Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38967776

RESUMEN

INTRODUCTION: More personalized alignment techniques in total knee arthroplasty (TKA) have recently been described particularly for the young and active patients. Performing the ideal tibial cut might be challenging with a conventional ancillary. Therefore the aims of this study were: (1) to describe specific tibial landmarks to optimize the tibial cut in TKA; (2) to compare the accuracy of the tibial cut with these landmarks compared to a conventional technique. METHODS: This retrospective case-control study compared primary TKAs performed using a conventional technique with extramedullary guide associated with specific tibial landmarks. For each case, one control patient was matched based on body mass index (BMI), age, preoperative Hip Knee Ankle (HKA) angle, and Medial Proximal Tibial Angle (MPTA). All control patients were operated by the same surgeon and similar conventional technique but without landmarks. The MPTA target was to reproduce preoperative deformity with a 3° of varus limit. 34 TKA were included in each group. There was no preoperative difference between both groups. Mean age was 63 years old ± 8. Mean BMI was 32 kg/m2 ± 5. Mean HKA was 170.6° ± 2.5. Mean MPTA was 85.1° ± 2.3. The radiographic assessment was performed preoperatively and at 2 months: HKA, mechanical Medial Distal Femoral Angle (mMDFA), MPTA, tibial slope, restoration of the joint line-height. RESULTS: The tibial landmarks corresponded to the line of insertion of the deep medial collateral ligament fibers extended to the capsular insertion above the Gerdy tubercle. The postoperative MPTA was significantly more varus (87.2° ± 1.6 in landmark group versus 88.3° ± 2.2; p = 0.027) and closer to preoperative bone deformity in landmark group (p = 0.002) with significantly less outliers than in the conventional group. There was no significant difference between both groups postoperatively for HKA (175.4° ± 2.3 versus 175.9° ± 2.5; p = 0.42); mMDFA (88.9° ± 2.3 versus 88.2° ± 2.1; p = 0.18); tibial slope (82.6° ± 1.9 versus 82.4° ± 2.6; p = 0.67), the restoration of the joint line-height (1.5 mm ± 2 versus 1.8 mm ± 2; p = 0.56). CONCLUSION: Specific tibial landmarks during TKA can be used to increase the accuracy of the tibial cut when using personalized alignment techniques in TKA. LEVEL OF EVIDENCE: IV.

2.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 814-821, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34557949

RESUMEN

PURPOSE: The purpose of this study was to evaluate: (1) improvement of functional and quality of life scores, (2) adverse events, (3) short-term implants survivorship of a newly designed fixed-bearing partial knee replacement (PKR) with a morphometric tibial tray in a large and multicentric population at a minimum follow-up of 2 years. METHODS: From 2017 to 2019, 479 medial PKR were implanted by 16 non-developing surgeons from United States, Europe, and Japan. Eight patients were lost to follow-up (1.8%). Standardized follow-up procedures included patient-reported outcomes (Oxford Knee Society score, Forgotten Joint Score, EQ VAS, EQ 5D), patient satisfaction, radiographic assessments, adverse event at 2 years. Comparisons between the preoperative and postoperative values were performed using Student t test. Kaplan-Meier survivorship analysis was performed with knee revision as the endpoint. RESULTS: The mean age was 65.6 ± 9.6 years. Mean body mass index was 29.5 ± 5.1 kg/m2. Oxford Knee Society score and Forgotten Joint Score, respectively, improved from 23.7 ± 8 and 16 ± 15.8 preoperatively to 42.4 ± 6.5 and 74 ± 24.9 at 2 years (p < 0.0001). Satisfaction Score was 92.3 ± 13.4 at 2 years. Ten re-operations (2.1%) were reported including seven implant removals (1.5%). No other adverse event was reported. The causes of conversion to total knee arthroplasty were: nickel allergy (n = 2), patellofemoral osteoarthritis (n = 1), pain (n = 1), deep infection (n = 3). Two re-operations were performed due to infection, and one for internal fixation for a tibial plateau fracture. The 2-year Kaplan-Meier survival estimate was 98.4%, with implant removals as the endpoint. CONCLUSION: This prospective multicentric study reported safe and reliable clinical outcomes of a morphometric PKR, which optimized tibial coverage and femoral fit, in a large population of patients worldwide at 2 years. LEVEL OF EVIDENCE: Prospective cohort study-therapeutic study, Level II.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Persona de Mediana Edad , Anciano , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Prospectivos , Prótesis de la Rodilla/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Reoperación , Estudios de Seguimiento , Estudios Retrospectivos
3.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1334-1346, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35552475

RESUMEN

PURPOSE: An anatomo-functional implant positioning (AFIP) technique in total knee arthroplasty (TKA) could restore physiological ligament balance (symmetric gap in extension, asymmetric gap in flexion). The purposes were to compare (1) ligament balancing in extension and flexion after TKA in the AFIP group, (2) TKA alignment, implant positioning and patellar tracking between AFIP and adjusted mechanical alignment (aMA) techniques, (3) clinical outcomes between both groups at 12 months. METHODS: All robotic-assisted TKA with an AFIP technique were included (n = 40). Exclusion criteria were genu valgum (HKA angle > 183°), extra-articular deformity more than 10°, and patellar maltracking (high-grade J-sign). One control patient with a TKA implanted by an aMA technique was matched for each case, based on age, body mass index, sex, and knee alignment. Ligament balancing (medial and lateral gaps in millimeters) in full extension and at 90° of flexion after TKA in the AFIP group was assessed with the robotic system. TKA alignment (HKA angle), implants positioning (femoral and tibial coronal axis, tibial slope, joint-line orientation), patellar tracking (patellar tilt and translation) and the Knee Society Score (KSS) at 6 and 12 months were compared between both groups. The ligament balancing was compared using a t test for paired samples in the AFIP group. The radiographic measurements and KSS scores were compared between groups using a t test for independent samples. RESULTS: In the AFIP group, there was no significant difference between the medial and lateral gap laxity in extension (NS). A significant opening of the lateral gap was observed in flexion compared to extension (mean: + 2.9 mm; p < 0.0001). The mean postoperative HKA angle was comparable between both groups (177.3° ± 2.1 in the AFIP group vs 176.8° ± 3.2; NS). In the AFIP group, the femoral anatomy was restored (90.9° ± 1.6) and the tibial varus was partially corrected (87.4° ± 1.8). The improvement of Knee and Function KSS at 6 months was better in the AFIP group (59.3 ± 11.9 and 51.7 ± 20, respectively, versus 49.3 ± 9.7 and 20.8 ± 13; p < 0.001). CONCLUSION: The AFIP concept allowed the restoration of the native knee alignment and a natural functional ligament pattern. With a more physiological target for ligament balancing, the AFIP technique had equivalent clinical outcomes at 12 months compared to aMA, with a faster recovery. LEVEL OF EVIDENCE: III retrospective therapeutic case control series.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Ligamentos/cirugía , Rango del Movimiento Articular/fisiología
4.
Int Orthop ; 47(2): 485-494, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36508053

RESUMEN

PURPOSE: To evaluate the feasibility of using a smartphone-based care management platform (sbCMP) and robotic-assisted total knee arthroplasty (raTKA) to collect data throughout the episode-of-care and assess if intra-operative measures of soft tissue laxity in raTKA were associated with post-operative outcomes. METHODS: A secondary data analysis of 131 patients in a commercial database who underwent raTKA was performed. Pre-operative through six week post-operative step counts and KOOS JR scores were collected and cross-referenced with intra-operative laxity measures. A Kruskal-Wallis test or a Wilcoxon sign-rank was used to assess outcomes. RESULTS: There were higher step counts at six weeks post-operatively in knees with increased laxity in both the lateral compartment in extension and medial compartment in flexion (p < 0.05). Knees balanced in flexion within < 0.5 mm had higher KOOS JR scores at six weeks post-operative (p = 0.034) compared to knees balanced within 0.5-1.5 mm. CONCLUSION: A smartphone-based care management platform can be integrated with raTKA to passively collect data throughout the episode-of-care. Associations between intra-operative decisions regarding laxity and post-operative outcomes were identified. However, more robust analysis is needed to evaluate these associations and ensure clinical relevance to guide machine learning algorithms.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Ortopedia , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Teléfono Inteligente , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía
5.
Arch Orthop Trauma Surg ; 143(3): 1599-1609, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35536354

RESUMEN

INTRODUCTION: To our knowledge, no papers have reported the results of robotic-assisted surgery for sequential bilateral Total Knee Arthroplasty (TKA). Indeed, sequential bilateral TKA present several benefits, as one single anesthesia, surgical episode, hospitalization, and rehabilitation. The purpose of our study was to evaluate peri-operative outcomes and compare the complication rates, clinical outcomes, and implant positioning of sequential bilateral TKA performed with a robotic-assisted system versus a conventional technique. MATERIALS AND METHODS: All patients who underwent a sequential bilateral robotic-assisted primary TKA (raTKA) in our institution between November 2019 and February 2021 were included. Twenty patients met the inclusion criteria and were matched with 20 sequential bilateral TKA performed with a conventional technique. The two groups were comparable for the demographic data and the preoperative parameters, including preoperative anticoagulation and ASA score. The minimum follow-up was 6 months. RESULTS: The operative time was significantly longer in the robotic group (< 0.0001), with a mean additional time of 29 min. There was no significant difference between both groups for postoperative blood loss, rate of blood transfusion, or postoperative pain. The average length of stay was 5 days. There was one early complication in the robotic group due to the tibial trackers. The functional outcomes were similar between both groups, except for the functional KSS score, which was better at 6 months in the robotic group (p < 0.0001). The restoration of the knee alignment and the distal femoral anatomy were significantly better in the robotic group than in the conventional group. CONCLUSIONS: Despite a longer operative time, the peri-operative parameters of sequential bilateral TKA were similar between robotic and conventional techniques. Further, sequential bilateral raTKA was at least as safe as a conventional technique, without additional risk of medical complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Proyectos Piloto , Articulación de la Rodilla/cirugía , Dolor Postoperatorio , Osteoartritis de la Rodilla/cirugía
6.
Knee Surg Sports Traumatol Arthrosc ; 29(3): 849-858, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32372282

RESUMEN

PURPOSE: Given the goal of achieving optimal correction and alignment after knee arthroplasty or high tibial osteotomy, literature focusing on the inter-individual variability of the native knee, tibia and femur with regards to the coronal or sagittal alignment is lacking. The aim of this study was to analyse normal angular values in the healthy middle-aged population and determine differences of angular values according to inter-individual features. The first hypothesis was that common morphological patterns may be identified in the healthy middle-aged non-osteoarthritic population. The second hypothesis was that high inter-individual variability exists with regards to gender, ethnicity and alignment phenotype. METHODS: A CT scan-based modelling and analysis system was used to examine the lower limb of 758 normal healthy patients (390 men, 368 women; mean age 58.5 ± 16.4 years) with available data concerning angular values and retrieved from the SOMA database. The hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), posterior distal femoral angle (PDFA), posterior proximal tibial angle (PPTA) and non weight-bearing joint line convergence angle (nwJLCA) were then measured for each patient. Results were analysed for the entire cohort and based on gender, ethnicity and phenotype. RESULTS: The mean HKA was 179.4° ± 2.6°, LDFA: 85.8° ± 2.0°, MPTA: 85.6° ± 2.4°, PDFA: 85.2° ± 1.5°, PPTA: 83.8° ± 2.9° and nwJLCA: 1.09° ± 0.9°. Gender was associated with higher LDFA and lower HKA for men. Ethnicity was associated with greater proximal tibial vara and distal femoral valgus for Asian patients. Patients with an overall global varus alignment had more tibia vara and less femoral valgus than patients with an overall valgus alignment. CONCLUSION: Even if significant differences were found based on subgroup analysis (gender, ethnicity or phenotype), this study demonstrated that neutral alignment is the main morphological pattern in the healthy middle-aged population. This neutrality is the result from tibia vara compensated by an ipsilateral femoral valgus. LEVEL OF CLINICAL EVIDENCE: III, retrospective cohort study.


Asunto(s)
Fémur/anatomía & histología , Articulación de la Rodilla/anatomía & histología , Tibia/anatomía & histología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Tobillo/anatomía & histología , Tobillo/diagnóstico por imagen , Artroplastia de Reemplazo de Rodilla , Niño , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Cadera/anatomía & histología , Cadera/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Osteotomía , Valores de Referencia , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tibia/cirugía , Tomografía Computarizada por Rayos X , Adulto Joven
7.
J Arthroplasty ; 36(7): 2502-2509, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33744083

RESUMEN

BACKGROUND: The use of morphometric implants in total knee arthroplasty (TKA) has shown better early clinical outcomes compared to conventional implants. The primary objective of this study is to evaluate the functional outcome and the implant survivorship of a morphometric TKA at a minimum of 5 years of follow-up. METHODS: From May 2012 to June 2015, all patients undergoing primary TKA with a single design of morphometric posterior-stabilized prosthesis (Persona; Zimmer) in a prospective observational single-center study were evaluated. The Knee Society Scoring System (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed preoperatively, 1, 3, and 5 years postoperatively. Kaplan-Meier was used to calculate survivorship of the implants. The average follow-up was 75 months. RESULTS: In total, 237 TKAs were performed in 235 patients with a mean age of 73 years (49-90). The KSS Knee Score increased from 44.7 (13-64) preoperatively to 93.6 (71-100), the KSS Function Score from 45.8 (17-69) to 92.2 (51-98), and the KSS Satisfaction Score from 26.6 (16-51) to 41 (35-55) at 5 years of follow-up. Similarly, for the KOOS score, a significant improvement of all the subscales was observed at 5 years of follow-up. Implant survival without reoperation at 5 years of follow up was 98.72% (95% confidence interval 0.95-1.00). CONCLUSION: This is the first study demonstrating that significant improvements of the functional scores with good survivorship can be achieved at a minimum of 5 years of follow-up with TKA using morphometric implants.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Osteoartritis , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/cirugía , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Resultado del Tratamiento
8.
J Arthroplasty ; 36(2): 657-663, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32978026

RESUMEN

BACKGROUND: The purpose of this study was to compare the functional outcomes and implant survivorship at a minimum of 5 years of follow-up of several reconstruction techniques with or without metaphyseal cone and stems of variable length. METHODS: A retrospective comparative matched analysis was performed from 2 prospectively collected databases. Only patients who underwent revision total knee arthroplasty procedures for aseptic causes using a single design of rotating hinge knee with a minimum of 5 years of follow-up were analyzed. Patients were separated into 3 groups: trabecular metal (TM) cones + short cemented stems (TM + short stem [SS]), TM cones + long uncemented stems (TM + long stem [LS]), and no cone (NC) + long uncemented stems (NC + LS). A matching process based on age (±5 years) was realized. RESULTS: About 99 patients were included; 33 in the TM + SS group, 33 in the TM + LS group, and 33 in the NC + LS group. The mean time of follow-up was 9.3 years. A significant difference of the improvement of subscale pain, symptom, activities of daily living, quality of life of the Knee Injury and Osteoarthritis Outcome score and knee, function of the Knee Society Score was observed in favor of TM + SS group compared with the 2 other groups. At 8 years of survivorship, the components free of revision for any cause were 90.9% for the TM + SS group, 84.9% for the TM + LS group, and 90.6% for the NC + LS group. CONCLUSION: The use of a short cemented tibial stem combined with a TM cone in revision total knee arthroplasty offers identical survival rate with better functional outcome compared with the use of a long uncemented stem associated with TM cones or metallic augments at a minimum of 5 years of follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Actividades Cotidianas , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Falla de Prótesis , Calidad de Vida , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
9.
Arch Orthop Trauma Surg ; 141(12): 2027-2034, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34259929

RESUMEN

PURPOSE: Most opponents of assistive technologies in orthopedic surgery consider them as a marketing ruse or fashion. Our hypothesis was that many innovations in modern knee arthroplasty are not following the Scott Parabola. This parabola represents the visual curve of a procedure or therapy showing great promise at the beginning, becoming the standard treatment after reports of encouraging results, only to fall into disuse due to adverse outcome reports. This study aimed to assess the interest in these assistive technologies by (1) their number of publications/year and (2) their actual surgical use reported in the National Joint Registries. METHODS: The search was performed through PubMed, EMBASE, and MEDLINE databases from 1997 to 2021 inclusive to identify all available literature that described the use and results of assistive technologies or new surgical techniques in knee arthroplasty. In the Australian and Norwegian registries, the number of cases performed with these techniques in knee arthroplasty has been quantified year by year. RESULTS: Following the initial online search, a total of 4085 articles was found. After the assessment mentioned above, 2106 articles were included in the study. The orthopedic techniques assessed in this study are not following the "Scott's parabola" in the literature. Computer-assisted knee arthroplasty and patient-specific instrumentation have increased quickly to have reached a plateau, with a stable number of publications over the last 6 years. The number of publications concerning robotic surgery, accelerometers and sensors continue to rise. In the Australian registry, the proportion of primary TKA performed by computer-assisted systems increased from 2.4% in 2003 to 32% in 2019. In the Norwegian registry, the proportion of computer-assisted TKA remained between 8 and 12% of primary TKA since 2007. CONCLUSION: Most of the innovations in modern knee arthroplasty are not following the Scott Parabola. After a fast rise, these techniques do not disappear but continue to evolve. Their evolution is synergistic, and techniques appeared to be linked to each other's. Despite persisting concerns about the cost-efficiency of assisting technologies in knee arthroplasties, the interest and use do not decrease and seems to be directly linked to an exponential increase in interest for a better understanding of alignment targets and improved functional recovery.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Dispositivos de Autoayuda , Australia , Humanos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Sistema de Registros , Resultado del Tratamiento
10.
Arch Orthop Trauma Surg ; 141(12): 2049-2058, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34255173

RESUMEN

INTRODUCTION: The ROSA (Robotic Surgical Assistant) Knee system (Zimmer Biomet, Warsaw, IN) for total knee arthroplasty (TKA) can be considered as collaborative robotics, where the surgeon remains in charge of the procedure and collaborates with a smart robotic tool, to perform the surgery with a high accuracy and reproducibility. The aim was to describe: (1) its concept and surgical technique; (2) its advantages and potential limits; (3) the early experience with this system. MATERIALS AND METHODS: The goal during its development phase was to keep the surgeon active and at the center of the operation: the surgeon handles the saw and performs the cuts while the robotic arm places and holds the guide at the right place. The ROSA knee platform assists the surgeon for the distal femoral cut, the femoral component sizing and positioning, the tibial cut and the ligament balance. This robotic system has two options: image-based with 3D virtual model; or image-less, based on intraoperative landmarks acquisition. All the classic surgical techniques can be used: measured resection, gap balancing, functional alignment, kinematic alignment. Some techniques recently developed are more ROSA-specific: Robotic personalized TKA, ROSA-FuZion technique. RESULTS: Its advantages as compared to other available systems include: radiographs in standing position, collaborative robotic system where the robot completes the surgeon skills, "off-the-shelf" implants, predictive robotic with concept of machine learning incorporated into the system. Two cadaveric studies have reported the high accuracy and reproducibility of this device. This robotic system is recent and currently no clinical series has enough follow-up to report clinical outcomes. CONCLUSION: The ROSA knee system is a robotically assisted semi-autonomous surgical system with some specific characteristics. The aim of this collaborative robotic system is to improve the accuracy and reliability of the bone resections and the ligament balancing, without replacing the steps well performed by the surgeon.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Rosa , Humanos , Articulación de la Rodilla/cirugía , Reproducibilidad de los Resultados
11.
Knee Surg Sports Traumatol Arthrosc ; 28(12): 3849-3857, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32008058

RESUMEN

PURPOSE: Prior studies have compared unicompartmental knee arthroplasty (UKA) with high tibial osteotomy (HTO) suggesting that both procedures had good functional outcomes. But none had established the superiority of one of the two procedures for patients with high expectation including return to impact sport. The aim of this study was to compare functional outcomes and ability to return to impact sport of active patients defined with a pre-arthritis University of California and Los Angeles activity (UCLA) score > 8, after UKA or HTO procedures. METHODS: A retrospective review of patients with a pre-arthritis UCLA score > 8 operated between January 2014 and September 2017 has identified 91 patients with open-wedge HTO and 117 patients with UKA. A matching process based on age (± 3 years) and gender allowed to include 50 patients in each group for comparative analysis. Patient reported outcomes included Knee Osteoarthritis Outcomes Score (KOOS), UCLA Score, Knee Society Score (KSS) and time to return to sport or previous professional activities at 3, 6, 12 and 24 months following surgery. RESULTS: Mean time to return to sport activities or previous professional activities were significantly lower for the HTO group than for UKA group [respectively, 4.9 ± 2.2 months for HTO group vs 5.8 ± 6.2 months for UKA group (p = 0.006) and 3 ± 3 months for HTO group vs 4 ± 3 months for UKA group (p = 0.006)]. At 24-month follow-up, UCLA score, KOOS Sports Sub-score and KSS activity score were significantly higher for HTO group than for UKA group (Δ: 2 CI 95% (1.3-2.5 points) p < 0.0001, (Δ: 10.9 CI 95% (2.9-18.9 points) p = 0.04 and Δ: 7.8 CI 95% (2.4-13.4 points) p = 0.006, respectively) and 31 patients (62%) were practicing impact sport in the HTO group versus 14 (28%) in the UKA group (odd-ratio 4.2 CI 95% (1.8-9.7) p < 0.0001). CONCLUSION: HTO offers statistically significant quicker return to sport activities and previous professional activities with a higher rate of patients able to practice impact activity (62% for HTO vs 28% for UKA) and better sports related functional scores at two years after surgery compared to UKA. LEVEL OF EVIDENCE: III retrospective case-control study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Osteotomía/estadística & datos numéricos , Volver al Deporte/estadística & datos numéricos , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Medición de Resultados Informados por el Paciente , Estudios Retrospectivos , Deportes
12.
Knee Surg Sports Traumatol Arthrosc ; 28(9): 2854-2862, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31352498

RESUMEN

PURPOSE: Patient-specific cutting guides (PSCGs) have been advocated to improve the accuracy of deformity correction in opening-wedge high-tibial osteotomies (HTO). It was hypothesized that PSCGs for HTO would have a short learning curve. Therefore, the goals of this study were to determine the surgeons learning curve for PSCGs used for opening-wedge HTO assessing: the operating time, surgeons comfort levels, number of fluoroscopic images, accuracy of post-operative limb alignment and functional outcomes. METHODS: This prospective cohort study included 71 consecutive opening-wedge HTO with PSCGs performed by three different surgeons with different experiences. The operating time, the surgeon's anxiety levels evaluated using the Spielberger State-Trait Anxiety Inventory (STAI), the number of fluoroscopic images was systematically and prospectively collected. The accuracy of the postoperative alignment was defined by the difference between the preoperative targeted correction and the final post-operative correction both measured on standardized CT-scans using the same protocol (ΔHKA, ΔMPTA, ΔPPTA). Functional outcomes were evaluated at 1 year using the different sub-scores of the KOOS. Cumulative summation (CUSUM) analyses were used to assess learning curves. RESULTS: The use of PSCGs in HTO surgery was associated with a learning curve of 10 cases to optimize operative time (mean operative time 26.3 min ± 8.8), 8 cases to lessen surgeon anxiety levels, and 9 cases to decrease the number of fluoroscopic images to an average of 4.3 ± 1.2. Cumulative PSCGs experience did not affect accuracy of post-operative limb alignment with a mean: ΔHKA = 1.0° ± 1.0°, ΔMPTA = 0.5° ± 0.6° and ΔPPTA = 0.4° ± 0.8°. No significant difference was observed between the three surgeons for these three parameters. There was no statistical correlation between the number of procedures performed and the patient's functional outcomes. CONCLUSION: The use of PSCGs requires a short learning curve to optimize operating time, reduce the use of fluoroscopy and lessen surgeon's anxiety levels. Additionally, this learning phase does not affect the accuracy of the postoperative correction and the functional results at 1 year. LEVEL OF EVIDENCE: II: prospective observational study.


Asunto(s)
Curva de Aprendizaje , Tempo Operativo , Osteotomía/métodos , Tibia/cirugía , Adulto , Femenino , Fluoroscopía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Periodo Posoperatorio , Estudios Prospectivos , Tomografía Computarizada por Rayos X
13.
Knee Surg Sports Traumatol Arthrosc ; 28(10): 3173-3182, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31773202

RESUMEN

PURPOSE: A recent study reported that positioning a K-wire to intersect the cutting plane at the theoretical lateral hinge location increases the lateral hinge's resistance to fracture during the opening of opening wedge high tibial osteotomy (OWHTO). The purpose of this study was to evaluate the clinical relevance of the use of this K-wire and its benefits in terms of lateral hinge protection during OWHTO in daily practice. METHODS: A retrospective comparative study identified 206 patients who underwent OWHTO from January 2014 to December 2017. Among these patients, 71 had an additional K-wire (HK + group), whereas 135 did not (HK- group). The subjects meeting the inclusion criteria were included in a matched pairing process, which identified 60 patients in the HK + group and 60 patients in the HK- group. Mean follow-up time was 2.3 ± 1.0 years (range 2-4.2). Radiographic outcomes were evaluated with intraoperative and postoperative fluoroscopic imaging and with CT imaging at 6 weeks post OWHTO surgery. The knee osteoarthritis outcomes score (KOOS) was used and time needed to return to work and any kind of sports was collected. RESULTS: Thirty six patients (30%) were found to have a LHF. Among these patients, 26 (72%) did not have an additional K-wire positioned at their theoretical lateral hinge location (HK- group) during the procedure. LHF rate for patients without additional K-wire group (HK-) was 43.3%, whereas it was 16.7% for the patients with an additional K-wire (HK +) [Odd ratio 3.8 95% CI 1.6-8.3; p = 0.005]. The mean time to return to work, return to any kind of sports, and bone union was significantly shorter for HK + group (p < 0.05). CONCLUSION: This study demonstrated that during OWHTO, positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location reduced the number of intraoperative lateral hinge fractures. LEVEL OF EVIDENCE: III retrospective case-control study.


Asunto(s)
Hilos Ortopédicos , Osteoartritis de la Rodilla/cirugía , Osteotomía/efectos adversos , Osteotomía/instrumentación , Tibia/cirugía , Fracturas de la Tibia/prevención & control , Adulto , Estudios de Casos y Controles , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Osteotomía/métodos , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
14.
Knee Surg Sports Traumatol Arthrosc ; 28(3): 751-758, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30783689

RESUMEN

PURPOSE: It was hypothesized in this in-vitro study that positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location would limit the cut depth and help preserve the lateral hinge during the opening of the osteotomy. Objectives were (1) to compare the mechanical resistance of the hinge and the protective effect of leaving the K-wire during the opening procedure (2) to check if the K-wire would limit the depth of the osteotomy. METHODS: An ex-vivo mechanical study, testing 5 pairs of fresh-frozen tibias, was designed. CT-scan based Patient-specific cutting guides were obtained to define the cutting plane and the location of the K-wire at the hinge, using standardized 3D planning protocol. In each pair, OWHTO was performed either with or without the K-wire. To evaluate the hinge's resistance to fracture, the specimens were rigidly fixed at the proximal tibia and a direct load was applied on the free tibial diaphysis to open the osteotomy. The maximum load at breakage, maximum permissible displacement and maximal angulation of the osteotomy before hinge failure was measured. To assess the preservation of an unscathed hinge (protected by the K-wire), the distance from the end of the osteotomy cut to the lateral tibial cortical was measured in mm. RESULTS: The maximum load to hinge breakage in the K-wires PsCG knees compared to the control group (48.3 N vs 5.5 N, p = 0.004), the maximum permissible displacement (19.8 mm vs 7.5 mm, p = 0.005) and the maximal angulation of the osteotomy before hinge breakage (9.9° vs 2.9°, p = 0.002) were all statistically superior in the K-wires PsCG knees compared to the control group. A mean distance of 10 ± 1 mm between cut-bone (saw-print) and lateral hinge cortical bone was found post-performing the osteotomy and the hinge failing. CONCLUSION: The maximum load to breakage and the maximum permissible displacement were, respectively, 880% and 260% higher during the opening of the OWHTO in using K-wires compared to the non-K-wire control group. This confirms the mechanical advantage of using a K-wire for both stabilization and protecting the Hinge during OWHTO. This comparative cadaveric study shows an improvement of the lateral hinges resistance to failing during the opening of the osteotomy. This can be achieved by the placement of a K-wire intersecting the cutting plane at the theoretical location of the lateral hinge.


Asunto(s)
Hilos Ortopédicos , Osteoartritis de la Rodilla/cirugía , Osteotomía/instrumentación , Osteotomía/métodos , Tibia/cirugía , Fracturas de la Tibia/prevención & control , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/fisiopatología , Osteotomía/efectos adversos , Complicaciones Posoperatorias/prevención & control , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X
15.
Clin Orthop Relat Res ; 477(9): 2017-2029, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30839317

RESUMEN

BACKGROUND: Accelerometer-based navigation is a handheld navigation tool that was introduced to offer a simpler technique compared with more-cumbersome computer-assisted surgery (CAS). Considering the increasing number of adopters, it seems important to evaluate the potential clinical benefits of this technology compared with conventional TKA. QUESTIONS/PURPOSES: In this systematic review, we asked: (1) Is accelerometer-based navigation more accurate than conventional TKA? (2) Does accelerometer-based navigation provide better functional outcome than conventional TKA? (3) Does accelerometer-based navigation increase surgical time or decrease the risk of complications or reoperations compared with conventional TKA? METHODS: This systematic review included all comparative prospective and retrospective studies published in the MEDLINE/PubMed and Cochrane libraries over the last 10 years. Inclusion criteria were all studies in English that compared accelerometer-based navigation with conventional TKA. Eleven studies met these criteria with 621 knees in accelerometer-based navigation group and 677 knees in conventional TKA group. Results related to alignment, objective and subjective functional scores, duration of surgery, complications and reoperations were extracted and compared between accelerometer-based-navigation and conventional TKA. Methodological quality was assessed using Methodological Index for Non-Randomized Studies (MINORS) tool (for nonrandomized control trials) and Cochrane Risk of Bias (for randomized control trials (RCTs). All studies with fair or better quality were included. Four RCTs and six nonrandomized studies comparing accelerometer-based navigation to conventional TKA were found. RESULTS: Inconsistent evidence on mechanical axis alignment was found, with five of nine studies slightly favoring the accelerometer-based navigation group, and the other four showing no differences between the groups. Only two of eight studies favored accelerometer-based navigation in terms of tibial component alignment in the coronal plane; the other six found no between-group differences. Similarly, mixed results were found regarding other metrics related to component alignment; a minority of studies favored accelerometer-based navigation by a small margin, and most studies found no between-group differences. Only three studies evaluated functional outcome and none of them showed a difference in range of motion or patient-reported outcomes. Most studies, six of seven, found no between-group differences concerning surgical time; one study demonstrated a slight increase in time with accelerometer-based navigation. There were no between-group differences in terms of the risk of complications, which generally were uncommon in both groups, and no reoperations or revisions were reported in either group. CONCLUSIONS: We found conflicting evidence about whether accelerometer-based navigation reduces the number of coronal-plane outliers or improves alignment to a clinically important degree, and we found no evidence that it improves patient-reported outcomes or reduces the risk of complications or reoperations. Accelerometer-based navigation may increase surgical time. The overall quality of the evidence was low, which suggested that any observed benefits were overestimated. Given the absence of higher-quality evidence demonstrating compelling benefits of this accelerometer-based navigation technology, it should not be widely adopted. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Acelerometría/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Adulto , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuronavegación/métodos , Tempo Operativo , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Arthroplasty ; 34(3): 465-468, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30503305

RESUMEN

BACKGROUND: Numerous series have documented short and mid-term successes with cemented, metal-backed modern unicompartmental knee arthroplasty (UKA) for avascular osteonecrosis of the knee (AVN). However, data are lacking regarding long-term implant fixation and patient function. The aim of this study is therefore to evaluate the long-term clinical outcome and implant survivorship of patients who underwent UKA for medial knee osteonecrosis (ON). METHODS: Twenty-nine consecutive UKAs performed by 2 senior surgeons (>50 UKAs a year) in 28 patients (19 women and 9 men with a mean age of 67 years) with medial unicompartmental AVN of the knee between 1989 and 2001 were retrospectively reviewed. AVN was diagnosed using X-ray, magnetic resonance imaging scan, and finally confirmed by postoperative sample analysis. The mean patient body mass index was 27 kg/m2. Etiologies were spontaneous/idiopathic AVN in 19 knees (66%) and secondary AVN in 10 knees (33%). The mean follow-up was 21 years (range 15-26). RESULTS: At 15 years, survivorship of the components free of revision for any cause was 92% (95% confidence interval 87-97). At latest follow-up, 26 years, survivorship of the components free of revision for any reason was 83% (95% confidence interval 74-95). No survivorship difference was found between the patients suffering from spontaneous or secondary ON of the knee (83% vs 90%, P = .6). At latest follow-up, the mean Knee Society Scoring system Knee was 89 points (range 68-100) and 83 (range 66-96) for Knee Society Scoring system Function. CONCLUSION: In the longest series to date, medial UKA for treatment of AVN was associated with high survival rates and stable clinical improvement. UKA is a durable and efficient option to treat patients with unicompartmental ON of the knee. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Articulación de la Rodilla/cirugía , Osteonecrosis/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Índice de Masa Corporal , Femenino , Humanos , Rodilla/cirugía , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Radiografía , Estudios Retrospectivos , Cirujanos , Resultado del Tratamiento
17.
J Arthroplasty ; 34(12): 2903-2908, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31451392

RESUMEN

BACKGROUND: During medial unicompartmental knee arthroplasty (UKA), tibial tray implantation requires compromise between bone coverage and rotational position. It was hypothesized that morphometric tibial tray (MTT) would improve implant positioning and subsequently clinical outcomes as compared to symmetric tibial tray (STT). METHODS: A total of 106 patients who underwent medial UKA in our department between January 2017 and March 2018 were included matched on gender and age (53 in each group). Inclusion criteria were symptomatic medial femorotibial osteoarthritis, functional anterior cruciate ligament, primary arthritis, or osteonecrosis. Rotation of the tibial implant, tibial bone coverage, medial and posterior overhang were assessed with a postoperative computed tomography scan. The Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score Short Form (KOOS SF), and the quality of life score EuroQoL 5-Dimensions 3-Levels (EQ5D3L) were assessed at a minimum of 1-year follow-up. RESULTS: Implants of the STT group exhibited more external rotation (6.3° ± 4.02° vs 4.6° ± 3.59°; P = .04), and medial and posterior overhang >3 mm (35% vs 0% and 22% vs 0%; P < .0001) but no difference for tibial bone coverage (97.3% ± 11.35% vs 94.7% ± 10.89%; P = .23). Global KSS (188.6 ± 6.6 vs 175.2 ± 31.7; P < .01), KOOS SF (16.9 ± 6.1 vs 22.5 ± 11.8; P < .003), and EQ5D3L (1 ± 0.1 vs 0.9 ± 0.2; P < .001) were higher in MTT group. According to the multivariate analysis, MTT had a positive independent effect on the KSS, KOOS SF, and EQ5D3L. CONCLUSION: The use of an MTT in medial UKA allowed better implant positioning when decreasing the rate of overhang; superior short-term clinical outcomes were found as compared to STT.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Artroplastia de Reemplazo de Rodilla/métodos , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Calidad de Vida , Estudios Retrospectivos , Tibia/cirugía , Resultado del Tratamiento
18.
J Arthroplasty ; 34(11): 2799-2803, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31301912

RESUMEN

BACKGROUND: Although the utility of robotic surgery has already been proven in cadaveric studies, it is our hypothesis that this newly designed robotically assisted system will achieve a high level of accuracy for bone resection. Therefore, we aimed to analyze in a cadaveric study the accuracy to achieve targeted angles and resection thickness. METHODS: For this study, 15 frozen cadaveric specimens (30 knees) were used. In this study, Zimmer Biomet (Warsaw, IN) knees, navigation system, and robot (ROSA Knee System; Zimmer Biomet) were used. Eight trained, board-certified orthopedic surgeons performed robotically assisted total knee arthroplasty implantation using the same robotic protocol with 3 different implant designs. The target angles obtained from the intraoperative planning were then compared to the angles of the bone cuts performed using the robotic system and measured with the computer-assisted system considered to be the gold standard. For each bone cut the resection thickness was measured 3 times by 2 different observers and compared to the values for the planned resections. RESULTS: All angle mean differences were below 1° and standard deviations below 1°. For all 6 angles, the mean differences between the target angle and the measured values were not significantly different from 0 except for the femoral flexion angle which had a mean difference of 0.95°. The mean hip-knee-ankle axis difference was -0.03° ± 0.87°. All resection mean differences were below 0.7 mm and standard deviations below 1.1mm. CONCLUSION: Despite the fact that this study was funded by Zimmer Biomet and only used Zimmer Biomet implants, robot, and navigation tools, the results of our in vitro study demonstrated that surgeons using this new surgical robot in total knee arthroplasty can perform highly accurate bone cuts to achieve the planned angles and resection thickness as measured using conventional navigation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rodilla/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Int Orthop ; 43(10): 2285-2291, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30413851

RESUMEN

PURPOSE: The distal femoral varization osteotomy (DFVO) by a lateral opening wedge osteotomy is an established intervention for patients suffering from lateral femoro-tibial osteoarthritis on a genu valgum deformity. In order to improve the accuracy of this correction, the use of a customized cutting guide (PSI) has been proposed as an alternative to conventional technique. The objective of our study was to compare the accuracy of post-operative alignment following DFVO in the coronal and sagittal plane using either a conventional abacus technique or PSI guide. METHOD: Twenty-one patients that underwent lateral opening wedge osteotomy from a technique using PSI based on 3D CT-scans were matched 1:1 to 21 patients operated on using a conventional technique (pre-operative planning performed on standard radiographs). The accuracy of the correction was analyzed, comparing coronal and sagittal mechanical post-operative angles with pre-operative planning. RESULTS: With regard to alignment in the coronal plane (HKA correction), our study demonstrated a significant improvement in the accuracy of the correction obtained in the PSI group compared to the conventional group (0.43 ± 0.50 vs 3.95 ± 1.64 p < 0.001). In the sagittal plane (PDFA correction), we also found a significant improvement in correction accuracy in the PSI group (0.52 ± 0.60 vs 3.10 ± 1.83 p < 0.001). There was a significant decrease in operating time (delta 7.7 ± 3.07 (1.5-13.9) (p = 0.0.161) and fluoroscopic images taken (6.9 ± 0.54 (5.8-8) p < 0.001). CONCLUSION: Our results suggest that the use of PSI in DFVO improves the accuracy of correction in both the coronal and sagittal planes compared to conventional techniques.


Asunto(s)
Desviación Ósea/cirugía , Fémur/diagnóstico por imagen , Fémur/cirugía , Genu Valgum/cirugía , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos , Modelación Específica para el Paciente , Adulto , Desviación Ósea/etiología , Desviación Ósea/prevención & control , Femenino , Genu Valgum/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteotomía/instrumentación , Atención Perioperativa , Tibia/cirugía
20.
Int Orthop ; 43(12): 2757-2765, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31273430

RESUMEN

INTRODUCTION: Several recent studies have reported accurate and reliable use of patient-specific cutting guides (PSCG) for medial opening-wedge high tibial osteotomy (OW-HTO); however, a majority of these are small cases series or ex-vivo reports. The hypothesis of this study was that performing an OW-HTO with PSCG results in a reliable and accurate correction with good or satisfactory patient-reported functional outcomes at a mean of two years. We also hypothesized that the use of PSCG would not increase the rate of specific or non-specific complications. METHODS: In this single-centre, observational study, a prospective cohort of a hundred patients (age < 60 years with isolated medial knee osteoarthritis and significant metaphyseal tibial vara) were included between February 2014 and November 2017 to investigate the safety and accuracy of OW-HTO using PSCG. The accuracy of post-operative alignment was defined by the difference between the desired correction defined pre-operatively and the correction obtained post-operatively measured on CT scan (ΔHKA, ΔMPTA, ΔPPTA). Functional outcomes were evaluated by the difference between the value obtained in the pre-operative questionnaire and that obtained at the last follow-up (mean 2 years) using the KOOS and UCLA activity scale. Intra-operative and post-operative complications were recorded. RESULTS: The mean patient age was 44.17 ± 6.77 years; no patient was lost to follow-up at a mean of two years. The mean ΔHKA was 1 ± 0.95°, the mean ΔMPTA was 0.54 ± 0.63°, and the mean ΔPPTA was 0.43 ± 0.8°. No significant differences (all p values > 0.05) were observed between the desired correction defined pre-operatively and the correction obtained post-operatively (ΔHKA, ΔMPTA, ΔPPTA). An improvement of 27 ± 25 for the KOOS Pain, 28 ± 26 for the KOOS symptoms, 27 ± 28 for the KOOS ADL, 26 ± 33 for the KOOS sport/rec, 28 ± 38 for the KOOS QOL, and 2.6 ± 2.4 for the UCLA was obtained as compared with the pre-operative values (all p < 0.0001). No procedures observed were abandoned, and the PSCG was well positioned in all cases. The overall complication rate was 32% up to two years post-operatively, most of them being classed as minor events (28%). CONCLUSION: Performing an OW-HTO with PSCG produces an accurate correction with good functional outcomes at a mean of two years. Furthermore, there is no increase in the rate of specific or non-specific complications. A study to assess the reproducibility of this technique, regardless of the surgical level, is needed.


Asunto(s)
Tibia/cirugía , Adulto , Humanos , Persona de Mediana Edad , Osteotomía , Complicaciones Posoperatorias , Periodo Posoperatorio , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA