Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Z Gastroenterol ; 61(4): 411-419, 2023 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-35878607

RESUMEN

The increased risk of thrombosis and bleeding with an active tumor disease is known as the so-called "thrombo-hemorrhagic syndrome", which places high demands on anticoagulation. There are currently 4 randomized, prospective studies on the use of new, non-vitamin K dependent oral anticoagulants (NOAC) for the treatment of venous thromboembolism (VTE) that have occurred in oncology. The FXa inhibitors rivaroxaban, edoxaban and twice apixaban were each used in individual studies versus the standard therapeutic agent dalteparin. Since there is no direct head-to-head comparison of the FXa inhibitors mentioned within a study, the largest study - always compared to dalteparin - was evaluated for each NOAC. The studies were analyzed with regard to their effectiveness, safety, fatal bleeding rates, the risk of gastrointestinal bleeding (GIB) and other differences using descriptive statistics. With dalteparin, the mean VTE recurrence rate was approximately 9% over a 6-month treatment period. All three FXa inhibitors were not inferior to dalteparin in terms of potency. The VTE recurrence rate was - 2.3% lower in edoxaban and apixaban-treated patients and - 5.0% in rivaroxaban-treated patients. In terms of safety, there was an increased rate of severe bleeding (both + 2.4%) for rivaroxaban and edoxaban compared to dalteparin; in particular, the number of GIBs was significantly increased. In contrast, the number of severe bleeding was not increased for apixaban, as was the case for various bleeding types including GIB. In the Apixaban study, the overall rate of severe GIB, which accounted for about 50% of all severe bleeding, and that of clinically relevant non-severe bleeding, were the lowest. The FXa inhibitors are not inferior to the standard therapy with dalteparin in the VTE recurrence rate in oncological patients. The GIB rate appears to be an important predictive factor for the safety of this group of substances, so that tumor location, gastrointestinal risk factors and other individual criteria should be given greater consideration in future therapy decisions for or against an FXa inhibitor.


Asunto(s)
Neoplasias , Tromboembolia Venosa , Humanos , Anticoagulantes , Dalteparina/efectos adversos , Inhibidores del Factor Xa/efectos adversos , Rivaroxabán/uso terapéutico , Tromboembolia Venosa/tratamiento farmacológico , Estudios Prospectivos , Hemorragia Gastrointestinal
2.
Laryngorhinootologie ; 98(1): 21-26, 2019 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-30620965

RESUMEN

Compared to the general population, cancer patients are at increased risk for venous thromboembolism with significant impact on morbidity and mortality. Appropriate prophylaxis as well as early diagnosis and treatment are therefore mandatory. However, anticoagulation of cancer patients is associated with an increased risk of bleeding and recurrence. To meet these challenges, national and international guidelines for the prevention and treatment of venous thromboembolism in patients with cancer have been published. We provide a summary of these specific recommendations.


Asunto(s)
Anticoagulantes/efectos adversos , Hemorragia/inducido químicamente , Neoplasias/complicaciones , Tromboembolia Venosa/prevención & control , Humanos , Guías de Práctica Clínica como Asunto , Factores de Riesgo
3.
Transfusion ; 58(12): 2886-2893, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30325043

RESUMEN

BACKGROUND: RNA viruses are associated with a high frequency of mutations because of the missing proofreading function of polymerases, such as reverse transcriptase. Between 2007 and 2010, six blood donations with false-negative nucleic acid technology (NAT) results were reported in Germany. Therefore, NAT screening in two viral genome regions was introduced by our blood donation service in 2010 on a voluntary basis and became mandatory in Germany since the beginning of 2015. STUDY DESIGN AND METHODS: Blood donor screening was done using, in parallel, the German Red Cross (GRC) HIV-1 CE long terminate repeats (LTR) PCR kit and the GRC HIV-1 gag CE PCR kit. In total, 7 million blood donations were screened during the study period from 2010 to 2014 with the GRC dual-target human immunodeficiency virus 1 (HIV-1) NAT system. Additionally, three suspicious specimens were analyzed by four monotargeted NAT assays and by five dual-target NAT assays. RESULTS: Three of 7 million donations tested negative using the 5'LTR-polymerase chain reaction, but they were positive if amplification was performed in the gag region. HIV antibodies were detected in all three donations. Nucleic acid sequence analysis identified a deletion of 22 bases within the 5'LTR probe binding region. Three different ltr-based monotargeted assays missed two donations, except for a low-reactive result obtained by one of the assays. In total, the detection rates for HIV-1-positive donations were 37.5% (3/8) for monotargeted assays and 100% (10/10) for dual-target assays. CONCLUSION: The current data demonstrate that dual-target NAT systems reduce the risk of false-negative HIV-1 NAT screening results.


Asunto(s)
Donantes de Sangre , Duplicado del Terminal Largo de VIH , VIH-1 , ARN Viral , Juego de Reactivos para Diagnóstico , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Productos del Gen gag del Virus de la Inmunodeficiencia Humana , Seguridad de la Sangre , Selección de Donante , Femenino , Alemania , VIH-1/genética , VIH-1/metabolismo , Humanos , Masculino , ARN Viral/sangre , ARN Viral/genética , Cruz Roja , Estudios Retrospectivos , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/sangre , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/genética
4.
Br J Haematol ; 177(4): 612-619, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28378905

RESUMEN

Detection of immature platelets in the circulation may help to dissect thrombocytopenia due to platelet destruction from bone marrow failure (BMF). We prospectively tested the predictive value of immature platelets, measured as immature platelet fraction (IPF) on the XE-5000 (Sysmex, Kobe, Japan) or percentage of reticulated platelets (rPT) on the CD Sapphire (Abbott Diagnostics, Santa Clara, CA, USA) to separate immune thrombocytopenia (ITP) from BMF (leukaemia, myelodysplastic syndrome, aplastic anaemia). We analysed 58 samples of patients with BMF, 47 samples of patients with ITP and 97 controls. Median rPT (CD Sapphire) was increased to 9·0% in ITP and to 10·9% in BMF, compared to 1·9% in controls. Median IPF (XE-5000) was 16·2% in ITP, 10·2% in BMF and 2·5% in controls. We found an inverse correlation between high fractions of immature platelets and low platelet counts in thrombocytopenic samples regardless of the diagnosis. In conclusion, we observed a broad overlap of immature platelets between ITP and BMF, which may be caused by an accelerated release of immature platelets in any thrombocytopenic state and decreased production in many patients with ITP. Despite this, IPF (XE-5000) had some power to discriminate ITP from BMF, whereas rPT (CD Sapphire) was of no predictive value.


Asunto(s)
Anemia Aplásica/diagnóstico , Plaquetas/química , Enfermedades de la Médula Ósea/diagnóstico , Hemoglobinuria Paroxística/diagnóstico , Púrpura Trombocitopénica Idiopática/diagnóstico , Trastornos de Fallo de la Médula Ósea , Estudios de Casos y Controles , Diagnóstico Diferencial , Hematología/instrumentación , Humanos , Estudios Prospectivos , Curva ROC , Trombocitopenia/diagnóstico
5.
J Stroke Cerebrovasc Dis ; 25(4): 877-82, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26809705

RESUMEN

BACKGROUND: Oral anticoagulation with dabigatran was shown to be effective for stroke prevention in patients with nonvalvular atrial fibrillation without the need for laboratory monitoring. However, a recent publication based on data of the Randomized Evaluation of Long-Term Anticoagulation Therapy study reported that ischemic stroke and bleeding outcomes are correlated with dabigatran plasma concentration (DPC). DPC was determined at a prespecified time point and correlated with cardiovascular events at any time during follow-up. Because of the known variability of DPC, among others depending on renal function, this approach might compromise data evaluation. We report on dabigatran plasma levels in acute cerebrovascular events. METHODS: Consecutive patients with acute ischemic stroke (AIS) or intracerebral hemorrhage (ICH) while taking dabigatran were retrospectively identified if admission DPC was available. DPC was determined using the diluted thrombin time (Hemoclot (HYPHEN BioMed, Neuville sur Oise, France)). Creatinine clearance (CrCl) was determined by measuring creatinine in plasma and 24-hour urine. RESULTS: Fifteen AIS and 4 ICH patients were included. Median DPC on admission was significantly higher in ICH patients than in AIS patients (135 ng/mL [interquartile range {IQR} 79-218] and 69.1 ng/mL [IQR 20.6-85.0], respectively; P = .035). Increased CrCl (values above published normal range) was correlated with lower median DPC (60 ng/mL [IQR 10-69] versus 100 ng/mL [IQR 79-157] in patients with normal CrCl, P = .01). CONCLUSIONS: Higher DPC was found in ICH patients than in AIS patients in temporal proximity to the event. Both decreased and increased renal functions seem to have an important influence on DPC.


Asunto(s)
Dabigatrán/sangre , Hemorragias Intracraneales/sangre , Accidente Cerebrovascular/sangre , Anciano , Anciano de 80 o más Años , Creatinina/sangre , Femenino , Humanos , Masculino , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas
6.
Clin Chem Lab Med ; 51(11): 2125-31, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23800658

RESUMEN

BACKGROUND: Measurement of immature platelets was introduced into routine diagnostics by Sysmex as immature platelet fraction (IPF) some years ago and recently by Abbott as reticulated platelet fraction (rPT). Here, we compare both methods. METHODS: We evaluated the precision and agreement of these parameters between Sysmex XE-5000 and Abbott CD-Sapphire in three distinct thrombocytopaenic cohorts: 30 patients with beginning thrombocytopaenia and 64 patients with recovering platelets (PLT) after chemotherapy, 16 patients with immune thrombocytopaenia (ITP) or heparin-induced thrombocytopaenia type 2 (HIT) and 110 additional normal controls. Furthermore, we analysed, how IPF/rPT differed between these thrombocytopaenic cohorts and controls. RESULTS: Both analysers demonstrated acceptable overall precision (repeatability) of IPF/rPT with lower precision at low PLT counts. IPF/rPT artificially increased during storage of blood samples overnight. Inter-instrument comparison showed a moderate correlation (Pearson r²=0.38) and a systematic bias of 1.04 towards higher IPF-values with the XE-5000. IPF/rPT was highest in recovering thrombopoesis after chemotherapy and moderately increased in ITP/HIT. The normal range deduced from control samples was much narrower with CD-Sapphire (1.0%-3.8%, established here for the first time) in comparison to XE-5000 (0.8%-7.9%) leading to a smaller overlap of samples with increased PLT turnover and normal controls. CONCLUSIONS: IPF and rPT both give useful information on PLT turnover, although the two analysers only show a moderate inter-instrument correlation and have different reference ranges. A better separation of patient groups with high PLT turnover like ITP/HIT from normal controls is obtained by CD-Sapphire.


Asunto(s)
Plaquetas/patología , Neoplasias/sangre , Neoplasias/complicaciones , Recuento de Plaquetas/métodos , Estudios de Cohortes , Humanos , Trombocitopenia/sangre , Trombocitopenia/complicaciones
7.
BMC Vet Res ; 9: 192, 2013 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-24088206

RESUMEN

BACKGROUND: After addressing fundamental questions in preclinical models in vitro or in small animals in vivo, the translation into large animal models has become a prerequisite before transferring new findings to human medicine. Especially in cardiovascular, orthopaedic and reconstructive surgery, the sheep is an important in vivo model for testing innovative therapies or medical devices prior to clinical application. For a wide variety of sheep model based research projects, an optimal anticoagulation and antiplatelet therapy is mandatory. However, no standardised scheme for this model has been developed so far. Thus the efficacy of antiplatelet (acetylsalicylic acid, clopidogrel, ticagrelor) and anticoagulant (sodium enoxaparin, dabigatran etexilate) strategies was evaluated through aggregometry, anti-factor Xa activity and plasma thrombin inhibitor levels in sheep of different ages. RESULTS: Responses to antiplatelet and anticoagulant drugs in different concentrations were studied in the sheep. First, a baseline for the measurement of platelet aggregation was assessed in 20 sheep. The effectiveness of 225 mg clopidogrel twice daily (bid) in 2/5 sheep and 150 mg bid in 3/5 lambs could be demonstrated, while clopidogrel and its metabolite carboxylic acid were detected in every plasma sample. High dose ticagrelor (375 mg bid) resulted in sufficient inhibition of platelet aggregation in 1/5 sheep, while acetylsalicylic acid did not show any antiplatelet effect. Therapeutic anti-factor Xa levels were achieved with age-dependent dosages of sodium enoxaparin (sheep 3 mg/kg bid, lambs 5 mg/kg bid). Administration of dabigatran etexilate resulted in plasma concentrations similar to human ranges in 2/5 sheep, despite receiving quadruple dosages (600 mg bid). CONCLUSION: High dosages of clopidogrel inhibited platelet aggregation merely in a low number of sheep despite sufficient absorption. Ticagrelor and acetylsalicylic acid cannot be recommended for platelet inhibition in sheep. Efficient anticoagulation can be ensured using sodium enoxaparin rather than dabigatran etexilate in age-dependent dosages. The findings of this study significantly contribute to the improvement of a safe and reliable prophylaxis for thromboembolic events in sheep. Applying these results in future translational experimental studies may help to avoid early dropouts due to thromboembolic events and associated unnecessary high animal numbers.


Asunto(s)
Anticoagulantes/farmacología , Inhibidores de Agregación Plaquetaria/farmacología , Agregación Plaquetaria/efectos de los fármacos , Enfermedades de las Ovejas/prevención & control , Trombosis/veterinaria , Animales , Anticoagulantes/administración & dosificación , Anticoagulantes/farmacocinética , Relación Dosis-Respuesta a Droga , Humanos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/farmacocinética , Ovinos , Trombosis/prevención & control
9.
Health Policy ; 79(2-3): 306-12, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16516334

RESUMEN

OBJECTIVES: The hepatitis B vaccination policy in Germany was intensified by the implementation of hepatitis B vaccination for adolescents in the vaccination calendar in 1995. To investigate the effect of this measure on the hepatitis B vaccination coverage of healthy adults, we analysed the hepatitis B vaccination status of blood donors. Furthermore, the reasons for vaccination and the relationship between vaccination status and age, sex, and current profession were studied. METHOD: Using a standardised questionnaire, randomly incoming whole blood donors were asked for hepatitis B vaccination status, the reason for vaccination, gender, age and current profession. Multiple logistic regression analysis with vaccination status as dependent variable and age, gender and current profession as explanatory variables was performed. RESULTS: Overall, 1519 (22.3%) of the 6812 interviewed whole blood donors were vaccinated against hepatitis B. Younger age was significantly associated with higher acceptance of hepatitis B vaccination with already 44.1% of whole blood donors aged 18-29 years being hepatitis B immunised. Beside health care workers, teaching professions and students showed the highest hepatitis B vaccination rate. Foreign travel was nearly an equivalently important reason for hepatitis B vaccination as occupational risks. CONCLUSION: The high hepatitis B vaccination coverage among young and healthy adults indicates the success of the intensified hepatitis B vaccination policy since 1995. However, concentrating education measures on individuals with lower educational level and intensifying hepatitis B vaccination in the context of foreign travel could further increase the acceptance of hepatitis B vaccination.


Asunto(s)
Virus de la Hepatitis B/inmunología , Hepatitis B/prevención & control , Inmunización/estadística & datos numéricos , Adolescente , Adulto , Anciano , Donantes de Sangre , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
10.
Am J Clin Pathol ; 139(5): 641-50, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23596116

RESUMEN

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in a total of 202 samples from hematology patients and normal controls. Manual differential count was used as reference. The analyzers exhibited very good correlation for CBC parameters. Neutrophils and eosinophils also showed very good correlations, whereas lymphocytes and monocytes correlated fairly. The Advia 120 displayed notably lower measurements for both parameters, which is attributable to classification of some events as large unstained cells. Basophil counts were unreliable with all analyzers. Flagging for blasts and immature granulocytes showed moderate sensitivity and specificity. Operators must not rely on blast flagging alone to detect leukemic samples with any analyzer.


Asunto(s)
Recuento de Eritrocitos/instrumentación , Enfermedades Hematológicas/diagnóstico , Recuento de Leucocitos/instrumentación , Recuento de Plaquetas/instrumentación , Autoanálisis , Crisis Blástica/diagnóstico , Crisis Blástica/patología , Eosinófilos/citología , Granulocitos/citología , Enfermedades Hematológicas/inmunología , Humanos , Linfocitos/citología , Monocitos/citología , Neutrófilos/citología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Transfusion ; 47(7): 1241-9, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17581159

RESUMEN

BACKGROUND: This prospective study compared white blood cell (WBC) storage in polyvinylchloride (PVC) bags and in polyolefin (POF) bags. After leukapheresis, CD14+ monocytes, CD11c+, and CD123+ precusor dendritic cells (DCs) were analyzed under platelet (PLT) storage conditions. STUDY DESIGN AND METHODS: Twenty-five leukapheresis procedures were performed on blood cell separators (AS.TEC204 [PVC; Fresenius HemoCare GmbH] and the COBE Spectra [POF, Gambro BCT]). Blood cell counts, glucose, lactic acid, pO(2), pCO(2), and pH were measured in mononuclear cell (MNC) harvests on Days 0, 1, 3, and 5. WBCs were analyzed by flow cytometry. RESULTS: The WBC yields of the AS.TEC204 harvests were 25 percent higher (13.4 x 10(9) +/- 2.7 x 10(9) WBCs) compared to the COBE Spectra (9.9 x 10(9) +/- 2.5 x 10(9) WBCs). During 5-day storage, WBC counts (PVC bags) decreased significantly (24%). Storage in POF bags showed more consistent results (WBC loss, 6%). Loss of CD14+ monocytes and CD11c+ precursor DCs did not differ significantly in leukapheresis products. CD123+ precursor DCs stored in PVC bags dropped by more than 90 percent (POF bags, 24%). Lactic acid concentrations exceeded 20 mmol per L after 24 hours in PVC bags and after 72 hours in POF bags. The mean pH value on Day 5 was 6.2 (PVC) and 6.3 (POF). On Day 1, the product glucose concentration decreased by 76 percent after storage in PVC bags and by 16 percent in POF bags. CONCLUSIONS: Storage of MNCs within 72 hours in the original harvest container assures stable WBC content and is easy to perform. POF bags should be preferred in the case of extended WBC storage. Patient studies should clarify changes in efficiency of hematopoietic reconstitution that might occur over time during MNC storage.


Asunto(s)
Antígenos CD/análisis , Conservación de la Sangre , Células Dendríticas , Leucaféresis , Monocitos , Antígeno CD11c , Glucosa/análisis , Humanos , Concentración de Iones de Hidrógeno , Subunidad alfa del Receptor de Interleucina-3 , Recuento de Leucocitos , Receptores de Lipopolisacáridos , Polienos , Cloruro de Polivinilo , Estudios Prospectivos
12.
Transfusion ; 47(9): 1658-65, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17725731

RESUMEN

BACKGROUND: The aim of this study was to investigate the effect of gamma irradiation with 30 Gy on the coagulation system in leukoreduced fresh-frozen plasma (FFP). STUDY DESIGN AND METHODS: In 74 FFP units that had been stored for 352 +/- 103 days below -30 degrees C, the following variables were determined in parallel in an irradiated and not irradiated half: prothrombin time (PT); activated partial thromboplastin time (APTT); thrombin time; antithrombin III; protein C; protein S; von Willebrand factor antigen; ristocetin cofactor; plasminogen-alpha(2)-antiplasmin; the coagulation factors fibrinogen, factor (F)II, FV, FVII, VIII, F IX, FX, FXI, FXII, FXIII, and activated factor XII (FXIIa); D-dimer; fibrin monomer; thrombin-antithrombin complex; prothrombin fragment 1 + 2 (F1+2); plasmin-alpha(2)-antiplasmin complexes (PAPs); and platelet factor 4. The FVII activity ratio was assayed to quantify activation of FVII. RESULTS: Irradiation with 30 Gy resulted in a reduction of APTT (35.0 +/- 4.1 sec vs. 34.4 +/- 4.1 sec; p = 0.00000006) and PT (89.8 +/- 8.2% vs. 90.7 +/- 8.0%; p = 0.002) and a significant increase of the activities of the coagulation factors FII, FV, FVII, F IX, FX, and FXII. FVIII activity decreased from 118 +/- 31 to 116 +/- 32 percent (p = 0.02). Activation of the coagulation system was shown by an increase in the FVII activity ratio (1.19 +/- 0.29 vs. 1.31 +/- 0.34; p = 0.0000001), FXIIa (0.81 +/- 0.50 ng/mL vs. 0.90 +/- 0.51 ng/mL; p = 0.006), and F1+2 (1.19 +/- 0.20 nmol/L vs. 1.24 +/- 0.20 nmol/L; p = 0.000005) after irradiation with 30 Gy, whereas an increase of PAP (16.2 +/- 11.5 ng/mL vs. 20.2 +/- 12.0 ng/mL; p = 0.0004) demonstrated activation of the fibrinolytic system. No negative influence of irradiation with 30 Gy on inhibitors of coagulation was observed. CONCLUSION: Gamma irradiation of leukoreduced FFPs with 30 Gy results in a significant but very weak activation of the coagulation and fibrinolytic system in FFPs.


Asunto(s)
Coagulación Sanguínea/efectos de la radiación , Leucocitos , Plasma/efectos de la radiación , Rayos Ultravioleta , Sistema del Grupo Sanguíneo ABO , Biomarcadores , Separación Celular , Relación Dosis-Respuesta en la Radiación , Hemostasis/efectos de la radiación , Humanos
13.
Transfusion ; 47(6): 987-94, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17524087

RESUMEN

BACKGROUND: The Fresenius COM.TEC cell separator is a new device for producing white cell concentrates (WBCs) and leukoreduced single-donor platelet concentrates (SDPs) and performing therapeutic cytapheresis and plasmapheresis that might replace the Fresenius systems AS104 and AS.TEC 204. This novel system's performance was evaluated for producing leukoreduced SDPs. STUDY DESIGN AND METHODS: In an investigational phase, each of 200 donors underwent plateletpheresis with the AS.TEC 204 and the COM.TEC systems. The collection efficiency (CE) and WBC contamination of the different techniques were compared. After some hard- and software modifications, the system was evaluated in an additional 800 procedures in the confirmatory phase. RESULTS: In the investigational phase, the CE of the COM.TEC device was increased significantly in comparison to the AS.TEC 204 device's CE (by 45 +/- 32% when collecting 1 unit of platelets [PLTs] and 1 unit of fresh-frozen plasma and by 43 +/- 42% when collecting only 1 unit of PLTs). Although all AS.TEC products proved to be leukoreduced, 2 percent of the COM.TEC procedures led to PLT concentrates containing more than 1 x 10(6) WBCs. In the confirmatory phase, all 1300 products from 800 COM.TEC procedures proved to be leukoreduced. Furthermore, the CE increased significantly from 53.5 +/- 4.6 percent in the investigational phase to 55.5 +/- 4.9 percent (p < 0.001) in the confirmatory phase. CONCLUSIONS: These data suggest that the new COM.TEC system offers a significantly and importantly improved CE in plateletpheresis procedures in comparison to the AS.TEC system. In the final version, the PLT products collected with this system fulfill the most stringent criteria for leukoreduced PLTs. This aim was achieved without additional filtration steps and thus without filtration-related PLT loss.


Asunto(s)
Donantes de Sangre , Plaquetas/citología , Procedimientos de Reducción del Leucocitos/instrumentación , Plaquetoferesis/instrumentación , Humanos , Procedimientos de Reducción del Leucocitos/normas , Plaquetoferesis/normas
14.
Transfusion ; 47(12): 2297-304, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17764511

RESUMEN

BACKGROUND: The standard mononuclear cell (MNC) program of the COM.TEC device (Fresenius HemoCare GmbH) showed excellent collection efficiency of CD14+ monocytes. A major disadvantage was high content of residual cells in MNC harvests, which could influence dendritic cell (DC) culture. STUDY DESIGN AND METHODS: The autoMNC program (COM.TEC) was compared with the standard MNC program (n = 12). Additionally, two cycle volumes (300 mL vs. 450 mL, n = 19) were compared (standard MNC program). Samples were assayed for white blood cells (WBCs), red blood cells (RBCs), granulocytes (PMNs), hematocrit, and platelets (PLTs) on an automated blood cell counter (Sysmex K 4500, TAO Medical). CD14+ cells were analyzed by flow cytometry (FACSCalibur, BD). RESULTS: The autoMNC program produced 1.33 x 10(9) +/- 0.36 x 10(9) CD14+ cells, 5.60 x 10(11) +/- 0.97 x 10(11) PLTs, and 1.43 x 10(11) +/- 0.37 x 10(11) RBCs. Compared to the standard MNC program, significantly higher PLT yields but lower RBC yields and product volume were harvested. Increasing the CV from 300 to 450 mL dropped the product volume, residual PLTs, and RBCs significantly, whereas WBC and monocyte yields did not change. The WBC predonation counts of donors correlated significantly with monocyte yields. CONCLUSIONS: The autoMNC program reduced the buffy coat (BC) volume and RBC yields in products compared to the standard MNC program. Increasing the CV (standard MNC program) reduced residual PLTs, RBCs, and the BC volume of MNC harvests. The donor WBC predonation count was a good predictor for the monocyte yield of products.


Asunto(s)
Separación Celular/métodos , Células Dendríticas/citología , Leucaféresis/métodos , Leucocitos Mononucleares/citología , Receptores de Lipopolisacáridos/análisis , Separación Celular/instrumentación , Células Dendríticas/inmunología , Humanos , Leucaféresis/instrumentación , Recuento de Leucocitos , Leucocitos Mononucleares/inmunología , Reproducibilidad de los Resultados , Programas Informáticos
15.
Transfusion ; 46(2): 236-43, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16441601

RESUMEN

BACKGROUND: Rare clinical conditions cause the need for washed platelet (PLT) concentrates (PCs). Saline-washed PCs can only be stored shortly, however, owing to lack of substrates for PLT metabolism. New PLT additive solutions (PASs) contain such substrates and might be used alternatively. The in vitro quality of apheresis PCs washed with Composol-PS or modified PAS-III (PAS-IIIM) stored up to 48 hours after wash was compared. STUDY DESIGN AND METHODS: Twelve blood donors underwent two apheresis procedures (A and B) collecting 6.0 x 10(11) PLTs in 500 mL of plasma with a least 2 weeks in between. The PCs collected by Apheresis A were stored for 3 days and then split in two equal units before washing with Composol-PS or PAS-IIIM. The PCs collected by Apheresis B were split after collection. One unit was released for transfusion and 1 unit was stored unwashed up to Day 6 and used as reference unit. In vitro testing was performed before and after washing as well as 24 and 48 hours after wash. RESULTS: After 48 hours of postwash storage, the units washed with either PAS showed acceptable results for hypotonic shock response (HSR), P-selectin expression, and pH, whereas PLT aggregability was significantly impaired. Throughout the storage, unwashed units showed better in vitro quality. HSR and P-selectin expression were similar before and immediately after the washing procedure. CONCLUSION: Based on these in vitro results, 48-hour postwash storage of washed PCs with the two PASs seems to be feasible. In vivo recovery studies, however, must confirm this finding in the future.


Asunto(s)
Plaquetas/citología , Conservación de la Sangre/métodos , Criopreservación/métodos , Soluciones Preservantes de Órganos , Plaquetas/metabolismo , Humanos , Concentración de Iones de Hidrógeno , Técnicas In Vitro , Presión Osmótica , Selectina-P/metabolismo , Activación Plaquetaria , Plaquetoferesis
16.
Transfusion ; 46(1): 66-73, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16398732

RESUMEN

BACKGROUND: The COM.TEC cell separator (Fresenius Hemocare), equipped with the MNC program (single-stage chamber) and the PBSC-LYM program (dual-stage chamber), was evaluated for CD 14+ cell collection regarding cell yields, collection efficiencies (CEs), and the content of residual cells in harvests. STUDY DESIGN AND METHODS: Twenty-four non-cytokine-stimulated donors underwent 5-L mononuclear cell (MNC) collections on the COM.TEC device to compare both programs. Two software versions (v02.03.05 vs. v 03.00.04) were investigated for optimization of the CD 14+ cell collection process. Blood counts of donors and products were analyzed for CD 14+ cells by flow cytometry and for platelets (PLTs), white blood cells, and red blood cells (RBCs) by a blood cell counter. RESULTS: In 5-L collections, the MNC program resulted in high CEs (83+/- 23%) and yields (1.2 x 10(9)+/- 0.6 x 10(9) per unit) of CD 14+ cells, but the products showed high residual PLTs. The use of a dual-stage chamber in the PBSC-LYM program produced a low content of residual PLTs (0.7 x 10(11) +/- 0.3 x 10(11) per unit) and RBCs but failed to reach a target of 1 x 10(9) CD 14+ cells. Modulated light to stabilize the buffy-coat detection by the interface monitor significantly improved CD 14+ cell enrichment. By use of the PBSC-LYM program, higher centrifuge velocity (1700 rpm [382 x g] vs. 1500 rpm [297 x g]) improved significantly CD 14+ cell yields (0.7 x 10(9) vs. 0.5 x 10(9) cells). CONCLUSION: A pure CD 14+ cell product with low numbers of residual cells was obtained by the PBSC-LYM program, which could be useful for good manufacturing practice-conformed production within closed systems. The MNC program offers the collection of high CD 14+ cell yields with excellent CEs but also high residual PLT counts.


Asunto(s)
Donantes de Sangre , Leucaféresis , Leucocitos Mononucleares , Receptores de Lipopolisacáridos , Programas Informáticos , Femenino , Humanos , Leucaféresis/instrumentación , Leucaféresis/métodos , Masculino
17.
Transfusion ; 46(5): 757-65, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16686843

RESUMEN

BACKGROUND: Only a few systematic studies have examined the effect of variable produced small platelet (PLT) aliquots on PLT function before transfusion to neonates. Although neonatal transfusion could be critical, no standardization of production or systematic quality controls have been introduced so far. STUDY DESIGN AND METHODS: PLT split products were prepared in three different ways (30- or 60-mL bag, syringe aliquot) at different times from the parent unit (Days 1-4) and stored for 2 or 4 hours. The measures of PLT function include pH, lactate, P-selectin expression, and cytokines (beta-thromboglobulin [beta-TG], PLT-derived growth factor AB [PDGF-AB]). Additionally, syringe passage (0.5 mL/min) was assessed. RESULTS: High product variability of PLT content was found (40% deviation of PLT content from programmed target, 13%-19% PLT loss by product distribution), which resulted in PLT concentrations of split units between 0.94 x 10(9) and 1.66 x 10(9) PLTs per mL. Different gas transfer rates (pCO2) of PLT containers caused different pH values of the product (Trima 7.47 +/- 0.09 vs. COM.TEC 7.33 +/- 0.08; p < 0.0001), but acceptable results of PLT metabolism were found in all split units (minimum pH, 7.09; maximum lactate content, 13.1 mmol/L). P-selectin expression on PLTs increased by factor of 2 in the parent units stored for 4 days (16.9 +/- 8.6% 32.2 +/- 13.4%; p = 0.02). After Day 3, beta-TG and PDGF-AB increased by twofold. PLTs stored during passage for 100 minutes in syringes dropped pO(2) by 50 percent and caused 15 percent higher lactate levels. CONCLUSION: High variability of PLT content in split units requires at least additional PLT counts before transfusion in critical preterm or neonatal infants.


Asunto(s)
Plaquetas/química , Ácido Láctico/análisis , Selectina-P/análisis , Factor de Crecimiento Derivado de Plaquetas/análisis , beta-Tromboglobulina/análisis , Adulto , Conservación de la Sangre , Femenino , Humanos , Concentración de Iones de Hidrógeno , Recién Nacido , Masculino , Recuento de Plaquetas , Transfusión de Plaquetas , Plaquetoferesis , Reproducibilidad de los Resultados , Factores de Tiempo
18.
Transfusion ; 46(6): 942-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16734810

RESUMEN

BACKGROUND: The quality of platelets (PLTs) stored in PLT additive solution (PAS) is dependent on the type and proportion of the used PAS. No data are available as to whether a different hold time before the addition of PAS to hyperconcentrated PLT suspensions has an impact on PLT quality. The in vitro quality between single-donor PLT concentrates was compared with two different hold times with two PASs. STUDY DESIGN AND METHODS: On two occasions, 6x10(11) PLTs in 150 mL of plasma were collected from 20 blood donors. The units were split into two equal parts, and 140 mL of PAS-II or PAS-IIIM (randomized sequence) was added after 2 or 8 hours resulting in a PAS proportion of 65 percent. On Days 1, 5, and 7, glucose and lactate concentration, pH value, PLTs' P-selectin expression, response to hypotonic shock, and release of transforming growth factor-beta1 were determined. RESULTS: On all days, the lactate concentrations were higher and pH values were lower in units with an 8-hour hold time, whereas the results of in vitro tests relating to the in vivo viability and activation of PLTs were similar for both groups. PAS-IIIM-stored PLTs showed a lower glycolytic activity and better results in all performed in vitro tests than PAS-II-stored PLTs. CONCLUSIONS: Although the metabolism of glucose was enhanced during hold time, the differences between both hold time groups are not meaningful from a biological viewpoint. Therefore, an 8-hour hold time is feasible. PLT storage in PAS-IIIM results in a PLT in vitro quality superior to that of PLTs stored in PAS-II.


Asunto(s)
Plaquetas/efectos de los fármacos , Conservación de la Sangre/métodos , Plaquetoferesis/normas , Soluciones/farmacología , Glucosa/metabolismo , Humanos , Concentración de Iones de Hidrógeno , Ácido Láctico/análisis , Presión Osmótica , Selectina-P/análisis , Factores de Tiempo , Factor de Crecimiento Transformador beta/análisis , Factor de Crecimiento Transformador beta1
19.
Transfusion ; 45(3): 445-52, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15752165

RESUMEN

BACKGROUND: We introduced monitoring of mononuclear cell (MNC) counts to obtain enhanced donor control and a stable quality of MNC products, because there are limited data available about blood donors after serial leukapheresis (LP) procedures. STUDY DESIGN AND METHODS: In a prospective paired study, 13 male healthy blood donors underwent 10-L LP procedures performed on two apheresis devices by use of two MNC program settings (COBE Spectra, Gambro BCT, SF 250 vs. SF 500; and AS.TEC 204, Fresenius Hemocare, CP 129 vs. CP 194). Donors' pre- and postdonation MNC counts were analyzed by fluorescence-activated cell sorting. RESULTS: After each 10-L LP procedure, a transient decline (p < 0.05) of CD14+ monocyte and platelet counts appeared in donors. Loss of donors' CD3+ T cells, CD19+ B cells, and CD16+56+ natural killer (NK) cells during MNC collection was partly compensated by cell recruitment. The MNC recruitment factor (RF) seems to be higher with high-yield MNC program settings. Negative correlations (p < 0.01) were noticed between predonation counts and RFs of CD3+ T cells and CD16+56+ NK cells. Four serial 10-L LP procedures did not result in long lasting MNC depletion for donors. CONCLUSION: MNC recruitment seems to depend on MNC program settings and collected cell yields. Low MNC counts could result in high cell recruitment that may contribute to stable collection results to some degree. Nevertheless, there seems to be a considerable individual variation of MNC recruitment in donors that should be investigated in more detail.


Asunto(s)
Leucaféresis/instrumentación , Leucaféresis/métodos , Leucocitos Mononucleares/citología , Adulto , Estudios de Seguimiento , Humanos , Recuento de Leucocitos , Subgrupos Linfocitarios/citología , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Estudios Prospectivos
20.
Transfusion ; 45(5): 788-97, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15847670

RESUMEN

BACKGROUND: Standard plateletpheresis techniques and effects on platelet (PLT) donors were investigated to provide an informative basis for advancement of apheresis software. STUDY DESIGN AND METHODS: Three paired groups with 33 male and 22 female blood donors were prospectively investigated by analyzing blood counts of donors and products. Four apheresis platforms, the COBE Spectra LRS and the Trima v4 (Gambro BCT) and the AS.TEC204 and the COM.TEC (Fresenius Hemocare), were compared. Deviations of the collected from programmed PLT targets and donor PLT recruitment were calculated for single-unit PLT concentrates (SU-PCs; 3 x 10(11) PLTs) and double-unit PLT concentrates (DU-PCs; 6 x 10(11) PLTs). RESULTS: Regarding SU-PCs, the productivity of the COM.TEC machine was superior to the AS.TEC204 machine, because of shorter processing time (54 min vs. 67 min) and higher yields (2.90 x 10(11) PLTs vs. 2.75 x 10(11) PLTs). Compared to the Spectra machine, the Trima v4 machine showed higher collection efficiencies (CEs) and shorter processing time and complied better with the programmed target (SU-PCs, 3.24 x 10(11) PLTs vs. 3.70 x 10(11) PLTs; DU-PCs, 6.87 x 10(11) PLTs vs. 7.56 x 10(11) PLTs). Harvests of the Spectra machine (DU-PCs) exceeded the target by 40 percent, which resulted in high PLT loss for donors. A longer processing time resulted in some higher CEs (SU-PCs, 53%; DU-PCs, 58%), which could contribute to this result. PLT recruitment compensated PLT loss to some extent. CONCLUSION: The major finding was that the newer devices (COM.TEC and Trima) gave more predictable yields than the older devices (AS.TEC204 and Spectra) and resulted in lower PLT deficit. PLT software should be improved to minimize relevant variations of collected yields regarding the programmed target.


Asunto(s)
Donantes de Sangre/psicología , Plaquetoferesis/instrumentación , Plaquetoferesis/métodos , Programas Informáticos , Adulto , Eliminación de Componentes Sanguíneos/instrumentación , Eliminación de Componentes Sanguíneos/métodos , Femenino , Humanos , Masculino , Agujas , Recuento de Plaquetas , Estudios Prospectivos , Factores Sexuales , Factores de Tiempo , Voluntarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA