Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
NAR Genom Bioinform ; 5(1): lqad011, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36733401

RESUMEN

Nucleic acid fragment analysis via separation and detection are routine operations in molecular biology. However, analysis of small single-stranded nucleic acid fragments (<100nt) is challenging and mainly limited to labor-intensive polyacrylamide gel electrophoresis or high-cost capillary electrophoresis methods. Here we report an alternative method, a microfluidic chip electrophoresis system that provides a size resolution of 5nt and a detection time of one minute per sample of fluorescence-labeled DNA/RNA fragments. The feasibility of this system was evaluated by quantifying CRISPR-Cas9 cleavage efficiency and the detection resolution was evaluated by analyzing ssDNA/RNA adenylation and phosphorylation. We employed this system to study the RNA capping efficiency and double-stranded DNA unwinding efficiency in isothermal amplification as two examples for assay design and evaluation. The microfluidic chip electrophoresis system provides a rapid, sensitive, and high-throughput fluorescence fragment analysis (FFA), and can be applied for enzyme characterization, reaction optimization, and product quality control in various molecular biology processes.

2.
Lab Chip ; 9(4): 507-15, 2009 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-19190785

RESUMEN

To enable several on-chip cell handling operations in a fused-silica substrate, small shallow micropores are radially embedded in larger deeper microchannels using an adaptation of single-level isotropic wet etching. By varying the distance between features on the photolithographic mask (mask distance), we can precisely control the overlap between two etch fronts and create a zero-thickness semi-elliptical micropore (e.g. 20 microm wide, 6 microm deep). Geometrical models derived from a hemispherical etch front show that micropore width and depth can be expressed as a function of mask distance and etch depth. These models are experimentally validated at different etch depths (25.03 and 29.78 microm) and for different configurations (point-to-point and point-to-edge). Good reproducibility confirms the validity of this approach to fabricate micropores with a desired size. To illustrate the wide range of cell handling operations enabled by micropores, we present three on-chip functionalities: continuous-flow particle concentration, immobilization of single cells, and picoliter droplet generation. (1) Using pressure differentials, particles are concentrated by removing the carrier fluid successively through a series of 44 shunts terminated by 31 microm wide, 5 microm deep micropores. Theoretical values for the concentration factor determined by a flow circuit model in conjunction with finite volume modeling are experimentally validated. (2) Flowing macrophages are individually trapped in 20 microm wide, 6 microm deep micropores by hydrodynamic confinement. The translocation of transcription factor NF-kappaB into the nucleus upon lipopolysaccharide stimulation is imaged by fluorescence microscopy. (3) Picoliter-sized droplets are generated at a 20 microm wide, 7 microm deep micropore T-junction in an oil stream for the encapsulation of individual E. coli bacteria cells.


Asunto(s)
Técnicas Citológicas , Técnicas Analíticas Microfluídicas/métodos , Animales , Línea Celular , Diseño de Equipo , Escherichia coli/citología , Macrófagos/citología , Ratones , Técnicas Analíticas Microfluídicas/instrumentación , Porosidad , Reproducibilidad de los Resultados
3.
J Am Chem Soc ; 131(39): 14066-74, 2009 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-19746908

RESUMEN

Biologically functional cationic phospholipid-gold nanoplasmonic carriers have been designed to simultaneously exhibit carrier capabilities, demonstrate improved colloidal stability, and show no cytotoxicity under physiological conditions. Cargo, such as RNA, DNA, proteins, or drugs, can be adsorbed onto or incorporated into the cationic phospholipid bilayer membrane. These carriers are able to retain their unique nanoscale optical properties under physiological conditions, making them particularly useful in a wide range of imaging, therapeutic, and gene delivery applications that utilize selective nanoplasmonic properties.


Asunto(s)
Portadores de Fármacos/síntesis química , Oro/química , Membrana Dobles de Lípidos/química , ARN/metabolismo , Cationes , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Estabilidad de Medicamentos , Técnicas de Transferencia de Gen , Humanos , Luz , Nanopartículas del Metal , Fosfolípidos/química , ARN/farmacología , Dispersión de Radiación , Tensoactivos/química
4.
Anal Chem ; 80(16): 6365-72, 2008 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-18510341

RESUMEN

We have extended the principle of optical tweezers as a noninvasive technique to actively sort hydrodynamically focused cells based on their fluorescence signal in a microfluidic device. This micro fluorescence-activated cell sorter (microFACS) uses an infrared laser to laterally deflect cells into a collection channel. Green-labeled macrophages were sorted from a 40/60 ratio mixture at a throughput of 22 cells/s over 30 min achieving a 93% sorting purity and a 60% recovery yield. To rule out potential photoinduced cell damage during optical deflection, we investigated the response of mouse macrophage to brief exposures (<4 ms) of focused 1064-nm laser light (9.6 W at the sample). We found no significant difference in viability, cell proliferation, activation state, and functionality between infrared-exposed and unexposed cells. Activation state was measured by the phosphorylation of ERK and nuclear translocation of NF-kappaB, while functionality was assessed in a similar manner, but after a lipopolysaccharide challenge. To demonstrate the selective nature of optical sorting, we isolated a subpopulation of macrophages highly infected with the fluorescently labeled pathogen Francisella tularensis subsp. novicida. A total of 10,738 infected cells were sorted at a throughput of 11 cells/s with 93% purity and 39% recovery.


Asunto(s)
Separación Celular/métodos , Diagnóstico por Imagen , Francisella tularensis/efectos de la radiación , Macrófagos/efectos de la radiación , Microfluídica/métodos , Pinzas Ópticas , Animales , Núcleo Celular/metabolismo , Proliferación Celular , Supervivencia Celular , Células Cultivadas , Quinasas MAP Reguladas por Señal Extracelular/metabolismo , Citometría de Flujo , Fluorescencia , Colorantes Fluorescentes , Francisella tularensis/inmunología , Francisella tularensis/metabolismo , Proteínas Fluorescentes Verdes , Lipopolisacáridos/farmacología , Activación de Macrófagos/efectos de la radiación , Macrófagos/inmunología , Macrófagos/microbiología , Ratones , FN-kappa B/metabolismo , Fosforilación/efectos de la radiación , Transporte de Proteínas , Transducción de Señal , Tularemia/inmunología
5.
Lab Chip ; 12(16): 2823-31, 2012 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-22777012

RESUMEN

We have developed a microfluidic platform that enables, in one experiment, monitoring of signaling events spanning multiple time-scales and cellular locations through seamless integration of cell culture, stimulation and preparation with downstream analysis. A combination of two single-cell resolution techniques-on-chip multi-color flow cytometry and fluorescence imaging provides multiplexed and orthogonal data on cellular events. Automated, microfluidic operation allows quantitatively- and temporally-precise dosing leading to fine time-resolution and improved reproducibility of measurements. The platform was used to profile the toll-like receptor (TLR4) pathway in macrophages challenged with lipopolysaccharide (LPS)-beginning with TLR4 receptor activation by LPS, through intracellular MAPK signaling, RelA/p65 translocation in real time, to TNF-α cytokine production, all in one small macrophage population (< 5000 cells) while using minute reagent volume (540 nL/condition). The platform is easily adaptable to many cell types including primary cells and provides a generic platform for profiling signaling pathways.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Transducción de Señal/efectos de los fármacos , Animales , Línea Celular , Citometría de Flujo , Cinética , Lipopolisacáridos/toxicidad , Macrófagos/efectos de los fármacos , Macrófagos/inmunología , Macrófagos/metabolismo , Ratones , Proteína Quinasa 1 Activada por Mitógenos/metabolismo , Proteína Quinasa 3 Activada por Mitógenos/metabolismo , Fosforilación , Receptor Toll-Like 4/metabolismo , Receptores Toll-Like/metabolismo , Factor de Transcripción ReIA/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo
6.
Chemphyschem ; 6(5): 905-12, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15884075

RESUMEN

We have demonstrated that our photon counting histogram (PCH) model with the correction for one-photon excitation is valid at multiple bin times. The fitted apparent brightness and concentration follow the three-dimensional diffusion model. More importantly, the semi-empirical parameter, F, introduced in the PCH model for one-photon excitation to correct for the non-Gaussian shape of the observation volume, shows small variations with different bin times. These variations are consistent with the physical interpretation of F, and they do not affect the resolving power of the PCH model for one-photon excitation. Based on these findings, we extend the time-independent PCH analysis to time-dependent photon counting multiple histograms (PCMH). This model considers the effect of bin time on the PCH parameters in a way that is similar to fluorescence intensity multiple distribution analysis (FIMDA). From the same set of data, PCMH extracts time-dependent parameters (diffusion time and triplet-state relaxation time) as well as time-independent parameters (true specific brightness and true average number of molecules). Given a three- to fourfold experimental difference in molecular brightness, we find that PCMH can resolve each species in a two-species sample and extract their respective diffusion times even when fluorescence correlation spectroscopy cannot.


Asunto(s)
Biofisica/métodos , Microscopía Fluorescente/métodos , Fotones , Algoritmos , Química Física/métodos , Difusión , Colorantes Fluorescentes/farmacología , Procesamiento de Imagen Asistido por Computador , Cinética , Microscopía Confocal , Modelos Estadísticos , Distribución Normal , Espectrometría de Fluorescencia , Factores de Tiempo
7.
Proc Natl Acad Sci U S A ; 102(49): 17570-5, 2005 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-16314563

RESUMEN

We apply the photon counting histogram (PCH) model, a fluorescence technique with single-molecule sensitivity, to study pH-induced conformational changes of cytochrome c. PCH is able to distinguish different protein conformations based on the brightness of a fluorophore sensitive to its local environment. We label cytochrome c through its single free cysteine with tetramethylrhodamine-5-maleimide (TMR), a fluorophore with specific brightnesses that we associate with specific protein conformations. Ensemble measurements demonstrate two different fluorescence responses with increasing pH: (i) a decrease in fluorescence intensity caused by the alkaline transition of cytochrome c (pH 7.0-9.5), and (ii) an increase in intensity when the protein unfolds (pH 9.5-10.8). The magnitudes of these two responses depend strongly on the molar ratio of TMR used to label cytochrome c. Using PCH we determine that this effect arises from the proportion of a nonfunctional conformation in the sample, which can be differentiated from the functional conformation. We further determine the causes of each ensemble fluorescence response: (i) during the alkaline transition, the fluorophore enters a dark state and discrete conformations are observed, and (ii) as cytochrome c unfolds, the fluorophore incrementally brightens, but discrete conformations are no longer resolved. Moreover, we also show that functional TMR-cytochrome c undergoes a response of identical magnitude regardless of the proportion of nonfunctional protein in the sample. As expected for a technique with single-molecule sensitivity, we demonstrate that PCH can directly observe the most relevant conformation, unlike ensemble fluorometry.


Asunto(s)
Álcalis/química , Citocromos c/química , Microscopía Confocal/métodos , Fotones , Cisteína/química , Fluorescencia , Hemo/química , Modelos Moleculares , Estructura Terciaria de Proteína , Rodaminas , Saccharomyces cerevisiae/química , Saccharomyces cerevisiae/metabolismo , Sensibilidad y Especificidad
8.
Chemphyschem ; 5(10): 1523-31, 2004 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-15535551

RESUMEN

The photon counting histogram (PCH) analysis is a fluorescence fluctuation method that is able to characterize the brightness and concentration of different fluorescent species present in a liquid sample. We find that the PCH model using a three-dimensional Gaussian observation volume profile is inadequate for fitting experimental data obtained from a confocal setup with one-photon excitation. We propose an imoroved model, which is based on the correction to the observation volume profile for the out-of-focus emission. We demonstrate that this model is able to resolve different species present under a wide range of conditions. Attention is given to how this model allows the examination of the effects of different instrumental setups on the resolvability.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA