Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Opt Express ; 29(8): 12240-12251, 2021 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-33984988

RESUMEN

In a recent experimental campaign, we used laser-accelerated relativistic hot electrons to ensure heating of thin titanium wire targets up to a warm dense matter (WDM) state [EPL114, 45002 (2016)10.1209/0295-5075/114/45002]. The WDM temperature profiles along several hundred microns of the wire were inferred by using spatially resolved X-ray emission spectroscopy looking at the Ti Kα characteristic lines. A maximum temperature of ∼30 eV was reached. Our study extends this work by discussing the influence of the laser parameters on temperature profiles and the optimisation of WDM wire-based generation. The depth of wire heating may reach several hundreds of microns and it is proven to be strictly dependent on the laser intensity. At the same time, it is quantitatively demonstrated that the maximum WDM temperature doesn't appear to be sensitive to the laser intensity and mainly depends on the deposited laser energy considering ranges of 6×1018-6×1020 W/cm2 and 50-200 J.

2.
Opt Express ; 25(3): 1958-1972, 2017 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-29519045

RESUMEN

By analyzing profiles of experimental x-ray spectral lines of Si XIV and Al XIII, we found that both Langmuir and ion acoustic waves developed in plasmas produced via irradiation of thin Si foils by relativistic laser pulses (intensities ~1021 W/cm2). We prove that these waves are due to the parametric decay instability (PDI). This is the first time that the PDI-induced ion acoustic turbulence was discovered by the x-ray spectroscopy in laser-produced plasmas. These conclusions are also supported by PIC simulations. Our results can be used for laboratory modeling of physical processes in astrophysical objects and a better understanding of intense laser-plasma interactions.

3.
Rev Sci Instrum ; 95(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578244

RESUMEN

An X-pinch load driven by an intense current pulse (>100 kA in ∼100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1-10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. To study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1-10×), this diagnostic achieves a spatial resolution of ∼35 µm, which is useful for resolving the ∼100-µm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100-200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈50±25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150±75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75±50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

4.
Phys Rev Lett ; 110(12): 125001, 2013 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-25166812

RESUMEN

In high-spectral resolution experiments with the petawatt Vulcan laser, strong x-ray radiation of KK hollow atoms (atoms without n = 1 electrons) from thin Al foils was observed at pulse intensities of 3 × 10(20) W/cm(2). The observations of spectra from these exotic states of matter are supported by detailed kinetics calculations, and are consistent with a picture in which an intense polychromatic x-ray field, formed from Thomson scattering and bremsstrahlung in the electrostatic fields at the target surface, drives the KK hollow atom production. We estimate that this x-ray field has an intensity of >5 × 10(18) W/cm(2) and is in the 3 keV range.

5.
Rev Sci Instrum ; 94(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38065178

RESUMEN

In this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9-1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ∼30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

6.
Sci Rep ; 13(1): 20681, 2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38001120

RESUMEN

Shock Ignition is a two-step scheme to reach Inertial Confinement Fusion, where the precompressed fuel capsule is ignited by a strong shock driven by a laser pulse at an intensity in the order of [Formula: see text] W/cm[Formula: see text]. In this report we describe the results of an experiment carried out at PALS laser facility designed to investigate the origin of hot electrons in laser-plasma interaction at intensities and plasma temperatures expected for Shock Ignition. A detailed time- and spectrally-resolved characterization of Stimulated Raman Scattering and Two Plasmon Decay instabilities, as well as of the generated hot electrons, suggest that Stimulated Raman Scattering is the dominant source of hot electrons via the damping of daughter plasma waves. The temperature dependence of laser plasma instabilities was also investigated, enabled by the use of different ablator materials, suggesting that Two Plasmon Decay is damped at earlier times for higher plasma temperatures, accompanied by an earlier ignition of SRS. The identification of the predominant hot electron source and the effect of plasma temperature on laser plasma interaction, here investigated, are extremely useful for developing the mitigation strategies for reducing the impact of hot electrons on the fuel ignition.

7.
Phys Rev Lett ; 108(19): 195004, 2012 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-23003052

RESUMEN

We report the experimental results of a turbulent electric field driven by Kelvin-Helmholtz instability associated with laser produced collisionless shock waves. By irradiating an aluminum double plane target with a high-power laser, counterstreaming plasma flows are generated. As the consequence of the two plasma interactions, two shock waves and the contact surface are excited. The shock electric field and transverse modulation of the contact surface are observed by proton radiography. Performing hydrodynamic simulations, we reproduce the time evolutions of the reverse shocks and the transverse modulation driven by Kelvin-Helmholtz instability.

8.
Phys Rev Lett ; 109(15): 155002, 2012 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-23102317

RESUMEN

Using solid, machined X-pinch targets driven by currents rising from 0 to 5-6 MA in 60 ns, we observed bright spots of 5-9-keV continuum radiation from 5±2-µm diameter regions. The >6-keV radiation is emitted in about 0.4 ns, and the bright spots are roughly 75 times brighter than the bright spots measured at 1 MA. A total x-ray power of 10 TW peak and yields of 165±20 kJ were emitted from a 3-mm height. The 3-5-keV continuum radiation had a 50-90-GW peak power and 0.15-0.35-kJ yield. The continuum is plausibly from a 1275±75-eV blackbody or alternatively from a 3500±500-eV bremsstrahlung source.

9.
Phys Rev Lett ; 106(13): 134801, 2011 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-21517389

RESUMEN

We report on the first generation of 5.5-7.5 MeV protons by a moderate-intensity short-pulse laser (∼5×10(17) W/cm(2), 40 fsec) interacting with frozen H(2)O nanometer-size structure droplets (snow nanowires) deposited on a sapphire substrate. In this setup, the laser intensity is locally enhanced by the snow nanowire, leading to high spatial gradients. Accordingly, the nanoplasma is subject to enhanced ponderomotive potential, and confined charge separation is obtained. Electrostatic fields of extremely high intensities are produced over the short scale length, and protons are accelerated to MeV-level energies.

10.
Rev Sci Instrum ; 92(12): 123505, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34972471

RESUMEN

This paper demonstrates the possibility of using a new configuration of the hybrid X-pinch to produce a set of spatially and temporarily separate x-ray bursts that could be used for the radiography of dynamic events. To achieve this, a longer than normal wire is placed between the conical electrodes of the hybrid X-pinch, and a set of small spacers (fishing weights) is placed along the wire. Each subsection of the wire then acts as a unique X-pinch, producing its own radiation burst from a small (∼3 µm) spot. The timing between bursts is 20-50 ns, and each is <2 ns in duration. For comparison, if a longer wire is simply employed without spacers, hotspots of radiation occur in random positions and the time between any two bursts does not exceed 20 ns. Examples of two and three frame point-projection radiography of solid-state and plasma test objects are given.

11.
Phys Rev E ; 102(6-1): 063208, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33465966

RESUMEN

K-shell x-ray spectra from Al wire hybrid X pinches have been studied using an x-ray streak camera with better than 0.1-ns time resolution together with a Focusing Spectrograph with Spatial Resolution (FSSR) spectrograph. High-intensity radiation with a continuumlike spectrum was observed in the subnanosecond initial phase of the x-ray pulse generated by the hybrid X pinch (HXP). The absence of spectral lines in this phase and the extremely small x-ray source size indicates the importance of radiative processes in the final phase implosion dynamics. Plasma parameters in the following phases of the HXP were determined from analysis of the line intensities. Point-projection radiography together with a slit-step wedge camera and an FSSR spectrograph without time resolution were used to show the number of radiation sources, and to give information on the time-integrated photon energy spectrum.

12.
Phys Rev E ; 101(4-1): 043208, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32422777

RESUMEN

The formation of high energy density matter occurs in inertial confinement fusion, astrophysical, and geophysical systems. In this context, it is important to couple as much energy as possible into a target while maintaining high density. A recent experimental campaign, using buried layer (or "sandwich" type) targets and the ultrahigh laser contrast Vulcan petawatt laser facility, resulted in 500 Mbar pressures in solid density plasmas (which corresponds to about 4.6×10^{7}J/cm^{3} energy density). The densities and temperatures of the generated plasma were measured based on the analysis of x-ray spectral line profiles and relative intensities.

13.
Phys Rev E Stat Nonlin Soft Matter Phys ; 79(3 Pt 2): 036407, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19392064

RESUMEN

A plasma model of relaxation of a medium in heavy-ion tracks in condensed matter is proposed. The model is based on three assumptions: the Maxwell distribution of plasma electrons, localization of plasma inside the track nanochannel, and constant values of the plasma electron density and temperature during the x-ray irradiation. The model of multiple ionization of target atoms by a fast projectile ion is used to determine the initial conditions. An analysis of the results of the calculations performed makes it possible to define when the atomic relaxation model is a very rough approximation and the plasma relaxation model must be used. It is demonstrated that the plasma relaxation model adequately describes the x-ray spectra observed upon interaction of a fast ion with condensed target. The comparison with the experimental data justifies the reliability of the plasma relaxation model. Preassumptions of plasma relaxation model are validated by the molecular-dynamics simulation. An x-ray spectral method based on the plasma relaxation model is proposed for diagnostics of the plasma in fast ion tracks. The results obtained can be useful in examining the initial stage of defect formation in solids under irradiation with single fast heavy ions.

14.
Rev Sci Instrum ; 79(1): 013106, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18248021

RESUMEN

A new, wide spectral bandwidth x-ray spectrograph, the wide-bandwidth focusing spectrograph with spatial resolution (WB-FSSR), based on spherically bent mica crystals, is described. The wide bandwidth is achieved by combining three crystals to form a large aperture dispersive element. Since the WB-FSSR covers a wide spectral band, it is very convenient for application as a routine diagnostic tool in experiments in which the desired spectral coverage is different from one test to the next. The WB-FSSR has been tested in imploding wire-array experiments on a 1 MA pulsed power machine, and x-ray spectra were recorded in the 1-20 A spectral band using different orders of mica crystal reflection. Using a two mirror-symmetrically placed WB-FSSR configuration, it was also possible to distinguish between a real spectral shift and a shift of recorded spectral lines caused by the spatial distribution of the radiating plasma. A spectral resolution of about 2000 was demonstrated and a spatial resolution of approximately 100 microm was achieved in the spectral band of 5-10 A in second order of mica reflection. A simple method of numerical analysis of spectrograph capability is proposed.

15.
Rev Sci Instrum ; 89(10): 10G127, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399908

RESUMEN

Talbot-Lau x-ray interferometers can map electron density gradients in High Energy Density (HED) samples. In the deflectometer configuration, it can provide refraction, attenuation, elemental composition, and scatter information from a single image. X-ray backlighters in Talbot-Lau deflectometry must meet specific requirements regarding source size and x-ray spectra, amongst others, to accurately diagnose a wide range of HED experiments. 8 keV sources produced in the high-power laser and pulsed power environment were evaluated as x-ray backlighters for Talbot-Lau x-ray deflectometry. In high-power laser experiments, K-shell emission was produced by irradiating copper targets (500 × 500 × 12.5 µm3 foils, 20 µm diameter wire, and >10 µm diameter spheres) with 30 J, 8-30 ps laser pulses and a 25 µm copper wire with a 60 J, 10 ps laser pulse. In the pulsed power environment, single (2 × 40 µm) and double (4 × 25 µm) copper x-pinches were driven at ∼1 kA/ns. Moiré fringe formation was demonstrated for all x-ray sources explored, and detector performance was evaluated for x-ray films, x-ray CCDs, and imaging plates in context of spatial resolution, x-ray emission, and fringe contrast.

16.
Sci Rep ; 8(1): 16407, 2018 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-30401885

RESUMEN

High resolution X-ray imaging is crucial for many high energy density physics (HEDP) experiments. Recently developed techniques to improve resolution have, however, come at the cost of a decreased field of view. In this paper, an innovative experimental detector for X-ray imaging in the context of HEDP experiments with high spatial resolution, as well as a large field of view, is presented. The platform is based on coupling an X-ray backligther source with a Lithium Fluoride detector, characterized by its large dynamic range. A spatial resolution of 2 µm over a field of view greater than 2 mm2 is reported. The platform was benchmarked with both an X-ray free electron laser (XFEL) and an X-ray source produced by a short pulse laser. First, using a non-coherent short pulse laser-produced backlighter, reduced penumbra blurring, as a result of the large size of the X-ray source, is shown. Secondly, we demonstrate phase contrast imaging with a fully coherent monochromatic XFEL beam. Modeling of the absorption and phase contrast transmission of X-ray radiation passing through various targets is presented.

17.
Rev Sci Instrum ; 88(11): 113502, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29195347

RESUMEN

Broadband, high resolution X-pinch radiography has been demonstrated as a method to view the instability induced small scale structure that develops in near solid density regions of both insulated and non-insulated cylindrical metallic liners. In experiments carried out on a 1-1.2 MA 100-200 ns rise time pulsed power generator, µm scale features were imaged in initially 16 µm thick Al foil cylindrical liners. Better resolution and contrast were obtained using an X-ray sensitive film than with image plate detectors because of the properties of the X-pinch X-ray source. We also discuss configuration variations that were made to the simple cylindrical liner geometry that appeared to maintain validity of the small-scale structure measurements while improving measurement quality.

18.
Rev Sci Instrum ; 87(10): 107101, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27802769

RESUMEN

The elliptical spectrometer described by Cahill et al. [Rev. Sci. Instrum. 85, 103114 (2014)] is designed to enable absorption X-ray spectroscopy under circumstances in which the object plasma is, itself, a relatively bright X-ray emitter. An implementation of this design was developed using a doubly curved mica crystal for X-ray dispersion. The geometry of the spectrometer was verified by ray tracing calculations assuming Bragg reflection from mica in the second order. Control of X-ray reflections from other orders was an anticipated challenge and has been attempted by means of filtering and control of the source spectrum. These efforts have been found to be insufficient to allow the spectrometer to operate as designed because of the strong fifth order reflection of source radiation by the mica crystal. Potential solutions are presented that may enable a successful implementation of this novel crystal spectrometer design.

19.
Rev Sci Instrum ; 87(11): 11D407, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910685

RESUMEN

We have shown that Zeeman splitting of the sodium (Na) D-lines at 5890 and 5896 Å can be used to measure the magnetic field (B-field) produced in high current pulsed power experiments. We have measured the B-field next to a return current conductor in a hybrid X-pinch experiment near a peak current of about 500 kA. Na is deposited on the conductor and then is desorbed and excited by radiation from the hybrid X-pinch. The D-line emission spectrum implies B-fields of about 20 T with a return current post of 4 mm diameter or up to 120 T with a return current wire of 0.455 mm diameter. These measurements were consistent or lower than the expected B-field, thereby showing that basic Zeeman splitting can be used to measure the B-field in a pulsed-power-driven high-energy-density (HED) plasma experiment. We hope to extend these measurement techniques using suitable ionized species to measurements within HED plasmas.

20.
Rev Sci Instrum ; 87(10): 103506, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27802687

RESUMEN

We have shown that the Zeeman splitting of the sodium (Na) D-lines at 5890 Å and 5896 Å can be used to measure the magnetic field produced by the current flowing in an exploding wire prior to wire explosion. After wire explosion, the lines in question are either not visible in the strong continuum from the exploding wire plasma, or too broad to measure the magnetic field by methods discussed in this paper. We have determined magnetic fields in the range 10-20 T, which lies between the small field and Paschen-Back regimes for the Na D-lines, over a period of about 70 ns on a 10 kA peak current machine. The Na source is evaporated drops of water with a 0.171 M NaCl solution deposited on the wire. The Na desorbs from the wire as it heats up, and the excited vapor atoms are seen in emission lines. The measured magnetic field, determined by the Zeeman splitting of these emission lines, estimates the average radial location of the emitting Na vapor as a function of time under the assumption the current flows only in the wire during the time of the measurement.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA