Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 31(9): 6708-6716, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33758955

RESUMEN

OBJECTIVES: To compare the impact of laxative enema preparation versus air/gas suction through a small catheter on image quality of prostate DWI. METHODS: In this single-center study, 200 consecutive patients (100 in each arm) with either enema or catheter preparation were retrospectively included. Two blinded readers independently assessed aspects of image quality on 5-point Likert scales. Scores were compared between groups and the influence of confounding factors evaluated using multivariable logistic regression. Prostate diameters were compared on DWI and T2-weighted imaging using intraclass correlation coefficients. RESULTS: Image quality was significantly higher in the enema group regarding the severity of susceptibility-related artifacts (reader 1: 0.34 ± 0.77 vs. 1.73 ± 1.34, reader 2: 0.38 ± 0.86 vs. 1.76 ± 1.39), the differentiability of the anatomy (reader 1: 3.36 ± 1.05 vs. 2.08 ± 1.31, reader 2: 3.37 ± 1.05 vs. 2.09 ± 1.35), and the overall image quality (reader 1: 3.66 ± 0.77 vs. 2.26 ± 1.33, Reader 2: 3.59 ± 0.87 vs. 2.23 ± 1.38) with almost perfect inter-observer agreement (κ = 0.92-0.95). In the enema group, rectal distention was significantly lower and strongly correlated with the severity of artifacts (reader 1: ρ = 0.79, reader 2: ρ = 0.73). Furthermore, there were significantly fewer substantial image distortions, with odds ratios of 0.051 and 0.084 for the two readers which coincided with a higher agreement of the prostate diameters in the phase-encoding direction (0.96 vs. 0.89). CONCLUSIONS: Enema preparation is superior to catheter preparation and yields substantial improvements in image quality. KEY POINTS: • Enema preparation is superior to decompression of the rectum using air/gas suction through a small catheter. • Enema preparation markedly improves the image quality of prostate DWI regarding the severity of susceptibility-related artifacts, the differentiability of the anatomy, and the overall image quality and considerably reduces substantial artifacts that may impair a reliable diagnosis.


Asunto(s)
Próstata , Neoplasias de la Próstata , Catéteres , Imagen de Difusión por Resonancia Magnética , Enema , Humanos , Masculino , Próstata/diagnóstico por imagen , Estudios Retrospectivos
2.
Eur Radiol ; 31(11): 8725-8732, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33909134

RESUMEN

OBJECTIVES: We investigate in what percentage of cases and to what extent radiological reports change when radiologists directly communicate with patients after imaging examinations. METHODS: One hundred twenty-two consecutive outpatients undergoing MRI examinations at a single center were prospectively included. Radiological reports of the patients were drafted by two radiologists in consensus using only the clinical information that was made available by the referring physicians. Thereafter, one radiologist talked directly with the patient and recorded the duration of the conversation. Afterwards, the additional information from the patient was used to reevaluate the imaging studies in consensus. The radiologists determined whether the radiological report changed based on additional information and, if yes, to what extent. The degree of change was graded on a 4-point Likert scale (1, non-relevant findings, to 4, highly relevant findings). RESULTS: Following direct communication (duration 170.9 ± 53.9 s), the radiological reports of 52 patients (42.6%) were changed. Of the 52 patients, the degree of change was classified as grade 1 for 8 patients (15.4 %), grade 2 for 27 patients (51.9%), grade 3 for 13 patients (25%), and grade 4 for 4 patients (7.7%). The reasons leading to changes were missing clinical information in 50 cases (96.2%) and the lack of additional external imaging in 2 cases (3.8%). CONCLUSIONS: Radiologists should be aware that a lack of accurate information from the clinician can lead to incorrect radiological reports or diagnosis. Radiologists should communicate directly with patients, especially when the provided information is unclear, as it may significantly alter the radiological report. KEY POINTS: • Direct communication between radiologists and patients for an average of 170's resulted in a change in the radiological reports of 52 patients (42.6%). • Of the 42.6% of cases where the reports were changed, the alterations were highly relevant (grades 3 and 4) in 32.7%, indicating major changes with significant impact towards patient management.


Asunto(s)
Radiólogos , Radiología , Comunicación , Humanos , Imagen por Resonancia Magnética , Radiografía
3.
Eur Radiol ; 29(11): 5813-5822, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31020338

RESUMEN

PURPOSE: To identify independent confounding variables of gadoxetate-enhanced hepatobiliary-phase liver MRI using multiple regression analysis. MATERIALS AND METHODS: The institutional review board generally approved retrospective analyses and all patients provided written informed consent. One hundred ten patients who underwent a standardized 3.0-T gadoxetate-enhanced liver MRI between November 2008 and June 2013 were retrospectively reviewed. The gadoxetate liver enhancement normalized to enhancement in the erector spinae muscle (relative signal enhancement, SE) was related to biochemical laboratory parameters and descriptive patient characteristics (patient age, body mass index) using non-parametric univariate correlation analysis followed by a multiple linear regression model. RESULTS: Using univariate statistics, relative SE was inversely correlated with patient age, ALP, AST, total bilirubin, gamma-glutamyltransferase, INR, model of end-stage liver disease score, and proportionally with albumin and hemoglobin (all p < 0.01). In a multiple regression analysis, total bilirubin (p = 0.001), serum albumin (p = 0.016), and patient age (p = 0.018) were independently correlated with relative liver SE (n = 110). CONCLUSION: A multiple regression analysis showed that high total bilirubin, low serum albumin, or advanced age was associated with low hepatobiliary-phase gadoxetate parenchymal liver enhancement. In these patients, the lower contrast-to-noise ratio might impair diagnostic evaluation of non-enhancing liver lesions (e.g., HCC, liver metastasis). KEY POINTS: • A multiple regression analysis identified independent confounding variables of hepatobiliary-phase gadoxetate liver enhancement. • High bilirubin, low albumin, or advanced age was associated with low enhancement. • Diagnostic evaluation might be hampered in these patients.


Asunto(s)
Bilirrubina/metabolismo , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Albúmina Sérica/metabolismo , Adulto , Anciano , Biomarcadores de Tumor/metabolismo , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , gamma-Glutamiltransferasa/metabolismo
4.
Eur Radiol ; 29(2): 527-534, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30062526

RESUMEN

OBJECTIVES: To determine whether it would be hygienic to evaluate dogs and humans in the same MRI scanner. METHODS: We compared the bacterial load in colony-forming units (CFU) of human-pathogenic microorganisms in specimens taken from 18 men and 30 dogs. In addition, we compared the extent of bacterial contamination of an MRI scanner shared by dogs and humans with two other MRI scanners used exclusively by humans. RESULTS: Our study shows a significantly higher bacterial load in specimens taken from men's beards compared with dogs' fur (p = 0.036). All of the men (18/18) showed high microbial counts, whereas only 23/30 dogs had high microbial counts and 7 dogs moderate microbial counts. Furthermore, human-pathogenic microorganisms were more frequently found in human beards (7/18) than in dog fur (4/30), although this difference did not reach statistical significance (p = 0.074). More microbes were found in human oral cavities than in dog oral cavities (p < 0.001). After MRI of dogs, routine scanner disinfection was undertaken and the CFU found in specimens isolated from the MRI scanning table and receiver coils showed significantly lower bacteria count compared with "human" MRI scanners (p < 0.05). CONCLUSION: Our study shows that bearded men harbour significantly higher burden of microbes and more human-pathogenic strains than dogs. As the MRI scanner used for both dogs and humans was routinely cleaned after animal scanning, there was substantially lower bacterial load compared with scanners used exclusively for humans. KEY POINTS: • Bearded men harbour significantly more microbes than dogs. • Dogs are no risk to humans if they use the same MRI. • Deficits in hospital hygiene are a relevant risk for patients.


Asunto(s)
Perros/microbiología , Cabello/microbiología , Higiene , Imagen por Resonancia Magnética/instrumentación , Pelaje de Animal/microbiología , Animales , Bacterias/aislamiento & purificación , Carga Bacteriana , Recuento de Colonia Microbiana , Infección Hospitalaria/prevención & control , Infección Hospitalaria/transmisión , Desinfección , Contaminación de Equipos/prevención & control , Humanos , Masculino
5.
J Magn Reson Imaging ; 43(6): 1407-16, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26587694

RESUMEN

PURPOSE: To evaluate serial apparent diffusion coefficient (ADC) measurements of bone metastases in prostate cancer to determine whether antiandrogen resistance can be detected and time to progression estimated. MATERIALS AND METHODS: Diffusion-weighted imaging (DWI) was performed at 1.5T in nine patients with treatment-naïve metastatic prostate cancer (20 lesions) before antiandrogen treatment, after 1, 2, and 3 months of treatment, and thereafter every 4 months over 31 months or until antiandrogen resistance was detected. Tumor volumes were stable over time. Time courses of the ADCs when averaged over entire lesions and on functional diffusion maps (fDMs) were analyzed using marginal linear model (MLM) analysis. RESULTS: Starting at 1 month, MLM analysis revealed decreasing mean ADCs (P = 0.001) over time. Simultaneously, the percentage of voxels with significantly higher ADCs decreased (P = 0.004), whereas the percentage of voxels with significantly lower ADCs increased (P < 0.001) on fDMs. Both mean ADCs (P = 0.042) and percentages of voxels with significantly higher ADCs on fDMs (P = 0.039) decreased more rapidly over time in patients with a shorter progression-free interval (PFI). Likewise, higher (P = 0.001) and more rapidly increasing (P = 0.002) percentages of voxels with significantly lower ADCs on fDMs were associated with a shorter PFI. CONCLUSION: The results of our pilot study suggest that the evolution of ADCs over time may permit early identification of antiandrogen resistance in bone metastases. J. Magn. Reson. Imaging 2016;43:1407-1416.


Asunto(s)
Antagonistas de Andrógenos/administración & dosificación , Neoplasias Óseas/tratamiento farmacológico , Neoplasias Óseas/secundario , Imagen de Difusión por Resonancia Magnética/métodos , Monitoreo de Drogas/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Antineoplásicos/administración & dosificación , Neoplasias Óseas/patología , Resistencia a Antineoplásicos , Humanos , Masculino , Proyectos Piloto , Pronóstico , Neoplasias de la Próstata/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
6.
Eur Radiol ; 26(8): 2714-22, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26573682

RESUMEN

OBJECTIVE: To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. MATERIALS AND METHODS: The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. RESULTS: There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. CONCLUSION: Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. KEY POINTS: • A modified breathing command reduced respiratory artefacts on arterial-phase gadoxetate-enhanced MRI (P < 0.001). • The modified command decreased severe and extensive arterial-phase breathing artefacts (P = 0.021). • Training technicians to use a modified breathing command improved arterial-phase images.


Asunto(s)
Artefactos , Gadolinio DTPA/farmacología , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Respiración , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física)
7.
Eur Radiol ; 25(11): 3133-42, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26032878

RESUMEN

OBJECTIVE: Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. MATERIAL AND METHODS: The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. RESULTS: Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. CONCLUSION: Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. KEY POINTS: • Suction/Inspiration against resistance is promising to improve contrast density within the pulmonary artery. • Patients potentially suffering pulmonary embolism are able to follow suction/inspiration against resistance. • Contrast density after suction is superior in comparison to other breathing maneuvers.


Asunto(s)
Medios de Contraste/administración & dosificación , Arteria Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Tomografía Computarizada por Rayos X/métodos , Administración Intravenosa , Adulto , Anciano , Espiración/fisiología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Inhalación/fisiología , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Sistemas de Información Radiológica , Succión , Maniobra de Valsalva
8.
Eur Radiol ; 24(12): 3034-41, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25103533

RESUMEN

OBJECTIVES: Optimal contrast within the pulmonary artery is achieved by the maximum amount of contrast-enhanced blood flowing through the superior vena cava (SVC), while minimum amounts of non-contrasted blood should originate from the inferior vena cava (IVC). This study aims to clarify whether "suction against resistance" might optimise this ratio. METHODS: Phase-contrast pulse sequences on a 1.5T MRI magnet were used for flow quantification (mean flow (mL/s), stroke volume (Vol) in the SVC and IVC in volunteers. Different breathing manoeuvers were analysed repeatedly: free breathing; inspiration; expiration; suction against resistance, and Valsalva. To standardise breathing commands, volunteers performed suction and Valsalva manoeuvers with an MR-compatible manometer. RESULTS: Suction against resistance was associated with a significant drop of the IVC/SVC flow quotient (1.63 [range 1.3-2.0] p < 0.05 at -10 mmHg and 1.48 [1.1-1.9] p < 0.01 at -20 mmHg) corresponding to increased blood flow from SVC and diminished flow originating from the IVC. The remaining breathing commands (free breathing 2.2; inspiration 2.4; expiration 2.4; Valsalva 10 mmHg 2.3; Valsalva 20 mmHg 2.6; and Valsalva 30 mmHg 2.2) showed no differences (p > 0.05). CONCLUSIONS: Suction against resistance caused a significant drop in the IVC/SVC quotient. Theoretically, this breathing manoeuver might significantly improve the enhancement characteristics of CT angiography. KEY POINTS: Suction provokes reduction in blood flow in the inferior vena cava. Ratio between the inferior and superior vena cava blood flow diminished during suction. Manometer used during breathing standardises MR phase-contrast blood flow measurements.


Asunto(s)
Respiración , Vena Cava Inferior/fisiología , Vena Cava Superior/fisiología , Adulto , Análisis de Varianza , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Pulmonar/fisiología , Volumen Sistólico/fisiología , Succión , Maniobra de Valsalva/fisiología
9.
Neuroimage ; 66: 426-35, 2013 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-23110883

RESUMEN

Bootstrap methods have recently been introduced to diffusion-weighted magnetic resonance imaging to estimate the measurement uncertainty of ensuing diffusion parameters directly from the acquired data without the necessity to assume a noise model. These methods have been previously combined with deterministic streamline tractography algorithms to allow for the assessment of connection probabilities in the human brain. Thereby, the local noise induced disturbance in the diffusion data is accumulated additively due to the incremental progression of streamline tractography algorithms. Graph based approaches have been proposed to overcome this drawback of streamline techniques. For this reason, the bootstrap method is in the present work incorporated into a graph setup to derive a new probabilistic fiber tractography method, called BootGraph. The acquired data set is thereby converted into a weighted, undirected graph by defining a vertex in each voxel and edges between adjacent vertices. By means of the cone of uncertainty, which is derived using the wild bootstrap, a weight is thereafter assigned to each edge. Two path finding algorithms are subsequently applied to derive connection probabilities. While the first algorithm is based on the shortest path approach, the second algorithm takes all existing paths between two vertices into consideration. Tracking results are compared to an established algorithm based on the bootstrap method in combination with streamline fiber tractography and to another graph based algorithm. The BootGraph shows a very good performance in crossing situations with respect to false negatives and permits incorporating additional constraints, such as a curvature threshold. By inheriting the advantages of the bootstrap method and graph theory, the BootGraph method provides a computationally efficient and flexible probabilistic tractography setup to compute connection probability maps and virtual fiber pathways without the drawbacks of streamline tractography algorithms or the assumption of a noise distribution. Moreover, the BootGraph can be applied to common DTI data sets without further modifications and shows a high repeatability. Thus, it is very well suited for longitudinal studies and meta-studies based on DTI.


Asunto(s)
Algoritmos , Mapeo Encefálico/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión Tensora/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Humanos , Probabilidad
10.
Eur Addict Res ; 19(4): 184-93, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23257512

RESUMEN

The aim of this study was to clarify whether addiction-specific neurometabolic reaction patterns occur in the insular cortex during acute nicotine withdrawal in tobacco smokers in comparison to nonsmokers. Fourteen male smokers and 10 male nonsmokers were included. Neurometabolites of the right and the left insular cortices were quantified by magnetic resonance spectroscopy (MRS) on a 3-Tesla scanner. Three separate MRS measurements were performed in each subject: among the smokers, the first measurement was done during normal smoking behavior, the second measurement during acute withdrawal (after 24 h of smoking abstinence), and the third shortly after administration of an oral nicotine substitute. Simultaneously, craving, withdrawal symptoms, and CO levels in exhaled air were determined during the three phases. The participants in the control group underwent the same MR protocol. In the smokers, during withdrawal, the insular cortex showed a significant increase in glutamine (Gln; p = 0.023) as well as a slight increase not reaching significance for glutamine/glutamate (Glx; p = 0.085) and a nonsignificant drop in myoinositol (mI; p = 0.381). These values tended to normalize after oral nicotine substitution treatment, even though differences were not significant: Gln (p = 0.225), Glx (p = 0.107) and mI (p = 0.810). Overall, the nonsmokers (control group) did not show any metabolic changes over all three phases (p > 0.05). In smokers, acute nicotine withdrawal produces a neurometabolic reaction pattern that is partly reversed by the administration of an oral nicotine substitute. The results are consistent with the expression of an addiction-specific neurometabolic shift in the brain and confirm the fact that the insular cortex seems to play a possible role in nicotine dependence.


Asunto(s)
Corteza Cerebral/efectos de los fármacos , Corteza Cerebral/metabolismo , Neuroimagen Funcional , Nicotina/administración & dosificación , Fumar/metabolismo , Síndrome de Abstinencia a Sustancias/metabolismo , Dispositivos para Dejar de Fumar Tabaco , Administración Oral , Adulto , Conducta Adictiva/metabolismo , Monóxido de Carbono/metabolismo , Estudios de Casos y Controles , Ácido Glutámico/metabolismo , Glutamina/metabolismo , Humanos , Inositol/metabolismo , Masculino , Persona de Mediana Edad , Nicotina/efectos adversos , Nicotina/farmacología
11.
Magn Reson Med ; 67(3): 679-90, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21702067

RESUMEN

The potential signal-to-noise ratio (SNR) gain at ultrahigh field strengths offers the promise of higher image resolution in single-shot diffusion-weighted echo-planar imaging the challenge being reduced T(2) and T(2) * relaxation times and increased B(0) inhomogeneity which lead to geometric distortions and image blurring. These can be addressed using parallel imaging (PI) methods for which a greater range of feasible reduction factors has been predicted at ultrahigh field strengths-the tradeoff being an associated SNR loss. Using comprehensive simulations, the SNR of high-resolution diffusion-weighted echo-planar imaging in combination with spin-echo and stimulated-echo acquisition is explored at 7 T and compared to 3 T. To this end, PI performance is simulated for coil arrays with a variable number of circular coil elements. Beyond that, simulations of the point spread function are performed to investigate the actual image resolution. When higher PI reduction factors are applied at 7 T to address increased image distortions, high-resolution imaging benefits SNR-wise only at relatively low PI reduction factors. On the contrary, it features generally higher image resolutions than at 3 T due to smaller point spread functions. The SNR simulations are confirmed by phantom experiments. Finally, high-resolution in vivo images of a healthy volunteer are presented which demonstrate the feasibility of higher PI reduction factors at 7 T in practice.


Asunto(s)
Mapeo Encefálico/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Adulto , Simulación por Computador , Imagen Eco-Planar/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Modelos Teóricos , Fantasmas de Imagen , Relación Señal-Ruido
12.
J Magn Reson Imaging ; 36(4): 979-86, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22689529

RESUMEN

PURPOSE: To determine the precision for in vivo applications of model and non-model-based bootstrap algorithms for estimating the measurement uncertainty of diffusion parameters derived from diffusion tensor imaging data. MATERIALS AND METHODS: Four different bootstrap methods were applied to diffusion datasets acquired during 10 repeated imaging sessions. Measurement uncertainty was derived in eight manually selected regions of interest and in the entire brain white matter and gray matter. The precision of the bootstrap methods was analyzed using coefficients of variation and intra-class correlation coefficients. Comprehensive simulations were performed to validate the results. RESULTS: All bootstrap algorithms showed similar precision which slightly varied in dependence of the selected region of interest. The averaged coefficient of variation in the selected regions of interest was 13.81%, 12.35%, and 17.93% with respect to the apparent diffusion coefficient, the fractional anisotropy value, and the cone of uncertainty, respectively. The repeated measurements showed a very high similarity with intraclass-correlation coefficients larger than 0.96. The simulations confirmed most of the in vivo findings. CONCLUSION: All investigated bootstrap methods perform with a similar, high precision in deriving the measurement uncertainty of diffusion parameters. Thus, the time-efficient model-based bootstrap approaches should be the method of choice in clinical practice.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
J Magn Reson Imaging ; 36(4): 1002-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22550013

RESUMEN

PURPOSE: To optimize the diagnostic accuracy of the functional diffusion map for monitoring tumor treatment response in cancer patients. MATERIALS AND METHODS: Using Monte Carlo simulations, measurement precision of the apparent diffusion coefficient (ADC), and particularly accuracy of threshold determination from healthy reference tissue, are evaluated by investigating the repeatability limit of the ADC as a function of different degrees of diffusion weighting of the sequence. Phantom and in-vivo experiments are performed to verify and illustrate the results of the simulations. RESULTS: While diagnostic accuracy of the functional diffusion map is hardly diminished by differing values of the T(2) relaxation time in tumor and reference tissue, it is shown to be impaired by differing ADCs, resulting in erroneously determined segmentation thresholds. This problem can be addressed by decreasing the maximum b-factor and increasing the number of signal averages at the maximum b-factor or, alternatively, the number of b-factors while favoring schemes with higher b-factors. Phantom experiments confirm the results of the simulations. In-vivo data are presented to illustrate the effect of sequence optimization on the diagnostic accuracy of the functional diffusion map. CONCLUSION: The present work demonstrates that the diagnostic accuracy of the functional diffusion map can be impaired by inaccurate segmentation thresholds and derives means for its optimization that will increase the fidelity of future clinical studies.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Modelos Biológicos , Modelos Estadísticos , Simulación por Computador , Humanos , Método de Montecarlo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Sci Rep ; 11(1): 5506, 2021 03 09.
Artículo en Inglés | MEDLINE | ID: mdl-33750899

RESUMEN

We sought to evaluate the utility of radiomics for Amide Proton Transfer weighted (APTw) imaging by assessing its value in differentiating brain metastases from high- and low grade glial brain tumors. We retrospectively identified 48 treatment-naïve patients (10 WHO grade 2, 1 WHO grade 3, 10 WHO grade 4 primary glial brain tumors and 27 metastases) with either primary glial brain tumors or metastases who had undergone APTw MR imaging. After image analysis with radiomics feature extraction and post-processing, machine learning algorithms (multilayer perceptron machine learning algorithm; random forest classifier) with stratified tenfold cross validation were trained on features and were used to differentiate the brain neoplasms. The multilayer perceptron achieved an AUC of 0.836 (receiver operating characteristic curve) in differentiating primary glial brain tumors from metastases. The random forest classifier achieved an AUC of 0.868 in differentiating WHO grade 4 from WHO grade 2/3 primary glial brain tumors. For the differentiation of WHO grade 4 tumors from grade 2/3 tumors and metastases an average AUC of 0.797 was achieved. Our results indicate that the use of radiomics for APTw imaging is feasible and the differentiation of primary glial brain tumors from metastases is achievable with a high degree of accuracy.


Asunto(s)
Algoritmos , Neoplasias Encefálicas , Encéfalo , Glioma , Imagen por Resonancia Magnética , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Femenino , Glioma/diagnóstico por imagen , Glioma/patología , Humanos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia
15.
Br J Radiol ; 94(1121): 20200869, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33596102

RESUMEN

OBJECTIVES: Diffusion-weighted imaging (DWI) plays a crucial role in the diagnosis of ischemic stroke. We assessed the value of computed and acquired high b-value DWI in comparison with conventional b = 1000 s mm-2 DWI for ischemic stroke at 3T. METHODS: We included 36 patients with acute ischemic stroke who presented with diffusion abnormalities on DWI performed within 24 h of symptom onset. B-values of 0, 500, 1000 and 2000 s mm-2 were acquired. Synthetic images with b-values of 1000, 1500, 2000 and 2500 s mm-2 were computed. Two readers compared synthetic (syn) and acquired (acq) b = 2000 s mm-2 images with acquired b = 1000 s mm-2 images in terms of lesion detection rate, image quality, presence of uncertain hyperintensities and lesion conspicuity. Readers also selected their preferred b-value. Contrast ratio (CR) measurements were performed. Non-parametrical statistical tests and weighted Cohens' κ tests were computed. RESULTS: Syn1000 and syn1500 matched acq1000 images in terms of lesion detection rate, image quality and presence of uncertain hyperintensities but presented with significantly improved lesion conspicuity (p < 0.01) and were frequently selected as preferred b-values. Acq2000 images exhibited a similar lesion detection rate and improved lesion conspicuity (p < 0.01) but worse image quality (p < 0.01) than acq1000 images. Syn2000 and syn2500 images performed significantly worse (p < 0.01) than acq1000 images in most or all categories. CR significantly increased with increasing b-values. CONCLUSION: Synthetic images at b = 1000 and 1500 s mm-2 and acquired DWI images at b = 2000 s mm-2 may be of clinical value due to improved lesion conspicuity. ADVANCES IN KNOWLEDGE: Synthetic b-values enable improved lesion conspicuity for DWI of ischemic stroke.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Imagen de Difusión por Resonancia Magnética/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estándares de Referencia , Estudios Retrospectivos , Relación Señal-Ruido , Incertidumbre
16.
Radiology ; 257(2): 523-31, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20829534

RESUMEN

PURPOSE: To prospectively investigate and monitor the response to antiandrogen treatment of bone metastases in patients with prostate cancer by using diffusion-weighted (DW) magnetic resonance (MR) imaging with the apparent diffusion coefficient (ADC) and functional diffusion maps (DMs). MATERIALS AND METHODS: This study had institutional review board approval; informed consent was obtained from all patients. Nine treatment-naive men (mean age, 73 years; range, 66-86 years) with 20 pelvic bone metastases were included. Imaging was performed before antiandrogen treatment and at 1, 2, and 3 months afterward. Imaging included a DW MR imaging sequence with five b factors (0-800 sec/mm²). Serum prostate-specific antigen (PSA) levels and mean ADCs of each metastasis were measured over time and analyzed by using the general linear model. Pairwise comparisons (paired-samples t tests) of PSA levels and ADCs before and after therapy were performed with the significance level set at P < .017 (Bonferroni correction). To determine the relationship between serum PSA level and the averaged mean ADCs in each patient, the two parameters were correlated across time. In addition, an analysis with functional DMs was performed to evaluate ADC response to treatment on a per-voxel basis. RESULTS: Serum PSA levels decreased by more than 90% during therapy. The mean ADCs of metastases were increased significantly at 1 (P < .001), 2 (P = .002), and 3 (P = .011) months after therapy compared with pretreatment values. Heterogeneous response was revealed at functional DM analysis. After 1 month of therapy, 47.3% of all analyzed tumor voxels showed significantly increased ADCs, while 46.5% were unchanged and 6.2% exhibited decreased ADCs in comparison to the pretreatment values. At 3 months after therapy, the proportion of voxels showing ADC decrease was higher (13.7%) than that at 1 month. CONCLUSION: DW MR imaging allows monitoring of antiandrogen therapy in bone metastases. PSA level decrease corresponded well with an increase in mean tumor ADC. Heterogeneity of tumor response to therapy was demonstrated by functional DM analysis.


Asunto(s)
Neoplasias Óseas/secundario , Imagen de Difusión por Resonancia Magnética/métodos , Huesos Pélvicos/patología , Neoplasias de la Próstata/patología , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Antagonistas de Andrógenos/uso terapéutico , Neoplasias Óseas/diagnóstico por imagen , Humanos , Modelos Lineales , Masculino , Huesos Pélvicos/diagnóstico por imagen , Estudios Prospectivos , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/tratamiento farmacológico , Cintigrafía , Imagen de Cuerpo Entero
17.
Cancer Imaging ; 20(1): 18, 2020 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-32054513

RESUMEN

BACKGROUND: The aim of the study is to investigate how well patients remember the radiologist's name after a radiological examination, and whether giving the patient a business card improves the patient's perception of the radiologist's professionalism and esteem. METHODS: In this prospective and randomized two-centre study, a total of 141 patients with BI-RADS 1 and 2 scores were included. After screening examination comprising mammography and ultrasound by a radiologist, 71 patients received a business card (group 1), while 70 received no business card (group 2). Following the examination, patients were questioned about their experiences. RESULTS: The patients in group 1 could remember the name of the radiologist in 85% of cases. The patients in group 2, in contrast, could only remember the name in 7% of cases (p < 0.001). 90% of the patients in group 1 believed it was very important that they are able to contact the radiologist at a later time, whereas only 76% of patients in group 2 felt that this was a very important service (p < 0.025). A total of 87% of the patients in group 1 indicated that they would contact the radiologist if they had any questions whereas 73% of the patients in group 2 would like to contact the radiologist but were not able to do so, because they could not remember the name (p < 0.001). All questions were analysed with a Cochran-Mantel-Haenszel (CMH) test that took study centre as stratification into account. In some cases, two categories were collapsed to avoid zero cell counts. CONCLUSIONS: Using business cards significantly increased the recall of the radiologist's name and could be an important tool in improving the relationships between patients and radiologists and enhancing service professionalism. TRIAL REGISTRATION: We have a general approval from our ethics committee. The patients have given their consent to this study.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía , Profesionalismo , Radiólogos , Ultrasonografía Mamaria , Adulto , Anciano , Anciano de 80 o más Años , Detección Precoz del Cáncer , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos
18.
J Appl Physiol (1985) ; 107(3): 921-7, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19628727

RESUMEN

Several observations suggest that the transmission of myocardial forces is influenced in part by the spatial arrangement of the myocytes aggregated together within ventricular mass. Our aim was to assess, using diffusion tensor magnetic resonance imaging (DT-MRI), any differences in the three-dimensional arrangement of these myocytes in the normal heart compared with the hypertrophic murine myocardium. We induced ventricular hypertrophy in seven mice by infusion of angiotensin II through a subcutaneous pump, with seven other mice serving as controls. DT-MRI of explanted hearts was performed at 3.0 Tesla. We used the primary eigenvector in each voxel to determine the three-dimensional orientation of aggregated myocytes in respect to their helical angles and their transmural courses (intruding angles). Compared with controls, the hypertrophic hearts showed significant increases in myocardial mass and the outer radius of the left ventricular chamber (P < 0.05). In both groups, a significant change was noted from positive intruding angles at the base to negative angles at the ventricular apex (P < 0.01). Compared with controls, the hypertrophied hearts had significantly larger intruding angles of the aggregated myocytes, notably in the apical and basal slices (P < 0.001). In both groups, the helical angles were greatest in midventricular sections, albeit with significantly smaller angles in the mice with hypertrophied myocardium (P < 0.01). The use of DT-MRI revealed significant differences in helix and intruding angles of the myocytes in the mice with hypertrophied myocardium.


Asunto(s)
Cardiomegalia/patología , Agregación Celular/fisiología , Miocitos Cardíacos/patología , Angiotensina II/farmacología , Animales , Cardiomegalia/diagnóstico , Cardiomegalia/diagnóstico por imagen , Agregación Celular/efectos de los fármacos , Imagen de Difusión por Resonancia Magnética , Ratones , Ratones Endogámicos C57BL , Miocitos Cardíacos/efectos de los fármacos , Ultrasonografía , Vasoconstrictores/farmacología
19.
Neurol Res Int ; 2019: 7397491, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31827926

RESUMEN

OBJECTIVE: Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease with involvement of the upper and lower motor neurons. Since the loss of fine motor skills is one of the earliest signs of ALS, the hypothesis was tested if the nine hole PEG test (NHPT) and transcranial magnet stimulation (TMS) with resting-motor threshold (RMT) could be useful in monitoring disease progression. METHODS: We examined 28 ALS patients and 27 age-matched healthy controls. ALS patients and healthy controls underwent the nine hole peg test (NHPT) and TMS with RMT. Measurements in patients were repeated after three and six months. RESULTS: At baseline, the median NHPT durations were 1,4-fold longer (p < 0.001), and TMS scores showed a significant 0.8-fold smaller score in ALS patients compared with healthy controls (p < 0.001). The comparison of three and six months versus baseline revealed significant differences for NHPT durations and ALSFRS-R in patients, whereas TMS scores did not significantly differ in the patients. CONCLUSION: NHPT seems to be a good tool to evaluate dexterity of the hand and the progression of the disease in ALS patients. TMS RMT to the hand muscles seems to be poorly qualified to evaluate the dexterity of the hand function and the course of the disease.

20.
PLoS One ; 14(1): e0210473, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30653548

RESUMEN

OBJECTIVES: To assess the occurrence of transient interruption of contrast (TIC) phenomenon in pulmonary computed tomography angiography (CTPA) exams performed in inspiratory breath-hold after patients were told to inspire gently. METHODS: In this retrospective single-centre study, CTPA exams of 225 consecutive patients scanned on a 16-slice CT scanner system were analysed. A-priori to measurements, exams were screened for inadequate pulmonary artery contrast due to incorrect bolus tracking or failure of i.v. contrast administration. Those exams were excluded. Attenuation values in the thoracic aorta and in the pulmonary trunk were assessed in duplicate measurements (M1 and M2) and the aorto-pulmonary density ratio was calculated. An aorto-pulmonary ratio > 1 with still contrast inflow being visible within the superior vena cava was defined as TIC. RESULTS: 3 patients were excluded due to incorrect bolus tracking. Final analysis was performed in 222 patients (mean age 65 ± 19 years, range 18 to 99 years). Mean density in the pulmonary trunk was 275±17 HU, in the aorta 208 ± 15 HU. Mean aorto-pulmonary ratio was 0.81± 0.29. 48 patients (21.6%) had an aorto-pulmonary ratio >1. Correlation of mean aorto-pulmonary ratio and age was: -0.213 (p = 0.001). Age was not significantly different for an aorto-pulmonary ratio >1 vs. ≤1 (p = 0.122). Both in M1 and M2, 33/222 patients presented with absolute HU values of < 200 HU within the pulmonary artery. In M1 measurements, 24 of these 33 patients (72%) fulfilled TIC criteria (M2: 25/33 patients (75%)). CONCLUSIONS: TIC is a common phenomenon in CTPA studies with inspiratory breath-hold commands after patients were told to inspire gently with an incidence of 22% in our retrospective cohort. Occurrence of TIC shows a significant negative correlation with increasing age and disproportionately often occurs in patients with lower absolute contrast density values within their pulmonary arteries.


Asunto(s)
Contencion de la Respiración , Angiografía por Tomografía Computarizada/métodos , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Vena Cava Superior/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Medios de Contraste , Femenino , Humanos , Incidencia , Inhalación , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA