RESUMEN
Instantaneous heart rate (IHR) has been investigated for sleep applications, such as sleep apnea detection and sleep staging. To ensure the comfort of the patient during sleep, it is desirable for IHR to be measured in a contact-free fashion. In this work, we use speckle vibrometry (SV) to perform on-skin and on-textile IHR monitoring in a sleep setting. Minute motions on the laser-illuminated surface can be captured by a defocused camera, enabling the detection of cardiac motions even on textiles. We investigate supine, lateral, and prone sleeping positions. Based on Bland-Altman analysis between SV cardiac measurements and electrocardiogram (ECG), with respect to each position, we achieve the best limits of agreement with ECG values of [-8.65, 7.79] bpm, [-9.79, 9.25] bpm, and [-10.81, 10.23] bpm, respectively. The results indicate the potential of using speckle vibrometry as a contact-free monitoring method for instantaneous heart rate in a setting where the participant is allowed to rest in a spontaneous position while covered by textile layers.
Asunto(s)
Electrocardiografía , Determinación de la Frecuencia Cardíaca , Humanos , Monitoreo Fisiológico , Frecuencia Cardíaca/fisiología , Electrocardiografía/métodos , Sueño/fisiologíaRESUMEN
This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.
Asunto(s)
Electrocardiografía , Fotopletismografía , Frecuencia Cardíaca/fisiología , Monitoreo FisiológicoRESUMEN
Monitoring of heart rate in patients in the general ward is necessary to assess the clinical situation of the patient. Currently, this is done via spot-checks on pulse rate manually or on heart rate using Electrocardiogram (ECG) by nurses. More frequent measurements would allow early detection of adverse cardiac events. In this work, we investigate a contactless measurement setup combined with a signal processing pipeline, which is based on speckle vibrometry (SV), to perform contactless heart rate monitoring of human subjects in a supine position, mimicking a resting scenario in the general ward. Our results demonstrate the feasibility of extracting heart rate with SV through varying textile thicknesses (i.e., 8 mm, 32 mm and 64 mm), with an error smaller than 3 beats per minute on average compared to the ground-truth heart rate derived from ECG.