Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Lancet ; 393(10190): 2503-2510, 2019 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-31056295

RESUMEN

BACKGROUND: New-generation drug-eluting stents (DES) have mostly been investigated in head-to-head non-inferiority trials against early-generation DES and have typically shown similar efficacy and superior safety. How the safety profile of new-generation DES compares with that of bare-metal stents (BMS) is less clear. METHODS: We did an individual patient data meta-analysis of randomised clinical trials to compare outcomes after implantation of new-generation DES or BMS among patients undergoing percutaneous coronary intervention. The primary outcome was the composite of cardiac death or myocardial infarction. Data were pooled in a one-stage random-effects meta-analysis and examined at maximum follow-up and a 1-year landmark. Risk estimates are reported as hazard ratios (HRs) with 95% CIs. This study is registered in PROSPERO, number CRD42017060520. FINDINGS: We obtained individual data for 26 616 patients in 20 randomised trials. Mean follow-up was 3·2 (SD 1·8) years. The risk of the primary outcome was reduced in DES recipients compared with BMS recipients (HR 0·84, 95% CI 0·78-0·90, p<0·001) owing to a reduced risk of myocardial infarction (0·79, 0·71-0·88, p<0·001) and a possible slight but non-significant cardiac mortality benefit (0·89, 0·78-1·01, p=0·075). All-cause death was unaffected (HR with DES 0·96, 95% CI 0·88-1·05, p=0·358), but risk was lowered for definite stent thrombosis (0·63, 0·50-0·80, p<0·001) and target-vessel revascularisation (0·55, 0·50-0·60, p<0·001). We saw a time-dependent treatment effect, with DES being associated with lower risk of the primary outcome than BMS up to 1 year after placement. While the effect was maintained in the longer term, there was no further divergence from BMS after 1 year. INTERPRETATION: The performance of new-generation DES in the first year after implantation means that BMS should no longer be considered the gold standard for safety. Further development of DES technology should target improvements in clinical outcomes beyond 1 year. FUNDING: Bern University Hospital.


Asunto(s)
Infarto del Miocardio/cirugía , Intervención Coronaria Percutánea/instrumentación , Stents/efectos adversos , Anciano , Anciano de 80 o más Años , Stents Liberadores de Fármacos/efectos adversos , Estudios de Equivalencia como Asunto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Oportunidad Relativa , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 82(7): E856-63, 2013 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-23239630

RESUMEN

INTRODUCTION: The safety and effectiveness of drug-eluting stent (DES) compared with bare metal stents (BMS) for the treatment of saphenous vein graft (SVG) disease is controversial, especially because of the lack of long-term follow-up. The aim of this study was to address the late outcome of DES versus BMS for the treatment of SVG lesions. METHODS: A matched, case-control study included 82 patients in each group. Patients groups were matched by gender, age, clinical presentation, and diabetes. The primary study end point was occurrence of major adverse cardiovascular events (MACE). Secondary end points included death, cardiac death, myocardial infarction (MI), and target vessel revascularization (TVR). RESULTS: Clinical and angiographic characteristics were similar between the groups. At 6 months, TVR (hazard ratio [HR] 6.12, 95% confidence interval [CI] 1.39 to 26.93, P = 0.05), and MACE (HR 2.54, 95% CI 1.08 to 5.98, P = 0.04) were higher in the BMS group. At 4 years the risks of MI (P = 0.21), TVR (P = 0.99), and MACE (P = 0.21) were similar between both groups. However, the rates of death (HR 2.74, 95% CI 1.11 to 6.74, P = 0.04) and cardiac death (HR 4.26, 95% CI 1.59 to 11.35, P = 0.01) were significantly higher in the BMS group. CONCLUSIONS: These results suggest that the use of DES compared with BMS in the treatment of SVG lesions reduces TVR and MACE at 6 months of follow-up, a benefit that was lost over the next 3-4 years.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/terapia , Metales , Intervención Coronaria Percutánea/instrumentación , Vena Safena/cirugía , Stents , Anciano , Angiografía Coronaria , Puente de Arteria Coronaria/mortalidad , Femenino , Oclusión de Injerto Vascular/diagnóstico , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/mortalidad , Oclusión de Injerto Vascular/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Vena Safena/diagnóstico por imagen , Vena Safena/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 79(2): 243-52, 2012 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21542121

RESUMEN

OBJECTIVE: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous™ endothelial progenitor cell capturing R stent™ placement in patients from the e-HEALING registry. BACKGROUND: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. METHODS: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. RESULTS: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.65-1.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.55-1.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. CONCLUSIONS: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Revascularización Miocárdica/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Vigilancia de Productos Comercializados/estadística & datos numéricos , Anciano , Bioingeniería , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Resultado del Tratamiento
4.
Heart Vessels ; 27(4): 360-9, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21725668

RESUMEN

The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter ≥3 mm and lesion length ≤15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter <3.0 mm or lesion length >15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with ≥1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/normas , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/terapia , Vasos Coronarios/patología , Células Endoteliales/patología , Agencias Gubernamentales/normas , Células Madre/patología , Stents/normas , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Anticuerpos/administración & dosificación , Antígenos CD34/inmunología , Materiales Biocompatibles Revestidos/normas , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Reestenosis Coronaria/patología , Estenosis Coronaria/mortalidad , Estenosis Coronaria/patología , Vasos Coronarios/inmunología , Células Endoteliales/inmunología , Femenino , Adhesión a Directriz/normas , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Neointima , Selección de Paciente , Guías de Práctica Clínica como Asunto/normas , Vigilancia de Productos Comercializados , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Células Madre/inmunología , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
5.
Am J Cardiol ; 182: 8-16, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36075755

RESUMEN

New-generation drug-eluting stents (DES) strongly reduce restenosis and repeat revascularization compared with bare-metal stents (BMS) for percutaneous coronary intervention. There is residual uncertainty as to whether other prognostically relevant outcomes are affected by DES versus BMS concerning initial presentation (chronic coronary syndrome [CCS] vs acute coronary syndrome [ACS]). We performed an individual patient data meta-analysis of randomized trials comparing new-generation DES versus BMS (CRD42017060520). The primary outcome was the composite of cardiac death or myocardial infarction (MI). Outcomes were examined at maximum follow-up and with a 1-year landmark. Risk estimates are expressed as hazard ratio (HR) with 95% confidence interval (CI). A total of 22,319 patients were included across 14 trials; 7,691 patients (34.5%) with CCS and 14,628 patients (65.5%) with ACS. We found evidence that new-generation DES versus BMS consistently reduced the risk of cardiac death or MI in both patients with CCS (HR 0.83, 95% CI 0.70 to 0.98, p <0.001) and ACS (HR 0.83, 95% CI 0.75 to 0.92, p <0.001) (p-interaction = 0.931). This benefit was mainly driven by a similar reduction in the risk of MI (p-interaction = 0.898) for both subsets (HRCCS 0.80, 95% CI 0.65 to 0.97; HRACS 0.79, 95% CI 0.70 to 0.89). In CCS and ACS, we found a time-dependent treatment effect, with the benefit from DES accumulating during 1-year follow-up, without offsetting effects after that. In conclusion, patients with CCS were slightly underrepresented in comparative clinical trials. Still, they benefited similarly to patients with ACS from new-generation DES instead of BMS with a sustained reduction of cardiac death or MI because of lower event rates within 1 year.


Asunto(s)
Síndrome Coronario Agudo , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Síndrome Coronario Agudo/complicaciones , Muerte , Stents Liberadores de Fármacos/efectos adversos , Humanos , Metales , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Stents/efectos adversos , Resultado del Tratamiento
6.
Circulation ; 122(10): 949-57, 2010 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-20733102

RESUMEN

BACKGROUND: This study compared the 10-year follow-up of percutaneous coronary intervention (PCI), coronary artery surgery (CABG), and medical treatment (MT) in patients with multivessel coronary artery disease, stable angina, and preserved ventricular function. METHODS AND RESULTS: The primary end points were overall mortality, Q-wave myocardial infarction, or refractory angina that required revascularization. All data were analyzed according to the intention-to-treat principle. At a single institution, 611 patients were randomly assigned to CABG (n=203), PCI (n=205), or MT (n=203). The 10-year survival rates were 74.9% with CABG, 75.1% with PCI, and 69% with MT (P=0.089). The 10-year rates of myocardial infarction were 10.3% with CABG, 13.3% with PCI, and 20.7% with MT (P<0.010). The 10-year rates of additional revascularizations were 7.4% with CABG, 41.9% with PCI, and 39.4% with MT (P<0.001). Relative to the composite end point, Cox regression analysis showed a higher incidence of primary events in MT than in CABG (hazard ratio 2.35, 95% confidence interval 1.78 to 3.11) and in PCI than in CABG (hazard ratio 1.85, 95% confidence interval 1.39 to 2.47). Furthermore, 10-year rates of freedom from angina were 64% with CABG, 59% with PCI, and 43% with MT (P<0.001). CONCLUSIONS: Compared with CABG, MT was associated with a significantly higher incidence of subsequent myocardial infarction, a higher rate of additional revascularization, a higher incidence of cardiac death, and consequently a 2.29-fold increased risk of combined events. PCI was associated with an increased need for further revascularization, a higher incidence of myocardial infarction, and a 1.46-fold increased risk of combined events compared with CABG. Additionally, CABG was better than MT at eliminating anginal symptoms. Clinical Trial Registration Information- URL: http://www.controlled-trials.com. REGISTRATION NUMBER: ISRCTN66068876.


Asunto(s)
Angioplastia Coronaria con Balón , Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Vasodilatadores/uso terapéutico , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Angioplastia Coronaria con Balón/mortalidad , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Bloqueadores de los Canales de Calcio/uso terapéutico , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Supervivencia sin Enfermedad , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
7.
J Interv Cardiol ; 24(4): 285-94, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21281358

RESUMEN

OBJECTIVES: We compared 12-month outcomes, regarding ischemic events, repeat intervention, and ST, between diabetic and nondiabetic patients treated with the Genous™ EPC capturing R stent™ during routine nonurgent percutaneous coronary intervention (PCI) using data from the multicenter, prospective worldwide e-HEALING registry. BACKGROUND: Diabetic patients have an increased risk for restenosis and stent thrombosis (ST). METHODS: In the 4,996 patient e-HEALING registry, 273 were insulin requiring diabetics (IRD), 963 were non-IRD (NIRD), and 3,703 were nondiabetics. The 12-month primary outcome was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction (MI) and target vessel revascularization. Secondary outcomes were the composite of cardiac death, MI or target lesion revascularization (TLR), and individual outcomes including ST. Cumulative event rates were estimated with the Kaplan-Meier method and compared with a log-rank test. RESULTS: TVF rates were respectively 13.4% in IRD, 9.0% in NIRD, and 7.9% in nondiabetics (P < 0.01). This was mainly driven by a higher mortality hazard in IRD (P < 0.001) and NIRD (P = 0.07), compared with nondiabetics. TLR rates were comparable in NIRD and nondiabetics, but significantly higher in IRD (P = 0.04). No difference was observed in ST. CONCLUSION: The 1-year results of the Genous stent in a real-world population of diabetics show higher TVF rates in diabetics compared with nondiabetics, mainly driven by a higher mortality hazard. IRD is associated with a significant higher TLR hazard. Definite or probable ST in all diabetic patients was comparable with nondiabetics. (J Interven Cardiol 2011;24:285-294).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 2/complicaciones , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/prevención & control , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Insuficiencia del Tratamiento , Resultado del Tratamiento
8.
Circ J ; 75(11): 2590-7, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21914961

RESUMEN

BACKGROUND: We evaluated the Genous™ Bio-engineered R stent™ in elderly patients undergoing non-urgent percutaneous coronary intervention. The elderly have an increased risk of (temporary) discontinuation of clopidogrel, which is associated with a higher risk of developing stent thrombosis (ST). METHODS AND RESULTS: In the e-HEALING registry, 2,651 patients were <65, 1,403 were 65-74 and 869 were ≥ 75 years old. The 12-month primary outcome was target vessel failure (TVF), defined as target vessel-related car-diac death or myocardial infarction and target vessel revascularization. Secondary outcomes included target lesion revascularization (TLR) and ST. Cumulative event rates were estimated with the Kaplan-Meier method and compared with a log-rank test. TVF occurred significantly more often in elderly patients compared with younger patients (7.0% in patients aged < 65, 8.8% in patients aged 65-74 and 11.7% in patients aged ≥ 75 years, P<0.001). There was a trend to higher TLR with increasing age (log-rank P=0.06) and no difference in ST. CONCLUSIONS: The 1-year results of the Genous stent in a population of elderly patients show a significantly higher TVF rate compared with younger patients, mainly driven by a higher mortality. Although there was a trend to higher TLR rates with increasing age, there was no difference in ST. This attests to the safety of this therapy for the elderly, in whom there could be concerns with administering long-term dual antiplatelet therapy.


Asunto(s)
Prótesis Vascular/efectos adversos , Infarto del Miocardio , Vigilancia de Productos Comercializados , Sistema de Registros , Stents/efectos adversos , Trombosis , Factores de Edad , Anciano , Angioplastia Coronaria con Balón , Clopidogrel , Muerte , Femenino , Humanos , Masculino , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Factores de Riesgo , Trombosis/etiología , Trombosis/mortalidad , Trombosis/prevención & control , Ticlopidina/administración & dosificación , Ticlopidina/análogos & derivados
9.
J Cardiol Cases ; 23(1): 16-19, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33437334

RESUMEN

Coronary artery fistulas, although rare, should be included in the differential diagnosis of atypical chest pain, generally unveiled by cardiac catheterization or multidetector computed tomography. Such anatomical findings in conjunction with detectable ischemia and severe symptoms should prompt their closure. Transcatheter closure of fistulas is an attractive alternative to surgery, especially with the novel devices such as the interlock fibered detachable coils, which can be safely and effectively performed in a variety of circumstances, including the coronary arteries with tortuous anatomies. We present a case of atypical chest pain and large burden of ischemia in the stress scintigraphy, due to multiple coronary fistulas to the bronchial arteries successfully occluded with percutaneous interlock coils. .

10.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33402278

RESUMEN

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros , Diseño de Prótesis , Resultado del Tratamiento
11.
Am J Case Rep ; 22: e931561, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-34465715

RESUMEN

BACKGROUND Coronary artery anomalies (CAAs) are rare congenital malformations with different clinical presentations and pathophysiological mechanisms. These anomalies are frequently the cause of sudden death in young patients. Most CAAs are incidental findings owing to the lack of symptoms; however, they may be associated with acute coronary syndrome in rare cases. CASE REPORT We describe the case of a 47-year-old man who presented with a 1-day history of progressive typical chest pain and elevated troponin levels. The patient underwent a coronary angiography, which unveiled the anomalous origin of the left main coronary artery arising from the right coronary artery, with an interarterial course between the ascending aorta and the pulmonary artery, without coronary artery disease. Coronary computed tomography angiography confirmed the CAA and its relationship with the symptoms. An uneventful coronary artery bypass graft was undertaken, and at the 1-year follow-up, the patient was asymptomatic, with a normal stress test. CONCLUSIONS This case depicts the presentation of atypical acute coronary syndrome in a young patient with a rare CAA. In such patients, coronary angiography and coronary computed tomography angiography are essential tools to confirm the diagnosis and to determine treatment. Although controversial, in young individuals presenting CAA with an interarterial course, such as the left main coronary artery arising from the right coronary artery, coronary artery bypass graft may be an important treatment option to avoid sudden death in the future.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Anomalías de los Vasos Coronarios , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/etiología , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad
12.
J Am Heart Assoc ; 10(20): e018828, 2021 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-34622669

RESUMEN

Background New-generation drug-eluting stents (DES) reduce target-vessel revascularization compared with bare-metal stents (BMS), and recent data suggest that DES have the potential to decrease the risk of myocardial infarction and cardiovascular mortality. We evaluated the treatment effect of DES versus BMS according to the target artery (left anterior descending [LAD] and/or left main [LM] versus other territories [no-LAD/LM]). Methods and Results The Coronary Stent Trialist (CST) Collaboration gathered individual patient data of randomized trials of DES versus BMS for the treatment of coronary artery disease. The primary outcome was the composite of cardiac death or myocardial infarction. Hazard ratios (HRs) with 95% CIs were derived from a 1-stage individual patient data meta-analysis. We included 26 024 patients across 19 trials: 13 650 (52.4%) in the LAD/LM and 12 373 (47.6%) in the no-LAD/LM group. At 6-year follow-up, there was strong evidence that the treatment effect of DES versus BMS depended on the target vessel (P-interaction=0.024). Compared with BMS, DES reduced the risk of cardiac death or myocardial infarction to a greater extent in the LAD/LM (HR, 0.76; 95% CI, 0.68-0.85) than in the no-LAD/LM territories (HR, 0.93; 95% CI, 0.83-1.05). This benefit was driven by a lower risk of cardiac death (HR, 0.83; 95% CI, 0.70-0.98) and myocardial infarction (HR, 0.74; 95% CI, 0.65-0.85) in patients with LAD/LM disease randomized to DES. An interaction (P=0.004) was also found for all-cause mortality with patients with LAD/LM disease deriving benefit from DES (HR, 0.86; 95% CI, 0.76-0.97). Conclusions As compared with BMS, new-generation DES were associated with sustained reduction in the composite of cardiac death or myocardial infarction if used for the treatment of LAD or left main coronary stenoses. Registration URL: https://www.crd.york.ac.uk/PROSPERO; Unique identifier: CRD42017060520.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/terapia , Muerte , Humanos , Metales , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Stents , Resultado del Tratamiento
13.
JACC Cardiovasc Interv ; 13(19): 2251-2262, 2020 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-32950419

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the hypothesis that prasugrel monotherapy following successful everolimus-eluting stent implantation is feasible and safe in patients with stable coronary artery disease (CAD). BACKGROUND: Recent studies have suggested that short dual-antiplatelet therapy strategies may provide an adequate balance between ischemic and bleeding risks. However, the complete omission of aspirin immediately after percutaneous coronary intervention (PCI) has not been tested so far. METHODS: The study was a multicenter, single-arm, open-label trial with a stopping rule based on the occurrence of definite stent thrombosis (if >3, trial enrollment would be terminated). Patients undergoing successful everolimus-eluting stent implantation for stable CAD with SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) scores <23 were included. All participants were on standard dual-antiplatelet therapy at the time of index PCI. Aspirin was discontinued on the day of the index procedure but given prior to the procedure; prasugrel was administered in the catheterization laboratory immediately after the successful procedure, and aspirin-free prasugrel became the therapy regimen from that moment. Patients were treated solely with prasugrel for 3 months. The primary ischemic endpoint was the composite of cardiac death, spontaneous target vessel myocardial infarction, or definite stent thrombosis, and the primary bleeding endpoint was Bleeding Academic Research Consortium types 3 and 5 bleeding up to 3 months. RESULTS: From February 22, 2018, to May 7, 2019, 201 patients were enrolled. All patients underwent PCI for stable CAD. Overall, 98.5% of patients were adherent to prasugrel at 3-month follow-up. The primary ischemic and bleeding endpoints occurred in 1 patient (0.5%). No stent thrombosis events occurred. CONCLUSIONS: Aspirin-free prasugrel monotherapy following successful everolimus-eluting stent implantation demonstrated feasibility and safety without any stent thrombosis in selected low-risk patients with stable CAD. These findings may help underpin larger randomized controlled studies to evaluate the aspirin-free strategy compared with traditional dual-antiplatelet therapy following PCI. (Acetyl Salicylic Elimination Trial: The ASET Pilot Study [ASET]; NCT03469856).


Asunto(s)
Enfermedad de la Arteria Coronaria , Aspirina , Stents Liberadores de Fármacos , Humanos , Intervención Coronaria Percutánea , Proyectos Piloto , Inhibidores de Agregación Plaquetaria , Clorhidrato de Prasugrel , Resultado del Tratamiento
14.
Catheter Cardiovasc Interv ; 74(5): 665-73, 2009 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-19670303

RESUMEN

OBJECTIVES: We tested two novel drug-eluting stents (DES), covered with a biodegradable-polymer carrier and releasing paclitaxel or sirolimus, which were compared against a bare metal stent (primary objective). The DES differed by the drug, but were identical otherwise, allowing to compare the anti-restenosis effects of sirolimus versus paclitaxel (secondary objective). BACKGROUND: The efficacy of novel DES with biodegradable polymers should be tested in the context of randomized trials, even when using drugs known to be effective, such as sirolimus and paclitaxel. METHODS: Overall, 274 patients with de novo coronary lesions in native vessels scheduled for stent implantation were randomly assigned (2:2:1 ratio) for the paclitaxel (n = 111), sirolimus (n = 106), or bare metal stent (n = 57) groups. Angiographic follow-up was obtained at 9 months and major cardiac adverse events up to 12 months. RESULTS: Both paclitaxel and sirolimus stents reduced the 9-month in-stent late loss (0.54-0.44 mm, 0.32-0.43 mm, vs. 0.90-0.45 mm respectively), and 1-year risk of target vessel revascularization and combined major adverse cardiac events (P < 0.05 for both, in all comparisons), compared with controls. Sirolimus stents had lower late loss than paclitaxel stents (P < 0.01), but similar 1-year clinical outcomes. There were no differences in the risk of death, infarction, or stent thrombosis among the study groups. CONCLUSION: Both novel DES were effective in reducing neointimal hyperplasia and 1-year re-intervention, compared to bare metal stents. Our findings also suggest that sirolimus is more effective than paclitaxel in reducing angiographic neointima, although this effect was not associated with better clinical outcomes.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Enfermedades Cardiovasculares/prevención & control , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Metales , Paclitaxel/administración & dosificación , Sirolimus/administración & dosificación , Stents , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Brasil/epidemiología , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Angiografía Coronaria , Reestenosis Coronaria/etiología , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Hiperplasia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/prevención & control , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Medición de Riesgo , Trombosis/etiología , Trombosis/prevención & control , Factores de Tiempo , Resultado del Tratamiento
15.
J Am Coll Cardiol ; 72(23 Pt A): 2826-2837, 2018 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-30522646

RESUMEN

BACKGROUND: Diabetes mellitus (DM) is associated with complex coronary artery disease (CAD), which in turn results in increased morbidity and mortality from cardiovascular disease. OBJECTIVES: This study sought to evaluate the utility of SYNTAX score (SS) for predicting future cardiovascular events in patients with DM and complex CAD undergoing either coronary artery bypass grafting (CABG) or percutaneous coronary intervention (PCI). METHODS: The FREEDOM (Future REvascularization Evaluation in patients with Diabetes mellitus: Optimal management of Multivessel disease) trial randomized patients with DM and multivessel CAD to undergo either PCI with drug-eluting stents or CABG. The SS was calculated retrospectively by a core laboratory. The endpoint of hard cardiovascular events (HCE) was a composite of death from any cause, nonfatal myocardial infarction, and nonfatal stroke, while the endpoint of major adverse cardiac and cerebrovascular events (MACCE) was a composite of HCE and repeat revascularization. RESULTS: A total of 1,900 patients were randomized to PCI (n = 953) or CABG (n = 947). The SS was considered an independent predictor of 5-year MACCE (hazard ratio per unit of SS: 1.02; 95% confidence interval: 1.00 to 1.03; p = 0.014) and HCE (hazard ratio per unit of SS: 1.03; 95% confidence interval: 1.01 to 1.04; p = 0.002) in the PCI cohort, but not in the CABG group. There was a higher incidence of MACCE in PCI patients with low, intermediate, and high SS compared with those who underwent CABG (36.6% vs. 25.9%, p = 0.02; 43.9% vs. 26.8%, p < 0.001; 48.7% vs. 29.7%, p = 0.003, respectively). CONCLUSIONS: In DM patients with multivessel CAD, the complexity of CAD evaluated by the SS is an independent risk factor for MACCE and HCE only in patients undergoing PCI. The SS should not be utilized to guide the choice of coronary revascularization in patients with DM and multivessel CAD. (Comparison of Two Treatments for Multivessel Coronary Artery Disease in Individuals With Diabetes [FREEDOM]; NCT00086450).


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/cirugía , Revascularización Miocárdica/tendencias , Intervención Coronaria Percutánea/tendencias , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Diabetes Mellitus/fisiopatología , Stents Liberadores de Fármacos/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Revascularización Miocárdica/métodos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
16.
Int J Cardiol ; 267: 13-15, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-29861104

RESUMEN

BACKGROUND: The National Cardiovascular Data Registry (NCDR®) Database is commonly used for quality-improvement initiatives in North America, but little is known about the application of this tool in other regions of the world. METHODS: All consecutive patients admitted due to myocardial infarction (MI) and/or undergoing percutaneous coronary intervention (PCI) from January 2012 until December 2015 in a Brazilian private cardiovascular hospital were included respectively in ACTION REGISTRY®-GWTG™ and CathPCI Registry®. Meetings including all hospital staff were performed quarterly to discuss every NCDR® report. Quality improvement initiatives were developed based on the reports which were also used for evaluation of changes after the interventions. The following indicators were considered a priority 1) Door-to-ECG and door-to-balloon (D2B) times; 2) PCI appropriateness; 3) length of stay; 4) delivery of guideline-based medication. Changes in the quality of care with respect to the over time were assessed using linear and logistic regression for continuous and binary outcomes, respectively. RESULTS: A total of 1.382 patients were included in the ACTION REGISTRY®-GWTG™ and 3.179 patients in the CathPCI Registry®. In the ACTION registry, the overall AMI performance composite of quality indicators improved along the 4 years from 95.0% to 99.6% (p for trend <0.001). The percentage of appropriate/uncertain PCI in acute and elective scenario increased along the years from 91.1% and 70.9% to 96.6% and 84.7%, respectively (p for trend <0.001). CONCLUSION: The present novel experience using the NCDR® registries as benchmarks to guide quality-improvement programs in an international site was associated with improvement in quality indicators.


Asunto(s)
Procedimientos Quirúrgicos Electivos/estadística & datos numéricos , Infarto del Miocardio , Intervención Coronaria Percutánea , Mejoramiento de la Calidad/organización & administración , Indicadores de Calidad de la Atención de Salud/normas , Anciano , Brasil/epidemiología , Femenino , Mortalidad Hospitalaria , Hospitalización/estadística & datos numéricos , Humanos , Tiempo de Internación/estadística & datos numéricos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/epidemiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo , Tiempo de Tratamiento/normas , Tiempo de Tratamiento/estadística & datos numéricos
17.
Case Rep Cardiol ; 2016: 4865439, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26881143

RESUMEN

Primary cardiac tumors are rare and approximately half of them are atrial myxomas. They rarely remain asymptomatic, especially if large. The imaging of a myxoma by contrast dye during coronary angiography is an infrequent sign, which clarifies the vascular supply of the tumor. We report herein an interesting and rare case of a left atrial myxoma hypervascularized from the right coronary artery.

18.
Cardiovasc Diagn Ther ; 6(1): 87-91, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26885496

RESUMEN

Coronary artery anomalies (CAA) are congenital changes in their origin, course, and/or structure. Intercoronary communication (ICC) is a very rare subset with uni- or bidirectional blood flow between two or more coronary arteries. We present the case of a 58-year-old man with an acute coronary syndrome whose coronary angiography incidentally showed a surprising and very rare communication between the right coronary and left circumflex arteries.

19.
Case Rep Cardiol ; 2015: 580543, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25949831

RESUMEN

Coronary artery anomalies are congenital changes in their origin, course, and/or structure. They are the second most frequent cause of sudden death in young athletes. Dual LAD artery is a rare coronary anomaly. We present the case of a 44-year-old man with recent onset exertional angina and documented ischemia whose coronary angiogram and computed tomography (CT) showed type 4 dual LAD artery, the rarest and most interesting variant.

20.
Case Rep Cardiol ; 2015: 703646, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26451260

RESUMEN

Aneurysms of the sinus of Valsalva are very rare and mostly located in the right coronary sinus. They might course with dyspnea, fatigue, and acute coronary syndromes. We present herein an extremely rare case report of a 61-year-old woman diagnosed with external left main coronary compression by a giant aneurysm of the left sinus of Valsalva, which was successfully managed with percutaneous coronary intervention.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA