Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Int J Comput Dent ; 24(1): 65-76, 2021 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-34006064

RESUMEN

INTRODUCTION: Mixed reality (MR) represents a new evolution in technological development that combines both virtual reality (VR) and augmented reality (AR) to create a blend of the physical and digital worlds. However, the potential role of MR in preoperative diagnostics in oral and maxillofacial surgery has not been scientifically investigated and remains generally unclear. This article presents a workflow that integrated MR in its scheme. It also evaluates the potential benefit of MR compared with its predecessors, VR and AR. MATERIAL AND METHODS: MR technology was used to plan the surgical treatment of a clinical case with an extensive tumor of the left maxilla. A workflow proposal incorporating both the surgeon and radiation oncologist is presented based on this experience. A total of 10 examiners rated the usability and applicability of MR for daily routines. RESULTS: MR showed good results during preoperative planning for a surgically extensive case in terms of displaying 3D structures and enhancing the physical and virtual interactions among the examiners. Previously described drawbacks of other VR/AR applications such as nausea and motion sickness were not observed with MR. However, MR seems to lack intraoperative usability, which is a drawback. CONCLUSION: MR shows great potential in improving the preoperative assessment of 3D DICOM datasets and thus facilitating diagnostic measures. However, further improvements should be made to implement an MR workflow and incorporate it into the clinical treatment planning tree.


Asunto(s)
Realidad Aumentada , Cirugía Bucal , Realidad Virtual , Humanos , Simbiosis , Tecnología
2.
Oral Maxillofac Surg ; 27(1): 33-41, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35249150

RESUMEN

INTRODUCTION: Three-dimensional facial scans have recently begun to play an increasingly important role in the peri-therapeutic management of oral and maxillofacial and head and neck surgery cases. Face scan images can be generated by optical facial scanners utilizing line-laser, stereophotography, or structured light modalities, as well as from volumetric data: for example, from cone beam computed tomography (CBCT). This study aimed to evaluate whether two low-cost procedures for the creation of three-dimensional face scan images were capable of producing sufficiently accurate data sets for clinical analysis. MATERIALS AND METHODS: Fifty healthy volunteers were included in the study. Two test objects with defined dimensions (Lego bricks) were attached to the forehead and the left cheek of each volunteer. Facial anthropometric values (i.e., the distances between the medial canthi, the lateral canthi, the nasal alae, and the angles of the mouth) were first measured manually. Subsequently, face scans were performed with a smart device and manual photogrammetry and the values obtained were compared with the manually measured data sets. RESULTS: The anthropometric distances deviated, on average, 2.17 mm from the manual measurements (smart device scanning deviation 3.01 mm, photogrammetry deviation 1.34 mm), with seven out of eight deviations being statistically significant. For the Lego brick, from a total of 32 angles, 19 values demonstrated a significant difference from the original 90° angles. The average deviation was 6.5° (smart device scanning deviation 10.1°, photogrammetry deviation 2.8°). CONCLUSION: Manual photogrammetry demonstrated greater accuracy when creating three-dimensional face scan images; however, smart devices are more user-friendly. Dental professionals should monitor camera and smart device technical improvements carefully when choosing and adequate technique for 3D scanning.


Asunto(s)
Cara , Imagenología Tridimensional , Fotogrametría , Humanos , Cara/diagnóstico por imagen , Frente , Imagenología Tridimensional/métodos , Nariz , Fotogrametría/métodos , Estudios Prospectivos
3.
Artículo en Alemán | MEDLINE | ID: mdl-17968765

RESUMEN

Malignant hyperthermia (MH) is a rare, often life-threatening complication of general anaesthesia. The timely diagnosis of an MH crisis in onset, as a prerequisite for successful therapy, can be difficult for the anaesthetist because of the few and non-specific early symptoms. This is even more so in patients in whom anaesthesia with MH trigger substances has already been performed in the past without any particular complications so leading to a false sense of security with regard to MH sensitivity. The case presented is a healthy young man with a congenital cleft lip, jaw and palette who developed a fulminant MH crisis during his ninth general anaesthesia. Post-operative research into the course of the previous anaesthesias revealed signs of MH crises which however proceeded abortively and were therefore unnoticed. In the case presented, the diagnosis was additionally complicated by the untypical course of the early symptoms. Tachycardia which in 80 % of cases is described as the first symptom of an MH crisis in onset, was at first completely absent and was only moderately pronounced in the full clinical picture of MH. On the other hand, a steady increase in body temperature, a cardinal symptom which usually appears later, was registered early. The suspected diagnosis of MH was then finally confirmed in the fourth hour after start of anaesthesia on the basis of the repeatedly increased end expiratory CO(2) levels. These could not otherwise be explained although several respiratory corrections were performed. Despite immediate MH specific therapy, the crisis developed in the following hour into the full clinical picture: maximum temperature of 41.4 degrees C, end expiratory CO(2) 100mm Hg, consumptive coagulopathy, acute renal failure and shock (systolic blood pressure < 50mm Hg, heart rate 115/minute). After 2 hours of specific intensive therapy, the patient was finally stabilized and transfer to the intensive care unit was possible. 24 hours after the event, the patient was could be extubated without any complications and 2 days later, he was transferred to the normal ward. The intra-operative diagnosis of MH was confirmed 3 days later by means of genetic analysis. Two mutations of the RYR1 gene were identified.


Asunto(s)
Anestesia General/efectos adversos , Fiebre de Origen Desconocido/etiología , Hipertermia Maligna/diagnóstico , Hipertermia Maligna/etiología , Taquicardia Ventricular/etiología , Adulto , Diagnóstico Diferencial , Fiebre de Origen Desconocido/diagnóstico , Humanos , Masculino , Hipertermia Maligna/prevención & control , Taquicardia Ventricular/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA