Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Intern Emerg Med ; 18(8): 2253-2259, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37690107

RESUMEN

The use of point-of-care ultrasound is rapidly increasing in medical practice. This study aims to evaluate the left ventricle systolic function by the bedside focus cardiac ultrasound (FoCUS). We consecutively enrolled n.59 patients of the Emergency Medicine Unit of S. Andrea Hospital. Every patient received a bedside FoCUS examination to estimate the left ventricle (LV) ejection fraction (EF); the LV EF measurements were compared with those obtained by standard echocardiography (as gold standard). The LV EF obtained by the bedside FoCUS examination and the standard echocardiography, resulted, respectively: 50.2 ± 15.1% (by the Quinones equation), 39.5 + 12.0% (by the Lvivo app) and 53.7 + 11.1% (by the standard echocardiography). The correlations between the bedside FoCUS EF measurements versus standard echocardiography were statistically significant: r = + 0.694 p < 1.9 × 10-6 (Quinones equation, Bland-Altman analysis mean = - 2.3%) and r = + 0.571 p < 0.01 (Lvivo app, Bland-Altman analysis mean = - 13.3%). In conclusion, the present study showed a high accuracy of the bedside FoCUS EF evaluations, which may support the diagnosis of the heart failure in an emergency setting without delaying. The EF measurements by the operational method are more precise than those obtained by the unselected images of the software application.


Asunto(s)
Medicina de Emergencia , Disfunción Ventricular Izquierda , Humanos , Volumen Sistólico , Ventrículos Cardíacos , Función Ventricular Izquierda , Quinonas , Reproducibilidad de los Resultados
2.
Clin Hemorheol Microcirc ; 83(2): 163-169, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36404539

RESUMEN

BACKGROUND: The use of the ultrasound (US) bedside examination is increasing for the detailed evaluation of the hemodynamic parameters, allowing the physicians to set the appropriate therapeutic strategies with greater precision. OBJECTIVE: The aim of this study is to evaluate the hemodynamic parameters (the cardiac output or CO, the central venous pressure or CVP and the systemic vascular resistance or SVR) in the patients with sepsis, by using a bedside US approach. METHODS: We consecutively enrolled n.82 patients of S.Andrea Hospital (n.47 with sepsis and n.35 without sepsis), examining the hemodynamic parameters by a bedside US evaluation. RESULTS: The incidence of sepsis was more than 50% of cases. The patients with sepsis presented higher comorbidity and polypharmacy (p < 0.01, p < 0.001), with increased creatinine (p < 0.001) and consequent esteemed glomerular filtration rate (p < 0.01), C-reactive protein (p < 0.01), SOFA (Sepsis-related Organ Failure Assessment) score (p < 1.58×10-7) and reduced SVR (p < 0.05). The SOFA score was inversely related to the SVR (p < 0.05). CONCLUSIONS: To our best knowledge, this is the first study with a bedside US protocol to measure SVR, beyond the abdominal and cardiac qualitative evaluation.


Asunto(s)
Sepsis , Humanos , Sepsis/diagnóstico , Ultrasonografía , Puntuaciones en la Disfunción de Órganos , Hemodinámica , Resistencia Vascular
3.
SN Compr Clin Med ; 5(1): 1, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36407770

RESUMEN

The use of portable ultrasound (US) devices is increasing, due to its accessibility, versatility, non-invasiveness, and its significant support in the patient management, extending the traditional physical examination through the POCUS (point-of-care ultrasound). The pocket-size or handheld ultrasound devices (HUDs) can easily perform focused exams, not aiming to substitute for the high-end US systems (gold standard), since the HUDs usually have more limited functions. The HUDs are promising tools for the diagnosis, prognosis, and monitoring of the COVID-19 infection and its related disorders. In conclusion, the routine use of HUDs may ameliorate the management of COVID-19 pandemic, according to the guidelines for the POCUS approach and the procedures for the protection of the patients and the professionals.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA