1.
J Vasc Interv Radiol ; 35(7): 1022-1030.e4, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38599280

RESUMEN

PURPOSE: To evaluate the performance of a prototype flexible transbronchial cryoprobe compared with that of percutaneous transthoracic cryoablation and to define cone-beam computed tomography (CT) imaging and pathology cryolesion features in an in vivo swine model. MATERIALS AND METHODS: Transbronchial cryoablation was performed with a prototype flexible cryoprobe (3 central and 3 peripheral lung ablations in 3 swine) and compared with transthoracic cryoablation performed with a commercially available rigid cryoprobe (2 peripheral lung ablations in 1 swine). Procedural time and cryoablation success rates for endobronchial navigation and cryoneedle deployment were measured. Intraoperative cone-beam CT imaging features of cryolesions were characterized and correlated with gross pathology and hematoxylin and eosin-stained sections of the explanted cryolesions. RESULTS: The flexible cryoprobe was successfully navigated and delivered to each target through a steerable guiding sheath (6/6). At 4 minutes after ablation, 5 of 6 transbronchial and 2 of 2 transthoracic cryolesions were visible on cone-beam CT. The volumes on cone-beam CT images were 55.5 cm3 (SE ± 8.0) for central transbronchial ablations (n = 2), 72.5 cm3 (SE ± 8.1) for peripheral transbronchial ablations (n = 3), and 79.5 cm3 (SE ±11.6) for peripheral transthoracic ablations (n = 2). Pneumothorax developed in 1 animal after transbronchial ablation and during ablation in the transthoracic cryoablation. Images of cryoablation zones on cone-beam CT correlated well with the matched gross pathology and histopathology sections of the cryolesions. CONCLUSIONS: Transbronchial cryoablation with a flexible cryoprobe, delivered through a steerable guiding sheath, is feasible. Transbronchial cryoablation zones are imageable with cone-beam CT, with gross pathology and histopathology similar to those of transthoracic cryoablation.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Criocirugía , Diseño de Equipo , Animales , Criocirugía/instrumentación , Tomografía Computarizada de Haz Cónico/instrumentación , Porcinos , Radiografía Intervencional/instrumentación , Pulmón/cirugía , Pulmón/diagnóstico por imagen , Pulmón/patología , Modelos Animales , Broncoscopía/instrumentación , Sus scrofa
2.
J Vasc Interv Radiol ; 33(3): 316-323.e4, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34800622

RESUMEN

PURPOSE: To characterize the hepatic and abdominal angiographic anatomy of woodchucks and vascular changes associated with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty-nine woodchucks (23 with viral-associated HCC, 6 without) underwent multiphasic computed tomography (CT). Fourteen woodchucks (8 with HCC) also underwent diagnostic angiography. Hepatic arterial diameters were measured on the CT scans. Woodchucks were divided into 3 groups: non-tumor-bearing, largest tumor supplied by the right hepatic artery (RHA), and largest tumor supplied by the left hepatic artery (LHA). Statistical analysis with a repeated measures model was performed to determine the effects of tumor location (right, left), vessel measured (RHA, LHA), and interaction between the 2 on vessel diameter. Lobar arteries supplying HCC were compared with those that did not. RESULTS: CT anatomy and normal and variant vascular anatomy were defined. In woodchucks with HCC, LHA and RHA supplying tumors had mean diameters of 2.0 mm ± 0.3 and 1.6 mm ± 0.3 versus 1.5 mm ± 0.3 and 1.1 mm ± 0.2 for non-tumor-supplying arteries (P = .0002 and P < .0001), respectively. Lobar arteries supplying tumors were similarly ectatic. The right lateral lobe artery had the most profound increase in the mean diameter when supplying tumors, measuring 1.7 mm ± 0.1 versus 1.0 mm ± 0.1 in the non-tumor-supplying artery (P < .0001). There were no differences in the diameters of the aorta and celiac, common, and proper hepatic arteries between tumor- and non-tumor-bearing woodchucks. An angiographic atlas of the abdominal vessels was generated. CONCLUSIONS: HCC tumoral vasculature in woodchucks was ectatic compared with normal vasculature. This phenomenon recapitulates human HCC and may facilitate investigation of transcatheter and drug delivery therapies in an HCC animal model.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Abdomen , Angiografía/métodos , Animales , Carcinoma Hepatocelular/patología , Arteria Hepática/patología , Humanos , Neoplasias Hepáticas/patología , Marmota , Pelvis
3.
J Vasc Interv Radiol ; 31(11): 1874-1885, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33129433

RESUMEN

PURPOSE: To assess the feasibility of inducing vascular occlusion by application of radiofrequency (RF) energy via conductive endovascular wires or baskets. MATERIALS AND METHODS: A retrievable nitinol basket and stainless steel guidewire with a platinum tip were evaluated as conductors for endovascular application of RF energy. Tissue-mimicking thermochromic gel phantoms that change color with heating were cast with 2-, 5-, and 7-mm-diameter lumens and filled with 37 oC saline. After ablation, the phantoms were sectioned, and the thermal footprints were evaluated. Six castrated male domestic swine underwent endovascular ablation using the basket in iliac arteries and guidewires in renal arteries. Post-procedural angiography was performed, and postmortem arterial segments were resected for histopathologic analysis. RESULTS: In the phantom, the depth of thermal change in the 5- and 7-mm lumens averaged 6.3 and 6.0 mm along the basket, respectively, and in the 2- and 5-mm lumens, the depth of thermal change averaged 1.9 and 0.5 mm along the wire, respectively. In the swine, RF energy delivery led to angiographic occlusion at 12 of 13 sites. Thermal injury and occlusion were similar at the proximal, middle, and distal basket treatment zone, whereas injury and occlusion decreased from the proximal to the distal end of the 5-cm wire treatment zone. CONCLUSIONS: Endovascular delivery of RF energy via a conductive basket in medium-sized arteries or a guidewire in small arteries led to acute angiographic and histologic occlusion. The potential to induce stasis might be useful in settings where rapid occlusion is desirable.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Ablación por Radiofrecuencia/instrumentación , Arteria Renal/cirugía , Aleaciones , Animales , Conductividad Eléctrica , Diseño de Equipo , Estudios de Factibilidad , Calor , Arteria Ilíaca/patología , Masculino , Ensayo de Materiales , Modelos Animales , Orquiectomía , Platino (Metal) , Arteria Renal/patología , Acero Inoxidable , Sus scrofa
4.
J Vasc Interv Radiol ; 31(5): 812-819.e1, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32107125

RESUMEN

PURPOSE: To assess the feasibility of transarterial chemoembolization with drug-eluting embolic (DEE) microspheres in a woodchuck model of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Nine woodchucks were studied: 4 normal animals and 5 animals infected with woodchuck hepatitis virus in which HCC had developed. Three animals with HCC underwent multidetector CT. A 3-F sheath was introduced into the femoral artery, and the hepatic arteries were selectively catheterized with 2.0-2.4-F microcatheters. Normal animals underwent diagnostic angiography and bland embolization. Animals with HCC underwent DEE transarterial chemoembolization with 70-150-µm radiopaque microspheres loaded with 37.5 mg doxorubicin per milliliter. Cone-beam CT and multidetector CT were performed. Following euthanasia, explanted livers underwent micro-CT, histopathologic examination, and fluorescence imaging of doxorubicin. RESULTS: The tumors were hypervascular and supplied by large-caliber tortuous vessels, with arteriovenous shunts present in 2 animals. There was heterogeneous enhancement on multidetector CT with areas of necrosis. Six tumors were identified. The most common location was the right medial lobe (n = 3). Mean tumor volume was 30.7 cm3 ± 12.3. DEE chemoembolization of tumors was achieved. Excluding the 2 animals with arteriovenous shunts, the mean volume of DEE microspheres injected was 0.49 mL ± 0.17. Fluorescence imaging showed diffusion of doxorubicin from the DEE microspheres into the tumor. CONCLUSIONS: Woodchuck HCC shares imaging appearances and biologic characteristics with human HCC. Selective catheterization and DEE chemoembolization may similarly be performed. Woodchucks may be used to model interventional therapies and possibly characterize radiologic-pathologic correlations.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/terapia , Angiografía de Substracción Digital , Animales , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/virología , Tomografía Computarizada de Haz Cónico , Modelos Animales de Enfermedad , Femenino , Hepatitis B/complicaciones , Hepatitis B/virología , Virus de la Hepatitis B de la Marmota/patogenicidad , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/virología , Masculino , Marmota , Microscopía Fluorescente , Microesferas , Tomografía Computarizada Multidetector , Carga Tumoral
5.
J Vasc Interv Radiol ; 31(12): 2122-2131, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33012647

RESUMEN

PURPOSE: To evaluate the accuracy of cone-beam computed tomography (CT)-based augmented fluoroscopy (AF) image guidance for endobronchial navigation to peripheral lung targets. METHODS: Prototypic endobronchial navigation AF software that superimposed segmented airways, targets, and pathways based on cone-beam CT onto fluoroscopy images was evaluated ex vivo in fixed swine lungs and in vivo in healthy swine (n = 4) without a bronchoscope. Ex vivo and in vivo (n = 3) phase 1 experiments used guide catheters and AF software version 1, whereas in vivo phase 2 (n = 1) experiments also used an endovascular steerable guiding sheath, upgraded AF software version 2, and lung-specific low-radiation-dose protocols. First-pass navigation success was defined as catheter delivery into a targeted airway segment solely using AF, with second-pass success defined as reaching the targeted segment by using updated AF image guidance based on confirmatory cone-beam CT. Secondary outcomes were navigation error, navigation time, radiation exposure, and preliminary safety. RESULTS: First-pass success was 100% (10/10) ex vivo and 19/24 (79%) and 11/15 (73%) for in vivo phases 1 and 2, respectively. Phase 2 second-pass success was 4/4 (100%). Navigation errors were 2.2 ± 1.2 mm ex vivo and 4.9 ± 3.2 mm and 4.0 ± 2.6 mm for in vivo phases 1 and 2, respectively. No major device-related complications were observed in the in vivo experiments. CONCLUSIONS: Endobronchial navigation is feasible and accurate with cone-beam CT-based AF image guidance. AF can guide endobronchial navigation with endovascular catheters and steerable guiding sheaths to peripheral lung targets, potentially overcoming limitations associated with bronchoscopy.


Asunto(s)
Cateterismo/instrumentación , Catéteres , Tomografía Computarizada de Haz Cónico/instrumentación , Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Radiografía Intervencional/instrumentación , Animales , Estudios de Factibilidad , Fluoroscopía/instrumentación , Masculino , Modelos Animales , Interpretación de Imagen Radiográfica Asistida por Computador , Sus scrofa
6.
BMC Vet Res ; 16(1): 451, 2020 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-33228678

RESUMEN

BACKGROUND: Teratomas are germ cell neoplasms composed of a wide variety of tissues. In the woodchuck, only one testicular teratoma has been described in the literature. The objective of this report was to describe the radiologic and pathologic findings in a female woodchuck (Marmota monax) with an ovarian teratoma consisting of mature tissues originating from all three germ layers. CASE PRESENTATION: A 2-year-old female woodchuck that had been infected at birth with woodchuck hepatitis virus and subsequently developed hepatocellular carcinoma was incidentally discovered to have a mobile 6.6 × 4.8 × 4.7 cm abdominal mass on computed tomography (CT) imaging. The tumor was predominantly solid and heterogenous on CT with soft tissue, fat, and areas of dense calcification. The teratoma did not enhance with intravenous contrast administration. On ultrasound, the tumor was solid with heterogeneous echogenicity, reflecting the fat content and areas of calcification. Sonolucent areas were present that may have represented cysts. There was heterogeneously increased signal on T1-weighted magnetic resonance imaging (MRI) and heterogeneous hyperintensity in T2-weighted imaging. Fat was evident within the tumor. At necropsy, the tumor was attached to the distal end of the right uterine horn. Histopathology showed mature tissue types representing all three germ layers. CONCLUSIONS: Ovarian teratoma should be considered in the differential diagnosis of ovarian or abdominal masses in woodchucks. The tumor displayed mature tissue derived from all three germ layers. CT, ultrasound, and MRI findings were presented in detail and matched the typical imaging appearance of teratomas.


Asunto(s)
Carcinoma Hepatocelular/veterinaria , Marmota , Neoplasias Ováricas/veterinaria , Teratoma/veterinaria , Animales , Femenino , Hepatitis B/veterinaria , Virus de la Hepatitis B de la Marmota , Neoplasias Hepáticas/veterinaria , Imagen por Resonancia Magnética/veterinaria , Neoplasias Ováricas/diagnóstico por imagen , Neoplasias Ováricas/patología , Teratoma/diagnóstico por imagen , Teratoma/patología , Tomografía Computarizada por Rayos X/veterinaria , Ultrasonografía/veterinaria
7.
J Biomech Eng ; 142(12)2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34043756

RESUMEN

Swine are a commonly used model in translational pulmonary research. However, in vivo airway morphometry during respiration has not been studied in extensive detail using modern imaging tools. Chest computed tomographic was performed in swine (n = 3) at multiple stages of respiration. Morphometric parameters of each airway segment at end-expiration and end-inspiration were compared as well as among matched anatomical regions (proximal and distal; ventral, lateral, and dorsal). Analysis included segment diameter, length, ellipticity, and the bifurcation angle between daughter branches. Deformation of the airway during respiration was qualitatively visualized using a point-to-point deformation map. Comparison of airway generation showed airway diameter and length were larger at end-inspiration in the fourth and seventh generations compared to end-expiration. Bifurcation angle was larger at end-inspiration compared to end-expiration. Analysis by anatomical region showed that length and bifurcation angle were larger at inspiration in the distal airway regions only. Regardless of respiratory phase, the lateral regions had larger diameters and lengths compared to the ventral and dorsal regions at similar generations and proximal regions had larger bifurcation angles. The findings that morphological changes were more prevalent in distal airways during respiration was confirmed by analysis of a deformation map. Compared to human airway models, the relative diameter may be smaller and length may be greater in swine in similar airway generations. This morphometric description of the swine airways during respiration may guide conduct of preclinical translational studies, revealing advantages and limitations of swine models for specific evaluations. Such morphometric parameters may directly determine the suitability of the swine model for the study of lung interventions, in terms of recapitulation of human morphometry dynamics.


Asunto(s)
Respiración , Animales , Espiración , Pulmón , Porcinos , Tomografía Computarizada por Rayos X
8.
J Vasc Interv Radiol ; 30(12): 1908-1914, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31409568

RESUMEN

PURPOSE: To determine whether burn time per tumor volume (BPV) (min/mL), where burn time is the total time during which radiofrequency (RF) energy is being applied, is correlated with hepatocellular carcinoma (HCC) treatment outcomes using RF ablation and lyso-thermosensitive liposomal doxorubicin (LTLD). MATERIALS AND METHODS: The HEAT study was a double-blind, randomized controlled phase III trial of RF ablation only versus RF ablation + LTLD in patients with HCCs 3-7 cm in diameter. Effect of BPV on progression-free survival and overall survival (OS) was analyzed. RESULTS: BPV demonstrated statistically significant differences between study groups for OS (P = .038, hazard ratio [HR] = 0.85), but not for progression-free survival (P = .389, HR = 1.059). In a separate analysis, treatment groups were independently analyzed to determine the effect of BPV within each individual group. OS improved as BPV increased for patients receiving RF ablation + LTLD (P = .017, HR = 0.836, confidence interval [0.722, 0.968]). This same association was not observed in patients receiving RF ablation only (P = .57, HR = 0.99). CONCLUSIONS: BPV may be a useful metric for RF ablation + LTLD combination therapy for solitary HCC. The analysis suggested that the burn time for the tumor needs to be adjusted depending on the tumor volume. Because this is a post hoc study, the results are only suggestive and need to be confirmed with prospective studies.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Carcinoma Hepatocelular/terapia , Doxorrubicina/análogos & derivados , Neoplasias Hepáticas/terapia , Tempo Operativo , Ablación por Radiofrecuencia , Carga Tumoral , Antibióticos Antineoplásicos/efectos adversos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Quimioterapia Adyuvante , Ensayos Clínicos Fase III como Asunto , Progresión de la Enfermedad , Doxorrubicina/administración & dosificación , Doxorrubicina/efectos adversos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Polietilenglicoles/administración & dosificación , Polietilenglicoles/efectos adversos , Supervivencia sin Progresión , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/mortalidad , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Factores de Tiempo
9.
Int J Mol Sci ; 20(16)2019 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-31405104

RESUMEN

We studied the effect of radiation from computed tomography (CT) scans on differentiation of human embryonic stem cells (hESCs) into neuronal lineage. hESCs were divided into three radiation exposure groups: 0-dose, low-dose, or high-dose exposure. Low dose was accomplished with a single 15 mGy CT dose index (CTDI) CT scan that approximated the dose for abdominal/pelvic CT examinations in adults while the high dose was achieved with several consecutive CT scans yielding a cumulative dose of 500 mGy CTDI. The neural induction was characterized by immunocytochemistry. Quantitative polymerase chain reaction (qPCR) and Western blots were used to measure expression of the neuronal markers PAX6 and NES and pluripotency marker OCT4. We did not find any visible morphological differences between neural precursors from irradiated and non-irradiated cells. However, quantitative analyses of neuronal markers showed that PAX6 expression was reduced following exposure to the high dose compared to 0-dose controls, while no such decrease in PAX6 expression was observed following exposure to the low dose. Similarly, a statistically significant reduction in expression of NES was observed following high-dose exposure, while after low-dose exposure, a modest but statistically significant reduction in NES expression was only observed on Day 8 of differentiation. Further studies are warranted to elucidate how lower or delayed expression of PAX6 and NES can impact human fetal brain development.


Asunto(s)
Células Madre Embrionarias Humanas/efectos de la radiación , Células-Madre Neurales/efectos de la radiación , Neurogénesis/efectos de la radiación , Tomografía Computarizada por Rayos X/efectos adversos , Línea Celular , Regulación hacia Abajo/efectos de la radiación , Células Madre Embrionarias Humanas/citología , Células Madre Embrionarias Humanas/metabolismo , Humanos , Células-Madre Neurales/citología , Células-Madre Neurales/metabolismo , Factor de Transcripción PAX6/genética , Dosis de Radiación , Radiación Ionizante
10.
Radiology ; 289(2): 396-404, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30106347

RESUMEN

Purpose To correlate bead location and attenuation on CT images with the quantity and distribution of drug delivered to the liver following transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEB) in a rabbit tumor model. Materials and Methods All procedures were performed with a protocol approved by the Institutional Animal Care and Use Committee. TACE was performed in rabbits (n = 4) bearing VX2 liver tumors by using radiopaque DEB (70-150 µm) loaded with doxorubicin (DOX). Livers were resected 1 hour after embolization, immediately frozen, and cut by using liver-specific three-dimensional-printed molds for colocalization of liver specimens and CT imaging. DOX penetration into tissue surrounding beads was evaluated with fluorescence microscopy. DOX levels in liver specimens were predicted by using statistical models correlating DOX content measured in tissue with bead volume and attenuation measured on CT images. Model predictions were then compared with actual measured DOX concentrations to assess the models' predictive power. Results Eluted DOX remained in close proximity (<600 µm) to beads in the liver 1 hour after TACE. Bead volume and attenuation measured on CT images demonstrated positive linear correlations (0.950 and 0.965, respectively) with DOX content in liver specimens. DOX content model predictions based on CT images were accurate compared with actual liver DOX levels at 1 hour. Conclusion CT may be used to estimate drug dose delivery and distribution in the liver following transarterial chemoembolization (TACE) with doxorubicin-loaded radiopaque drug-eluting beads (DEB). Although speculative, this informational map might be helpful in planning and understanding the spatial effects of TACE with DEB. © RSNA, 2018.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Doxorrubicina/administración & dosificación , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Tomografía Computarizada por Rayos X/métodos , Animales , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos , Hígado/diagnóstico por imagen , Microesferas , Conejos
11.
J Vasc Interv Radiol ; 29(4): 568-574, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29500000

RESUMEN

PURPOSE: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings. MATERIALS AND METHODS: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-µm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp. The animal was euthanized, the liver resected, and microCT with 17 µm resolution performed on embolized tissue samples. The resulting cone-beam CT and microCT data were segmented and registered. Total vessel length, minimum volume-enclosing ellipsoid (MVEE), and number of independent volumes were measured. Maximum-intensity projections (MIPs) were generated for each cone-beam CT. RESULTS: Metrics for all cone-beam CT segmentations differed significantly from microCT segmentations. Segmentations at 80 kVp presented significantly greater vessel length, MVEE, and number of independent volumes compared with 100 kVp and 120 kVp. In addition, 100 kVp segmentations presented significantly greater vessel length than 120 kVp. MIPs presented greater visualization than cone-beam CT segmentations and improved as kVp decreased. CONCLUSIONS: The full ROB distribution was more extensive than was apparent on cone-beam CT. Quantitative measures of embolic distribution demonstrated significantly better correlation with microCT with decreasing kVp. Similarly, qualitative analysis of MIPs showed improved visualization of beads with decreasing kVp. These findings demonstrate the clinical value of 80 kVp and 100 kVp protocols in the imaging of radiopaque embolizations compared with 120 kVp. However, considerations on X-ray penetration and dose may favor use of 100 kVp imaging over 80 kVp.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Embolización Terapéutica/instrumentación , Hígado/irrigación sanguínea , Microtomografía por Rayos X/métodos , Animales , Fluoroscopía , Microesferas , Modelos Animales , Porcinos
12.
Int J Hyperthermia ; 33(7): 733-740, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28540814

RESUMEN

PURPOSE: To evaluate lyso-thermosensitive liposomal doxorubicin (LTLD, ThermoDox®) in combination with loco-regional mild hyperthermia (HT) for targeted drug delivery to the bladder wall and potential treatment of bladder cancer. MATERIAL AND METHODS: Porcine in vivo studies were performed with the following groups: (i) intravenous (IV) LTLD with hyperthermia (LTLD + HT); (ii) IV doxorubicin (DOX) with hyperthermia (IV DOX + HT) and (iii) IV LTLD without hyperthermia (LTLD - HT). Drug formulations were delivered via 30 min IV infusion coinciding with 1-h bladder irrigation (45 °C water for HT groups, 37 °C for non-HT group), followed by immediate bladder resection. DOX concentrations were measured in consecutive sections parallel to the bladder lumen by liquid chromatography following drug extraction. Computer models were developed to simulate tissue heating and drug release from LTLD. RESULTS: Comparing mean DOX concentrations at increasing depths from the lumen to outer surface of the bladder wall, the ranges for LTLD + HT, IV DOX + HT and LTLD - HT, respectively, were 20.32-3.52 µg/g, 2.34-0.61 µg/g and 2.18-0.51 µg/g. The average DOX concentrations in the urothelium/lamina and muscularis, respectively, were 9.7 ± 0.67 and 4.09 ± 0.81 µg/g for IV LTLD + HT, 1.2 ± 0.39 and 0.86 ± 0.24 µg/g for IV DOX + HT, and 1.15 ± 0.38 and 0.62 ± 0.15 µg/g for LTLD - HT. Computational model results were similar to measured DOX levels and suggest adequate temperatures were reached within the bladder wall for drug release from LTLD. CONCLUSIONS: Doxorubicin accumulation and distribution within the bladder wall was achieved at concentrations higher than with free IV doxorubicin by mild bladder hyperthermia combined with systemic delivery of LTLD.


Asunto(s)
Antibióticos Antineoplásicos/administración & dosificación , Doxorrubicina/análogos & derivados , Sistemas de Liberación de Medicamentos , Hipertermia Inducida , Animales , Antibióticos Antineoplásicos/farmacocinética , Terapia Combinada , Doxorrubicina/administración & dosificación , Doxorrubicina/farmacocinética , Femenino , Polietilenglicoles/administración & dosificación , Polietilenglicoles/farmacocinética , Porcinos , Vejiga Urinaria/metabolismo , Neoplasias de la Vejiga Urinaria/terapia
13.
Phys Med Biol ; 69(14)2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38942009

RESUMEN

Objective.With the introduction of spectral CT techniques into the clinic, the imaging capacities of CT were expanded to multiple energy levels. Due to a variety of factors, the acquired signal in spectral CT datasets is shared between these images. Conventional image quality metrics assume independence between images which is not preserved within spectral CT datasets, limiting their utility for characterizing energy selective images. The purpose of this work was to develop a metrology to characterize energy selective images by incorporating the shared information between images within a spectral CT dataset.Approach.The signal-to-noise ratio (SNR) was extended into a multivariate space where each image within a spectral CT dataset was treated as a separate information channel. The general definition was applied to the specific case of contrast to define a multivariate contrast-to-noise ratio (CNR). The matrix contained two types of terms: a conventional CNR term which characterized image quality within each image in the spectral CT dataset and covariance weighted CNR (Covar-CNR) which characterized the contrast in each image relative to the covariance between images. Experimental data from an investigational photon-counting CT scanner was used to demonstrate the insight of this metrology. A cylindrical water phantom containing vials of iodine and gadolinium (2, 4, and 8 mg ml-1) was imaged under conditions of variable tube current, tube voltage, and energy threshold. Two image series (threshold and bin images) containing two images each were defined based upon the contribution of photons to reconstructed images. Analysis of variance (ANOVA) was calculated between CNR terms and image acquisition variables. A multivariate regression was then fitted to experimental data.Main Results.Image type had a major difference on how Covar-CNR values were distributed. Bin images had a slightly higher mean and wider standard deviation (Covar-CNRlo: 3.38 ±17.25, Covar-CNRhi: 5.77 ± 30.64) compared to threshold images (Covar-CNRlo: 2.08 ±1.89, Covar-CNRhi: 3.45 ± 2.49) across all conditions. ANOVA found that each acquisition variable had a significant relationship with both Covar-CNR terms. The multivariate regression model suggested that material concentration had the largest impact on all CNR terms.Signficance.In this work, we described a theoretical framework to extend the SNR to a multivariate form that is able to characterize images independently and also provide insight regarding the relationship between images. Experimental data was used to demonstrate the insight that this metrology provides about image formation factors in spectral CT.


Asunto(s)
Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Análisis Multivariante , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos
14.
Phys Med ; 122: 103382, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38820805

RESUMEN

PURPOSE: In this work, we define a signal detection based metrology to characterize the separability of two different multi-dimensional signals in spectral CT acquisitions. METHOD: Signal response was modelled as a random process with a deterministic signal and stochastic noise component. A linear Hotelling observer was used to estimate a scalar test statistic distribution that predicts the likelihood of an intensity value belonging to a signal. Two distributions were estimated for two materials of interest and used to derive two metrics separability: a separability index (s') and the area under the curve of the test statistic distributions. Experimental and simulated data of photon-counting CT scanners were used to evaluate each metric. Experimentally, vials of iodine and gadolinium (2, 4, 8 mg/mL) were scanned at multiple tube voltages, tube currents and energy thresholds. Additionally, a simulated dataset with low tube current (10-150 mAs) and material concentrations (0.25-4 mg/mL) was generated. RESULTS: Experimental data showed that conditions favorable for low noise and expression of k-edge signal produced the highest separability. Material concentration had the greatest impact on separability. The simulated data showed that under more difficult separation conditions, difference in material concentration still had the greatest impact on separability. CONCLUSION: The results demonstrate the utility of a task specific metrology to measure the overlap in signal between different materials in spectral CT. Using experimental and simulated data, the separability index was shown to describe the relationship between image formation factors and the signal responses of material.


Asunto(s)
Tomografía Computarizada por Rayos X , Yodo , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos , Gadolinio/química , Fantasmas de Imagen
15.
Invest Radiol ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38767436

RESUMEN

OBJECTIVES: The aim of this study was to assess the interreader reliability and per-RCC sensitivity of high-resolution photon-counting computed tomography (PCCT) in the detection and characterization of renal masses in comparison to MRI. MATERIALS AND METHODS: This prospective study included 24 adult patients (mean age, 52 ± 14 years; 14 females) who underwent PCCT (using an investigational whole-body CT scanner) and abdominal MRI within a 3-month time interval and underwent surgical resection (partial or radical nephrectomy) with histopathology (n = 70 lesions). Of the 24 patients, 17 had a germline mutation and the remainder were sporadic cases. Two radiologists (R1 and R2) assessed the PCCT and corresponding MRI studies with a 3-week washout period between reviews. Readers recorded the number of lesions in each patient and graded each targeted lesion's characteristic features, dimensions, and location. Data were analyzed using a 2-sample t test, Fisher exact test, and weighted kappa. RESULTS: In patients with von Hippel-Lindau mutation, R1 identified a similar number of lesions suspicious for neoplasm on both modalities (51 vs 50, P = 0.94), whereas R2 identified more suspicious lesions on PCCT scans as compared with MRI studies (80 vs 56, P = 0.12). R1 and R2 characterized more lesions as predominantly solid in MRIs (R1: 58/70 in MRI vs 52/70 in PCCT, P < 0.001; R2: 60/70 in MRI vs 55/70 in PCCT, P < 0.001). R1 and R2 performed similarly in detecting neoplastic lesions on PCCT and MRI studies (R1: 94% vs 90%, P = 0.5; R2: 73% vs 79%, P = 0.13). CONCLUSIONS: The interreader reliability and per-RCC sensitivity of PCCT scans acquired on an investigational whole-body PCCT were comparable to MRI scans in detecting and characterizing renal masses. CLINICAL RELEVANCE STATEMENT: PCCT scans have comparable performance to MRI studies while allowing for improved characterization of the internal composition of lesions due to material decomposition analysis. Future generations of this imaging modality may reveal additional advantages of PCCT over MRI.

16.
Artículo en Inglés | MEDLINE | ID: mdl-38814530

RESUMEN

PURPOSE: Targeting accuracy determines outcomes for percutaneous needle interventions. Augmented reality (AR) in IR may improve procedural guidance and facilitate access to complex locations. This study aimed to evaluate percutaneous needle placement accuracy using a goggle-based AR system compared to an ultrasound (US)-based fusion navigation system. METHODS: Six interventional radiologists performed 24 independent needle placements in an anthropomorphic phantom (CIRS 057A) in four needle guidance cohorts (n = 6 each): (1) US-based fusion, (2) goggle-based AR with stereoscopically projected anatomy (AR-overlay), (3) goggle AR without the projection (AR-plain), and (4) CT-guided freehand. US-based fusion included US/CT registration with electromagnetic (EM) needle, transducer, and patient tracking. For AR-overlay, US, EM-tracked needle, stereoscopic anatomical structures and targets were superimposed over the phantom. Needle placement accuracy (distance from needle tip to target center), placement time (from skin puncture to final position), and procedure time (time to completion) were measured. RESULTS: Mean needle placement accuracy using US-based fusion, AR-overlay, AR-plain, and freehand was 4.5 ± 1.7 mm, 7.0 ± 4.7 mm, 4.7 ± 1.7 mm, and 9.2 ± 5.8 mm, respectively. AR-plain demonstrated comparable accuracy to US-based fusion (p = 0.7) and AR-overlay (p = 0.06). Excluding two outliers, AR-overlay accuracy became 5.9 ± 2.6 mm. US-based fusion had the highest mean placement time (44.3 ± 27.7 s) compared to all navigation cohorts (p < 0.001). Longest procedure times were recorded with AR-overlay (34 ± 10.2 min) compared to AR-plain (22.7 ± 8.6 min, p = 0.09), US-based fusion (19.5 ± 5.6 min, p = 0.02), and freehand (14.8 ± 1.6 min, p = 0.002). CONCLUSION: Goggle-based AR showed no difference in needle placement accuracy compared to the commercially available US-based fusion navigation platform. Differences in accuracy and procedure times were apparent with different display modes (with/without stereoscopic projections). The AR-based projection of the US and needle trajectory over the body may be a helpful tool to enhance visuospatial orientation. Thus, this study refines the potential role of AR for needle placements, which may serve as a catalyst for informed implementation of AR techniques in IR.

17.
bioRxiv ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39282453

RESUMEN

Intratumoral injections often lack visibility, leading to unpredictable outcomes such as incomplete tumor coverage, off-target drug delivery and systemic toxicities. This study investigated an ultrasound (US) and x-ray imageable thermosensitive hydrogel based on poloxamer 407 (POL) percutaneously delivered in a healthy swine model. The primary objective was to assess the 2D and 3D distribution of the hydrogel within tissue across three different needle devices and injection sites: liver, kidney, and intercostal muscle region. Secondly, pharmacokinetics of POL loaded with doxorubicin (POLDOX) were evaluated and compared to free doxorubicin injection (DOXSoln) with a Single End Hole Needle. Utilizing 2D and 3D morphometrics from US and x-ray imaging techniques such as Computed Tomography (CT) and Cone Beam CT (CBCT), we monitored the localization and leakage of POLDOX over time. Relative iodine concentrations measured with CBCT following incorporation of an iodinated contrast agent in POL indicated potential drug diffusion and advection transport. Furthermore, US imaging revealed temporal changes, suggesting variations in acoustic intensity, heterogeneity, and echotextures. Notably, 3D reconstruction of the distribution of POL and POLDOX from 2D ultrasound frames was achieved and morphometric data obtained. Pharmacokinetic analysis revealed lower systemic exposure of the drug in various organs with POLDOX formulation compared to DOXSoln formulation. This was demonstrated by a lower area under the curve (852.1 ± 409.1 ng/mL·h vs 2283.4 ± 377.2 ng/mL·h) in the plasma profile, suggesting a potential reduction in systemic toxicity. Overall, the use of POL formulation offers a promising strategy for precise and localized drug delivery, that may minimize adverse effects. Dual modality POL imaging enabled analysis of patterns of gel distribution and morphology, alongside of pharmacokinetics of local delivery. Incorporating hydrogels into drug delivery systems holds significant promise for improving the predictability of the delivered drug and enhancing spatial conformability. These advancements can potentially enhance the safety and precision of anticancer therapy.

18.
Sci Rep ; 14(1): 20929, 2024 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-39251665

RESUMEN

Transarterial chemoembolization (TACE) is an image-guided minimally invasive treatment for liver cancer which involves delivery of chemotherapy and embolic material into tumor-supplying arteries to block blood flow to a liver tumor and to deliver chemotherapy directly to the tumor. However, the released drug diffuses only less than a millimeter away from the beads. To enhance the efficacy of TACE, the development of microbubbles electrostatically bound to the surface of drug-eluting beads loaded with different amounts of doxorubicin (0-37.5 mg of Dox/mL of beads) is reported. Up to 400 microbubbles were bound to Dox-loaded beads (70-150 microns). This facilitated ultrasound imaging of the beads and increased the release rate of Dox upon exposure to high intensity focused ultrasound (HIFU). Furthermore, ultrasound exposure (1 MPa peak negative pressure) increased the distance at which Dox could be detected from beads embedded in a tissue-mimicking phantom, compared with a no ultrasound control.


Asunto(s)
Quimioembolización Terapéutica , Doxorrubicina , Sistemas de Liberación de Medicamentos , Microburbujas , Ultrasonografía , Doxorrubicina/administración & dosificación , Doxorrubicina/química , Sistemas de Liberación de Medicamentos/métodos , Quimioembolización Terapéutica/métodos , Ultrasonografía/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/terapia , Fantasmas de Imagen , Antibióticos Antineoplásicos/administración & dosificación , Antibióticos Antineoplásicos/química , Microesferas
19.
Res Sq ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38978563

RESUMEN

Intratumoral injections have the potential for enhanced cancer treatment efficacy while reducing costs and systemic exposure. However, intratumoral drug injections can result in substantial off-target leakage and are invisible under standard imaging modalities like ultrasound (US) and x-ray. A thermosensitive poloxamer-based gel for drug delivery was developed that is visible using x-ray imaging (computed tomography (CT), cone beam CT, fluoroscopy), as well as using US by means of integrating perfluorobutane-filled microbubbles (MBs). MBs content was optimized using tissue mimicking phantoms and ex vivo bovine livers. Gel formulations less than 1% MBs provided gel depositions that were clearly identifiable on US and distinguishable from tissue background and with minimal acoustic artifacts. The cross-sectional areas of gel depositions obtained with US and CT imaging were similar in studies using ex vivo bovine liver and postmortem in situ swine liver. The gel formulation enhanced multimodal image-guided navigation, enabling fusion of ultrasound and x-ray/CT imaging, which may enhance targeting, definition of spatial delivery, and overlap of tumor and gel. Although speculative, such a paradigm for intratumoral drug delivery might streamline clinical workflows, reduce radiation exposure by reliance on US, and boost the precision and accuracy of drug delivery targeting during procedures. Imageable gels may also provide enhanced temporal and spatial control of intratumoral conformal drug delivery.

20.
Sci Rep ; 14(1): 20455, 2024 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227382

RESUMEN

Intratumoral injections have the potential for enhanced cancer treatment efficacy while reducing costs and systemic exposure. However, intratumoral drug injections can result in substantial off-target leakage and are invisible under standard imaging modalities like ultrasound (US) and x-ray. A thermosensitive poloxamer-based gel for drug delivery was developed that is visible using x-ray imaging (computed tomography (CT), cone beam CT, fluoroscopy), as well as using US by means of integrating perfluorobutane-filled microbubbles (MBs). MBs content was optimized using tissue mimicking phantoms and ex vivo bovine livers. Gel formulations less than 1% MBs provided gel depositions that were clearly identifiable on US and distinguishable from tissue background and with minimal acoustic artifacts. The cross-sectional areas of gel depositions obtained with US and CT imaging were similar in studies using ex vivo bovine liver and postmortem in situ swine liver. The gel formulation enhanced multimodal image-guided navigation, enabling fusion of ultrasound and x-ray/CT imaging, which may enhance targeting, definition of spatial delivery, and overlap of tumor and gel. Although speculative, such a paradigm for intratumoral drug delivery might streamline clinical workflows, reduce radiation exposure by reliance on US, and boost the precision and accuracy of drug delivery targeting during procedures. Imageable gels may also provide enhanced temporal and spatial control of intratumoral conformal drug delivery.


Asunto(s)
Sistemas de Liberación de Medicamentos , Hidrogeles , Hígado , Poloxámero , Ultrasonografía , Poloxámero/química , Animales , Hidrogeles/química , Hígado/diagnóstico por imagen , Hígado/metabolismo , Bovinos , Ultrasonografía/métodos , Sistemas de Liberación de Medicamentos/métodos , Microburbujas , Porcinos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada de Haz Cónico/métodos