Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 357
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lancet ; 402(10416): 1979-1990, 2023 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-37898137

RESUMEN

BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Sirolimus/uso terapéutico , Everolimus/uso terapéutico , Estudios de Seguimiento , Infarto del Miocardio con Elevación del ST/cirugía , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Polímeros , Teorema de Bayes , Método Simple Ciego , Estudios Prospectivos , Resultado del Tratamiento , Implantes Absorbibles , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/métodos
2.
N Engl J Med ; 385(23): 2150-2160, 2021 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-34449183

RESUMEN

BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).


Asunto(s)
4-Hidroxicumarinas/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Inhibidores del Factor Xa/uso terapéutico , Piridinas/uso terapéutico , Tiazoles/uso terapéutico , Reemplazo de la Válvula Aórtica Transcatéter , Vitamina K/antagonistas & inhibidores , 4-Hidroxicumarinas/efectos adversos , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Inhibidores del Factor Xa/efectos adversos , Femenino , Hemorragia Gastrointestinal/inducido químicamente , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Mortalidad , Fenindiona/análogos & derivados , Fenindiona/uso terapéutico , Complicaciones Posoperatorias/prevención & control , Piridinas/efectos adversos , Tiazoles/efectos adversos , Tromboembolia/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
3.
Curr Cardiol Rep ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39073506

RESUMEN

BACKGROUND: Obesity paradox in cardiovascular risk prediction has gained increasing attention in recent years. We aimed to investigate the impact of BMI on mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a multi-center retrospective analysis of patients with severe aortic stenosis undergoing TAVR. Patients were categorized into: Underweight (BMI < 18.5), normal weight (18.5 ≤ BMI < 25), overweight (25 ≤ BMI < 30) and obese (BMI ≥ 30). Multivariate cox-proportional hazard model was used to compare all-cause mortality. RESULTS: Total of 6688 patients included (175 underweight, 2252 normal weight, 2368 overweight and 1893 with obesity). Mean age of patients was 81 ± 8 years with 55% males. Patients with obesity had higher prevalence of comorbidities but a lower overall STS score. Mortality at 30-days post-TAVR was lower in the obese population compared to underweight, normal weight, and overweight patients (1.6% vs. 6.9%, 3.6%, and 2.8%, respectively, p < 0.001). Similarly, 3-year mortality was lowest in patients with obesity (17.1% vs. 28.9%, 24.5% and 18.6%, respectively, p < 0.001). On multivariate analysis, long term all-cause mortality at 3-years remained significantly lower in patients with obesity compared to underweight (HR 1.74, 95% CI: 1.30-2.40, p < 0.001) and normal weight (HR: 1.41, 95% CI:1.21-1.63, p < 0.001) but not in overweight patients (HR: 1.10, 95% CI:0.94-1.28, p = 0.240). CONCLUSION: In conclusion, patients with obesity have improved short and long term mortality following TAVR with an observed progressive increase in mortality with lower BMI ranges.

4.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-36883599

RESUMEN

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía
5.
Radiology ; 309(3): e230425, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38085082

RESUMEN

Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.


Asunto(s)
Neuropatías Amiloides Familiares , Amiloidosis , Estenosis de la Válvula Aórtica , Cardiomiopatías , Humanos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Prealbúmina , Estudios Prospectivos , Amiloidosis/complicaciones , Tomografía Computarizada por Rayos X , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/diagnóstico por imagen
6.
Am Heart J ; 261: 51-54, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37011854

RESUMEN

The aim of this retrospective analysis was to investigate the prevalence and prognostic importance of incidental malignancy detected during pre-TAVI computed tomography. Among 579 patients, CT-work-up for TAVI exposed previously undetected malignancy in 4.5% of patients. TAVI patients with a new malignancy had a 2.9-fold increased risk of death at 1 year, and a 16 month shorter mean survival time compared to patients with no malignancy.


Asunto(s)
Estenosis de la Válvula Aórtica , Neoplasias , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Estudios Longitudinales , Estenosis de la Válvula Aórtica/cirugía , Estudios de Cohortes
7.
Am Heart J ; 263: 73-84, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37192697

RESUMEN

BACKGROUND: Whether ultrathin-strut stents are particularly beneficial for lesions requiring implantation of more than 1 stent is unknown. METHODS: In a post-hoc lesion-level analysis of 2 randomized trials comparing ultrathin-strut biodegradable polymer Sirolimus-eluting stents (BP-SES) vs thin-strut durable polymer Everolimus-eluting stents (DP-EES), lesions were stratified into multistent lesions (MSL) vs single-stent lesions (SSL). The primary endpoint was target lesion failure (TLF), a composite of lesion-related unclear/cardiac death, myocardial infarction (MI), or revascularization, at 24 months. RESULTS: Among 5328 lesions in 3397 patients, 1492 (28%) were MSL (722 with BP-SES, 770 with DP-EES). At 2 years, TLF occurred in 63 lesions (8.9%) treated with BP-SES and 60 lesions (7.9%) treated with DP-EES in the MSL-group (subdistibution hazard ratio [SHR], 1.13; 95% CI, 0.77-1.64; P = .53), and in 121 (6.4%) and 136 (7.4%) lesions treated with BP-SES and DP-EES respectively (SHR, 0.86; 95% CI, 0.62-1.18; P = .35) in the SSL-group (P for interaction = .241). While the rates of lesion-related MI or revascularization were significantly lower in SSL treated with BP-SES as compared to DP-EES (3.5% vs 5.2%; SHR, 0.67; 95% CI 0.46-0.97; P = .036), no significant difference was observed in MSL (7.1% vs 5.4%; SHR, 1.31; 95% CI 0.85-2.03; P = .216) with significant interaction between groups (P for interaction = .014). CONCLUSIONS: Rates of TLF are similar between ultrathin-strut BP-SES and thin-strut DP-EES in MSL and SSL. The use of ultrathin-strut BP-SES vs thin-strut DP-EES did not prove to be particularly beneficial for the treatment of multistent lesions. TRIAL REGISTRATION: Post-hoc analysis from the BIOSCIENCE (NCT01443104) and BIOSTEMI (NCT02579031) trials.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Everolimus/farmacología , Infarto del Miocardio/epidemiología , Polímeros , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Sirolimus , Resultado del Tratamiento
8.
Am Heart J ; 256: 139-147, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36410441

RESUMEN

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/métodos
9.
Catheter Cardiovasc Interv ; 101(1): 199-208, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36453455

RESUMEN

BACKGROUND: Elliptical shape of the aortic annulus has been associated with an increased risk of device failure after transcatheter aortic valve implantation (TAVI) compared with a circular annular shape. AIMS: To assess the impact of annulus ellipticity on procedural outcomes and device performance in patients undergoing TAVI. METHODS: In a prospective TAVI registry, aortic annulus ellipticity was assessed by preprocedural multidetector computed tomography. The annulus ratios, defined by the ratio of minimum and maximum annulus diameters measured in a transverse double oblique plane, were split into tertiles for comparisons between groups. RESULTS: A total of 1732 patients undergoing TAVI between August 2007 and June 2020 were included in the present analysis. Patients in the tertile with the most elliptical shape of the annulus were more likely to be female (59.7% vs. 47.9%; p < 0.001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (5.4 ± 3.8 vs. 4.8 ± 3.5; p = 0.002). There were no significant differences in the rate of technical success (95.3% vs. 96.5%; p = 0.235), device success (83.6% vs. 86.5%; p = 0.118) and intended valve performance (90.7% vs. 91.7; p = 0.503) between patients in the most elliptical tertile and the rest. However, valve dislocation/embolization occurred more frequently in patients with elliptical as compared to circular annular shape (2.6% vs. 1.2%; p = 0.046). CONCLUSIONS: Ellipticity of the aortic annulus does not affect procedural and device outcomes in patients undergoing TAVI irrespective of transcatheter heart valve design and generation. https:www.//clinicaltrials.gov. NCT01368250.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada Multidetector/métodos , Estudios Prospectivos , Resultado del Tratamiento
10.
Catheter Cardiovasc Interv ; 101(4): 687-700, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36807456

RESUMEN

BACKGROUND: Ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) are superior to thin-strut durable polymer everolimus-eluting stents (DP-EES) with respect to target lesion failure (TLF) at 2 years among patients with ST-segment elevation myocardial infarction (STEMI). We sought to determine the impact of primary percutaneous coronary intervention (pPCI) complexity on long-term clinical outcomes with BP-SES versus DP-EES in STEMI patients. METHODS: We performed a post hoc subgroup analysis from the BIOSTEMI (NCT02579031) randomized trial, which included individual data from 407 STEMI patients enrolled in the BIOSCIENCE trial (NCT01443104). STEMI patients were randomly assigned to treatment with ultrathin-strut BP-SES or thin-strut DP-EES, and further categorized into those undergoing complex versus noncomplex pPCI. Complex pPCI was defined by the presence of ≥1 of the following criteria: 3 vessel treatment, ≥3 stents implanted, ≥3 lesions treated, bifurcation lesion with ≥2 stents implanted, total stent length ≥60 mm, and/or chronic total occlusion treatment. The primary endpoint was TLF, a composite of cardiac death, target-vessel myocardial reinfarction, or clinically indicated target lesion revascularization, within 2 years. RESULTS: Among a total of 1707 STEMI patients, 421 (24.7%) underwent complex pPCI. Baseline characteristics were similar between groups. At 2 years, TLF occurred in 14 patients (7.1%) treated with BP-SES and 25 patients (11.6%) treated with DP-EES (hazard ratio [HR]: 0.62; 95% confidence interval [CI]: 0.32-1.19; p = 0.15) in the complex pPCI group, and in 28 patients (4.4%) treated with BP-SES and 49 patients (8.2%) treated with DP-EES (HR: 0.54; 95% CI: 0.34-0.86; p = 0.008; p for interaction = 0.74) in the noncomplex pPCI group. Individual TLF components and stent thrombosis rates did not significantly differ between groups. CONCLUSION: In a post hoc subgroup analysis from the BIOSTEMI randomized trial, ultrathin-strut BP-SES were superior to thin-strut DP-EES with respect to TLF at 2 years among STEMI patients undergoing both complex and noncomplex pPCI.


Asunto(s)
Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Implantes Absorbibles , Stents Liberadores de Fármacos , Everolimus/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diseño de Prótesis , Sirolimus/efectos adversos , Infarto del Miocardio con Elevación del ST/etiología , Resultado del Tratamiento , Stents
11.
Am Heart J ; 244: 94-106, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34788603

RESUMEN

BACKGROUND: Ascending aortic root anatomy is routinely evaluated on pre-procedural multi-detector computed tomography (MDCT). However, its clinical significance has not been adequately studied. We aimed to investigate the impact of the sinus of Valsalva (SOV) dimension on clinical outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective TAVI registry, we retrospectively assessed SOV dimensions by pre-procedural MDCT. Patients were stratified according to tertiles of SOV diameter indexed to body surface area (SOVi). The primary endpoint was all-cause mortality at 1 year. RESULTS: Among 2066 consecutive patients undergoing TAVI between August 2007 and June 2018, 1554 patients were eligible for the present analysis. Patients in the large SOVi group were older (83 ± 6 vs 82 ± 6 vs 81 ± 6; P < .001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (6.3 ± 3.8 vs 5.1 ± 3.1 vs 4.9 ± 3.5; P < .001) than those in the other groups. Patients in the large SOVi group had a higher incidence of moderate or severe paravalvular regurgitation (11.9% vs 4.5% vs 3.5%; P < .001). At 1 year, a large SOVi was independently associated with an increased risk of mortality (HR: 1.62; 95% CI: 1.19-2.21; P = .002) and major or life-threatening bleeding (HR: 1.30; 95% CI: 1.02-1.65; P = .035). CONCLUSIONS: Dilatation of the aortic root at the SOV was associated with adverse outcomes after TAVI. The assessment of the aortic root should be integrated into the risk stratification system in patients undergoing TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Seno Aórtico , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Seno Aórtico/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 99(6): 1908-1917, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35170846

RESUMEN

BACKGROUND: Increased left ventricular afterload resulting from severe aortic stenosis (AS) leads to progressive cardiac remodeling. Left atrial enlargement (LAE) is an early manifestation in a series of maladaptive changes and may affect clinical outcomes after valvular replacement therapy. The aim of this study is to determine the impact of LAE on clinical outcomes in symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective single-center TAVI registry, we analyzed LA dimensions measured by echocardiography before intervention. Patients with atrial fibrillation or concomitant mitral valve disease were excluded. LAE was defined as indexed LA volume >34 ml/m2 . The primary endpoint was cardiovascular death (CVD) at 1 year. RESULTS: Among 1663 patients undergoing TAVI between August 2007 and December 2016, 768 (46.2%) were eligible for the present analysis and 486 patients had LAE. The prevalence of LAE was higher in males (68.3%) as compared to females (58.8%). Patients with LAE were older (82.3 ± 6.7 years vs. 80.0 ± 6.4 years) and had a higher STS-PROM score (6.1 ± 4.7% vs. 4.7 ± 2.9%). After adjustment, patients with LAE had an increased risk of CVD at 1-year compared to patients with normal LA dimensions (49 [10.4%] vs. 8 [2.9%]; HRadj , 3.52; 95% CI, 1.66-7.44)]. In multivariable analysis, LAE was independently associated with an increased risk of CVD at 1-year (HRadj , 3.52; 95% CI, 1.66-7.44). CONCLUSIONS: LAE secondary to AS was documented in a significant proportion of patients undergoing TAVI and was associated with a more than threefold increased risk of CVD at 1-year.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
13.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-35436856

RESUMEN

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
14.
Cardiol Young ; 32(7): 1151-1153, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34732274

RESUMEN

BACKGROUND: The present study aimed to quantify the burden of structural heart disease in Nepali children. METHODS: We performed a school-based cross-sectional echocardiographic screening study with cluster random sampling among children 5-16 years of age. RESULTS: Between December 2012 and January 2019, 6573 children (mean age 10.6 ± 2.9 years) from 41 randomly selected schools underwent echocardiographic screening. Structural heart disease was detected in 14.0 per 1000 children (95% CI 11.3-17.1) and was congenital in 3.3 per 1000 (95% CI 2.1-5.1) and rheumatic in 10.6 per 1000 (95% CI 8.3-13.4). Rates of rheumatic heart disease were higher among children attending public as compared to private schools (OR 2.8, 95% CI 1.6-5.2, p = 0.0001). CONCLUSION: Rheumatic heart disease accounted for three out of four cases of structural heart disease and was more common among children attending public as compared to private schools.


Asunto(s)
Cardiopatía Reumática , Adolescente , Niño , Estudios Transversales , Ecocardiografía , Humanos , Tamizaje Masivo , Prevalencia , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/epidemiología , Instituciones Académicas
15.
Heart Lung Circ ; 31(9): 1203-1218, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35680498

RESUMEN

BACKGROUND: To tailor cardiovascular interventions, the use of three-dimensional (3D), patient-specific phantoms (3DPSP) encompasses patient education, training, simulation, procedure planning, and outcome-prediction. AIM: This systematic review and meta-analysis aims to investigate the current and future perspective of 3D printing for cardiovascular interventions. METHODS: We systematically screened articles on Medline and EMBASE reporting the prospective use of 3DPSP in cardiovascular interventions by using combined search terms. Studies that compared intervention time depending on 3DPSP utilisation were included into a meta-analysis. RESULTS: We identified 107 studies that prospectively investigated a total of 814 3DPSP in cardiovascular interventions. Most common settings were congenital heart disease (CHD) (38 articles, 6 comparative studies), left atrial appendage (LAA) occlusion (11 articles, 5 comparative, 1 randomised controlled trial [RCT]), and aortic disease (10 articles). All authors described 3DPSP as helpful in assessing complex anatomic conditions, whereas poor tissue mimicry and the non-consideration of physiological properties were cited as limitations. Compared to controls, meta-analysis of six studies showed a significant reduction of intervention time in LAA occlusion (n=3 studies), and surgery due to CHD (n=3) if 3DPSPs were used (Cohen's d=0.54; 95% confidence interval 0.13 to 0.95; p=0.001), however heterogeneity across studies should be taken into account. CONCLUSIONS: 3DPSP are helpful to plan, train, and guide interventions in patients with complex cardiovascular anatomy. Benefits for patients include reduced intervention time with the potential for lower radiation exposure and shorter mechanical ventilation times. More evidence and RCTs including clinical endpoints are needed to warrant adoption of 3DPSP into routine clinical practice.


Asunto(s)
Cardiopatías Congénitas , Impresión Tridimensional , Diagnóstico por Imagen , Humanos , Pronóstico
16.
Circulation ; 141(21): 1670-1680, 2020 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-32223336

RESUMEN

BACKGROUND: Nonrheumatic valvular diseases are common; however, no studies have estimated their global or national burden. As part of the Global Burden of Disease Study 2017, mortality, prevalence, and disability-adjusted life-years (DALYs) for calcific aortic valve disease (CAVD), degenerative mitral valve disease, and other nonrheumatic valvular diseases were estimated for 195 countries and territories from 1990 to 2017. METHODS: Vital registration data, epidemiologic survey data, and administrative hospital data were used to estimate disease burden using the Global Burden of Disease Study modeling framework, which ensures comparability across locations. Geospatial statistical methods were used to estimate disease for all countries, because data on nonrheumatic valvular diseases are extremely limited for some regions of the world, such as Sub-Saharan Africa and South Asia. Results accounted for estimated level of disease severity as well as the estimated availability of valve repair or replacement procedures. DALYs and other measures of health-related burden were generated for both sexes and each 5-year age group, location, and year from 1990 to 2017. RESULTS: Globally, CAVD and degenerative mitral valve disease caused 102 700 (95% uncertainty interval [UI], 82 700-107 900) and 35 700 (95% UI, 30 500-42 500) deaths, and 12.6 million (95% UI, 11.4 million-13.8 million) and 18.1 million (95% UI, 17.6 million-18.6 million) prevalent cases existed in 2017, respectively. A total of 2.5 million (95% UI, 2.3 million-2.8 million) DALYs were estimated as caused by nonrheumatic valvular diseases globally, representing 0.10% (95% UI, 0.09%-0.11%) of total lost health from all diseases in 2017. The number of DALYs increased for CAVD and degenerative mitral valve disease between 1990 and 2017 by 101% (95% UI, 79%-117%) and 35% (95% UI, 23%-47%), respectively. There is significant geographic variation in the prevalence, mortality rate, and overall burden of these diseases, with highest age-standardized DALY rates of CAVD estimated for high-income countries. CONCLUSIONS: These global and national estimates demonstrate that CAVD and degenerative mitral valve disease are important causes of disease burden among older adults. Efforts to clarify modifiable risk factors and improve access to valve interventions are necessary if progress is to be made toward reducing, and eventually eliminating, the burden of these highly treatable diseases.


Asunto(s)
Insuficiencia de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/epidemiología , Válvula Aórtica/patología , Calcinosis/epidemiología , Salud Global , Insuficiencia de la Válvula Mitral/epidemiología , Prolapso de la Válvula Mitral/epidemiología , Distribución por Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/cirugía , Costo de Enfermedad , Femenino , Disparidades en el Estado de Salud , Disparidades en Atención de Salud , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/mortalidad , Prolapso de la Válvula Mitral/cirugía , Prevalencia , Calidad de Vida , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
17.
Am Heart J ; 235: 140-148, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33609498

RESUMEN

BACKGROUND: Newest generation drug-eluting stents combine biodegradable polymers with ultrathin stent platforms in order to minimize vessel injury and inflammatory response. Evidence from randomized controlled trials suggested that differences in stent design translate into differences in clinical outcome. The aim of the present study was to evaluate the safety and efficacy of ultrathin strut, biodegradable polymer sirolimus eluting stents (BP SES) compared with thin strut, durable polymer everolimus-eluting stents (DP EES) among patients undergoing percutaneous coronary intervention (PCI). METHODS: We pooled individual participant data from 5 randomized trials (NCT01356888, NCT01939249, NCT02389946, NCT01443104, NCT02579031) including a total of 5,780 patients, and performed a one-stage meta-analysis using a mixed effects Cox regression model. RESULTS: At a median duration of follow-up of 739 days (interquartile range 365-1,806 days), target-lesion failure occurred in 337 (10.3%) and 304 (12.2%) patients treated with BP SES and DP EES (HR 0.86, 95%CI 0.71-1.06, P = .16). There were no significant differences between BP SES and DP EES with regards to cardiac death (111 (3.4%) vs 102 (4.1%); HR 1.05, 95%CI 0.80-1.37, P = .73), target-vessel myocardial infarction (136 (4.1%) vs 126 (5.0%), HR 0.79, 95%CI 0.62-1.01, P = .061), and clinically-driven target-lesion revascularization (163 (5.0%) vs 147 (5.9%); HR 0.94, 95%CI 0.75-1.18, P = .61). The effect was consistent across major subgroups. In a landmark analysis, there was no significant interaction between treatment effect and timing of events. CONCLUSIONS: In this patient-level meta-analysis of 5 randomized controlled trials, BP SES were associated with a similar risk of target-lesion failure compared with DP EES among patients undergoing PCI. STUDY REGISTRATION: PROSPERO registry (CRD42018109098).


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Everolimus/farmacología , Intervención Coronaria Percutánea/métodos , Polímeros , Sirolimus/farmacología , Stents Liberadores de Fármacos , Humanos , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
18.
Catheter Cardiovasc Interv ; 98(5): E768-E779, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33857355

RESUMEN

OBJECTIVES: To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. METHODS: In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV-oversizing and THV-undersizing. The primary endpoint was a composite of all-cause death and unplanned repeat intervention at 1 year. RESULTS: Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HRadj 1.35, 95%CI 0.87-2.09), and in 17.4% of patients with suboptimal sizing (HRadj 1.42, 95%CI 1.01-1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HRadj 1.98, 95%CI 1.36-2.87). CONCLUSION: Suboptimal TAVI prosthesis sizing is associated with an increased risk of all-cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 98(7): 1404-1412, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34406713

RESUMEN

OBJECTIVES: To investigate whether the integrative echocardiographic criteria used in the cardiovascular outcomes assessment of the mitraclip percutaneous therapy (COAPT) for heart failure patients with functional mitral regurgitation study predict outcomes after edge-to-edge trancatheter mitral valve repair (TMVr) for the treatment of secondary mitral regurgitation (SMR). BACKGROUND: Two randomized controlled trials comparing TMVr to medical treatment reported conflicting findings. Differences in patient selection criteria may have contributed to these diverging results. METHODS: Patients undergoing TMVr were stratified following the integrative COAPT echocardiographic criteria in noneligible and eligible patients who were further classified into three tiers according to effective regurgitant orifice (EROA) (Tier 1: EROA ≥ 0.3cm2 ; Tier 2: EROA 0.2cm2 and 0.29cm2 ; Tier 3: EROA<0.2cm2 ) combined with several other severity criteria. We assessed between group differences in all-cause mortality, successful SMR reduction, and symptom relief from baseline to 2-year follow-up. RESULTS: Between March 2011 and March 2018, 138 patients (mean age 75 years) satisfying the inclusion criteria underwent TMVr for treatment of symptomatic SMR. The mean EROA area was 0.35 ± 0.17 mm2 . Ten patients (7%) died within 30 days, 29 (21%) within 12 months, and 41 (30%) within 2 years. After stratification according to the COAPT echocardiographic criteria that were fulfilled in 72% of the studied population, Tier 2 patients (45%), as well as noneligible patients (38%) had a higher mortality rate compared to those in Tier 1 (19%). CONCLUSIONS: SMR patients stratified into tiers according to the COAPT integrative echocardiographic criteria have diverging prognostic and symptomatic benefit after edge-to-edge TMVr.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
20.
Catheter Cardiovasc Interv ; 98(2): E213-E221, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33754441

RESUMEN

OBJECTIVES: We aimed to assess the ischemic and bleeding risks of single antiplatelet therapy (SAPT) with prasugrel compared with standard dual antiplatelet therapy (DAPT) (aspirin plus clopidogrel for 1 year) in patients with chronic coronary syndrome (CCS) treated with new generation drug-eluting stents (DES). BACKGROUND: To date, data on SAPT with potent P2Y12 inhibitors in the absence of aspirin immediately after PCI are limited. METHODS: Between January 2009 and November 2019, all CCS patients undergoing percutaneous coronary intervention (PCI) enrolled to the Bern PCI registry were considered for analysis. We performed propensity score matching in a 1:4 fashion to compare patients who received SAPT with prasugrel versus standard DAPT. The primary ischemic endpoint was a composite of cardiovascular death, myocardial infarction, and stroke and the primary bleeding endpoint was BARC 3 or 5 bleeding, both assessed at 1 year. RESULTS: After propensity score matching, the final study population consisted of 225 patients with SAPT and 889 with DAPT. There was no significant difference in rates of the primary ischemic (5.2% vs. 4.2%, p = .50) or the primary bleeding (1.5% vs. 2.0%, p = .60) endpoints between groups. SAPT was not associated with an increased risk of definite stent thrombosis (0.9% vs. 0.8%, p = .83). CONCLUSIONS: Among selected CCS patients undergoing PCI with DES, SAPT with prasugrel was not associated with an excess of ischemic events compared with standard DAPT. No difference in bleeding was observed either. The results may serve as the basis for larger trials assessing the potential benefits and risks of SAPT.


Asunto(s)
Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Quimioterapia Combinada , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Clorhidrato de Prasugrel/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA