sensitivity and specificity. However, threshold of a single value disregards local information important to making more robust predictions. Hence, we propose deep convolutional neural networks (CNNs) trained on labeled OCT images and co-occurrence matrix features extracted from these images to synergize attenuation characteristics and texture features. Specifically, we adapt a deep ensemble model trained on 5,831 examples in a training dataset of 7 patients. We obtain 93.31% sensitivity and 97.04% specificity on a holdout set of 4 patients without the need for beam profile normalization using a reference phantom. The segmentation maps produced by parsing the OCT volume and tiling the outputs of our model are in excellent agreement with attenuation mapping-based methods. Our new approach for this important application has considerable implications for clinical translation.

13.
Opt Lett ; 37(13): 2673-5, 2012 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-22743491

RESUMEN

This Letter reports a fully packaged microelectromechanical system (MEMS) endoscopic catheter for forward imaging optical coherence tomography (OCT). Two-dimensional optical scanning of Lissajous patterns was realized by the orthogonal movement of two commercial aspherical glass lenses laterally mounted on two resonating electrostatic MEMS microstages at low operating voltages. The MEMS lens scanner was integrated on a printed circuit board and packaged with an aluminum housing, a gradient index fiber collimator, and an objective lens. A home-built spectral-domain OCT system with 60 kHz A-line acquisition rate was combined with the endoscopic MEMS catheter. Three-dimensional images of 256×256×995 voxels were directly reconstructed by mapping the A-line datasets along the Lissajous patterns. The endoscopic catheter can provide a new direction for forward endoscopic OCT imaging.


Asunto(s)
Electricidad , Endoscopía/instrumentación , Lentes , Fenómenos Mecánicos , Microtecnología/instrumentación , Tomografía de Coherencia Óptica/instrumentación , Animales , Oído , Imagenología Tridimensional , Ratones
14.
IEEE Trans Biomed Eng ; PP2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35786546

RESUMEN

OBJECTIVE/BACKGROUND: In vivo imaging and quantification of the microstructures of small airways in three dimensions (3D) allows a better understanding and management of airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). At present, the resolution and contrast of the currently available conventional optical coherence tomography (OCT) imaging technologies operating at 1300 nm remain challenging to directly visualize the fine microstructures of small airways in vivo. METHODS: We developed an ultrahigh-resolution diffractive endoscopic OCT at 800 nm to afford a resolving power of 1.7 µm (in tissue) with an improved contrast and a custom deep residual learning based image segmentation framework to perform accurate and automated 3D quantification of airway anatomy. RESULTS: The 800-nm diffractive OCT enabled the direct delineation of the structural components in the small airway wall in vivo. We further first demonstrated the 3D anatomic quantification of critical tissue compartments of small airways in sheep using the automated segmentation method. CONCLUSION: The deep learning assisted diffractive OCT provides a unique ability to access the small airways, directly visualize and quantify the important tissue compartments, such as airway smooth muscle, in the airway wall in vivo in 3D. SIGNIFICANCE: These pilot results suggest a potential technology for calculating volumetric measurements of small airways in patients in vivo.

15.
Acad Radiol ; 2022 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-35282990

RESUMEN

RATIONALE AND OBJECTIVES: At present, there is no available method to study the in vivo microstructures of the airway wall (epithelium, smooth muscle, adventitia, basement membrane, glands, cartilage). Currently, we rely on ex vivo histologic evaluation of airway biopsies. To overcome this obstacle, we have developed an endoscopic ultrahigh-resolution diffractive optical coherence tomography (OCT) system, operating at a wavelength of 800 nm, to non-invasively study the in vivo microstructures of the airway wall. Prior to human study, validation of diffractive OCT's ability to quantitate airway microstructural components is required. MATERIALS AND METHODS: To validate and demonstrate the accuracy of this OCT system, we used an ovine model to image small airways (∼ 2 mm in diameter). Histologic samples and correlated OCT images were matched. The cross-sectional area of the airway wall, lumen, and other microstructures were measured and compared. RESULTS: A total of 27 sheep were studied from which we identified 39 paired OCT-histology airway images. We found strong correlations between the OCT and the histology measurements of the airway wall area and the microstructural area measurements of the epithelium, basement membrane, airway smooth muscle, glands, cartilage, and adventitia. The correlations ranged from r=0.61 (p<0.001) for the epithelium to r=0.86 (p<0.001) for the adventitia with the correlation between the OCT and the histology measurements for the entire airway wall of r=0.76 (p<0.001). CONCLUSION: Given the high degree of correlation, these data validate the ability to acquire and quantify in vivo microscopic level imaging with this newly developed 800nm ultra-high resolution diffractive OCT system.

16.
Nat Commun ; 13(1): 1534, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35318318

RESUMEN

Scanning two-photon (2P) fiberscopes (also termed endomicroscopes) have the potential to transform our understanding of how discrete neural activity patterns result in distinct behaviors, as they are capable of high resolution, sub cellular imaging yet small and light enough to allow free movement of mice. However, their acquisition speed is currently suboptimal, due to opto-mechanical size and weight constraints. Here we demonstrate significant advances in 2P fiberscopy that allow high resolution imaging at high speeds (26 fps) in freely-behaving mice. A high-speed scanner and a down-sampling scheme are developed to boost imaging speed, and a deep learning (DL) algorithm is introduced to recover image quality. For the DL algorithm, a two-stage learning transfer strategy is established to generate proper training datasets for enhancing the quality of in vivo images. Implementation enables video-rate imaging at ~26 fps, representing 10-fold improvement in imaging speed over the previous 2P fiberscopy technology while maintaining a high signal-to-noise ratio and imaging resolution. This DL-assisted 2P fiberscope is capable of imaging the arousal-induced activity changes in populations of layer2/3 pyramidal neurons in the primary motor cortex of freely-behaving mice, providing opportunities to define the neural basis of behavior.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Animales , Encéfalo/diagnóstico por imagen , Ratones , Neuroimagen , Relación Señal-Ruido
17.
Biomed Opt Express ; 12(7): 3992-4002, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34457394

RESUMEN

OCT-based quantitative tissue optical properties imaging is a promising technique for intraoperative brain cancer assessment. The attenuation coefficient analysis relies on the depth-dependent OCT intensity profile, thus sensitive to tissue surface positions relative to the imaging beam focus. However, it is almost impossible to maintain a steady tissue surface during intraoperative imaging due to the patient's arterial pulsation and breathing, the operator's motion, and the complex tissue surface geometry of the surgical cavity. In this work, we developed an intraoperative OCT imaging probe with a surface-tracking function to minimize the quantification errors in optical attenuation due to the tissue surface position variations. A compact OCT imaging probe was designed and engineered to have a long working distance of ∼ 41 mm and a large field of view of 4 × 4 mm2 while keeping the probe diameter small (9 mm) to maximize clinical versatility. A piezo-based linear motor was integrated with the imaging probe and controlled based upon real-time feedback of tissue surface position inferred from OCT images. A GPU-assisted parallel processing algorithm was implemented, enabling detection and tracking of tissue surface in real-time and successfully suppressing more than 90% of the typical physiologically induced motion range. The surface-tracking intraoperative OCT imaging probe could maintain a steady beam focus inside the target tissue regardless of the surface geometry or physiological motions and enabled to obtain tissue optical attenuation reliably for assessing brain cancer margins in challenging intraoperative settings.

18.
Theranostics ; 11(15): 7222-7234, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34158846

RESUMEN

Background: Frozen section and smear preparation are the current standard for intraoperative histopathology during cancer surgery. However, these methods are time-consuming and subject to limited sampling. Multiphoton microscopy (MPM) is a high-resolution non-destructive imaging technique capable of optical sectioning in real time with subcellular resolution. In this report, we systematically investigated the feasibility and translation potential of MPM for rapid histopathological assessment of label- and processing-free surgical specimens. Methods: We employed a customized MPM platform to capture architectural and cytological features of biological tissues based on two-photon excited NADH and FAD autofluorescence and second harmonic generation from collagen. Infiltrating glioma, an aggressive disease that requires subcellular resolution for definitive characterization during surgery, was chosen as an example for this validation study. MPM images were collected from resected brain specimens of 19 patients and correlated with histopathology. Deep learning was introduced to assist with image feature recognition. Results: MPM robustly captures diagnostic features of glioma including increased cellularity, cellular and nuclear pleomorphism, microvascular proliferation, necrosis, and collagen deposition. Preliminary application of deep learning to MPM images achieves high accuracy in distinguishing gray from white matter and cancer from non-cancer. We also demonstrate the ability to obtain such images from intact brain tissue with a multiphoton endomicroscope for intraoperative application. Conclusion: Multiphoton imaging correlates well with histopathology and is a promising tool for characterization of cancer and delineation of infiltration within seconds during brain surgery.


Asunto(s)
Neoplasias Encefálicas , Encéfalo , Glioma , Cuidados Intraoperatorios , Microscopía de Fluorescencia por Excitación Multifotónica , Neoplasias Experimentales , Adulto , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Línea Celular Tumoral , Glioma/diagnóstico por imagen , Glioma/cirugía , Humanos , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Neoplasias Experimentales/diagnóstico por imagen , Neoplasias Experimentales/cirugía
19.
Opt Express ; 18(15): 16133-8, 2010 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-20720998

RESUMEN

This work presents a novel approach for a miniaturized optical scanning module based on lateral and piston motion of two commercial lenses by MEMS actuation. Two aspheric glass lenses of 1 mm diameter are assembled on two electrostatically actuated microstages moving along perpendicular axes to tilt optical path. The compact integration secures the effective beam aperture of 0.6 mm within the device width of 2 mm. The lens mass provides high-Q motions at low operating voltages of DC 5 V and AC 10 V, i.e., the lateral angle of 4.6 degrees at 277 Hz and the vertical angle of 5.3 degrees at 204 Hz. The device can provide a new direction for miniaturizing laser scanning based endoscopes or handheld projectors.


Asunto(s)
Lentes , Microtecnología/métodos , Fenómenos Ópticos , Microscopía Electrónica de Rastreo
20.
Biomed Opt Express ; 11(8): 4316-4325, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32923045

RESUMEN

Vascular-targeted photodynamic therapy (VTP) is an emerging treatment for tumors. The change of tumor vasculatures, including a newly-formed microvascular, in response to VTP, is a key assessment parameter for optimizing the treatment effect. However, an accurate assessment of vasculature, particularly the microvasculature's changes in vivo, remains challenging due to the limited resolution afforded by existing imaging modalities. In this study, we demonstrated the in vivo imaging of VTP effects on an A431 tumor-bearing window chamber model of a mouse with an 800-nm ultrahigh-resolution functional optical coherence tomography (UHR-FOCT). We further quantitatively demonstrated the effects of VTP on the size and density of tumor microvasculature before, during, and after the treatment. Our results suggest the promising potential of UHR-FOCT for assessing the tumor treatment with VTP in vivo and in real time to achieve an optimal outcome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA